Loading...
Permit CITY OF TIGARD ELECTRICAL PERMIT ` ° l COMMUNITY DEVELOPMENT Permit #: ELC2011 -00609 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718 2439 Date Issued: 11/0212011 Parcel: 2S111DB14500 Jurisdiction: Tigard Site address: 15130 SW 93RD AVE Project: LATT Subdivision: KESSLER ESTATES Lot: 2 Project Description: Solar photovoltaic installation. Contractor: PARKIN ELECTRIC INC Owner: LATT, CHRISTOPHER H 14001 FIR STREET 15130 SW 93RD AVE OREGON CITY, OR 97045 TIGARD, OR 97224 PHONE 503 - 657 -4958 PHONE: FAX 503 - 557 -1059 FEES Quantity Description Date Amount 1 ea Services or Feeders - 200 11/02/2011 $100.70 Specifics: amps or less 1 crt Branch Circuits w /Purchase 11/02/2011 $7 42 Type of Use: SF Service or Feeder Class of Work: OTR 1 ea 12% State Surcharge - 11/02/2011 $12.97 Electrical Type of Const: Occupancy Grp: Total $121 09 Required Items and Reports (Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR Specialty Codes and all other applicable law All work will be done in accordance with approved plans This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days ATTENTION Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center Those rules are set forth in OAR 952 - 001 -0010 through OAR 9 2- 001 -0090 You may obtain - . • • • - ules olnath- stions to OUNC by calling 503 232 1987 or 1 800 332 2344 Issued By: 703k Permittee Signature: _� ! OWNER INSTALLATION ONLY The installation is being made on property I own which is not intended for sale, lease or rent OWNER'S SIGNATURE Date: CONTRACTOR INSTALLATION ONLY SIGNATURE OF SUPR. ELEC' Date: LICENSE NO. Call 503.639.4175 by 7:00 a.m. for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. From: .—, 11/01/2011 14:48 #053 P.002/004 Electrical Permit Applicati n \\ FOR OFFICE USE ONLY ti City of Tigard � N. Received ; - Phone: 503.718.2439 Fax: 5 3.59&V,60 C 13125 SW Hall Blvd., Tt g and Olt 972 t , \ D ate/S : ii a o .�� � _ A mill � , Plan Rev { . •• \� Date/13 : Other Permit: TIGARD Inspection Line: 503.639.4175 (�'C 't Date Ready /Sy: ® See Page 2 for Internet• www tigard- or.gov l` \ �) Notif M ` Supplemental Information � r a r, k .Y' ,.. TYIF'E °AFr, -U „ : 3yL VIR —❑ New construction Addition/aiterat ?n/replacement Please check all that apply (submit 2 sets of plans w /items checked below) ❑ Service or feeder 400 amps or more ❑ Building over three stories ❑ Demolition ❑ Other: where the available fault current ❑ Marinas and boatyards. -i.'.. exceeds 10,000 amps at 150 volts or Floating buildings _ - • i? fir'`' P ❑ r �Gnit�'q O .. �, U g g G. .•...,.... less to ground, or exceeds 14,000 ❑ Commercial -use agricultural 1- and 2- family dwelling ❑ Commercial /industrial ❑ Accessory building amps for all other installations. buildings. 0 Multi- family ❑ Master builder ❑ Other: ❑ Fire pump. 0 Installation of 75 KVA or nq � .0 T I ❑ Emergency system larger separately derived system. .. - ...,.,..,; ... -.,� . ..::.. .M.,.. , 04, ,:• -;-. ..,,. _. ,.