Loading...
Permit CITY TIGARD SITE WORK PERMIT DEVELOPMENT SERVICES PERMIT # : SIT2003 -00014 ., DATE ISSUED : 7/21/03 1 3125 S V T� all BIB., Tigard, OR 97223 (503) 639 -4171 SITE ADDRESS: �1�85 ' SW GRANT ST PARCEL : 2S102C6 00100 SUBDIVISION: NORTH TIGARDVILLE ADDITION ZONING : R -12 BLOCK: LOT: 041 JURISDICTION : TIG CLASS OF WORK: NEW PAVING ?: Y RESO. NO: TYPE OF USE: COM GRADING ?: Y VALUE: 200,000.00 EXCV VOLUME: 2,500 cy LANDSCAPING ?: FILL VOLUME: 4,000 cy SITE PREP ?: ENG FILL ?: STORM DRAINS ?: Y SOILS RPT REQD ?: N IMPERV SURFACE: 57,000 sf Remarks: Site work for new building. Owner: FEES TIGARD - TUALATIN SCHOOL DISTRICT 6960 SW SANDBURG RD Description Date Amount TIGARD, OR 97223 [BUPPLN] Pln Ck -Valu 5/15/03 $737.30 _ [FLS] FLS Pln Rv 5/15/03 $453.72 [ERPRMT] Erosion Cntl 7/21/03 $140.00 Phone: [ERPLN] Ersn Plck -USA 7/21/03 $45.50 Contractor: [EROSN] Ersn Plck -COT 7/21/03 $45.50 BAUGH-SKANSKA CONST [BUILD] Prmt Fee-Valu 7/21/03 $1,134.30 2555 SW 153RD [TAX] 8% St Tax -Valu• 7/21/03 $90.74 BEAVERTON, OR 97006 Total $2,647.06 Phone: 503 - 641 -2500 Reg #: LIC 153980 Required Inspections Erosion Control lnsp 846 -8444 Paving lnsp Sprinkler supply lines Final Inspection This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain copies of these rules or direct questions to OUNC by calling (503) 246 -6699. Issued By: Permittee Signature: ,�.11' /� W, __WMtraVi - Call (503) 63! -4175 by 7:00 P.M. for an inspection needed the next business day ' • LI 4 G� G F-- f ' ` .:,.,:,3A,:: : . >.- FOR` OFFIGE�USE ONLY��'�;s�`''..��.��,��,;c�?' Building Permit A�e Received Building Date /By /SO3 V Permit No S (T J3 2 O/ 1{ City f '�1 and � Planning Approval Other Y g ^ J Date /By. Permit No.: 13125 SW Hall Blvd. MAY 1 [ Plan Review Other Tigard, Oregon 97223 A RD _ Date /By. a7_ / g . 0 113 Permit No . Phone: 503- 639 -4171 Fax: ��E5 1 ; ;. . Post- Review Land Use Y � G 1 S F �h . �1� , Date /By. _ Case No. Internet: www.ci.tigard.or.u %L N .*�- -- ' ? Co ntact Juns.. ® See Page 2 for 24 -hour Inspection Request: 503 -639 -4175 , Name /Method fi 10 Supplemental Information ' a -'r.' :'�s•�a�g - --° - ,7.e} „ -v, .i"'._� M w^.,..: . f 3k':: .�.�: �,�'- °eN;i -`; �.e: "�».: ;.7'�. a;�,:�,'s� `i.�;:' - `.kk�%' x ° ,:.:; �� ' .,.�. °x'°` ^',r , - S „� i 6;,r,. 7 "r; '�'i:,t - x as wr a _ , y s ., , :c, "_�” �.,a��, - �:T�YPE' ='OFWORK.� - �.:�;,,, .;�"����t��'� � �.. +.,� }; _ �.;;��,t �;" � ��,.. �w •.,. "xs= . °s`'s' ,,. ' ;k &EQ IR D AFT ,,; , :,,. _ ,_ - , _ 4r.: �, , cs, �., „_. . a _ � ';..r "a €.::� >r't����-,�, �;•`'e," f.�e _�'':�- 4 ;. £ �3;L ":.; Demolition New construction �) �.c � "� : �' ;, `l� & �,2; =PANE Y =DWELL3IN.G ° ` :� =� ; � ,`r',,,..�`',ke aa n�s�>: .<,._ �'y�, a�.�.:F�.',:.€a=u .s . ,�,,: .,� �_`fi -'�� ;���.. .,.� .�SC. S''= "�ca�: ° - ` ~ �. to ❑ Addition/alteration/replacement ❑ O ther: �� �; ei Ri'•'' =i ISr.fi TEG®RY ®F`CONS)•A-Rtlaf 03?i a g Note: Permit fees* are based on the total value of the work performed Indicate Q, the value (rounded to the nearest dollar) of all equipment, matenals, labor, r `q `r6 ❑ 1 & 2- Family dwelling 2 COmmercial/1ndustrlal overhead and profit for the work indicated on this application v U `) ❑ Accessory Building ❑ Multi - Family ❑ Master Builder ❑,Other: Valuation $ -; ': JOB SITE'�INFORl!%IATION and LO;CATtI(JN ` w_-"' 1 No. of bedrooms. No. of baths: Job site address: f — Stv C7 / ;Py f ,4 y e, Total number of floors -New dwelling.area (sq. ft.).... Suite #: /? g j .," Bldg. / Apt. #: Garage carport=area (sq. ft.) Project Name: GFf Elem e l ILiod ,d Covered porch area (sq. ft.) Cross street/Directions to job site: f Deck area (sq. ft.) Other structure area (sq. ft.) ...... .. ct �t PA) Scttov/ J/. reroS$ S r t 7 . , �+ j�� �a.,, %� " ^a�;»v. - 'g - ; pie - ' ..'"