( 1 City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 June 3, 2009 1111 • • • . RE: BUILDING PERMIT FOR NATIONAL SAFETY COMPANY T I GARD Project Information Building Permit: BUP2009 -00077 Construction Type: 5 -B Address: 7105 SW Gonzaga Occupancy Type: B Area: 10,400 Sq. Ft. Stories: 2 Name: National Safety Co. Sprinkled: Yes The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2007 edition; 2007 and Oregon Fire Code. Please provide the following conditions prior to issuance of the permit. 1) Please provide two complete sets of truss details with all connection details. 2) Please provide window and door schedules showing all hardware packages.C` 3) Provide construction details of exterior stairway with solid risers, handrail, s guardrail and landing. Provide nosing detail of interior stairs. 4) Provide details for attachment of brick veneer showing type of seismic clip to be used. 5) Provide construction details of awning above entry. 6) Provide completed energy, lighting and HVAC state compliance forms. C5 7) Provide engineered floor truss layout showing all nailing and blocking or - required. 8) Provide shearwall schedule showing all nailing, clips, straps and all general C notes. 9) Provide details of roof access required for HVAC equipment. c * -. 10)Provide installation details for any ceiling grid installation. C- 11)List uses of all rooms with purposed use and occupant loads. c. 12)Show construction of interior walls showing attachment to floor, ceiling andc<" connection of all walls to structure. 13)Designate a design professional in responsible charge of this project. C - 14) Provide a reflected ceiling plan showing exit signs, paths of egress and(4— egress lighting. 15)Construction documents shall contain sufficient details and dimensions showing the accessible routes and conformance to accessible design standards found in Chapter 11 OSSC. - 16)Please provide all interior finishes. C - 17)Provide type of roof covering and show all roof venting'',=- - 18)The construction documents shall indicate the location, nature and extent of the work proposed and show in detail that it will conform to the provisions of this code and relevant laws, ordinances, rules and regulations, as determined by the building official. 106.1.1 OSSC ]r F' T>Sc, Mcs l L — E rc 12 TRt1 - I\ LO P t c3G- Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard - or.gov • TTY Relay: 503.684.2772 This plan review is as complete as possible with the preliminary plans. When responding, provide an itemized letter stating in what way each numbered issue has been addressed in the revision. When submitting revised drawings or additional information, please attach a copy of the City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respec ully, 3tic7A.) an Nelson Senior Plans Examiner (503)718 -2436 dann @tigard - or.gov TRANSMISSION VERIFICATION REPORT TIME : 06/0912009 10:50 NAME : TIGARD BUILDING DEPT FAX : 5036243681 TEL . SER.# : BROD4J479592 DATE,TIME 06/09 10:44 FAX N0. /NAME 5036205338 DURATION 00:06:01 PAGE(S) 12 RESULT OK MODE STANDARD Post - It°" Fax Note 7671 Data 04I Pdg,sh City of Tigard, Grego l a M - From R o,in e - = Co. /Dept. Ca- 2009 �t,�'R� June 3, 2009 Phone # Phone ; 7 , -y II Fax # Fax # J' C L 0 IN RE: BUILDING PERMIT FOR NATIONAL SAFETY COMPANY TIGARD Project Information Building Permit: BUP2009 -00077 Construction Type: 5 -B Address: 7105 SW Gonzaga Occupancy Type: B Area: 10,400 Sq. Ft. Stories: 2 Name: National Safety Co. Sprinkled: Yes The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2007 edition; 2007 and Oregon Fire Code. Please provide the following conditions prior to issuance of the permit. 1) Please provide two complete sets of truss details with all connection details. 2) Please provide window and door schedules showing all hardware packages. 3) Provide construction details of exterior stairway with solid risers, handrail, guardrail and landing. Provide nosing detail of interior stairs. 4) Provide details for attachment of brick veneer showing type of seismic clip to be used. 5) Provide construction details of awning above entry. 6) Provide completed energy, lighting and HVAC state compliance forms. 7) Provide engineered floor truss layout showing all nailing and blocking required. 8) Provide shearwall schedule showing all nailing, clips, straps and all general notes. 9) Provide details of roof access required for HVAC equipment. 10)Provide installation details for any ceiling grid installation. 11)List uses of all rooms with purposed use and occupant loads. 12)Show construction of interior walls showing attachment to floor, ceiling and City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 June 30, 2009 I1 • IN • RE: BUILDING PERMIT FOR NATIONAL SAFETY COMPANY T I GARD Project Information Building Permit: BUP2009 -00077 Construction Type: 5 -B Address: 7105 SW Gonzaga Occupancy Type: B Area: 10,400 Sq. Ft. Stories: 2 Name: National Safety Co. Sprinkled: Yes The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2007 edition; 2007 and Oregon Fire Code. Please provide the following highlighted conditions prior to issuance of the permit. 1) Please provide two complete sets of truss details with all connection details. Provide details for connecting trusses to exterior walls. 2) Please provide window and door schedules showing all hardware packages. Provide details for egress at all exterior doors. 3) Provide construction details of exterior stairway with solid risers, handrail, guardrail and landing. Provide nosing detail of interior stairs. The stairway is considered accessible because of the elevator. OSSC 1108.1.1.4 If the interior stair has a open side you will be required to have a 42" guardrail as well as a 34" to 38" handrail. 