LUEY ARCHITECTS PROJECT MEMORANDUM
Architecture and Planning
Project Name: Tigard Elementary School Remodel Date: June 10, 1996
Project Number: 9523/9524
To: Mr. Jim Funk
City of Tigard
13125 SW Hall Blvd
Tigard, OR 97223 / g 612/11t
Subject: Plan Review Comments Response (PC3 -95C BUP96 -0146)
Copies: File By: Jim Wright, Luey Arch
For your consideration, our responses to your plan review comments follows:
Comment:
En 'rgy
Submit completed Forms 5a, 5b, 5c, and 5d from an Energy Code Compliance Manual (Revised
January 1993). RECEIVED
Response: JUN .1 1 1996
1. Energy Code Compliance forms are included with this memo. COMMUNITY DEVELOPMENT
Comment:
Accessibility
A sum equal to 25% of the total project cost shall be expended in eliminating existing architectural
barriers to persons with disability (OSSC, Section 3112). Consult ORS 447.241(4) for priority in
spending. Provide the budget amount and the project roster (see below).
Res nse:
OSSC, Section 3112 states that:
"Every project for renovation, alteration or modification of buildings, including apartment
buildings, and their related facilities required to be accessible by the chapter shall eliminate
architectural barriers up to an expenditure of 25 percent of the total project cost, inclusive of the
cost of eliminating architectural barriers.”
OSSC, Section 3102 definition for alteration states:
"Alteration is a change to a building or facility made by, on behalf of, or for the use of, a
public accommodation or commercial facility, that affects or could affect the usability of the
building or facility or part thereof. Alterations include, but are not limited to, remodeling,
renovation, rehabilitation, reconstruction, historic restoration, changes or rearrangements in the
plan for configuration of walls and full- height partitions. Normal maintenance, reroofing,
painting or wallpapering, or changes to mechanical and electrical systems are not alterations
unless they affect the usability of the building or facility."
2. Per the definition quoted above, 81% of the cost involved with this project is for "normal
maintenance" items and therefore not considered as a part of the alteration budget. Out of the
Suite 301, Tigard Plaza • 11945 S.W. Pacific Highway • Tigard, OR 97223 • (503) 684 -3622 • FAX: (503) 684 -5999
LUEY ARCHITECTS PROJECT MEMORANDUM
1 Architecture and Planning
remaining 19% that is being spent on alterations, 44% is being spent on ADA improvements.
Please refer to the attached budget for a detail breakdown.
Comment:
Accessibility
1. The width of the aisle for turns around an obstruction shall be no less than 42 inches (OSSC,
ADAAG Figure 7). The screening wall for Boys Restroom 2A and Girls 4A must be set back.
Response:
1 (
7 Figure (a) allows a 36 inch width when makin g 90° turns. We feel that the condition at these
g
restrooms should be considered as 2 -90° turns rather than a 180° turn and therefore meets the 90°
turn requirements of Figure 7 (a).
Comment:
Accessibility
2. A door swinging into a restroom shall not swing into the clear floor space of any fixture (OSSC,
Section 3109(j). Correct swing of door into Restroom 7B, 40, and 33C.
Response:
1. Restrooms 7B, 40, and 33C are not being remodeled to accessible standards. Since we are at
44% for ADA improvements we are not required to make these improvements. Also, to make the
necessary accessible revisions would require us to reduce the number of plumbing fixtures for
the entire school to below code requirements for this occupancy.
Comment:
Accessibility
3. The minimum clear open width of a doorway is 32 inches. Correct openings at Restroom 11C
and 11A.
Response:
1. We have field verified the dimensions for these openings. The drawings were incorrectly drawn,
they are 41 inches rather than what was shown.
Comment:
Accessibility
4. The sink in each classroom shall be accessible in accordance with OSSC, Section 3109(k) 3.
A . Correct Detail 4/4.
Response:
1. Since we have already exceeded the 25% requirement, we are not required to make each
classroom's sink accessible.