�.:- ?�`»��':�;. , ;.yg�:� erz�, -K, � � ^ "� % = -, Y ; ;4 £ .vi a =R E ,UIRED: DAT , �„ }3 - ,. i' ,1 ,- id „. - - T = ;COMINIE "CHECK - L IST - F° ,; t - ' = . 4 Lot #: , .a - <iAgi E l• '. , "zx3 1 `k`:* ` '.A ¢ .4' :,. ,3, .3-- toi:,, - a.., - =;�r. =h V, .. m. + _:. : , Subdivision: `D Tax map /parcel #: Note Permit fees* are based on the total value of the work performed Indicate ,- ,1 :1°fit =` w ' °° k,.,F 4h DESCR:1'PTIoN`�OF„ WORK :, ". E' -=" t` - ' '` �� ''�� the value (rounded tof ) of all eq, " "� °' '° " ” overhead and profit for the the nearest work m on this uipment application matenals, labor, S/fe 1 ✓Ad /'A f eivsio c „h froS 4.1 b. 4 hi Ge o?' .0 ,„, n`t , Valuation $ 2a 000 Existing building area (sq. ft ) New building area (sq. ft.).... .. ......... .... 6 7 Sap Number of stories 2- P°EPROP :ERTY OWNER] .2>, 3 ®- TENANT " ?-r 'a . '' Type of construction Name: 5'4-t � /i e , h P o a / L Occupancy group(s) Existing: Address: 6 y 6 o St,/ fit n1 6N I St City /State /Zip: 7 et e d f o/2 f 7 22-3 NOTICE: All contractors and subcontractors are required to be Phone: �n3 a 3/d -- 9 Fax Sb�� 4 /N 40Y licensed with`the Oregon Construction Contractors Board unde ” ' ` is 'F. r, CONTACTRERSON ,l I F, ��'.'� �" : a ` .f. =� " provisions of ORS 70 ] and may be required to be licensed in the t Business Name: Cor*erf /z e_ (OH sfri4Chd i'l MI f. jurisdiction where work is being performed. If the applicant is exempt Contact Name: :540 Abe I from licensing, the following reason applies: Address: S o SW aca - , al h . .fig Z2 City /State /Zip: P f' p 1, 0 9 7 43 9 Phone: Sa3 Jos- b o ' Fax: Sv3 - 29r-f196 ;. & : __ ' ..: . , i::n i °_ , - r Aag;::- #: 53r;" ..,,,.r :a � ,, ,," ,i ..;; , `- °v g qi DING PERITITYF=FrE : "` ' x � xvs�,r ,:�_.p E -mail: o�wr,, CorNe ✓cti�a.A.t , . coo �`A. s,,•4 , r t;, ,n . .., `t' »,''..`�' -• .� � „��, ;.' t �� ',�Pleas``refer: =f °';'' §:;:�vy to., ee= sc h eduled , . , k; :,,�;;' ' ";`*°.' 'ri °9i;a "3= ,"a,z..r ... - .'x '';: is �:; _ , ..;� -.,, °:. ai :.- .._ -_.' N�J,>;" ,: > w.�..,,. _ .. :;:,.:.' ; m;:_'.. " u'3 � r,r:�x... ,.-:". _ _ ., y .. : . 1LL. " .' CbN <` .,,. t.t° : °s.'; Business Name: Rap I4 — 5krta-A trims /. _ Fees due upon application.. $ Address: ZS r3 , - SW f$3'" ' A. City /State /Zip: Re / dr.. q 700 ( Amount received....... $ Phone: s-o; - 614/ - Zs Fax: 9 3-6 y3 - 0 6 y 6 Date received: - CCB Lic. #: /s 3 Authorized Notice: This permit application expires if a permit is not obtained within Signature. � � Date 180 days after it has been accepted as complete. / h t_ *Fee methodology set by Tri- County Building Industry Service Board. (Please print name) 7,) 3O i. \Dsts\Permit Forms \BldgPermitApp doc 01/03 pi_s LI 6 3 s 1 , e ` vs • SITE WORK PERMIT CHECK LIST Commercial, Multi - Family (R -1 occupancy) and Residential: Please complete all items below, unless otherwise noted. Excavation Volume: Z So o cu. yds. Grading Volume: (Soils report required for >5,000 cu. yds.) 99 oo o cu. yds. Fill Volume: (Fill exceeding 12" in depth shall be compacted to 90% of • maximum density) o o v cu. yds. Retaining structure? (Check one) ❑ Rock ❑ CMU ❑ Concrete ❑ Other *Total new impervious area including all buildings, sidewalks, and paving: sq. ft. Site Utilities Plumbing Work: Complete the Plumbing Permit Application for site utilities plumbing work. aired: See.�.�Site >.;Wock:� :Permif - A�' ` licatlon��-': I'Ian�xS�ubrittal�Req�uirements Ym :;,��i� ; �, , attached.'','Tho' :;followm rr"i_u °st accori ari. `tf isma licatlon';` f . `: fan withVlcinit ,.Ma' ° ~sh`owlnh t. -`w Parkln' includln A ®A, ands. ` � . '- .lam 4 0 tails :',u:. L�andsca ,in F lan ,Grading�Plan�and�de ' "'° � � ' axe a -a, .at'k:.: a 1. ', ..