COVER LETTER:
RECEIV
Api. 2006
April 25, 2006
CITY OF TIGAAD
Val Henze! BtJI�DING DIVISION
Senior Plans Examiner
City of Tigard
13125 SW Hall Blvd
Tigard, OR 97223
RE: Tigard First Baptist Church Site Permit Application SIT2006 -00002
Val:
Per your request, I am submitting another set of updated plans for the Tigard First Baptist Church project.
I you have any questions, please don't hesitate to contact us
Thank you,
Karina Adams
MS Architecture
Attachments:
Revised Architectural Drawings A0.1 and A1.1 Dated April 18, 2006
Revised Civil Drawings C -1 through C -14 Dated April 13, 2006
May 4, 2006 Diivriv��ip "W��Ib��`
CITY OF TIGARD
MS Architecture OREGON
Mark Sienieniec
1001 SE Water Ave.
Portland, OR 97214
RE: 1 BAPTIST CHURCH — PARKING LOT /RETAINING WALLS (1 PHASE ONLY)
Project Information
Site Permit SIT2006 -00002 Construction Type: U
Tenant Name: 1" Baptist Church
Address: 11075 SW Gaarde St
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004
edition; and the Tualatin Valley Fire & Rescue Fire & Life Safety Requirements for Fire Department
Access and Water Supplies (Based on the 2004 Oregon Fire Code as amended by TVF&R). The
submitted plans are approved subject to the following.
EROSION
1. Erosion control measures shall be in place prior to excavation or grading.
RETAINING WALLS
2. Retaining Walls shall be installed per engineer design and manufactures specifications.
3. Special inspection is required for engineered grading, excavation and fill. The special
inspection agency shall furnish inspection reports to the Engineer of Record, the General
contractor, and the City of Tigard Building Division (atm. Hap Watkins). All discrepancies
shall be brought to the attention of the general contractor for correction. The special
inspector shall submit a final signed report stating whether the work requiring special
inspection was, to the best of the inspector's knowledge, is in conformance with the
approved plans and specifications and the applicable workmanship provisions of the code
1701.3 OSSC
4. The City of Tigard, Building Division, is requiring Structural Observations per section
1709 Oregon Structural Specialty Code (OSSC). The owner shall employ a registered design
professional to perform structural observations as defined in Section 1702, OSSC. The
structural observations shall take place during the placement of retaining walls.
Deficiencies shall be reported in writing to the owner and to the City of Tigard, Building
Division, attention Hap Watkins.
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
FIRE DEPARTMENT ACCESS
5. The driveway is considered a fire department access roadway. The driveway shall be capable
of supporting a 12,500 pound wheel point load and a gross vehicle weight of 50,000 pounds.
ACCESSIBILITY
6. Accessible walkways and routes shall not exceed a running slope of 1 unit vertical in 20 units
horizontal (5% slope). Cross slopes shall not exceed 1 unit vertical in 50 units horizontal (2%
slope).
7. Accessible parking spaces and access aisles shall be located on a surface with a slope not to
exceed 1 unit vertical in 50 units horizontal in all directions. 1104.4.3 OSSC
8. The accessible parking sign is required to be 84 inches to the bottom of the sign.
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be
maintained on the jobsite. The plans shall be available to the Building Division inspectors
throughout all phases of construction. 106.4.2 OSSC
Premises Identification: Approved numbers or addresses shall be provided for all new buildings in
such a position as to be plainly visible and legible from the street or road fronting the property.
When submitting revised drawings or additional information, please attach a copy of the enclosed
City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in
tracking and processing the documents.
Respectfully,
Val Henzel,
Senior Plans Examiner
CES NW
FILE COPY
April 4, 2007
Mr. Hap Watkins, Inspection Supervisor �' 07
City of Tigard 5
13125 SW Hall Blvd.
Tigard, OR 97223
RE: TIGARD FIRST BAPTIST — WATER QUALITY SWALE
Dear Mr. Watkins:
Based on the survey data we received and our onsite inspection of the Tigard First Baptist water
quality swale, we believe it was constructed in accordance with the design and approved
construction drawings.
Let me know if you need anything else in this regard.
Sincerely,
CESNW, Inc.
O r, Rt l•l ir i i
Anthony • R. eller, P.E., P.L.S. 4;z/ , A
President
ow : Lr
• i �"'
Cc: Jim Wilson, Tigard First Baptist ,��, r •
Mark Siemieniec, MS Architecture `/O
R.
►`��^?w1 S _ <0 3
1845b \wp \040407 -watki ns.doc
CESNW,INC.
15573 SW BANGY RD., STE. 300 LAKE OSWEGO, OR 97035
503.968.6655 TEL 503.968.2595 FAX www.ccsnw.com
March 2, 2006
CITY OF TIGARD
MS Architecture
Mark Sienieniec OREGON
1001 SE Water Ave.
Portland, OR 97214
RE: 1 51. BAPTIST CHURCH — PARKING LOT /RETAINING WALLS (1' PHASE ONLY)
Project Information
Site Permit: SIT2006 -00002 Construction Type: U
Tenant Name: 1°` Baptist Church
Address: 11075 SW Gaarde St
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004
edition; and the Tualatin Valley Fire & Rescue Fire & Life Safety Requirements for Fire Department
Access and Water Supplies (Based on the 2004 Oregon Fire Code). The following information is
required in order to complete the review.
GENERAL
1. Provide geotechnical report as required per OSSC chapter 18.
2. FYI; Sheet C -9 shows Sprinkler Vault located by FDC on private property check with TWD for
location requirements on private property.
RETAINING WALLS
1. Provide location, design and construction of all retaining walls on site. OSSC 1806
FYI; Note: Geogrid type retaining mat will not be permitted to cross the property line.
2. Drainage for retaining walls shall be shown on the plans including the connection to an
approved point of discharge. Indicate piping slope, size, material and backwater valves if
required by code. OSSC Chapter 18
FIRE REVIEW
3. Underground Fire Fighting Water Supply. Provide thrust blocking details including cut
sheets and installation instructions for any mechanical joint connections. Provide supply pipe
burial depth, piping sizes and materials, valve equipment cut sheets, vault details, equipment in
vaults, details for hydrants and Fire Department Connection (FDC) location that are necessary
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
for the installation of the fire service. All valves shall be listed for use in a fire service application.
NFPA 24 OFC 508
NFPA 24 section 4.1.3 for the items necessary for a plan review.
4.1.3 (13:8- 1.1.1) Working plans shall be drawn to an indicated scale on sheets of uniform size, with
a plan of each floor, and shall include the following items that pertain to the design of the system:
(1) [24:1- 4.2(a)] The size and location of all water supplies
(2) [13:8 - 1.1.1(27)] The size and location of standpipe risers, hose outlets, hand hose, monitor
nozzles,
and related equipment
(3) [13:8 - 1.1.1(28)] The following items that pertain to private fire service mains:
a. Size
b. Length
c. Location
d. Weight
e. Material
f. Point of connection to city main
g. Sizes, types, and locations of valves, valve indicators, regulators, meters, and valve pits
h. Depth at which the top of the pipe is laid below grade
(4) [13:8 - 1.1.1(43)] The following items that pertain to hydrants:
a. Size and location, including size and number of outlets and whether outlets are to be equipped
with independent gate valves.
b. Whether hose houses and equipment are to be provided, and by whom
c. Static and residual hydrants used in flow
(5) [13:8- 1.1.1(44)] Size, location, and piping arrangement of fire department connections
ACCESSIBILITY
4. Accessible parking sign shown in detail sheet A0.1 (6) is required to be 84 inches to the bottom
of the sign. Revise the detail.
When submitting revised drawings or additional information, please attach a copy of the enclosed
City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in
tracking and processing the documents.
Respectfull
/
Val Henze
Senior Plans Examiner
/�.y y. ■ 1001 SE Water Ave. #200
Siemieniec Ar ch„ectum Phone Portland, Oregon 97214
503.245.4163
, Mark Fax 503.231.5319
i '
K T
COVER LETTER. ci 10 Ce
April 19, 2006 QQ\ F 1� --d��
Val Henzel 1 `� o '.
Senior Plans Examiner C
City of Tigard .C,f
13125 SW Hall Blvd
Tigard, OR 97223
RE: Tigard First Baptist Church Site Permit Application SIT2006 -00002
Val:
Per the attached Plans Review Letter of Transmittal, we are supplying you with the updated drawings that reflect
the information you request in the letter. We are also supplying you with the most current geotechnical report as
you requested.
