Loading...
Permit q CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit #: MST2009 -00198 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 Date Issued: 10/08/2009 TIGARD Parcel: 2S103DB10500 Jurisdiction: Site address: 13215 SW GENESIS LP Subdivision: Lot: Project: Riles Project Description: Replace existing deck. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 5 Parking Spaces: p Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 20 Smoke Dwelling Units: 0 Third: 0 sf Right: 5 Detectors: Total: sf Value: $13,272.70 Rear: 20 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Catch Basins: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Other Fixtures: 0 Tubs /Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: 0 Bckflw Prevntr: 0 MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn <100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn > =100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 0 0 -200 amp: 0 0 -200 amp: 0 W/ Svc or Fdr: 0 Ea add'I 500 sf: 0 20 1 -400 amp: 0 201 -400 amp: 0 1st W/O Svc/Fdr: Limited Energy: 401 -600 amp: 0 401 -600 amp: 0 Ea add'I Br Cir: 601 -1000 amp: 0 601 +amp- 1000v: 0 1000 +amp /volt: 0 ELECTRICAL - RESTRICTED ENERGY SF Residential Audio & Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: Owner: Contractor: Required Items and Reports (Conditions) RILES, JOHN R & SUZANNE B EDELEN CUSTOM DOORS & 13215 SW GENESIS LP WINDOWS INC TIGARD, OR 97223 700 NE 102ND AVE PORTLAND, OR 97220 -4005 PHONE: PHONE: 503 - 255 -6552 FAX: Total Fees: $559.36 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952- 001 -0010 through OAR 952- 001 -0100. You may obtain a copy of the rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. By: _ � Issued B ry ( A ill /LL\ Permittee Signature: / �A ' N lJ, ' . Building Permit Application 1 , GI c Residential RECEIVE FOR OFFICE USE ONLY r City of Tigard Rec •� Permit No.: • i��y • = 13125 SW Hall Blvd., Tigard, OR 97223 0 T Q 1 200 Plan Review Phone: 503.639.4171 Fax: 503.598.1960 �gy. 6.44- l0 • ' Other Permit: TIGARD Ins Line: 503.639 =,�� r•eReadyBy: _l f 1 " El See Page 2for 09 Internet: www.tigard-or.gov CITY OF fied/Method: l ( / � I Supplemental Information BUILDING DIVIS • (K2 TYPE OF WORK REQUIRED DATA: 1- AND 2- FAMILY DWELLING ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all w Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1- and 2- family dwelling ❑ Commercial/industrial Valuation: $ ❑ Accessory building El Multi-family Number of bedrooms: ❑ Master builder $ Other: . 0 ec 4. Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: /3a /S .5 (,J, G. en e s; . Lao.N New dwelling area: square feet City/ State/ZIP: -- r . ? „,,,,,,, / ok. 97223 Garage/carport area: square feet Suite/bldg. /apt. no.: Project name: R . / e s Covered porch area: square feet Cross street/directions to job site: Deck area: it 7o ter square feet -SW 1 15 +6 A bte Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: I Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: S id 3 Indicate the value (rounded to the nearest dollar) of all 05 C) 0 equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. Valuation: 1 2 a � � d Omit CXS;S :ne� 6 ec x e- in Sfa // / � ■ �/ Existing building area: square feet Z e a l ACe rrt e., f New building area: square feet I ER PROPERTY OWNER ❑ TENANT Number of stories: Name: Tr) h n c1.... zu q g i l eS Type of construction: Address: /3 a /s S ,w, G -enes. S L ✓, , t . Occupancy groups: City/State/ZIP: -r o12e° n cl7 a3 Existing: U Phone: (sz, - 6. y 6 Fax: ( ) New: ($ APPLICANT RI CONTACT PERSON NOTICE Business name: (de 1 x i e) : ,ses All contractors and subcontractors are required to be Contact name: �a ri �' fSts� licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: 700 p F l0 2 hd /q ,,,, e jurisdiction in which work is being performed. If the applicant is exempt from