Plans 11 ,r M630 501 6rai lt H l4 E001.005= 00i). 3 SPECIFICATIONS El UNIT SIZE- SERIES 018 -A /C 024 -B /C Operating Weight (Lb) 123 139 036 -A /C 139 127/160 ELECTRICAL Unit Volts —Hertz —Phase 208 - 230 -60-1 208 - 230 --60 -1 208 - 230 -60-1 208 - 230 -60-1 III Operating Voltage Range 197 -253 197 -253 197 -253 197-253 Unit Ampacity for Wire Sizing (MCA) 12.3/11.8 15.1/16.1 19 8 23.8/22.3 Min Wire Size 60 °C Copper (AWG)* 14 14 14 12 Min Wire Size 75 °C Copper (AWG)* 14 14 14 12 Max Wire Length 60 °C Copper (Ft)t 66 53/49 39 52/56 Max Wire Length 75 °C Copper (Ft)t 62 50/47 37 50/53 Max Branch Circwt.Fuse Size (Amps) 20 25 30 35 Compressor Rated Load Amps 9.4/9.0 11.4/12.2 14 7 17.9/17.7 M Compressor Locked Rotor Amps 49.0/48.0 61.0 73.0 105.0/86.0 Fan Motor Full Load Amps 0.5 0.8 1.4 1 4 COMPRESSOR AND REFRIGERANT Compressor Manufacturer Copeland/Bristol 1 Copeland /Bristol 1 Bristol Millennium /Bristol Compressor Type Reciprocating Scroll /Reciprocating R -22 Refrigerant Charge (Lb) 4.38/4.68 1 5.30/4.88 1 5.63 I 5.31/5.75 OUTDOOR COIL AND FAN • III Coil Face Area (Sq Ft) 9.38 12.27 12.26 12.26/12 85 Coil Fins per In— Rows — Circuits 20-1 -2 20-1 -3 20 1 -3 20-1_3 Fan Motor HP 1/12 1/10 1/4 1/4 Fan Motor RPM 1125 1100 1125 1125 Rated Airflow (CFM) 2000/1700 2100 2300 2300/3300 OPTIONAL EQUIPMENT Time -Delay Relay KAATD0101TDR II Interface Control KHAIC0101AAA Outdoor Thermostat KHAOT0301 FST Secondary Outdoor Thermostat KHAOT0201 SEC Cycle Protector KSACY0101AAA Standard /KSACY0101AM Mg Crankcase Heater Standard KAACH1201AAA/Standard Compressor Start Assist— KSAHS0901AAA/ Capacitor /Relay KSAHS0901 AAA KSAHS1101 AAA Compressor Start PTC N/A KAACS0201 PTC / N/A _ s ig il Sound Hood KSASH2001BRL TXV Kits (Hard Shutoff)** KSATX0601 HSO TXV Kits (RPB) KHATX0201 RPB 1 KHATX0301 RPB I KHATX0401 RPB 1 KHATX0501 RPB _ High- Pressure Switch KHAHI0101 HPS ill Low - Ambient Pressure Switch KSALA0201 R22 Low - Ambient Controller P251 -0083 (RCD) MotorMaster® Control 32LT660004 (RCD) Ball Bearing Fan Motor HC34GE231 1 HC40GE232 ill Filter Drier P504 -8083S Evaporator Freeze Thermostat$$ KAAFT0101 AAA Isolation Relay$# KHAIR0101AAA NI Liquid -Line Solenoid Valve KHALSO401 LLS . Thermostat, Auto Changeover, Non - Programmable, °F / °C 2 -Stage Heat, 1 -Stage Cool TSTATPPBHP01 -A Thermostat, Auto Changeover, 1 1 7 -Day Programmable, °F / °C 2 -Stage Heat, 1 -Stage Cool TSTATPPPHP01 -A Outdoor Air Temperature Sensor (For Programmable Thermostat) TSTATXXSEN01 -B Backplate for Non - Programmable Thermostat TSTATXXBBP01 ll Backplate for Programmable Thermostat TSTATXXPBP01 Thermostat Conversion Kit (4 to 5 Wire) —10 pack TSTATXXCNV10 See notes on page 4. 