4) Provide details for attachment of brick veneer showing type of seismic clip to be used. Seismic masonry veneer clips in seismic zone D shall be two piece Ohio - h Cf - according to OSSC 1405.5.2 and ACI. Please show listing of clip being used. 5) List uses of all rooms with purposed use and occupant loads. Provide total occupant load for first and second floor. 6) Construction documents shall contain sufficient details and dimensions showing the accessible routes and conformance to accessible design standards found in Chapter 11 OSSC. Provide heights for accessible lobby and break room sink counter. Inspector will verify all accessible standards required for this project. 7) Please submit revisions for site plan corrections list. 8) Provide planning department approval. (Al Shields (503) 718 -2426) 9) Provide engineering department approval. (Al Shields (503) 718 -2426) 10)Identify all special inspection required for the construction of this building. 11)The construction documents shall indicate the location, nature and extent of the work proposed and show in detail that it will conform to the provisions of this code and relevant laws, ordinances, rules and regulations, as determined by the building official. 106.1.1 OSSC Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 When responding, provide an itemized letter stating in what way each numbered issue has been addressed in the revision. When submitting revised drawings or additional information, please attach a copy of the City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfull , 4011111,.. War NV "■",•• an Nelson Senior Plans Examiner (503)718-2436 dann@tigard-or.gov 4() - 10C 0,-s 3010)4 p avirn r 'pl voyAf soc*t. 5 PA- 5 426 © crz-- Ne\ 06t,c, b .5Q Fr F(� d - •=;E_-N t " I S 1 L'S ,. _ ...q,_„*., s* A 4ThM arte l) FOWIMAUPCY2f> _ ____ 00 6 6:26:r . tre44:773 4,-- S ` s 1.•.---,kr(Z15"51 - 1 "FiE CF 114.40 F630E/ 2 0-6- r `' i -i+� � .f� — ; r,1 it - S kVt. MCI TV■S Kt T � r F cr {P €car t21-7.1 e 73 EL vitro -*46E u IL Cu Fs t Stec_ —� cam elp c— c i tk05, � 2- , Rgitok, IDIALWIFQ lSI — r i C t e- 2_ LO i2ST \ G? O - ( = u�� CO PR 5 � 44P-g-1 ---itiVC_L'SS Hi( _ J am- ► arm, ( PF weismill' DI" c' This form is recognized by most Building Departments in the Tri- County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. n BUILDING DIVISION TIGARD TRANSMITTAL LETTER a , `�, + TO: J L- �VrLI DATE RECEIVED: DEPT: BUILDING DIVISION FROM: M Ld4o ( M, L i CL-3 COMPANY: ID t -n4 v /Ltvlv f01,e. �a / 1rr .Mi+ec PHONE: � '224- b 7V 1 By: RE: ( 71 ©5 J G�tf►�'3t ( Pr , od7 Site Address) ermNCase Number Nt7ta1cr 4— c,� C . (Project name or subdivision name a lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description: Copies: Description: Additional set(s) of plans. Revisions: 4tads M"- A3 , c fwras( Cross section(s) and details. Wall bracing and/or lateral analysis. Floor /roof framing. Basement and retaining walls. 6 • (( •dI Beam calculations. Engineer's calculations. Other (explain): REMARKS: 1k _ KV1 c z itt.5 �� bur x;11 ( -Skaek (ss ..j OI .e- 3 mil. (so S ( se- Le. -e-a -hA wt se.t f 64,44. s v xitA.g(A. FOR OFFICE USE ONLY Routed to Permit Technician: Date: Initials: Fees Due: ❑ Yes ❑ No Fee Description: Amount Due: Special Instructions: Reprint Permit (per PE): ❑ Yes ❑ No ❑ Done Applicant Notified: Date: Initials: 1: \Buildin Forms \TransmittalLetter - Revisions.doc 4/4/07 July 21, 2009 Leonard A. Rydell, PE, PIS Rydell Engineering 601 Pinehurst Drive Newberg, OR 97132 RE: National Safety Building — PFI2009 -00019 / Redline No. 2 Thank you for responding to the first redline comments. A set of "redline" public improvement construction plans is attached. Please make the noted revisions and submit _3_ revised sets to this office for review, along with our original redline plan. If you disagree with one of our comments, you must submit a written explanation either on the redline plan or in a separate letter. If no explanation is provided, we will deem that you have not addressed the comment. 1.) Please show on all plansets (PFI, Site, Bldg) the building size and dimensions approved through Land Use. Land Use approval was for 5208 square foot building footprint (84' x 62'). East side yard setback: 17.68'. 2.) Remove existing 10" C -900 and existing ditch inlet in Gonzaga Street. Re -lay and extend 10" C -900 to proposed catch basin at the west end of Gonzaga Street frontage. 3.) TVF&R requires a hydrant on the north side of the street. FDC must be remote from building (see suggestion on red line set). 4.) Include street lighting sheet(s) with this planset. 5.) Include onsite sheets 3 (Private Storm Drainage) & 5 (Water Quality Swale Plantings) this planset 6.) Include construction cost estimate for street trees, street light(s), water quality /quantity construction and plantings. 7.) Please return all revised plansets (PFI, Site, Building). Please note: Submit revised plans to Albert Shields, Permit Coordinator, for intake review to ensure all items listed above have been met. Sincerely, Michael White Senior Engineering Technician Attachment is \ cng \pdvaa devdopmem psujeco \narional saFery building pf2 - -u(O79 \plan n•v cw (eedliae).dou 07/01/2009 18:37 503- 224 -5936 DTL ARCHITECTS PAGE 01 . DiBenedetto Thomson Livingstone FAX Transmittal Architects 0106 SW Gibbs Date: 3 r 0 Portkind OR 97239 (503) 224 -6767 Page 1 of Fall (503)224.5936 To: Da1A 0 Fax # 93 &04 - 77ct7 el e~E boirl From: L r i, !kit Fax # 503 224 -5936 Project Name /Number Kaltsvita cSace.6 G. 4- Bor 0.. &9 --o 7 7 • g,Q.s ci e4( J ki(y z, z607 • T- rem 07/01/2009 18:37 503 - 224 -5936 DTL ARCHITECTS PAGE 02 This form is recognized by most Building Departments in the Tri- County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. n BUILDING DIVISION 0 TIGARD TRANSMITTAL LETTER a TO: _Dif Nai Sale% _ - DATE RECEIVED: DEPT: BUILDING DIVISION FROM: COMPANY: DLe;talgits Ul PHONE: 50'5. 