Correspondence / 0,2 zo eet-LeA-r R(
GR OUP
# ACKENZIE
October 15, 2004
City of Tigard
Attention: Brian Blalock, Building Official
13125 SW Hall Blvd
Tigard, Oregon 97223
via fax: 503- 624 -3681
Re: Concero
Appeal of Exiting Separation
H1 03
O CV
Project Number 2020951.05
M
P O
Dear Brian:
o
• `" This letter is being written to request an appeal of Uniform Building Code (UBC) Section
- 3 1004.2.4, Separation of exits or exit - access, approved per section 104.2.8 of O.S.S.C., for the
above referenced tenant improvement.
—
M
We propose demolition of some existing walls on the fifth floor of the Two Lincoln Building.
The resulting area is approximately 3,786 SF, requiring two exits. The building is six stories,
o Type II -FR, fully sprinklered with an automatic smoke detection system in the corridors.
UBC Section 1004.2.4, Separation of exits or exit- access doorways
As you can see from Attachment A, the existing exit door is separated from the new exit door
3 M by approximately 41' -10 ", which is approximately 9' -8" less than the required separation
distance of approximately 51' -6" (one -half the diagonal distance of approximately 103' -0 ").
O
o
Evaluation of this condition under IBC, Section 1014.2.1, Exception 2, would allow for this
configuration of exits. The required separation would be approximately 34' -4" (one -third the
diagonal distance). The building is fully sprinklered and the exits will be greater than
Group one -third the diagonal distance apart.
Mackenzie,
Incorporated
Architecture Please feel free to call to review or I would be happy to meet at your office to discuss. Thank
Interiors you for taking the time to consider this appeal.
Land Use Planning
Sincerely,
Group
Mackenzie
Engineering,
Incorporated e hys Ii‘ cys
Civil /Structural Architect
Engineering
Transportation Enclosure: Attachment A
Planning
c: Brian Blalock — City of Tigard
Locations: Krista Bailey — Equity Office
Portland, Oregon
Tacoma, Washington