1 1 0 . -3- NOTES: 1.AIlow 30 in. clearance to service side of unit, 48 in. 4.Series designation is the 14th position of the unit above unit, 6 in. on one side, 12 in. on remaining side, model number. and 24 in. between units for proper airflow. 5.Center of gravity ®. 2.Minimum outdoor operating ambient in cooling mode is 55 °F max 125 °F. . 3.Maximum outdoor operating ambient in heating mode is 66°F. 1 AIR IN AIR AIR ! AIR DISCHARGE DISCHARGE '` DISCHARGE j FIELD POWER 3 /8 -IN. DIA • � • 1 SUPPLY CONN TIEDOWN � I II /g - IN. DIA HOLE WITH KNOCKOUTS II 1 1 /8 13. DIA KNOCKOUT (2) PLACES S IN I I AND 1 /g -IN. DIA KNOCKOUT . I I " r thi o . � nlululmu � FIELD CONTROL ,r,4),) II , SUPPLY CONN . AIR IN -Os- % I' Riij 7 /8 -IN. DIA HOLE 1 ,• im e • j ,. N ® 3 /8 - E i:1 � : � . J 1 I I LIN lNo. E C ON DIA N LIQUID AIR �� �_ K I "�� �� i ■ - DISCHARGE AIR IN H - - 2 7 /8" C G L M 1 D DIA VAPOR LINE CONN 1 1/ � _ -F 4 r•IF E A97599 DIMENSIONS (IN.) • UNIT MINIMUM MOUNTING SIZE SERIES A B C D E F G H J K L M N P PAD DIMENSIONS 018 A, C 22 -1/2 29 -15/16 3 -3/16 5/8 18 -1/2 4 -1/16 2 -3/4 15/16 8 -3/16 3 -5/8 7/16 9 -1/4 10 -7/8 11 -7/8 22 -1/2 X 22 -1/2 024 B - 22 -1/2 37 -15/16 3 -3/16 5/8 18 -1/2 4 -1/16 2 -3/4 15/16 8 -3/16 3 -5/8 7/16 10 -1/4 11 -1/2 14 -1/4 22 -1/2 X 22 -1/2 024 C 22 -1/2 33 -15/16 3 -3/16 5/8 18 -1/2 4 -1/16 2 -3/4 15/16 8 -3/16 3 -5/8 7/16 9 -3/4 11 -1/4 13 -1/2 22 -1/2 X 22 -1/2 7 030 C 22 -1/2 37 -15/16 3 -3/16 3/4 18 -1/2 4 -1/16 2 -3/4 15/16 8 -3/16 3 -5/8 7/16 10 -1/4 11 -1/2 14 -1/4 22 -1/2 X 22 -1/2 036 A 22 -1/2 37 -15/16 3 -3/16 3/4 18 -1/2 4 -1/16 2 -3/4 15/16 8 -3/16 3 -5/8 7/16 10 -1/4 11 -1/2 14 -1/4 22 -1/2 X 22 -1/2 036 C 30 27 -15/16 3 -3/16 3/4 23 -1/2 6 -1/2 2 -3/4 15/16 10 3 -5/8 7/16 11 -114 17 -1/2 12 -1/4 30X 30 042 A 30 37 -15/16 3 -1/4 7/8 23-1/2 6 -1/2 2 -3/4 15/16 10 3 -5/8 7/16 12 -3/8 17 -11/16 15 -3/4 30 X 30 048 A 3Q 37 -15/16 3 -1/4 7/8 23 -1/2 6 -1/2 2 -3/4 15/16 10 3 -5/8 7/16 14 15 -1/2 15 -5/8 30X30 060 A ' 30 27 -15/16 3 -1/4 7/8 23-1/2 6 -1/2 2 -3/4 15/16 10 3 -5/8 7/16 10 -5/16 17 -1/4 12 -3/4 30 X 30 1. ilE4 V. 1111r 111! lir or IT ir sr ir ing or iir w 1 v r sr ing vig sr r' I MODEL�NUMBER NOMENCLATURE In sliii P F 1 M N A 018 000 AAAA R. A Common Unit A Minor Engineering Change A Standard Unit A Standard Unit Electric Heater (kw) Nominal Capacity (Btu) 018 - 18,000 048 - 48,000 . 