224-• (076,7 RE: (05 S f 1,0001. ono ttc seas) .ermi asc . um.et co - reject namc or su • tvtsian name an. um et ATTACHED ARE THE FOLLOWING ITEMS: Copies: , Description: CpieS: y Descriphan Additional set(s) of plans. ( Revisions: $_ (,) Cross section(s) and details. Wall bracing and/or lateral analysis. Floor /roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other (explain): _ REMARKS: Q . l 5_k 61n_.,,5 6.4-t C-o ' .4, � LA. a U , •sties _ c \ut FOR Routed to Permit Technician: Date: Initials: Fees Due: Yes No Fee Description: Amount Due: $. ` $ Special Instructions: Re • tint Permit . • r PE : • Yes ❑ No • Done A•.licant Notified: Date: Initials: r:\ auil dingworms\ TransmittalLcttcr- Rcvisians.doc 4/4/07 07/01/2009 18:37 503- 224 -5936 DTL ARCHITECTS PAGE 03 17i$�nedttn July 2. 2009 Thomson L ,stone Dan Nelson Azchatccts Senior Plans Examiner 0106 5W Gibbs City of Tigard 1'ortlnnd, OR 97239 (5 03) 224.6767 Re: Proposed Office Building at 7105 SW Gonzaga St., Tigard, Oregon Fax(503)224 -5936 Permit No BUP2009 -00077 Checksheet Response The following remarks are in response to your checksheet dated June 30, 2009 and are numbered accordingly. . 1. The truss manufacturer is typically responsible for the truss connection to the exterior walls. Because the roof trusses are a deferred submittal, the connection details will be submitted when the manufacturer has completed their design. 2. There are four exterior doors- -all will have a closer, weather - stripping and'/" thresholds, and with the following hardware: a. The main entry/exit door at the west elevation will have a pull bar on the outside, a push plate on the inside, a keyed deadbolt, and a sign on the egress side stating: This Door to Remain Unlocked When Building is Occupied ". b. The employee entrance /exit at the north elevation will have a lever handle on the outside, a panic device on the inside ( "dogged" unlocked during business hours). c. The emergency exit only on the south elevation will have no hardware on the outside, and a panic device on the inside. d. The employee entrance /exit from the 2nd floor will have a lever handle on the outside, a panic device on the inside, ( "dogged" unlocked during business hours). 3 The exterior stairway will be provided with closed, sloping risers and the nosing will be fabricated in conformance with Section 1109.8.3. This detail will be included in the deferred submittal for this stair. The interior stair has an open side between the 2 " floor Waiting room and the upper flight of the stair. This will be a solid wall, 42" high. 4. A cut sheet for the two - piece masonry veneer anchor is attached. 5. The total occupant loads are as follows: 1' Floor 54; 2 Floor = 53. 6. The accessible portion of the customer service counters at the Lobby, Office - CI, Office -CO, and the sink countertops at the Lounge rooms on the 1 and 2nd floor will be a minimum 36" wide and 34" maximum above finished floor. 7. Site Plan revisions will be submitted by the Owner or his representative. 8. 1 have discussed unresolved planning and engineering department issues with Al Shields, and all appear to be site - related. The Site Plan drawing is by others and is not included in our scope of work for the Owner. I will alert the Owner that there are site issues needing resolution. With regard to lighting, i NiIF reiterate that the lighting and electrical work will be a deferred submittal. I will " notify the Owner that the electrical subcontractor's submittal should include smvenG,antemtan, all exterior and interior lighting, egress lighting, compliance forms, and Don I3re ee. AIA exterior fixtures that meet City of Tigard standards. Mid.r1 Madre C.57 07101/2009 18:37 503 - 224 -5936 DTL ARCHITECTS PAGE 04 Checksheet Response July 2, 2009 Page 2 9. See response to item f#8. 10. The special inspections required for this project are listed on Sheet 51,1. 11. See Site Plan. The Owner will be notified that all work must conform to the Oregon Structural Specialty Code and relevant local regulations. Sincerely, Michael Madias, CSI, CCS DiBenedetto/Thomson /Livingstone Architects, P.C. Cc: John Skourtes 07/01/2009 18:37 503 -224 -5936 DTL ARCHITECTS PAGE 05 DAN -101S® Seismiclip® Interlock System Page 1 of 1 About us Products By Category By Application by Trademark Green Contact Us HISTORY -0 � HOHMANN & BARNARD, INC. ~ : ' ' :�= - , Anniversary �� I SPEC 0 ^MAI�W ." c $33 Product 1� 20 Ta -spree listing next* (-1 ftl D% I I I 1 < DW -10HS® Seismicli ® Xnterlock System " `. DIGITAL CATALO w�(" I ,,, DESCRIPTION: ti , , ''i"ri,i' • , I Use the DW -10145 to anchor brick veneer to metal stud, masonry, concrete or wood backup. (We carry a wide variety of a ' 9 " ipr screws for various types of backups.) a 13W-10115 � ` ° b • w I , ,' The W -10115 is primarily for use when there Is no Insulation •"': 2 and little potential for wallboard deterioration. For Insulated .'_�� • • , A,x, 1y' ' walls, Or when there 10 Concern about eventual wallboard \'434.>%. 'F1'• • ; :k1 I y n , I;:y t deterioration, please see our X SEAL Anchor. r ,�' °. � � • ;•' Y. e • Selsmidlp interlock 5 ,r. `' “ ,/ " ` 1 ` — i.` System: Horizontal Joint rnlnfordng wire .. ^ and 0yna -Tie are ;.napped Into Seismiellp end Covered with / 1 , mortar. This allows were, be and anchor to function as a single unit attached to the backup. Continuous wire Is bcncfidal for . PROJECT $HO ._. seismic zones or to provide additional protection against Iarpdr Image problems arising from thermal expansion end contraction. The , • continuous wire also allows for a more uniform distribution of .: lateral feretS. .., I a All anchors furnished with P/32' die. hole.: , `' GAUGES: S IB 1;p i i ■ 14 ga. or 12 pa. thick ... F ,r a Continuou$ wire for Sclsmidlp evallablo In 9 gauge or 3/16" -:. .... ,, diameter . y AVAILABLE PINISHES: • Hot Dip Galvanized or Type 304 Stainless Steel larger imago DIMENSIONS! ' ■ OW..1QHS has over 3" of vertical adtustabliity • Copyright fp 2009 Hoffmann a Barnard, Inc 30 Bosons Court :: Hauppauge, NY 11708 -0270 Talephann• (631) A34.0600 :: FAX: (631) 234.0683 :: Contact US Privacy Pollcy/TermS or 1,15a http : / /www.h- b.com/index.php? main_ page -- product info &products _ id =125 7/1/2009 IIIP DiBenedetto June 16, 2009 Thomson Livingstone Dan Nelson Architects Senior Plans Examiner 0106 SW Gibbs City of Tigard Portland, OR 97239 (503) 224 -6767 Re: Proposed Office Building at 7105 SW Gonzaga St., Tigard, Oregon Fax(503) 224-5936 Permit No. BUP2009 -00077 Checksheet Response 1. The roof trusses are a deferred submittal by the truss manufacturer. Truss details will be submitted when the manufacturer has completed their design. 