Page 2
• LUEY ARCHITECTS PROJECT MEMORANDUM
Architecture and Planning
•
2. Detail 4/4 has been revised by lowering the height to 34 inches which allows side access to the
sink. This will allow accessibility by side approach as defined by OSSC, Section 3109(b)2B,
Section 3109(b)2F, and ADAAG Figure 6(c). We have not found a specific reference to this type
of sink in OSSC, Section 3100.
Comment:
Accessibility
S. Staff Restroom 40 shall be accessible.
6. Restroom 33C and 34C shall be accessible and a toilet stall not less than 48" wide provided in
each restroom [OSSC, ADAAG Figure 30(b)].
7. Restroom 17A -A shall be accessible.
8. The toilet facilities in the room next to Head End Room 41 shall be accessible.
Response:
1. Since we exceed the 25% requirement for ADA improvements we are planning on making these
improvements. Also, to make the necessary accessible revisions would require us to reduce the
number of plumbing fixtures for the entire school to below code requirements for this
occupancy.
Comment:
Fire and Life Safety
1. Provide the exiting /floor plan for the gymnasium.
Response:
1. No work is being done in this area other than mechanical maintenance upgrade since the school
district has decided to not take the alternate for refinishing the gym floor.
2. Since it is not totally clear on the plans, we want to briefly summarize the exiting plan for the (2)
gymnasiums. Gymnasium 39 exits to the outside on the north and east. Gymnasium 38 exits into
Gymnasium 39 and then to the outside on the north, and into Corridor 32 on the south.
Comment:
Fire and Life Safety
2. Provide a cross - section of Corridors 6A, 2A, 3A, 30, 31, and illustrating the one -hour fire -
resistive corridor construction, wall height, and light fixtures.
Response:
1. Please refer to the enclosed section from the existing building drawings. The corridor ceiling in
Building "A' will be changed to a 1 -hour suspended acoustic ceiling. The corridor ceiling for
Building "C" is existing and should not require any modifications.
Page 3
, LUEY ARCHITECTS PROJECT MEMORANDUM
Architecture and Planning
Comment:
Fire and Life Safety
Provide smoke detectors and strobes in all restrooms open to the fire -rated corridor (see
Restroom 2A and 4A).
Response:
1. Drawing E2 shows a strobe in each of these restrooms. The smoke detectors are located in the
corridor which are a part of the same atmosphere.
Comment:
Fire and Life Safety
. Smoke detectors shall be installed throughout the common atmosphere through which the exiting
for Classrooms 13 and 10 must pass [OSSC, Section 3318(d)]
Response:
1. Drawing E3 shows smoke detectors at the common atmosphere locations for Classrooms 13 and
10.
Comment:
• e and Life Safety
Submit a complete fire alarm permit application and three (3) sets of plans, battery calculations,
and cut sheets of devices specified. 1 Res onse:
apply p
t The contractor will a 1 for this permit.
C o ent:
S t ctural
Structural elements (joist and rafters) supporting the weight of the U.V. steam coil equipment
shall be reviewed by a licensed engineer. Provide the engineer's analysis.
Response:
1. Please refer to the enclosed attachment for this information.
Comment:
Mechanical
1. Provide smoke detectors in the 10,000 CFM, 12 -zone heating and ventilating system, Building
"A" in accordance with OSSC, Section 1009 (a) (b).
Page 4
LUEY ARCHITECTS PROJECT MEMORANDUM
Architecture and Planning
Response:
1. Please refer to the enclosed attachment documenting a previous conversation with you by Allen
Crisanaz with MKE & Associates, Inc..
Page 5
1 -29 71996 9: 26AM FROM WDY. I NC 503 +7683929 P. 3
.‘ ' ' N'' --. : . / . , .**:: .. . ; ;.. 7.4 11
•
' OAK
P1 sT• Asy°y'r
w_ t _... ou t7,,�_..•._ _ ,. _ • sr
..`.to IL%aG' 4,1 ... _ ... ` --- -... . - ,?
3)14-0 fCr C.