� ar ., "u =: �,. ,'�: ..tea. s ^�:^sk. ^tea" � ^ - "',i;�' ^'SoilsRe , ort:, .if re , uired.,..,�,,�� u >r�;.�_, "Er ®sion. Control •PI`an``'and���details,,;,, ��:��_,..;�� .p,. (v q ) � Yf =$s�� .,"'. ,cam- r -� ., �- �`�`'v,�' "r� -: >�;: _� �ci. ,� � ;�,�; „ ^�, �” � "' ��`° � :��. ',.=� �. � °,,_ , <-�, ��a €.:, ",'' 43; *Does not apply to 1 and 2- family dwellings. P-Vitrat SAT T YR "E''.'.OF`SUBMITTL` °' "'A f^ °`':w.. ".. ncl u`des N e w;..AAdtlitions or Alferatio'ns)�;e. ,'.' - `,; `• ^ `_ ': :..�.. ` SA,u,brni.tta A Commercial 4 Multi - Family R -1 Occupancy 4 One- & Two - Family Dwelling 4 NOTE: Plan review is dependent upon submittal of a completed application and plans. After plan review approval, the Plans Examiner will contact the applicant to request additional sets of plans for distribution purposes (for Cont actor, City of Tigard, Washington County, and Tualatin Valley Fire & Rescue). ) P -G h is \dsts \forms \SIT- checklist.doc 01/29/03 FILE COPY July 18, 2003 X1 CD OF TIG .. '' John Abel OREGON Cornerstone Construction Management 5410 SW Macadam Avenue, Suite 250 Portland, OR 97239 RE: CFT ELEMENTARY SCHOOL Project Information Site Permit: SIT2003 -00014 Construction Type: ? Tenant Name: CFT Elementary Occupancy Type: E -1 Address: 12850 SW Grant Avenue /a gszr Occupant Load: Area: 67,500 Sq Ft Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The submitted plans are approved subject to the following. EROSION • Erosion control measures shall be in place prior to excavation or grading. FIRE • The private fire service main shall be at least 30 inches below grade. • The private fire service main shall be flushed thoroughly before connection to the system riser in order to remove foreign materials that might have entered the main during the course the installation. The flow rate shall not be less than the water demand rate of the system. • All piping shall be inspected prior to backfill. ACCESSIBILITY • Accessible walkways and routes shall not exceed a running slope of 1 unit vertical in 20 units horizontal (5% slope). Cross slopes shall not exceed 1 unit vertical in 50 units horizontal (2% slope). • Accessible parking spaces and access aisles shall be located on a surface with a slope not to exceed 1 unit vertical in 50 units horizontal (2% slope) in all directions. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 • i DEFERRED SUBMITTALS • The equipment cut sheets for valves controlling the fire service line have not been submitted and are considered a deferred submittal. The equipment shall not be installed prior to review and approval by the City of Tigard, Building Division. American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC which may not include all of the requirements of the ADA. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or please attach a copy of the - - - enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfull / Blab•4 enior ' Examiner • FILE COPY /00/ July 16, 2003 �^'^� ' I -I CITY OF TIGARD John Abel ®R ® N Cornerstone Construction Management 5410 SW Macadam Avenue, Suite 250 Portland, OR 97239 RE: CFT ELEMENTARY SCHOOL Project Information Site Permit: SIT2003 -00014 Construction Type: ? Tenant Name: CFT Elementary Occupancy Type: E -1 Address: 42850 SW Grant Avenue %a 8s'S Occupant Load: Area: 67,500 Sq Ft Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The revised plans have been reviewed and the following issues are in need of clarification: • The revised drawings from SLX/HBH dated 19 JUN 03 sheet C3 are in conflict with the HBH drawings dated 07 -09 -03 sheet C7. The private side of the Fire Fighting Supply lines are not indicated as to size and material on the HBH drawings and are arranged differently than the SLX drawings. • The FDC has not been indicated within 70 feet of a hydrant that is on the same side of the fire apparatus access roadway. This requirement was noted on the March 31, 2003 letter from the Deputy Fire Marshal. Clarify which drawings will be used for construction and make any necessary revisions. If you have any questions please call @ 503- 718 -2436 Provide 3 copies of revised drawings and please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respec lly, 13 • : lalock, -nior Plans Examiner 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 /�ima�alll�i�9�iQ�,j j1 , May 29, 2003 '' - 11 CI , i° OF TI :T 3 :. John Abel 7EGON Cornerstone Construction Management 5410 SW Macadam Avenue, Suite 250 Portland, OR 97239 RE: CFT ELEMENTARY SCHOOL Project Information Site Permit: SIT2003 -00014 Construction Type: ? Tenant Name: CFT Elementary Occupancy Type: E -1 Address: 12850 SW Grant Avenue Occupant Load: ? Area: 67,500 Sq Ft Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The submitted plans have been reviewed and the following information is required prior to the issuance of a Site Permit. 1. The accessible parking shown on sheet Cl does not provide an accessible route from the access aisle to the proposed structure. 1103.1 OSSC - 2. Complete the enclosed "TVF &R FIRE FLOW and HYDRANT WORKSHEET ". The allowable area permitted and the number of hydrants required will be based on the worksheet. 3. All portions of the building are required to be within 150 feet of Fire Apparatus Access Road. The Northwest side of the structure exceeds the distance. The Chief may modify the distance when the building is provided with an Automatic Sprinkler System. I will be in contact with Eric McMullen @ 503- 612 -7010 to discuss the issue. Call Eric if you have any questions. 4. The specification book makes several references to NFPA 24 for installation of the Underground Fire Service but give no design specifics. Provide details for thrust blocking, supply pipe burial depth, valve equipment cut sheets, etc. that are necessary for the installation of the fire service. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transm'ttal. The letter of transmittal assists the City of Tigard in tracking and processing the documents Respectfu Irian B1. .ck, Senior ' ans Examiner 131'25 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 TUALATIN VALLEY FIRE & RESCUE • SOUTH DIVISION ( COMMUNITY SERVICES • OPERATIONS • FIRE PREVENTION 'Tualatin Valli Fire & Rescu March 31, 2003 Brad Kilby, Associate Planner City of Tigard 13125 SW Hall Blvd Tigard, OR 97223 Re: C.F. Tigard Elementary Dear Brad, I have reviewed the submittal for the above named project and have the following comments: 1) FIRE APPARATUS ACCESS ROAD DISTANCE FROM BUILDING AND TURNAROUNDS: Access roads shall be within 150 feet of all portions of the exterior wall of the first story of the building as measured by an approved route around the exterior of the building. An approved turnaround is required if the remaining distance to an approved intersecting roadway, as measured along the fire apparatus access road, is greater than 150 feet. (UFC Sec. 902.2.1) Access exceeds the 150 feet maximum standard on the Northwest side of the building. Due to the fact the building will be provided with a full fire sprinkler system and complete fire alarm system, the Fire District will accept the current access layout. 