I you have any question, please don't hesitate to contact us
Thank yo
i:M..-Cic.
Karina Adams
MS Architecture
Attachments:
Plans Review Letter of Transmittal Dated March 2, 2006
Carlson Geotechnical Letter Dated April 17, 2006 (1 page)
Carlson Geotechnical Additional Geotechnical Recommendations Dated April 11, 2006 (11 pages)
Revised Architectural Drawings A0.1 and A1.1 Dated April 18, 2006
Revised Civil Drawings C-1 through C-14 Dated April 13, 2006
Carlson Geotechnical Report Dated February 16, 2005
March 2, 2006
April 26, 2006
MS Architecture
Mark Sienieniec
1001 SE Water Ave.
Portland, OR 97214
RE: 1 BAPTIST CHURCH — PARKING LOT /RETAINING WALLS (1 PHASE ONLY)
Project Information
Site Permit: SIT2006 -00002 Construction Type: U
Tenant Name: 1 Baptist Church
Address: 11075 SW Gaarde St
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004
edition; and the Tualatin Valley Fire & Rescue Fire & Life Safety Requirements for Fire Department
Access and Water Supplies (Based on the 2004 Oregon Fire Code). The following information is
required in order to complete the review.
GENERAL — Reviewed 3/2/06
1 copy
1. Provide geotechnical report as required per OSSC chapter 18. RECEIVED 4/21/06
2. FYI; Sheet C -9 shows Sprinkler Vault located by FDC on private property check with TWD for
location requirements on private property. ** *3/13/06 conversation w /carl he states part of
city easement plan
':**"NEED COPY OF EASEMENT
INFORMATION"
RETAINING WALLS
Need location of retaining walls & # 2 information
1. Provide location, design and construction of all retaining walls on site. OSSC 1806
FYI; Note: Geogrid type retaining mat will not be permitted to cross the property line.
2. Drainage for retaining walls shall be shown on the plans including the connection to an
approved point of discharge. Indicate piping slope, size, material and backwater valves if
required by code. OSSC Chapter 18
FIRE REVIEW ***3 /13/06 conversation w /carl information on plans sheet 1 & 14
I see information on sheet C -14 I do not have sheet C -1 *please provide
3. Underground Fire Fighting Water Supply. Provide thrust blocking details including cut
sheets and installation instructions for any mechanical joint connections. Provide supply pipe
burial depth, piping sizes and materials, valve equipment cut sheets, vault details, equipment in
vaults, details for hydrants and Fire Department Connection (FDC) location that are necessary
for the installation of the fire service. All valves shall be listed for use in a fire service application.
NFPA 24 OFC 508
NFPA 24 section 4.1.3 for the items necessary for a plan review.
4.1.3 (13:8- 1.1.1) Working plans shall be drawn to an indicated scale on sheets of uniform size, with
a plan of each floor, and shall include the following items that pertain to the design of the system:
(1) [24:1- 4.2(a)] The size and location of all water supplies
(2) [13:8 - 1.1.1(27)] The size and location of standpipe risers, hose outlets, hand hose, monitor
nozzles,
and related equipment
(3) [13:8 - 1.1.1(28)] The following items that pertain to private fire service mains:
a. Size
b. Length
c. Location
d. Weight
e. Material
f. Point of connection to city main
g. Sizes, types, and locations of valves, valve indicators, regulators, meters, and valve pits
h. Depth at which the top of the pipe is laid below grade
(4) [13:8 - 1.1.1(43)] The following items that pertain to hydrants:
a. Size and location, including size and number of outlets and whether outlets are to be equipped
with independent gate valves.
b. Whether hose houses and equipment are to be provided, and by whom
c. Static and residual hydrants used in flow
(5) [13:8- 1.1.1(44)] Size, location, and piping arrangement of fire department connections
ACCESSIBILITY 1 copy
RECEIVED 4/21/06
4. Accessible parking sign shown in detail sheet A0.1 (6) is required to be 84 inches to the bottom
of the sign. Revise the detail.
When submitting revised drawings or additional information, please attach a copy of the enclosed
City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in
tracking and processing the documents.
Respectfully,
Val Henzel,
Senior Plans Examiner