- ,,.:,:,.; ❑ Addition of new motor load of ❑.. ,. Job site address: 15/ 30 %/�e. 100HP or more. occupancy. T ^ ❑ Six or more residential units. ❑ Recreational vehicle parks, City /State/ZIP: l �� t?/(Q �g q Q + -7.)2' ! ❑ Health -care facilities ❑ Supply voltage for more than ��� ��� 1 ❑Hazardous locations. 600 volts nominal. Suite/bldg. /apt. no.: Project name: 0 Service or feeder 600 amps or more. tr : ':.." :,, S,i '; ';'" S,OI 1:4,11 ., -, -, : = Cross street/directions to job site: Description ' —. :Plitt 1 Qty. I Fee. I Total I New residential single- or multi- family dwelling unit. Includes attached garage. Subdivision: Lot no.: 1,000 sq, ft. or less 168 54 4 Ea. add'l 500 sq, ft. or portion 33 92 1 Tax map /parcel no.: Limited energy, residential ' - - - DESCRIPTION: ' OF WORI{ - (with above sq. ft.) 75.00 2 / 4 Limited energy, multi- family 0 ) L .5 x(A) S 044- .1 S -g U %� residential (with above sq ft ) 75.00 2 Services or feeders installation, alteration, and/or relocation 200 amps or less 9 100.70 /OD, 7 11 2 '' ' „'PROPERTY( OWNER " -' -- ' '• ;1 : _ r Q : TI%NANT' - - 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 Name: CA / 1 S L 04 601 amps to 1,000 amps 301.04 2 Address: 1 5 is 0 S &) ? �' V vZ Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation, alteration, and/or City /State /ZIP:' d , d J oft. 9 7 y aP relocation Phone: (so ) y � , 2865 Fax: ( ) 200 amps or less 59.36 1 201 amps to 400 amps 125.08 2 Owner installation: This installation is being made on property that I own which is not intended for sale, lease, rent, or exchange, according to ORS 447, 449, 670, and 701. 401 amps to 599 amps 168.54 2 Branch circuits— new, alteration, or extension, per panel Owner signature: Date: A. Fee for branch circuits with above service or fe eder fee, ® 'APpi.ICCA "i(: ” coNrr_ ` st� l? _ 1 7, y � � ? ' - "�' ° each branch circuit 7 4 2 Business name: B. Fee for branch circuits without service or feeder fee, first 56.18 2 Contact name: branch circuit Each add'l branch circuit 7,42 2 Address: Miscellaneous (service or feeder not included) City/State/ZIP: Each manufactured or modula 67,84 2 dwelling, service and/or feeder Phone' ( ) Fax: : ( ) Reconnect only 67.84 2 Pump or irrigation circle 67.84 2 E - mail: Sign or outline lighting 67.84 2 , CONTRACTOR ' - Signal circuit(s) or limited- energy Business name: Parkin Electric panel, alteration, or extension. Page 2 2 Each additional inspection over allowable in any of the above Address: 14001 Fir Street Additional inspection (1 hr min) 66.25/ hr City /State/ZIP• Oregon City, OR 97045 Investigation (1 hr min) 66.25/ hr Industrial plant (1 hr min) 78.18/ hr Phone: (503) 657-4958 Fax: (503) 557.1059 Inspections for which no fee is 90.00/ hr specifically listed (1/2 hr mm) CCB Lic.: 3515 Electrical Lic.: 34 -4C Suprv. Lic.: 4241 -S ; - x "_;. ELE tRICA•h.`PERM T FLES :, , .,,,�'2C`� Subtote /� : g Suprv. Electrician signature, required: Plan review (25% of permit fee): Print name: David B Parkin Date: State surcharge (12% of permit fee): Oa . 