..! -� _ ► l
�5 l -
r , ♦ a. u t It- Fw-ibm
e
5T__ANI. - . p
•, G jG al e. t •
p»r) g X40 w/ A'35- •
` 4 M1
Gi,
fh • • $) F 3� 1'sr 1/.4-we, 4
t LA4GS 1 L4 1 1 p Yd's L V) t 14Naw'/
! )44-3M� N
f 4 r ?
fw
,11.• i r MO' • jm••.\.+ • • ^ .- 1 -. �.�w - . 60tr • ..- ' - �_ V __ • . .•-.. . s -.._ . .
Q
i . 1 .
•
•
.
.• , Og
• 23 vv-
I �A • _f
1 -29 -1996 9 :25AM FROM WDY,INC 503+7683929 P -2
r.. • L "t ,' Vc6 . , TnL ATOR.
n ,
1 �,_ 1_ _ „
,.,ii \: 69 .
..�j : N. •
1 c.7.1 . ^+ I
_ . •
, €4 . .
tof- • . 1. c 1 _ , .
. +1! , , .. . , 0 xo--- : •
, ,
4 41111111111111h . ' 7 . -1
i l 0 "--.--r -0 6 - , : t I
:r_ +4-4..t.- 1 . � �._ _ w1 � i
i i.. ..'• -* 4 __ ; 1. •
..._ ir ,. S . ..y •
i li vrAire
v. V , ,
o� � �-� i
.1 ' 1 Ii ' , 1
I. ' • 2X4 w/ 115 1;wirse
ri
i t ~ 4
i t i ; e -t 1 o F�.�.fi - 1 � �i� ri
.1 • Cam! p . 144 •
•
.i' • lj (z) ws-r- +
{1 : 1 )4iabt -i9 L:
A-''1`t Axel 1 eh
- . ♦ • :. r,Y„ti A ±- — "?. .. r.. Y. :...zry 6 .ti � 2:- 7ri �`i= .4t.a.y •(-.0 • • . • ... .Z.... • r a a•-••, ^
{ .. / ' _ i
1 •`..r •$ ti's : 1 • 1
H 1 !'C tiu>H ... • _ __
r
it
�
� 1
JUN, 7.1996 3:10PM - NO.447 'P.1 /1 '
MICE 6 Associate, Inc.
Consulting Engir)eers,
June 7, 1996 • -
' Mr. James Funk ,; , , ;
Plans Examiner - ,
CITY OF TIGARD -
13125 SW Hall Blvd. . ,
Tigard, OR 97223 • ' ,
SUBJECT; 'Tigard Elementary Schaol '
12805 SW Grant Street , ' ,
. PC3 -95C BUP96 -0146 , , . , '
•
. Dear Mr, Funk, , . •
This letter is to confirm our conversation on June 7, 1996 regarding the 10,000 cfm multi -zone unit in Building "A"
. at the school, '
As I stated in that ponversation, the multi -zone unit is an existing air handler. -The only work being done to it is
maintenance in nature, i.e., replacing zone damper actuators as required to air balance to each zone. '
If you have any questions, please feel free to call.
' Sincerely, , " '
. (2. . . , , , .. ,
Allen Crisanaz, P, '
Project Engineer
AC/vs , . ,
7110 loop; Suite 140 • Portland, Oregon 9723 ,
Telephone (503) 620 -7675 • FAX (503) 598 -8869
0
•
•
MKS" & Associates, Inc.
Consulting Engineers
•
•
June 7, 1996
Mr. James Funk
Plans Examiner
CITY OF TIGARD
13125 SW Hall Blvd.
Tigard, OR 97223
SUBJECT: Tigard Elementary School
0, g- 4-2.805.SW Grant Street
PC3 -95C BUP96 -0146
•
Dear Mr. Funk,
This letter is to confirm our conversation on June 7, 1996 regarding, the 10,000 cfm multi -zone unit in Building "A"
at the school.
As I stated in that conversation, the multi -zone unit is an existing air handler. The only work being done to it is
maintenance in nature, i.e., replacing zone damper actuators as required'to provide air balance to each zone.
If you have any questions, please feel free to call.
Sincerely,
Allen Crisanaz, P.E.
Project Engineer
AC /vs
•
7110 S.W. Fir Loop, Suite 140 • Portland, Oregon 97223
Telephone (503) 620 -7675 • FAX (503) 598 -8869
A lt:
a i,� jyp�'4l� @�p ll+
CITY OF TIGARD
May 13, 1996 OREGON
Luey Architects
11945 SW Pacific Highway #301
Tigard, OR 97223
Re: TIGARD ELEMENTARY SCHOOL
12805 SW Grant Street
PC3 -95C BUP96 -0146,
The plans and specifications have been reviewed for conformity to
applicable codes. Please submit three (3) sets of revised plans
and specifications incorporating the following requirements:
- •ergy
A° • Submit completed Forms 5a, 5b, 5c, and 5d from an Energy Code
Compliance Manual (Revised January 1993).
Accessibility i
A sum equal to 25% of the total project Lost shall be expended in fir,
\3 eliminating existing architectural barriers to persons with
disability [OSSC, Section 3112]. Consult ORS 447.241(4) for
" priority in spending. Provide the budget amount and the project
a C. roster (see below).
3 1. The width of the aisle for turns around an obstruction shall
® be not less than 42 inches [OSSC, ADAAG Figure 7]. The
screening wall for Boys Restroom 2A and Girls 4A must be set
ti I back.
. -
2. A door swinging into a restroom shall not swing into the clear
N. floor space of any fixture [OSSC, Section 3109(j) 2]. Correct
% `- \ swing of door into Restroom 7B, 40, and 33C.
As 14 \
'" '■ The minimum clear open width of a doorway is 32 inches.
Q j \, Correct openings at Restroom 11C and 11A. 1
4. The sink in each classroom shall be accessible in accordance
with OSSC, Section 3109(k) 3.
:,_ A. Correct Detail 4/4.
4' I
N �
i
3125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 {40:
Ilk
Luey Architects
May 13, 1996
pg. 2
Staff Restroom 40 shall be accessible.
4
A. The one employee restroom room shall have unisex signage
mounted on the wall adjacent to the latch side of the
door 60" above finish floor. Finish, color, braille
characters and pictorial symbol signage shall comply with
accessible requirements of Section 3109(o). A privacy
lock and an "Occupied" indicator shall be provided [Table __
5E(1)] .
d Restroom 33C and 34C shall be accessible and a toilet stall
not less than 48" wide provided in each restroom [OSSC, ADAAG
Figure 30(b)].
4. Restroom 17A -A shall be accessible.
A. The restroom shall have unisex signage mounted on the
wall adjacent to the latch side of the door 60" above
finish floor. Finish, color, braille characters and
pictorial symbol signage shall comply with accessible
requirements of Section 3109(o). A privacy lock and an
"Occupied" indicator shall be provided [Table 5E(1)].
' =''
l:. The toilet facilities in the room next to Head End Room 41
shall be accessible.
Fire � and Life Safety
l /,° wvyh t 9. 44t(4
1. Provide the exiting /floor plan for the gymnasium.
1
ci , Provide a cross - section of Corridors 6A, 2A, 3A, 30, 31, and
32 illustrating the one -hour fire - resistive corridor
'J (�� construction, ceiling construction, wall height, and light
k ke . h' fixtures. L,,. I I Lox / i ' q
e ".L' i
, � � Provide smoke detectors and strobes in aLl._ies oom open to
♦fie In the fire -rated corridors estr 2A and 4A)�
r ,, V -- ----- :
0 Smoke detectors shall be installed throughout the common
atmosphere through which the exiting for Classrooms 13 and 10
bY` Ve must pass [OSSC, Section 3318(d)].