024- 24,000 060-60,000 il 030 - 30,000 070 - 60,000 036 - 36,000 071 - 60,000 riol 042 - 42,000 A —Original Series N- 208/230 -1 -60 M— Multipoise i 1— Standard F —Fan Coil ;1 Payne i 1 SPECIFICATIONS i UNIT SIZE- ' I 018 1 024 1' • 030 1 ,036 •1 .042" 1 048 1 060 1 070 1 071 Operating Wt (Lb) 96 112 120 127 146 157 175 201 195 d Refrigerant Metering Device Bypass Check - Flo - Rater;TXV Factory Installed on 071 Piston Size 55 63 70 76 84 88 96 101 — TXV Size' — — — — — — — — 5 ton COIL, 1t Rows and Fins Per In. 2 and 14.5 3 and 14.5 3 and 14.5 3 and i4 5 3 and 14.5 3 and 14.5 3 and 14 5 3 and 14.5 3 and 14 5 Face Area (Sq Ft) 2.23 2.23 2.97 2.97 3.46 4.45 5.93 7.42 7.42 , Configuration Slope Slope , Slope Slope Slope A A A A FAN ; Air Discharge CFM (Nominal) 650 850 1100 1300 1500 1700 2000 2000 1750 Motor Hp (PSC) Except 071 1/10 1/4 1/4 1/3 1/2 3/4 3/4 3/4 3/4 ICM 1 Filter (In.) 21 -1/2 x 13 21 -1/2 x 16 -3/8 21 -1/2 x 19 -7/8 21 -1/2 x 23 -5/16 The 071 size factory - installed TXV is hard shutoff, bypass flow -type for heat pump application. Hard start components required on outdoor unit when com- pressor is single phase reciprocating. F1 J r. t apt 41,0 Aq,,S fJ'.0110, 0, u ii�90CDs �` � W � ` `gi k ilc • CERTIFICAI ION• LISTING 1. ~ F �� US • E O ANDIO srAtioo T � TESTING: • INSPECTION R g ist v3 q, a CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. I. 1 —2— ■ Ili Ph, 111 MB ma TIS a JO MI Al JIB AI .111 Al Al JR AI AI MI TOP VIEW .. lel UNIT CONNECTION SIZES 7 43" DIA KNOCKOUTS SUCTION. 018, 024 - 5 /8" ID SWEAT, FOR LOW VOLTAGE 030, 036 - 3 /4" ID SWEAT CONTROL WIRING 042, 048, 060, 070, 071 • 7 /8" ID SWEAT o LIQUID' 3 /8" ID SWEAT 1 7 CONDENSATE PAN CONNECTIONS 3 /4" FPT 1" n NOTE: Series designation is the 14th position —.J iire Oh of unit model number - -22 1 /16" — I 1 3 /8" t 10 11 "-0.- 1 15/ 7 /8", 1 3/32 ", 2" DIA KNOCKOUTS FOR HIGH VOLTAGE POWER WIRING NOTE: Allow 21 In from front --► 1" '�— 77 8" B 15 /16 "�{ _ B for service II- 21/ " i _UTt I AIR i I + DISCONNECT OR CIRCUIT ALTERNATE I�' — BREAKER LOCATION 7 43" DIA KNOCKOUT - 3/ • • I FOR LOW VOLTAGE o I BLOWER, CONTROL, & ELECTRIC CONTROL WIRING ALTERNATE 7 / OPTIONAL FILED HEATER ACCESS PANEL 1 3 /32" 2" DIA CONVERTED RIGHT KNOCKOUTS FOR RETURN = HIGH VOLTAGE OPENING POWER WIRING (SLOPE COIL o COIL ACCESS PANEL LIQUID LINE LIQUID LINE UNITS ONLY) CONNECTION CONNECTION OPPOSITE SIDE _ 9 LIQUID LINE A --- - - - - -- -- o CONNECTION 4 l I I - - - - -__— _ — - I - - FITTING E I. ° I F{ C r 5 PANEL 3 1 /16" ° I i FOR 2 /g O ° 1 V4" . I MODULAR "r 72 SUCTION LINE •• - I UNITS • 5 C ® ° I NOTE: Modular units o CONNECTION o I I two- piece I MAX 10 7 /16" O " o � , 10 3/4" , 0 o 9 1/c2" O o 0 11 hs "" l I cabinet 1 • 1 �'I 1..___i CI) • 6 I :CO 0 `_ I + _DO °__'_— __ __ __ ° • i + 'rte — 1 "j OP SUCTION LINE 1 „ I _ 19 73j16 „OPENING I } ENING FILTER ACCESS CONNECTION t!