2) FIRE APPARATUS ACCESS ROAD EXCEPTION FOR AUTOMATIC SPRINKLER PROTECTION: When buildings are completely protected with an approved automatic fire sprinkler system, the requirements for fire apparatus access may be modified as approved by the Chief. (UFC Sec. 902.2.1 Exception 1) 3) FIRE APPARATUS ACCESS ROAD WIDTH AND VERTICAL CLEARANCE: Fire apparatus access roads shall have an unobstructed width of not less than 20 feet (15 feet for one or two dwelling units and out buildings), and an unobstructed vertical clearance of not less than 13 feet 6 inches. (UFC Sec. 902.2.2.1) Where fire apparatus roadways are less than 28 feet wide, "NO PARKING" signs shall be installed on both sides of the roadway and in turnarounds as needeq, Where fire apparatus roadways are more than 28 feet wide but less than 32 feet wide, "NO PARKING" signs shall be installed on one side of the roadway and in turnarounds as needed. Where fire apparatus roadways are 32 feet wide or more, parking is not restricted. (UFC Sec. 902.2.4) 4) PAINTED CURBS: Where required, fire apparatus access roadway curbs shall be painted yellow and marked "NO PARKING FIRE LANE" at each 25 feet. Lettering shall have a stroke of not less than one inch wide by six inches high. Lettering shall be white on red or black on yellow background. (UFC Sec. 901.4.5.2) The curbs throughout the parking lots shall be painted as fire lanes. Please contact the Fire Marshal's Office for specific locations. 5) SURFACE AND LOAD CAPACITIES: Fire apparatus access roads shall be of an all- weather surface that is easily distinguishable from the surrounding area and is capable of supporting not less than 12,500 pounds point load (wheel load) and 50,000 pounds live load (gross vehicle weight). You may need to provide documentation from a registered engineer that the design will be capable of supporting such loading. Documentation from a registered engineer that the finished construction is in accordance with the approved plans or the requirements of the Fire Code may be requested. (Design criteria on back) (UFC Sec. 902.2.2) 6) TURNING RADIUS: The inside turning radius and outside turning radius shall be not less than 25 feet and 45 feet respectively, measured from the same center point. (UFC Sec. 902.2.2.3) 7) COMMERCIAL BUILDINGS - REQUIRED FIRE FLOW: The required fire flow for the building shall not exceed 3,000 gallons per minute (GPM) or the available GPM in the water delivery system at 20 psi, whichever is less. A worksheet for calculating the required fire flow is available from the Fire Marshal's Office. (UFC Sec. 903.3) 8) COMMERCIAL BUILDINGS - FIRE HYDRANTS: No portion of the exterior of a commercial building shall be located more than 250 feet from a fire hydrant when measured in an approved manner around the outside of the building and along an approved fire apparatus access roadway. Any hydrants that are left over from the minimum number of hydrant calculations may be full filled by hydrants that are up to 500 feet from any point of the building. The fire Prevention Ordinance has further requirements that need to be used for acceptance and placement of fire hydrants. (UFC Sec. 903.4.2.1) The number and distribution of fire hydrants is acceptable as submitted. The 250 feet maximum distance is exceed on the Northwest side of the school. Due to the fact the building will be provided with a full fire sprinkler system and complete fire alarm system, the Fire District will accept the current hydrant layout. 