Loading...
Correspondence MAR 12 2881 11:47 FR ZTEC 583 233 7889 TO 5836847297 P.01/02 /2/55 gt- 67a.w7 4 ZTec Engineers, Inc. Civil - Structural- Surveying 3737 S.E. 8 Avenue Portland, Oregon 97202 (5030 233 -8795 Fax (503) 233 -7889 John Md. Middleton,P,L'. F. -Mail • itec @Teleport.corn Ronald b. Sellards, P.E. Chris C. Fischborn, P.L.S. Dean P. Zarosinski, P.F.. • Faxsimile Transmission Date: March 12, 2001 Number of sheets including cover sheet : 2 To: Bob Poskin — City of Tigard Plans Examiner From: Ron Sellards, P.E. /111) Fax Number: 503 -684 -7297 Subject: Fire Restoration — 12155 SW Grant Comments: In the questions you have raised in your phone calls and faxes, I want to respond with the following: - • The insurance value of the work will be $256,000.00 The barrier removal improvement plan will include an ADA parking space, ADA upgrade of the restroom, and the changing of lever handle at the man doors. The H -2 occupancy will not exist with a UL rated paint booth. But rather the occupancy type should be F -2 or something similar. There is to be a f -2 space next to the fire repair space and nothing on the other side. The floor above is a mezzanine except for a small, enclosed office area at the head of the stairs. This area is approximately 245 sq. ft. The mezzanine area is about 900 + sq. ft. in a basic floor area of 3200 sq. ft. MAR 11:47 FR ZTEC 503 233 7889 TO 5036847297 P.02/02 • Bob Poskin City Of Tigard p_2_ • Do we need a second exit ? The stair to the roof area will be a vertical ladder through a roof hatch near the office on the second level. The vertical ladder not a stairs a such will be designed for a 250 lb. Load. The paint storage area will have a two hour walls and ceiling area The two hour walls will have 5/8" type X gypsum board each side nailed and placed as per gypsum associations. The Gypsum wall Specification will be GA File No. Wp 4135 or 4136. The floor ceiling combination will meet gypsum associations specification GAFile No. FC5107. With the classification of a F -2 occupancy, The maximum allowable area setout in table 513 a VN building is 12,000 square feet with two yards a maximum of 18,000 sq. ft. The building is 11,250 sq. ft. If you have further questions, please contact me. Ron Sellards, P.E. 1 2 e‘ - ' 7 / • ** TOTAL PAGE.002 ** MEMORANDUM CITY OF TIGARD, OREGON 00000 IML=Ma TO: Ron Sellards FROM: Bob Poskin j. DATE: January 30,2001 Subject: Fire Restoration —12155 SW Grant In reviewing the restoration plans, the following items require your attention: 1. Provide the insurance value of the work 2. Provide a barrier removal improvement plan. 3. This is an H -2 occupancy. In order to determine occupancy separation requirements, I need to know the occupancy groups on both sides of this space. 4. The floor above is not a mezzanine; rather, it's a floor, requiring two exits, set apart half the diagonal distance. 5. You indicate stairs to the roof area of the top of the paint storage room, this requires a design factor of 250# per square foot. 6. The paint storage area requires a 2 -hour occupancy separation, to include the ceiling assembly, and a 11/22-hour door. Provide a detail. 7. Based on the floor space as shown on the drawings, the maximum allowable area setout in Table 5B for a 5N building is 2500 Square feet. Provide details on how you intend to meet the allowable floor area