licensing, the following reasons City/State /ZIP: rf'Jg„Q/ oi 572 .o apply: Phone: (5 , 5 - 1 9 . , . . K 0 4 , 7 Fax:: (V) 3) ASS- De L2k, E -mail: N✓,e.44) RI_ (-(jC /to deers • ez,h CONTRACTOR Business name: SA me BUILDING PERMIT FEES* Address: (Please refer to fee schedule) City/ State/ZIP: Structural plan review fee (or deposit): i l Q , 5 L4 Phone: ( ) Fax: ( ) FLS plan review fee (if applicable): CCB lie.: 7 D ,26 ) • ItA •`\ Total fees due upon application: Amount received: Authorized signature t Thi permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: Y , ( / .0-50 Date: /d_ k 9. * Fee methodology set by Tri -County Building Industry Service Board. I:1Building\Permits\BUP -RES PermitApp.doc 11/6/07 440- 4613T(11 /02/COM/WEB) , Building Permit Application Checklist One- and Two- Family Dwelling FOR OFFICE USE ONLY City of Tigard Received Permit No 1 3125 SW Hall Blvd., Tigard, OR 97223 Associated Phone: 503.639.4171 Fax: 503.598.1960 Associated permits: 24- Hour Inspection Line: 503.639.4175 0 Electrical ❑ Plumbing ❑Mechanical T[ G A R D Internet: www.tigard - or.gov ❑ Other: THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Yes No N/A 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ ❑ ❑ 2 Zoning. Flood plain, solar balance points, seismic soils designation, historic district, etc. ❑ ❑ ❑ 3 Verification of approved plat/lot. ❑ ❑ ❑ 4 Fire district approval required. Name of district: . ❑ ❑ ❑ 5 Septic system permit or authorization for remodel. Existing system capacity ❑ ❑ ❑ 6 Sewer permit. ❑ ❑ ❑ 7 Water district approval. ❑ ❑ ❑ 8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ ❑ ❑ 9 Erosion control ❑ plan ❑ permit required. Include drainage -way protection, silt fence design and location of catch- ❑ ❑ ❑ basin protection, etc. 10 3 Complete sets of legible plans. Must be drawn to scale, showing conformance to applicable local and state ❑ ❑ ❑ building codes. Lateral design details and connections must be incorporated into the plans or on a separate full -size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site /plot plan drawn to scale. The plan must show lot and building setback dimensions; property corner elevations (if ❑ ❑ ❑ there is more than a 4 -ft. elevation differential, plan must show contour lines at 2 -ft. intervals); location of easements and driveway; footprint of structure (including decks); location of wells/septic systems; utility locations; direction indicator; lot area; building coverage area; percentage of coverage; impervious area; existing structures on site; and surface drainage. 12 Foundation plan. Show dimensions, anchor bolts, any hold -downs and reinforcing pads, connection details, vent size ❑ ❑ ❑ and location. 13 Floor plans. Show all dimensions, room identification, window size, location of smoke detectors, water heater, ❑ ❑ ❑ furnace, ventilation fans, plumbing fixtures, balconies and decks 30 inches above grade, etc. 14 Cross section(s) and details. Show all framing- member sizes and spacing such as floor beams, headers, joists, sub- ❑ ❑ ❑ floor, wall construction, roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing, roofing, roof slope, ceiling height, siding material, footings and foundation, stairs, fireplace construction, thermal insulation, etc. 15 Elevation views. Provide elevations for new construction; minimum of two elevations for additions and remodels. ❑ ❑ ❑ Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full -size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing (prescriptive path) and/or lateral analysis plans. Must indicate details and locations; for non ❑ ❑ ❑ prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor /roof framing. Provide plans for all floors/roof assemblies, indicating member sizing, spacing, and bearing ❑ ❑ ❑ locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ ❑ ❑ systems, see item 22, "Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ ❑ over 10 feet long and/or any beam/joist carrying a non - uniform load. 20 Manufactured floor /roof truss design details. ❑ ❑ ❑ 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas - piping schematic is required ❑ ❑ ❑ for four or more appliances. 