2. The windows for this project are non - operable, therefore no hardware required. Window sizes are noted on the Drawings. Notes regarding doors and hardware have been added to the Drawings on Sheet Al. 3. The exterior stairway is not required to be accessible, therefore open risers are allowed. Exterior stairway is a deferred submittal and a construction note on Sheet A3 has been revised. Interior stair note on Sheet Al has been revised. 4. See response from structural engineer, attached. 5. The awning is a deferred submittal and details will be submitted by the awning manufacturer. A construction note has been added to Sheet A3. 6. The mechanical, plumbing, and electrical systems for the project are delegated design (or "bidder- design ") work and the respective subcontractors will submit the required drawings and forms under separate permits. 7. The floor trusses are a deferred submittal by the manufacturer and they will submit the required drawings and details. 8. See response from structural engineer, attached. The new sheet is S1.2. 9. Roof access will be provided by an access door from the attic to the mechanical roof area. See note on Sheet A3. 10. Ceiling grid details have been added on Sheet A2. 11. Room names have been added to Sheets A2 and A3. Typical occupant loads for office and support spaces are per building code (100 sq. ft. /person). Exam rooms will typically have a patient and either a dentist or hygienist. 12. See response from structural engineer, attached. 13. Design professional for this project: Michael Madias, Registered Architect, State of Oregon. Se b A- / _ 14. A reflected ceiling plan will be included with the electrical submittal and egress lighting will be a delegated design item by the electrical subcontractor under separate permit. Egress lighting shall comply with IBC Section 1006. Egress path diagrams have been added to Sheet Al. 15. Dimensions and notes have been added to the Drawings to reflect conformance with Chapter 11. Ptincipals 16. Finish notes have been added on Sheet Al. A. P DiBcncdato, FAIA Steven G. Thomson, AlA Don Livingstone, AlA Miduel Madias, CS] w 17. The roofing material is already noted on the Drawings. Roof insulation and notes have been added to Sheet A3. Ventilation notes have been added to Sheet A3. 18. The location and extent of the project are shown on the Site Plan. Sinc ely, Michael Mad CSI, CCS DiBenedetto/Thomson /Livingstone Architects, P.C. G: \DTL Clients \Commercial \Willamette Dental \Clinics \Gonzaga St.( Tigard) \Correspondence \Checksheet Response.doc 1. June 15, 2009 Dan Nelson (Thie City of Tigard 13125 SW Hall Blvd. James G. Pierson, Inc. Tigard, Oregon 97223 �HQrNEE�� Plan Review Comments Consulting Structural Engineers 7105 SW Gonzaga 320 SW Stark, Suite 535 Application # BUP2009 -00077 Portland, OR 97204 (503) 226 -1286 =. Dear Mr. Nelson: We have received plan review comments for the design of a new 10,400 square foot office building located at 7105 SW Gonzaga. To respond to your structural correction comments, I have repeated them below in italics followed by my response. 4) Please provide details for the attachment of brick veneer showing type ofseismic clip to be used. Structural Response: Please refer to the foundation details on sheet 4.1, where this information is specified. 8) Provide shearwall schedule showing all nailing, clips, straps and all general notes. Structural Response: This was accidentally omitted from our drawings. We have created a new sheet with this information that is included in the Revision 1 set dated June 16, 2009. 12) Show construction of interior walls showing attachment to floor, ceiling, and connection of all walls to structure. Structural Response: This detail has been added to sheet 5.1 as part. of Revision 1. If you have any further questions or comments, I would be happy to discuss this project. Sincerely yours, ■ Ciera Stachowski, PE Project Engineer Consulting Structural Engineers 320 S.W. Stark, Suite 535 Portland, Oregon 97204 Tel: (503) 226 -1286 Fax: (503) 226 -3130 1 A. RECEIVED JUN 2 6 2009 RECEIVED CITY OF TIGARD BUILDING DIVISION _2 .1 C ITY OF TIGARD 11LDING DIVISION X CST 4 - , '6.4 — Fc_.AY ri 14 /e - 6 c 9C'fM' C p 'it'll IT - 414 0 b ,Yt C City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 Wednesday, August 26, 2009 y John Skourtes National Safety Co., Inc. T 1 G R D 17010 SW Weir Rd. Beaverton, OR 97007 RE: MMD2009- 00028, National Safety Office Building, Transportation Development Tax due on additional square footage. Dear John: This advises you that a Transportation Development Tax (TDT) fee of $8,962.39 has been assessed against the 744 square feet of space added to the National Safety Office Building under MMD2009- 00028. SDR2008 -00006 granted approval for construction of a combined general office and medical office building of 10,416 sq. ft. Your request for a Minor Modification of that decision changing the building size to 11,160 sq. ft. was approved 8/25/09 under MMD2009 00028. A Traffic Impact Fee (TIF) of $86,424 was assessed against the original 10,416 sq. ft. building and has since been paid by you. TDT replaced TIF effective 7/1/09 and applies to construction projects for which Land Use Approval was received on or after 7/1/09. The additional square footage for your building is therefore subject to TDT. I have attached a Notification Form outlining your options for paying that fee. Please indicate your payment preference, sign, and return the Notification Form to me. A Calculation Worksheet is also attached showing how the TDT has been calculated for the 223 sq. ft. of additional general office space and 521 additional sq. ft. of medical office space. Please let know if you have any questions. b - 'elds ermits /Projects Coordinator 503 - 718 -2426 cc: Ron Bunch, Susan Hartnett, Kim McMillan, Dick Bewersdorff, Cheryl Gaines. Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 • CITY OF TIGARD COUNTYWIDE TRANSPORTATION DEVELOPMENT TAX (TDT) NOTIFICATION OF FEE AND PAYMENT OPTIONS Please sign and return with Building Permit Application. This advises you that the TDT for this project is as shown below and out ' es the payment • .tions that maybe available to you. A copy of the fee calculation worksheet ' attached. t will increase on July 1 if payment is not received before then. This fo s t. - • - ::.• • . - a mitt - • with your application for a building permit. City of Tigard Date: Site Address: Project /4�r} �,� L qic yy Land Use Case 71.1P vo? vvc) -7 ,7 Name: e9) / GE- ZS/wt.—Di/sig.— or Permit # : 8`— DC) e Tax 5 /c� /A� 00300 TDT Amount: � i-rp ' cal � Lot # /V //9G )1155l 3 9' This constitutes my request to use the TDT payment option or combination of options I have selected below. [This selection can by changed up to the tine a buildi'g permit is issuoi] I realize that TDT charges are due and payable at the time a building permit is issued unless those charges are Deferred or are financed through Installment Payments. [Pleaseaddstss questions about TDT orDjerral or Installnvnt Payrrents to A lbert Shields, Perm Coordinator, 503- 718- 2426.] ❑ Cash, Check, or Credit Card, payment due at building permit issuance. ❑ Deferral until Occupancy, payment due before issuance of an occupancy permit. Payment of the TDT may be deferred until issuance of the occupancy permit if the TDT is greater than the amount for a single family residence, currently $0•95 In requesting this option I understand that any deferred TDT must be paid prior to issuance of a Certificate of Occupancy and that the TDT will be recalculated at the time it is actually paid based on the TDT rates prevailing at that time. I further understand that TDT rates may increase each July 1st and that such increases are not subject to appeal. ❑ dit Voucher (for develope . t required public improvements, subject to approval, comp ion, and accepta • of creditable improvements.) P._ E E: DTr redi m l e • de- m • • at e 'me TDT Pa ent is due, either at the time the buil.',> •t is issued or, if payment is deferred, prior to issuance of an occupancy permit. If you expect : c r TDT Credits be sure the improvements, any creditable payments, and your claim for Credi : re comp .- either before your building permit is to be issued or, if payment is deferred, befo : .0 request an occ i • . nc permit. No refund of TDT Payments will be made if Credits are s 'tted more than 30 days . -r issuance of the relevant building or occupancy permit. ❑ "Bancroft" or Installment Payments (separate application required.) OWNER/APPLICANT OWNER/APPLICANT DATE: DATE: I: \CURPLN\Perrnit Coordinator \TDT Fomu \TDT Payment Option Form 062209AMS City of Tigard I I I " TDT — COUNTYWIDE 'TRANSPORTATION DEVELOPMENT TAX s ° ~Y Rate Calculation Worksheet 3 .1 A i. _ a N:ti1.:W= iir: .-s'f.W'".r ':IiMY.<fan"t2e' fi' ='VTVRR `a:g3.4'. n[;- r al U ai Ns4C; .Y4RsT3tY1.l A #C WAv"'=YrMIRV Z I APPLICANT / y , / ii/DU-5 DATE '�' 6 D y MAILING ADDRESS / AV0j0 4: 5A J w eiR PREPARED BY /4 /15 CITY / ZIP / PHON exh/ere-r-OA O/ .9 o t PLANS CHECK #S a O1-- -OODO TAX MAP # �� /O/ d � 3D D Z /D/4 L O -110 L7 PROJECT TITLE t • -OeOL.S SITUS # ADDRESS a� ,,�. j � () s - g ' �D� ,. e / Ge . 0 - ~ Thic.-,--- - 'US(S USE ITE # X RATE TDT DESCRIPTION /NOTES # CODE UNITS � / - AMOUNT / .2/!2 X ff S9 9 = r Flo o 2 .5PIi deatrE X - >44/4 *& /4 y /6.f { D�xm_ �._ X = - ovn.-B dc-- t MM6 n jczoo,s-e-DoDD0 TOTAL TDT, FORMER USE(S) c PRQPOSFI S USE ITE # TDT DESCRIPTION /NOTES # CODE UNITS X RATE AMOUNT �f 7/Q " 'Z .23 x T'' // �B = � `� 4'i a1wwN41_ �2 f CN L. V icHt t., 2720 .2,1x- f /5 3,0 - ii:ing66 h „ .5-:zi HeD, awa._ x 1R /VW LRRCE� 76,v/i bl wC-- X - ()h QQ q 6 / 2_.9 6�t it ) 2 DD 9'-vvo2S. TOTAL TDT, PROPOSED USE(S) C7 / LESS TOTAL TDT, FORMER USE(S) - 4:2 TDT INCREASE /(DECREASE)�■ J z cy / (INCREASE = TDT DUE) PAYII$T'T METHOD . CASH /CHECK NOTES CREDIT BANCROFT AGREEMENT (PROMISSORY NOTE) DEFER TO OCCUPANCY I /OFS /CD /FORMS /TDT Rate Calculation Worksheet.indd (Rev. 4/22/09) j 4 .. Permit for National Safety Co. Inc. - Message (HTML) _ r t. l ssage —Au o — -� _ *M1 t i Safe Lists t Find 4 Related Reply Reply Forward Delete Move to Create Other Block Categorize Follow Mark as to All Folder- Rule Actions ° Sender - Up - Unread Select - Respond Actions €unk B mad Option ry Fuld From: Leonard A. Rydell, PE, PLS, WRE jlarydell teleport,com] Sent: Thu 8/13/2009 11:39 AM To: Ron Bunch; 'skourtesgaol.com' Cc tim.ramisgjordanschrader.com; Cheryl Canes; Dick Bewersdorff; Mark VanDomelen; Mike White; Kim McMillan; Dan Nelson; Albert Shields; Craig Prosser; Craig Dirksen; Nick Wilson; gretchengtodard- or.gov; Marland Henderson; Sydney Sherwood Subject: Permit for National Safety Co. Inc. Message ' +Ron Bunch.pdf l40 KB) O ATT00001.c 1223 B} Ron, I am attaching a letter in response to the below e-mail. I suggest that if the record needs to be formally corrected, that the City of Tigard, at its own expense, create a new application using the correct information submitted to conform to the original application submitted by Mr. Skourtes. In the meantime, I recommend that you allow construction of the project while dry weather is still upon us so at to not create a financial hardship to Mr. Skourtes_ I look forward to receiving your confirmation that the City will promptly resolve the situation. Thanks_ I Leonard At 11 :25 AM 8112`2OO9 Ron Bunch \\ Good Morning: Zv intent was to prepare a letter, but time does not allow it. I will have this drafted in a letter format and sent to you both I cannot grant your request to make a decision to direct the PFI be done for this project in its current state_ Such a decision would be contrary to the City's Community Development Code_ No staff member can unilaterally take such an action. start DanN on 'Tiguser \U_e .. Inbo>. - O Permit _.: err . 