— _i 2 1/2” D PANEL SLOPE COIL DETAILS ACCESS PANEL CONFIG FOR SLOPE COILS RIGHT SIDE VIEW INLET AIR CONNECTION LOCATIONS DOWNFLOW OR HORIZ FRONT VIEW SHOWN WITH "A” COIL SHOWN FOR UPFLOW RIGHT APPLICATIONS ililatli DETAILS CONNECTION LOCATIONS OR HORIZ LEFT APPLICATIONS DOWNFLOW APPLICATIONS FOR UPFLOW OR HORIZ APPLICATIONS A97022 DIMENSIONS UNIT COIL A B C D E SIZE TYPE In. In. In. In. In. 018 Slope 42-11/16 14 -5/16 12 -7/16 12 -5/16 10 -7/16 024 Slope 42-11/16 14 -5/16 12 -7/16 12 -5/16 10 -7/16 030 Slope 47 -5/8 17 -5/8 15 -3/4 15 -5/8 15 -518 036 Slope 49 -5/8 17 -5/8 15 -3/4, 15 -5/8 15-3/8 042 Slope 53 -7/16 21 -1/8 19 -1/4 19 -1/8 19 -3/16 048 A 49 -5/8 21-1/8 19-1/4 19-1/8 15-11/16 060 A 53 -7/16 21-1/8 19-1/4 19-1/8 19-1/2 070 A 59 -3/16 24-11/16 22 -3/4 22-11/16 25-1/4 071 A 59 -3/16 24-11/16 22 -3/4 22-11/16 25-1/4 • SLOPE COIL AIRFLOW AIRFLOW 2 . TVP ' /,s" (2 PLACES)' _ TYP (4 PLACES)' ID 4- 1" F I 3 +i^ i PRIMARY DRAIN TYP }I 3'/ (2 PLACES)' SECONDARY DRAIN SECONDARY DRAIN 1 s/ +s P RIMARY DRAIN ' PRIMARY DRAIN 1 Tg I: s /'°" • TYP' •„ f TYP' SECONDARY DRAIN .. I Lb2 SECONDARY DRAIN E- I2 If l P D • r _ TYP TYP' _�.' 1 , . 2 5 /8" TYP (4 PLACES)' TYP' (2 PLACES)' 1 13/�e" 2" 1 " /�°" Li 5 " -� 2 Y" TYP 7/,- - - /s, 5 „ /,a —� -...—F TYP• TYP• HORIZ LEFT UPFLOW DOWNFLOW HORIZ RIGHT (AS SHIPPED) (AS SHIPPED) (FIELD CONVERTED) (FIELD CONVERTED) AIRFLOW AIRFLOW • , 3 /8" 2 HORIZONTAL MOUNT LOCATIONS - DIMPLES PROVIDED IN TOP E I T TV IF 1136 N D A HORIZONTAL H HARDWARE E TO BE FFIIELD PROVIDE - 8 (4 pLACES)' (2 P CES)' SUPPLIED 111 , - - . SECONDARY DRAIN 4 1/4" SECONDARY DRAIN PRIMARY DRAIN T O 0 m O (` F PRIMARY DRAIN s /,s" PRIMARY DRAIN 0 _ ( 2 PLACES)' 1 3/° I II • TVP' SECONDARY GRAIN TYP ll 0 �,.,, SECONDARY GRAIN I O I o I F O E {IIII PRIMARY DRAIN 1 � • '"4- _ _ � O . O J LACES)TYP I O _J 1 � �w� 0 • _ _ I... 1 . /z. 1'." 5 � e s " J L „ s L /i"3 ' / ' s "�1� 5 ` TyYP,s "• � 5 %- 1 e" TYP TYP 1 TVP' TVP "� (2 PLACES)• TYP V _...1 7 %" -� 3 V" _ (4 PLACES)• —► 7 1 'h" ° ,a.. -•-•.- I-.- 435 TYP • TYP' HORIZ LEFT UPFLOW DOWNFLOW HORIZ RIGHT (AS SHIPPED) (AS SHIPPED) (FIELD CONVERTED) (FIELD CONVERTED) A -COIL A97023 DIMENSIONS Continued UNIT COIL F G Ht j SHIPPING WEIGHT SIZE TYPE In. In. In. In. Lb 018 Slope 18-1/8 18 -5/8 — 12 89 024 Slope 18-1/8 18 - 5/8 — 12 93 030 Slope 23-1/8 23 -5/8 — 17 112 036 Slope 23-1/8 23 -5/8 — 17 115 042 Slope 26 -15/16 27-1/2 — 19 135 048 A 23 -7/16 23-1/8 — — 146 060 A 27 -1/4 26 -15/16 — — 167 070 A 32 -15/16 32 -5/8 34-1/16 — 196 071 A 32 -15/16 32 -5/8 34-1/16 `- 195 1 Applicable to modular units only. IF IF Illf lir Er If Ilr _ iir _ ______,. isr r 11IF !if w 10 I . ...III-