9 7 TOTAL PERMIT FEE. f ,a i, Authorized Signature: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: Date: * Number of inspections allowed per permit. I t Building \Permus\ELC- PermitApp.doc 07/0100 440 4615T(11/05/COM/WEB v 0 o a:1; " ' ` ` =`�» Gutter Height- 20' Peak- 30' ( Sale Person- Chet (503)964 -7770 „,::‘,„„,,, 0_ A ' ' a RS ff' „,, „,,,,,, *,k ',1..VCn .:-.:,;n::''=.::'e , energy Property Line 90' co Contractor: • 20' , RS Energy, LLC T o 20915 SW 105th AVE Tualatin, OR 97062 503 -752 -2885 Client: Chris Latt ® ® 15130 SW 93' Ave. 32' Tigard, OR 97224 —° , : ,, ; : (503) 341 -2865 2` ' Project: a ` :: ^ 319 tti r.. ` - I Issue Date: r. f ®� 10/7/2011 1 4 Install Date: Alsemiwki 4_ x :: 66,6 � , \l ,_ Est. Oct. 26, 2011 ._ ti`, l-f= i;:, Scale: : -=` E . : •f - s Tilt - 30 1” = 10' 22'IW3 a ','tn +- is -'4,'. TOF- 79 Notes: %:::, :i- %1F,;, ; South - (14) SolarWorld 230 a„ ; `1szY,sSg, watt modules (14) SolarWorld 230 '`' v F` Fronius IG + 3.0 Inverter Breaker Watt Modules (3.22 kW) ° °` % ,, - Inv er o ! " #i 20 • - Single layer Comp. Roof E. Existing Meter - Trusses = 24" on Center SunRun Meter - Standoffs 24 "/48" Property Line 90' SITE PLAN a o ° S stem Information Labels o PV Module Ratings Inverter Ratings Photovoltaic DC Disconnect o Module Make SolarWorid 230 limrter Make Fronius Rated MPP Current = 7.68 A ON T I L I TY Module Model SM230 Mono Inverter Model IG PLUS 3.0 -1 UNI Rated MPP Voltage = 420 V Max Power = 230 W Max. Output Power = 3000 W Max. System Voltage = 591 V Hollis Miles 4 Open Circuit Voltage = 37.4 V Max. DC Voltage = 600 V Max. System Current = 10.20 A Sales Manager Max Power Point Voltage = 30.0 V Norminal AC Voltage = 240 V Photovoltaic AC Disconnect 281-854-1409 Short Circuit Current = 8.16 A Max. AC Current = 12.5 A AC Output Current = 12.5 A - - v Max Power Point Current = 7.68 A CEC limiter Efficiency = 95.5% Nominal AC Voltage = 240 V NOIIis.Mifes @Ontiiity.COm - Note: Min Module Vmp for location calculated to appox. 23.4V o O UUTt{ iTY; T RV1C� N _ . o O 2 Y C• pnglN -.- . 7 (( OCPD ) Junction I - INVERTER J B ox r1 . . ,l ;s ,_3 '` Modules in sis rie i 0 ., es i DC: ' ;?�'I •. T I G MAIN . ____ J --- SERVICE PANEL 1 O O O O BUILDING -. GROUNDING ELECTRODE Note: Maximum allowable distance on wire run O to maintain 2% or less voltage drop is approx. 170 ft. EQUIPMENT SCHEDULE REF DESCRIPTION PN NOTES 1 SOLAR P1 MODULE SW 230 MONO SOLARWORLD 230W MONOCRYSTALLINE MODULE 2 ARRAY HARDWARE PRO SOLAR 3 J -BOX (IF USED) TBD 4 AC/DC INVERTER IG PLUS 3.0-1 UNI FRONIUS IG PLUS 3000W INVERTER 5 GENERATION METER (IF USED) NA ONELINESTANDARD ELECTRICAL DIAGRAM 6 SOLAR OCPD TBD REQUIRED 240V, 2 -POLE, 20A CIRCUIT BREAKER (BACK -FED) PROJECT REF: RS Energy 7 SERVICE PANEL NA (EXISTING) SITE ADDRESS: Portland, OR CONDUIT & CONDUCTOR SCHEDULE SYSTBN SIZE 3.22KW REF DESCRIP. /CONDUCTOR TYPE CONDUCTOR GAUGE NUMBER OF CONDUCTORS CONDUIT TYPE CONDUIT SIZE 1 String of 14 Modules (SolarWorld 230W) A USE2 &BARE GROUND #10 /4NE 2/II Engineered by: Brian Cunnigham B THWN -2 #10 /IV 2113 -1-1 EMT 3/4" Date: June 24, 2011 C BARE GROUND #6 1 v , 0 THWN -2 #10 /lig 3 / EMT 3/4° NOT TO SCALE U