1 Microsoft . Out , , Prrr� iit for National Sa. . r _ __ = � � 1; _? PM Dan Nelson From: Ron Bunch Sent: Wednesday, August 12, 2009 11:25 AM To: 'skourtes @aol.com'; larydell @teleport.com Cc: tim.ramis @jordanschr ader.com; Cheryl Caines; Dick Bewersdorff; Mark VanDomelen; Mike White; Kim McMillan; Dan Nelson; Albert Shields; Craig Prosser Subject: RE: subject: permit for National Safety Co. Inc. Good Morning: My intent was to prepare a letter, but time does not allow it. I will have this drafted in a letter format and sent to you both I cannot grant your request to make a decision to direct the PFI be done for this project in its current state. Such a decision would be contrary to the City's Community Development Code. No staff member can unilaterally take such an action. The issue with the building size and setbacks is straightforward. The solution, as stated in the prior correspondence requires compliance with the Development Code, which means a complete application must be submitted to modify the prior land use approval. I discussed this matter again with Cheryl Caines, Associate Planner. Her letter dated December 23, 2008 states that the applicant must submit revised materials if the building size is to be increased. These materials include plans, narrative, and all supporting documents. You state that revised plans were submitted on December 26, 2008. The plans we have in the original submittal package show 10,416 square 1 feet. A letter was not provided, stating the building size was being increased or instructing the City replace the original plans with revised ones. The supporting documents also were not revised. These include: • the City of Tigard application form that reads — net square footage under 5,000 square feet per floor • Clean Water Services Sensitive Area Pre- screening form that reads 5,000 square foot per floor office building • Traffic Report based on 10,000 square feet Notices of land use application and decision, both referencing the 10,416 square foot building were mailed to Mr. Skourtes on January 15, and February 24, 2009 respectively. No comments or questions regarding the building size or its setbacks were raised at that time. We want to help you, but we cannot do so in circumstances which require staff to ignore the City's land use laws. In conclusion for this project to proceed, an application and approval of modification to prior approval is required. Our recommendation is to set up a pre - application conference, prepare the necessary application and supporting documentation and submit an application Otherwise, please let us know If you have any further evidence that all the required materials for a modification to prior approval was submitted. Also if you have any other information let us know. Please work directly with CD staff to resolve this matter. I remain a resource to consult with, but will not be directly involved. Sincerely Ron Bunch 2 • From: skourtes @aol.com [mai lto: skou rtes @aol.com ] Sent: Monday, August 10, 2009 11:18 AM To: Ron Bunch Cc: Iarydell @teleport.com Subject: subject: permit for National Safety Co. Inc. By now you have received my E amil and my Engineers E mail. Apparently the process fell through at your end.. I am certain Cheryl Caines will not make a decision Therefore I ask you to make the call so we can get something started before the rains hit. This late in the season every week counts My phone number is 503 -841 -2410 3 City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 1 I August 7, 2009 T I G A R D Mr. John Skourtes 17010 SW Weir Road Beaverton, OR 97007 Mr. Leonard Rydell 601 Pinehurst Drive Newberg, OR 97132 -1625 Gentlemen: The City cannot do the PFI review for the plans submitted by Mr. Rydell on July 29, 2009, for the SDR2009 -00006 project, because they are inconsistent with prior planning approval as documented by Attachment 1. In order for the City to provide the necessary review, revised plans must be submitted consistent with land use approval, or the applicant must submit and receive land use approval for a modification to a prior approved application. We wish to emphasize that City staff has attempted to communicate that building plans cannot be approved that do not match land use approval. In summary: • Land use approval was granted for SDR 2009 -00006 on 2/24/09 for development of a two -story 84'x62' 10,416 square foot office and dental building with east side yard setback of 17.68 feet. • Subsequently, at different times, plans were submitted that showed a larger building of 11,160 square feet with an east side yard setback ranging between 11.69 and 12.18 feet. • City staff returned these plans with "red line" corrections noting that neither the larger building, nor the changed setback, has been approved. • The City has consistently stated both verbally, and in a letter dated December 3, 2008, that it cannot grant flexibility to increase the building size. This, in response to the owner's request to do so. Please see Attachments 2 and 3. The City has made no statements to the applicant