5. Submit a completed fire alarm permit application and three (3)
sets of plans, battery calculations, and cut sheets of devices
547 specified.
a , -fr /./e,1,77,14 •
Sr I
IF"'
Luey Architects
May 13, 1996 .
pg. 3
4P
Structural
P 9)19°)(73/4
r�
,` Structural elements (joist and rafters) supporting the weight
of the U.V. steam coil equipment shall be reviewed by a
licensed engi e-. Provide the engineer's analysis. Ally M
echanical 4 d1 � i / }'w ( G '%
Pro ide Zete ctors in the 10,000 � CFM, 12-zone heating and _- P'
vent'lat in - ystem, Building "A" in accordance with OSSC, kli-
Section 009 (a) (b) . Om .?
If you wish to discuss any of these items, please give me a call.
Sincerely,
fps
James Funk
. Plans Examiner
t
i
bup96- 0146 \pc3- 95c.doc `
'' }fig;
. !
`1
1
i
PROJECT 9523/9524 SECTION 08710
MARCH 19, 1996 DOOR HARDWARE
PART 1 GENERAL
1.01 SUMMARY
A. Section Includes:
1. Door hardware for new swinging doors.
2. Door hardware for existing swinging doors.
B. Related Sections:
1. Section 08110, Steel Doors and Frames: Steel swinging doors and steel
frames.
2. Section 08211, Flush Wood Doors: Wood swinging doors.
3. Section 08410, Aluminum Entrances: Aluminum swinging doors at
existing frames.
1.02 SUBMITTALS
A. Product Submittals:
1. Comply with requirements of Section 01300, Submittals.
2. Submit product data for each item of door hardware.
B. Hardware Schedule:
1. Submit five copies of the final hardware schedule.
2. Comply with construction progress schedule requirements.
3. Submit one copy of the final hardware schedule to each fabricator of doors
and frames within two weeks after acceptance of hardware schedule by
Architect.
C. Templates:
1. Furnish hardware templates to each fabricator of doors and frames within
two weeks after acceptance of final hardware schedule by Architect.
D. Keying Schedule:
1. Submit 3 copies of the keying schedule prior to ordering locks and
cylinders.
E. Installation Instructions:
1. Submit installation instructions for each type of hardware.
1.03 QUALITY ASSURANCE
A. Manufacturer Qualifications:
1. Obtain each type of hardware from only one manufacturer, except where
indicated otherwise in hardware schedule.
B. Supplier Qualifications:
1. Hardware supplier shall have furnished hardware in the same market area
as the project for a period of not less than 5 years.
2. Hardware supplier shall have in his employment an experienced
architectural hardware consultant who is available for project hardware
consultation to the Owner, Architect, and Contractor.
Tigard ES Remodel and Tualatin ES Remodel Section 08710, Page 1
PROJECT 9523/9524 SECTION 08710
MARCH 19, 1996 DOOR HARDWARE
1.04 DELIVERY, STORAGE, AND HANDLING
A. Packing and Shipping:
1. Tag each item or package separately, with identification related to the final
hardware schedule.
2. Deliver individually packaged hardware items at the times and to the shop
or site for installation.
3. Place sets of change keys in individual envelopes, tag keys, and plainly
mark keys with change number or symbol and door designation.
4. Assemble change key envelopes into one package and deliver to Owner.
5. Forward master keys and grand master keys by registered mail complying
with Section 01700, Contract Close -out.
B. Storage and Protection:
1. Provide secure lock up for hardware delivered to the site, but not yet
installed.
2. Control handling and installation of hardware items which are not
immediately replaceable, so that completion of work will not be delayed
by hardware losses, both before and after installation.
1.05 WARRANTY
A. Manufacturer's Warranty:
1. Provide mechanical operated overhead closer manufacturer's standard five
year written limited warranty against defective materials and labor.
2. Submit warranty on manufacturer's standard form setting forth terms and
conditions.
PART 2 PRODUCTS
2.01 MANUFACTURERS
A. Butts:
1. Hager.
2. Lawrence.
3. McKinney.
4. Stanley.*
B. Latchset, Locksets, Cylinders and Occupancy Indicator:
1. Schlage*
C. Surface Closers:
1. LCN.*
D. Stops and Holders:
1. Builders Brass Works.
2. Glynn- Johnson. *
3. Ives.*
4. Quality.
E. Exit Devices and Mullions:
1. Von Duprin.*
Tigard ES Remodel and Tualatin ES Remodel Section 08710, Page 2
PROJECT 9523/9524 SECTION 08710
MARCH 19, 1996 DOOR HARDWARE
F. Thresholds, Gaskets, and Weatherstripping:
1. National Guard.
2. Pemko.
3. Reese.*
G. Overhead Stops and Holders:
1. Glynn- Johnson.*
2. Rixson.
H. Silencers:
1. Builders Brass Works.
2. Glynn Johnson.*
3. Ives.
* Manufacturers specified in hardware schedule at end of this Section.
2.02 MANUFACTURED UNITS
A. Hand of Door:
1. Furnish each item of hardware for proper installation and operation of the
door swing as indicated on floor plan Drawings, including left, right, and
reverse bevel.
B. Butts:
1. Furnish butts with non - removable pins at out - swinging doors with locks.
C. Latch and Lock Sets:
1. Furnish latch and lock sets in Rhodes lever design by Schlage Lock.
2. Furnish locks and latches with curved lip strikes in matching metal and
finish.
D. Surface Door Closers:
1. Furnish closers which do not limit the door swing.
2. Furnish drop plates for narrow top rails.
3. Furnish liquid controlled closers with key -type regulating screws.
4. Furnish manufacturer's standard one piece cast arm at parallel arm
locations.
E. Exit Devices:
1. Furnish latch retractor where exit devices are listed at openings without
thresholds.
F. Manual Flush Bolts:
1. Furnish flush bolts with matching dustproof strikes and suitable floor
attachment screws.
G. Door Silencers:
1. Furnish three silencers for single acting single doors and four silencers for
single acting pairs of swinging doors.
2. Do not furnish silencers for doors with weatherstripping or gasketing.
Tigard ES Remodel and Tualatin ES Remodel Section 08710, Page 3
PROJECT 9523/9524 SECTION 08710
MARCH 19, 1996 DOOR HARDWARE
2.03 HARDWARE ACCESSORIES
A. Fasteners:
1. Furnish flat -head screws in finish to match adjacent hardware as required
for each hardware item.
2. Where available, provide concealed fasteners for hardware units which are
exposed when the door is closed.
3. Furnish fasteners which are compatible with both the unit fastened and the
substrate.
B. Keying:
1. Key entire project to the existing building master keying and grand master
system.
2. Furnish nickel silver keys in the following quantities:
a. Change Keys: Three keys each lock or cylinder.
b. Master keys: Three master keys and three grand master keys.
3. Stamp Keys and Key Blanks: DO NOT DUPLICATE.
2.04 FABRICATION
A. Hardware Mounting Heights (unless otherwise noted):
1. Top hinge: 5 inches header rabbet to top of hinge.
2. Bottom hinge: 10 inches finish floor to bottom of hinge.
3. Center hinge: Equal distance between top and bottom hinges.
4. Lockset/latchset: 40 inches finish floor to center of knob.
5. Deadlock/deadlatch: 60 inches finish floor to center of cylinder.
6. Push plate: 45 inches finish floor to center of plate.
7. Door pull: 42 inches finish floor to center of pull.
8. Other hardware: Heights as recommended by manufacturers.
B. Hardware Finishes in BHMA Numbers:
1. Exterior Butt Hinges: 652
2. Interior Butt Hinges: 652
3: Latch Sets, Locksets and Cylinders: 626
4. Surface Door Closers: 689
5. Door Stops and Holders: 626
6. Overhead Stops and Holders: 626
7. Exit Devices: 626
8. Removable Mullions: SP28
9. Metal Kick Plates: 630
10. Thresholds: 628
PART 3 EXECUTION
3.01 PERFORMANCE
A. Installation of Recessed Door Hardware:
1. Install recessed hardware and then remove and store recessed hardware in
a secure place during application of door and frame finish.
2. After completion of the door and frame finish, reinstall recessed hardware.
Tigard ES Remodel and Tualatin ES Remodel Section 08710, Page 4
PROJECT 9523/9524 SECTION 08710
MARCH 19, 1996 DOOR HARDWARE
B. Installation of Surface Mounted Door Hardware:
1. Anchor kick plates with oval -head full- thread screws, spaced uniformly at
a maximum of 5 inches on center at kick plate perimeter.