9) FIRE HYDRANT DISTANCE FROM AN ACCESS ROAD: Fire hydrants shall be located not more than 15 feet from an approved fire apparatus access roadway. (UFC Sec. 903.4.2.4) 10) REFLECTIVE HYDRANT MARKERS: Fire hydrant locations shall be identified by the installation of reflective markers. The markers shall be blue. They shall be located adjacent and to the side of the centerline of the access road way that the fire hydrant is located on. In case that there is no center line, then assume a centerline, and place the reflectors accordingly. (UFC Sec. 901.4.3) 11) FIRE HYDRANT /FIRE DEPARTMENT CONNECTION: A fire hydrant shall be located within 70 feet of a fire department connection (FDC). Fire hydrants and FDC's shall be located on the same side of the fire apparatus access roadway. (UFC Sec. 903.4.2.5) FDC locations shall be approved by the Chief. (1996 Oregon Structural Specialty Code, Sec. 904.1.1) The location for the FDC on the submitted plans is not within 70 feet of a fire hydrant and is not approved. If fire hydrants are plumbed from the fire line serving the building, the FDC shall be connected inside the building on the sprinkler riser, above all control valves. 12) FIRE DEPARTMENT CONNECTIONS ON BUILDINGS: Fire department connections shall not be located on the building that is being protected with the exception of Group R, Division 1 Occupancies not over 4 stories in height. (UFC Sec. 903.4.2.5) 13) ACCESS AND FIRE FIGHTING WATER SUPPLY DURING CONSTRUCTION: Approved fire apparatus access roadways and fire fighting water supplies shall be installed and operational prior to any other construction on the site or subdivision. (UFC Sec. 8704) 14) KNOX BOX: A Knox Box for building access is required for this building. Please contact the Fire Marshal's Office for an order form and instructions regarding installation and placement. (UFC Sec. 902.4) Please contact me at (503) 612 -7010 with any additional questions. Sincerely, Eric T. McMullen Eric T. McMullen Deputy Fire Marshal Ji - J-j/L ‘ 24 • PAGE 01 HBH CONSULTING 06/24/2904 12:54 5036700548 • ' C o n s u I t i n 11515 SW Durham Road, Suite E- 9.Tii4rd, Oregon 97224 503/670 -0499 • fax 503/6741 June 24, 2004 j Skanska USA 2555 SW 153' Drive FILE � Beaverton, OR 97006 Attn: Steve Jones, CF Tigard Construction Site By fax: 503- 620 -33 i Re: lnst?itlation of 72 -inch Sediment Manhole _ S Il ad'ro Dear Steve, This letter is to certify that the installation of the 72 -inci sediment Engineers, mol and manhole was installed as per modified plans issued by HBH Consulting g by the City of Tigard. i If you have any questions or comments, please contact ride. Sincerely, i i o ting Engineers, Inc. Robert M. eery, PE Project Engineer • ■ t 't Civil ■ Municipal • Environmental • Water Wastewater'• Stormwater • Transportation Z - d OEEE 13Ci'_i3Sd1 dH Wd6 : T I t t7Z unC CITY OF TIGARD 24 -Hour BUILDING Inspection Line: (503) 639 -4175 INSPECTION DIVISION Business Line: (503) 639 -4171 MST BUP Received D Re uested ° AM PM BUP Location Suite MEC Contact Person /71 � S 3 Ph ( ) PLM Contractor Ph ( ) SWR BUILDING Tenant/Owner ELC Footing Foundation ELC Access: Ftg Drain ELR Crawl Drain Slab Inspection Notes: SIT "ZC - Can (4 Post & Beam Shear Anchors Ext Sheath /Shear Int Sheath/Shear Framing Insulation Drywall Nailing Fi rewal I Fire Sprinkler - Fire Alarm Susp'd Ceiling - Roof 1W1 Other: ' " r Final / P /.\\ ASS PART FAIL PLUMBING Post & BeamMPA,I- Under Slab Rough In I �7 /011,‘ Water Service Sanitary Sewer I -r Rain Drains Catch Basin / Manhole � Storm Drain 1 Shower Pan Other: Final PASS PART FAIL MECHANICAL Post & Beam Rough -In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough -In UG /Slab Low Voltage Fire Alarm Final Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd. PASS PART FAIL SITE Please call for reinspection RE: Unable to inspect - no access Fire Supply Line ADA Approach /Sidewalk Date Inspector Ext • - - . F' DO NOT REMOVE this inspection record from the job site. PASS 'ART FAIL