or his consultants contrary to this position. I: \CURPL.N \ Dick \Skourtes -R,ddl letter rc SDR2009 00006.docc 1 Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard-or.gov • TTY Relay: 503.684.2772 In conclusion, in order for the City to continue its permit review of the project, the applicant must proceed as indicated above. Associate Planner, Cheryl Caines, can provide you with the appropriate application depending on which plan you choose. Sincerely, Richard Bewersdorff, Planning Manager City of Tigard Attachments: 1. Evolution of Skourte's Plans, Nat'l Safety Office Building 2. John Skourte's letter dated 11/19/08 3. Cheryl Caine's letter dated 12/3/08 cc: Ron Bunch, Community Development Director Kim McMillan, Engineering Manager Mark VanDomelen, Interim Building Official Cheryl Caines, Associate Planner Mike White, Sr. Engineering Technician Dan Nelson, Sr. Plans Examiner Albert Shields, Permit Coordinator Jennifer De Gregorio, Jordon Schrader 1: \CURPLN \Dick \Skourtes -Ryddl letter rc SDR2009- 00000.docx 2 Evolution of Skourtes Plans, National Safety Office Building Plan /Doc /rev. Received Plan Plan Building Square East Status/ Date Date From Type Dimensions Footage Setback Comment 9/5/2008 9/5/2008 Skourtes Application <5000 /floor < 10,000 Initial Applik 10/30/2008 10/31/2008 Rydell Engr. Review 84x62 10,416 Basis for Lai 10/30/2008 10/31/2008 Rydell PFI 84x62 10,416 17.68 Basis for Lai 12/11/2008 DiBenedetto Elevations 90x62 11,160 1/9/2009 DiBenedettoElevations 90x62 11,160 2/24/2009 2/24/2009 COT Approval 84x62 10,416 17.68 Land Use Ai 4/23/2009 5/11/2009 DiBenedetto Elev /Section 90x62 11,160 Redlined: "5 approved al undated 6/2/2009 Arborist Arborist 10,416 6/24/2009 6/25/2009 Arborist Arborist 10,416 7/2/2009 7/13/2009 Rydell PFI 90x62 11,160 11.68 Returned 7/ that 5208/fl 7/10/2009 7/13/2009 Rydell Site 90x62 11,160 11.59 Returned 7) that 5208/fl 7/29/2009 8/3/2009 Rydell PFI 90x62 11,160 12.18 7/29/2009 8/3/2009 Rydell Site 90x62 11,160 12.18 ATTACHMENT 2 FIV NOV 1 cl 2008 November 19, 2008 . Ji ci`�i-1; Cheryl Caines ? 11\:G °- , ; `; J � ::; � Sr;ln � y: � ;I1\; City of Tigard 13125 S W Hall Blvd. Tigard, Or. 97223 Subject: Proposed Development Lot 9 and 10 Beveland No. 2, Size 30,905 Sq. Ft. Dear Ms. Caines: Currently National Safety Co. Inc. has submittals for your approval on the above project. This is to officially notify you that we want the FLEXIBILITY to increase the foot print of structure from 62 x 84 to 62 x 90. Out side foot print would be 5,580.sq. ft. The 6 foot increase would occur on the east side of lot wherein proposed structure is 17.68 feet from property line it would thereafter be 11.68 feet. Therefore the plans as submitted would not be affected because the location of the increase was UNDEVELOPED. New inside total square footage would be 10,544, two stories. All of the criteria would still be met. Utilization of lot versus building size; In this zone no more than 85 percent of surface can be impervious. This adds .012% and does not affect the ratio because it is still around 79 to 21. Parking of 46 spaces exceeds minimum. Because of economic conditions and very high front end costs including adding fire sprinkler to the building; we need this flexibility wherein after planning has approved this project and we might decide to add the six feet when building plans are submitted planning will not have to be involved. The street view of the building has submitted shows a building 90 feet long. Si r: Natiojal a ety Co. Inc. 17010 S W Weir Rd. Beaverton, Or. 97007 John Skourtes, Applicant PH: 503- 841 -2410 City of Tigard, Oregon 13125 SW Hall Blvd. 0 Tigara, JR 97223 ATTACHMENT 3 • t } 1 rt I Sr"� A le jfyti ,} T l n( } jV December 3, 2008 John Skourtes National Safety Co., Inc. 17010 SW Weir Rd. Beaverton, OR 97007 RE: Completeness National Safety Co. Office Building Case File No. SDR2008 -00006 Dear Mr. Skouxtes: The City has received your application for Site Development Review (SDR2008- 00006) to construct a new 15,000 square foot office /retail project. The development site is located on SW 72nd Avenue between Clinton and Dartmouth Streets. Staff has completed a preliminary review of the submittal materials and has determined that the following additional information is necessary before the application can be deemed complete: 1. Narrative. Please revise the narrative to address the following code section. Provide facts within the narrative that show how the standards are met. If there is not sufficient evidence to make positive findings, Staff may not be able to approve the application. The easiest way to ensure all standards are met is to show the applicable code and then provide a response after each standard. ♦ 18.620.020, 030 and 040 — Tigard Triangle Design Standards. Please provide facts as to how each of the criteria is met. Show calculations for all percentages. 2. Plans. Elevation plans (24" x 36 ") are required in addition to the narrative to show how the Tigard Triangle Design Standards are met. Plans provided on November 19, 2008 are 11" x 17" and do not show how all the standards are met, specifically Building Design Standards (18.620.040) #2 & #4. 3. The submittal package received November 19, 2008 included a letter requesting the flexibility to increase the size of the building. Staff cannot grant a flexibility, only a specific plan. If you would like to increase the size of the building, then please revise all submittal items to reflect this change (plans, narrative, supporting documents). Otherwise staff can only approve the currently proposed plan. Once a plan is approved, you will need to apply for either a minor or major modification to the approved plan. This will be a type 1 or type 2 process depending on the changes proposed. Phone: 503.639.4171 • Fax: 503.684.7297 • . www.tigard or.gov • TTY Relay: 503.684.2772 4. Public Facility Plan Checklist: These are no longer completeness items, but please be aware of the notes in red. Should you have any questions with regard to these items, please contact me at 503 -639- 2437. Sincerely, Cheryl Gaines Associate Planner c: SDR2008 -00006 Land Use File Leonard Rydell, Consulting Civil Engineer and Land Surveyor LEONARD A. RYDELL, P.E., P.L.S., W.R.E. Consulting Civil Engineer - Land Surveyor 601 PINEHURST DRIVE, NEWBERG, OREGON 97132 -1625 (503) 538 -5700 FAX 538 -9167 ,aryd NEER tNG ell @tele port.com 29 July 2009 E IJ L I VE r City of Tigard A�'a 3 2'09 13125 S. W. Hall Blvd. Tigard, Oregon 97223 VN,N � Attn: Albert Shields, Permit Coordinator Re: Gonzaga and National Safety Improvement Plans Dear Albert, Mike White, by his letter dated 21 July 2009, mailed the construction plan redline comments for the Public and Private Improvement Plans for S. W. Gonzaga Street and the Skourtes Dental and Office Building. Enclosed, for your information and review, please find three sets of the revised plans. Please note that there are two sets of plans, one is the "S. W. Gonzaga Street Public Improvements" to be constructed under a Public Works Permit, and the second is the "National Safety Company Dental and Office Building" for the site improvements. Comments regarding Mike White's letter numbered comments are as follows: 1. The building dimensions were not changed. Mr. Skourtes has assured me that planning has approved the change. Setbacks at the Northeast and Southeast corners have been shown. Please note that the building is parallel to Gonzaga Street and not the East line. 2. The storm line has been revised as requested to provide a straight grade between the catch basins at the East and West property corners. 3. A fire hydrant has been added and the location of the FDC shown. 4. A lighting plan is being prepared by Northstar Electrical Contractors. I anticipate that it will take a week to complete. It will be submitted as a separate sheet. 5. The two pages from the Private Plans showing the water quality swale have also been included with the Public Plans, and all sheets renumbered. 6. A revised cost estimate is attached. The redline plans are attached. Mike White 28 July 2009 Page 2 of 2 Should you have any additional questions regarding the plan submission, please let both John and I know by phone or e -mail. Thank you. Sincerely yours, Leonard A. Rydell, P.E., P.L.S., W.R.E. LAR /lar end: as stated cc: John Skourtes f , LEONARD A. RYDELL, P.E., P.L.S., W.R.E. Consulting Civil Engineer - Land Surveyor Y r 601 PINEHURST DRIVE, NEWBERG, OREGON 97132 -1625 (503) 538 -5700 FAX 538 -9167 ENGINEER'S ESTIMATE larydell@teleport.com S. W. GONZAGA STREET PUBLIC IMPROVEMENTS The unit prices hereinafter written are submitted with the clear understanding that the actual measured quantities may vary somewhat from from the estimate and that payment will be based on the unit price of each item. No. Item Quantity Unit Price Total S. W. GONZAGA STREET IMPROVEMENTS 1. Excavation 177 cu.yd $ 6.00 $ 1,062.00 2. Saw Cut 302 feet $ 0.50 $ 151.00 3. Remove Catch Basin 1 each $ 200.00 $ 200.00 4. 10" C -900 PVC w /Rock BF 153 feet $ 35.00 $ 5,355.00 5. Relay 10" C -900 PVC 65 feet $ 15.00 $ 975.00 6. 12" C -900 PVC w /Rock BF 43 feet $ 40.00 $ 1,720.00 7. Oversize Catch Basin 1 each $ 1000.00 $ 1,000.00 8. Curb and Gutter 219 feet $ 17.50 $ 3,832.50 9. 15" Rock 336 sq. yd. $ 8.00 $ 2,688.00 10. 2" Class "B" Asphalt 289 sq. yd. $ 6.90 $ 1,994.10 11. 2" Class "C" Asphalt 289 sq. yd. $ 6.90 $ 1,994.10 12. Ditch /Catch Basin Protectior 1 each $ 50.00 $ 50.00 13. Sidewalk 1,536 sq. ft. $ 2.20 $ 3,379.20 14. Commercial Driveway 312 sq. ft. $ 2.50 $ 780.00 15. Street Light 1 each $ 1150.00 $ 1,150.00 16. Street Trees 7 each $ 35.00 $ 245.00 Sub Total - Gonzaga Street Improvements $ 26,575.90 PLANNED DEVELOPMENTS • RESIDENTIAL SUBDIVISIONS WATER, SANITARY SEWER AND STORM DRAINAGE SYSTEMS LAND SURVEYS • WATER RIGHTS ENGINEER'S ESTIMATE Page 2 of 2 S. W. GONZAGA STREET IMPROVEMENTS 29 July 2009 No. Item Quantity Unit Price Total WATER QUALITY SWALE IMPROVEMENTS 17. Excavation 1 each $ 800.00 $ 800.00 18. Ditch Inlet w /Orfice 1 each $ 1350.00 $ 1,350.00 19. Overflow Ditch Inlet 1 each $ 1050.00 $ 1,050.00 20. Water Quality Manhole 1 each $ 6300.00 $ 6,300.00 21. 12" C -900 PVC 26 feet $ 32.00 $ 832.00 22. Landscaping and Rock 1 each $ 2500.00 $ 2,500.00 Sub Total - Water Quality Swale Improvements $ 12,832.00 Project Total $ 39,407.90 v PROfic, :` 8,51P ,, R �I) <0 UST 22,��� '�RD A. R n''NEWAL DATE 12/31/201(0 FW: Foundation Bearing Pressures Page 1 of 1 From: Peder Golberg <peder @jgpierson.com> REC EIVED To: skourtes @aol.com • Y Subject: FW: Foundation Bearing Pressures CIT'y Date: Wed, Aug 5, 2009 9:11 am BUIL TI G ARD DIN DIVISION John, You asked about the soil information used for the two story office building on Gonzaga. As shown on S1.1 and S2.1, we used an allowable load bearing value of the soil of 1500 psf. This is the presumptive load- bearing value allowed per the code (Table 1804.2 in the IBC). The Presumptive values can only be used when the footings are not placed on fill. The 2 story wood office building does not fall under the mandatory foundation and soils investigation requirements (Section 1802) due to its size and building type. There is a footnote, however, in Table 1804.2 that gives the building official authority to require a soils investigation if they feel the site has bearing capacity of less than 1500 psf. One option for the soils report is to look at neighboring construction and their reports. Hope this helps. Peder Goiberg, P.E. /S.E. Principal James G. Pierson. Inc. Consulting Structural Engineers 320 SW Stark #535 Portland, Oregon 97204 503 -226 -1286 www.jgpierson.cor • http: / /webmail.aol.com/ 43792 /aol /en -us /mail/PrintMessage.aspx 9/5/2009