2. Anchor thresholds with a positive anchoring device or expansion shield
and anchor bolts.
3. Set thresholds in mastic.
3.02 COMPLETION
A. Operating Hardware Adjustments:
1. Check and adjust operating hardware and each door operation to ensure
smooth operation.
2. Lubricate moving parts with type of lubrication recommended by
manufacturer.
3. Use graphite or WD 40 if no other lubrication is recommended.
4. Replace hardware which cannot be adjusted and lubricated to operate
correctly.
5. Adjust door control devices to compensate for final operation of heating
and ventilating equipment.
B. Contract Close -out Adjustments:
1. Where hardware installation is made more than one month prior to
occupancy of a space or area, return to the work not more than 7 days prior
to occupancy, and make a final check and adjustment of door hardware.
3.03 HARDWARE SCHEDULE
A. Required Door Hardware
1. Furnish the following hardware groups for each door as indicated on the
Door Schedule, and as required for a complete project.
2. Include items listed and required for a complete project regardless of
omissions or conflicts in Contract Document.
QUANTITY ITEM NUMBER SIZE
Group 1
1 -1/2 Pr Hinges FBB179 4 1/2x4 1/2
1 Latchset D l OPD -RHO
1 Wall stop 60W
3 Silencers GJ64
Group 2
1 -1/2 Pr Hinges FBB179 4 1/2x4 1/2
1 Lockset D70PD -RHO
3 Silencers GJ64
Tigard ES Remodel and Tualatin ES Remodel Section 08710, Page 5
PROJECT 9523/9524 SECTION 08710
MARCH 19, 1996 DOOR HARDWARE
Group 3
3 Pr Hinges Reuse Existing
1 Closer 4111 Spring H -Cush
and blocking at existing transom stop
1 Exit Device 99NL x 1609 Strike
1 Cylinder 20 -021
Pr Flush Bolts FB6
1 Overhead Hold -Open 902H
1 Aluminum Threshold Existing
Group 4
3 Pr Hinges Existing
2 Closer 4111 SPRING H -CUSH x 18PA
and blocking at existing transom stop
1 Exit Device 99NL -OP
1 Cylinder 20 -021
1 Exit Device 99E0
1 Removable Mullion 4954
2 Pulls Existing
1 Aluminum Threshold Existing
Group 5
1 -1/2 Pr Hinges FBB168 4 1/2x4 1/2 NRP
1 Exit Device 99NL x 1606
1 Cylinder 20 -021
1 Closer 4111 -CUSH
1 Alum Threshold 279Ax437AxMSES 36"
1 Sill Weatherstrip 323C 36"
1 Set Weatherstrip 897B 17'
Group 6
1 -1/2 Pr Hinges FBB 179 4 1/2x4 1/2
1 Lockset D70PD -RHO
1 Closer 4111
1 Set Gasketing 897B 17'
Group 7
1-1/2 Pr Hinges FBB 179 4 1/2x4 1/2
1 Latchset D l OPD -RHO
1 Closer 4011 or 4111
1 Wall Stop 60W
1 Set Gasketing 897B 17'
Tigard ES Remodel and Tualatin ES Remodel . Section 08710, Page 6
PROJECT 9523/9524 SECTION 08710
MARCH 19, 1996 DOOR HARDWARE
Group 8
1 -1/2 Hinges FBB179 4 1/2 x4 1/2
1 Lockset L9486 x Occupancy Indicator x
XL 11 -580
1 Closer 4011 or 4111
1 Wall Stop 60W (Door M15 -A)
1 Overhead Stop 904S (Door M15A-A)
Group 9
1 Alum Threshold 279Ax437AxMSES 72"
(Remove existing threshold)
2 Sill Weatherstrip 323C 36
END OF SECTION
Tigard ES Remodel and Tualatin ES Remodel Section 08710, Page 7