22 Engineer's calculations. When required or provided, (i.e., shear wall, roof truss) shall be stamped by an engineer or ❑ ❑ ❑ architect licensed in Ore on and shall be shown to be a. +licable to the sro'ect under review. JURISDICTIONAL SPECIFICS 23 Three (3) site plans are required for Item 11 above. Site plans must be 8 -1/2" x 11" or 11" x 17". ❑ ❑ ❑ 24 Two (2) sets each are required for Items 16, 19, 20 and 22 above. ❑ ❑ ❑ 25 Building plans shall not contain red lines or tape -ons. "Mirrored" building plans will not be accepted. ❑ ❑ ❑ 26 "Reversed" building plans must meet criteria outlined in the Permit & System Development Fees document. ❑ ❑ ❑ 27 "Drawn to scale" indicates standard architect or engineer scale. ❑ ❑ ❑ 28 Site plan to include tree size, type and location per approved project street tree plan (if applicable), and City of Tigard ❑ ❑ ❑ Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations, driplines, ❑ ❑ ❑ and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services' Sensitive Area Pre - Screening Site Assessment form is required for all building additions, ❑ ❑ ❑ including decks, patio covers (over non - impervious surface) and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. I: \ Building \Permits\BUP- RES- PemtitApp.doc 03 /21/06 440.46t3T(11/02/COM/WEB) I'' _ . _ _ .. G(- 4 ' / / </_!at'[ • : r ✓/ r 1 r =' 1 ' I -... __..._ .. j . j I I 1 I ... _ 1 ,,. • i j , — I t I ! ' 1 y ' i I I , i i- _ . -- -- I . • , i • I I. : 1 1 iii I � i I I -. ' � 4 ,._ _ .. : i j I . I 2 ; ! I I I I I 1 1 I I • ! 1 ' . F'�IG 1 • 1 1 • I 1 I ILpING DID TOIL f I I .. i I ! � SI I I_ . ._ • I , iBU ;1 l - 1 i i ! -_ I ; • !- I 1 i ' I i 1 1 I j I 1 ! , I I I I • • I T I . • I 1 I i ' 1 1 I 1 1 1 I • j 1 I I i i 1 j I I 1 i l • j I I I I! I i I II HI i I 1 I 1 i } r , I Ili I ; I I i G5.5 i I 1' i 1 I 1 � 1 _ _ l ! 1 , _1 i 1 ! ! I �. i i ,I I , ' i 1 1 II I f , I ; �Q i I I i! ; ! I 1 I I I_ I I I I I I 1 1 I ! i I � I I ; . I ! I I I i � ! ! I 'II I .- 1 III I _ I _ I _ I 1 �� �! ; - I 1. , I i I! I I 1 I I I I i •' 1 I i ! 5 i �, i I I .I. 1IIi i I I I ., � 5 I I ...I o I • 1 1 , I ,S I � - j ■ , I I i I I i I I � to , l i ' : • • 1 ���;� I - I I I I i i I I i 1 I j 11 1 1 I 1 I I , ! I i 1 . 1 I I I :. < 1 ! I ; 1 , I I ,�1 1 I � 1 I 11 j i l l I 1 I ~ ' #' I . , If I � i • i I I l ! I I I I i • 1 _ai. I i_ 1 f I i 1 I �: j ! I ! I , s'¢ I I I i I , I 1 , I ' I I I I ;Ij;I • I l 1 I I �. I i . I f �: I • J a zl' I I . 1 1 I I 1 I • . I ;11 1 I i i 11 I I i ; I j I i I I I I I I 1 I I 1 I I I ,1 1 , , I I i I. 1 i •, 1 1 I I. I I _ . I I • • 1,I I I , • I f I I i I i Ij' ; I , I 1 i ; 1! !! il I!I1 ! I 1 :1' I 1 i 1.I I I i j 1 i , � I I i 1 ! I I I I i j I I I ! ! I j l I j .1 . „ 1 i j I I 1 I ! . . I i , .I III I 1�1 il i lllj I I , I , !III I , 1 1 1 1 1 1 I ! 1 I , 1, -` I I ! l .. I , i III! 1 1 j I i j I ! I r 1 I l l I . I I i ! i , 1 8 ' '.2, '1 .. 1 I I I I ' I •. �+, e5s Loo i , i ! _ . _' - I 1 • CITY OF TIGARD - SITE PLAN REVIEW BUILDING PERMIT NO.: 1111N • Oa q g PLANNING DIVISION: Required Setba ,j4/01 Approved"- 0 Not Aporoved Side: Street Side _g From. ee , Visual Clearance: 13 r 1. 1 Maximum Building 450 ■o: CWS Service Provider Letter Required 0 ' . yok Ca V6 la ■ikld e 69-(pi ENGINEERING EPARTMENT: Actual lope: % W Approved 0 Not Approved Site PI : VI 0 By: V Date: lel 2-- 0 9' Notes: -u_ed LIA4.4 CITY OF TIGARD - SITE PLAN REVIEW BUILDING PERMIT NO: PitSt 2 00q - 001 pproved 0 Not Approved Street Trees: G/Approved 0 Not Approved Protected Treo: — 7 — By: of, rs Date: I yro Notes: