Loading...
Plans 0 /a/ 3-6 d P1-83 Greenheck 11/28/06 JOB: CRL -AAA _ Fan MARK: EF GB 35.5 Belt Drive Centrifugal Roof Exhaust Fan Tag: EF STANDARD CONSTRUCTION FEATURES T F-r-P-..- Aluminum housing • Backward inclined aluminum wheel •Curb cap with prepunched mounting holes • Motor and drives isolated on shock mounts • Birdscreen • Ball bearing motors • Adjustable motor pulley • Adjustable motor plate • Fan shaft mounted in ball bearing pillow blocks • Bearings meet or exceed z8 temperature rating of fan • Static resistant belts • Corrosion resistant fasteners SELECTED OPTIONS & ACCESSORIES Switch - Nema -1, Toggle, Junction Box Mounted and Wired Curb GPI- 30-G12 Damper WD- 100 -PB- 18x18, Gravity Operated 5.5 Aluminum Rub Ring ) $ I Lifting Lugs _ I 1.75 UUcUL -705 - "Power Ventilators" 30 0-1 t • May be greater depending on motor. NOTES: All dimensions shown are in units of inches Fan weight is without accessories DIMENSIONS Approx. Fan Recommeded Roof/Wall Optional Weight (lb) Opening (in) Damper (in) 125 20.5x20.5 18x18 PERFORMANCE (Elevation ft = 0, Airstream Temperature F = 70) Motor Information Qty Model Volume SP (in 930 „,, Operating (CFM) wg) Power (hp) Size (hp) V /C /P End: Motor RPM: Windings FLA (A) 1 GB- 180-10 4,000 0.25 1,087 0.74 1 460/60/3 ODP 1725 1 2.1 SOUND FLA - Based on tables 150 or 148 of Inlet Sound Power by Octave Band National Electrical Code 2002. Lwa dBA Sones 62.5 125 250 500 1000 2000 4000 8000 LwA - A weighted sound power level, based on ANSI 81.4. 80 78 83 77 71 73 65 56 79 68 16 dBA - A weighted sound pressure level, based on 11.5 dB attenuation per octave band at 5.0 ft. Sones calculated using AMCA 301 at 5.0 ft. 1.8 0.0 amca = ttmnras 1.6 - - r ∎ ∎ ` 0.8 — SOD — , i — 5 1A -1087 RPM - o.� RIR - I - m8 • Illoyfl11EnT - 1.2 ! 0.6 nnD CORTROI — InTEROnT OMM Intl — i — _ • _ to 0.5 c — • — _ _ 0.4 0.8 s a° � °e • _ 0 — m 0.6 _ ... I 0 . — 0.3 S D J e A e — OA — eS, 0.2 — I. — t�C^ 0 0.2 — ` tre i — 0.1 -0 not 4044- _ 0.0 ,:_� - . . ___ �.��� _ _ - _ _ _ 0.0 0 b 10 15 20 25 30 95 40 45 Volume (CFM) x 100 CAPS 3.1.2.3 ffi Greenheck 11/28/06 JOB: CRL -AAA Fan MARK: EF G P I Roof Curb STANDARD CONSTRUCTION FEATURES • Welded Aluminum (0.064 in) or galvanized (18 ga) construction • Straight sided • 2 in roof mounting flange • 1 in 3# density insulation • Wood nailer. Roof Opening - The Maximum roof opening dimension should not be greater than the "Actual" top outside dimension minus 2 in. With dampers, the Minimum roof opening dimension should be at least 2.5 in more than the damper dimension. NOTES: * The Roof Opening Dimension may NOT be the Structural Opening Dimension. * Maximum single piece shipping length is 76 ". * Security Bars are optional and must be specified. They are 0.5 in steel, and will be placed 6 in on center. These bars are welded to the frame, and - the frame is welded to the curb. To prevent corrosion, they are coated with Greenheck's high performance Permatector coating. Security Bars are in lieu of damper and damper tray. 28.5 28.5 12 O 32.5 32.5 NOTES: All dimensions shown are in units of inches CAPS 3.1.2.3 Thy Greenheck 11/28/06 JOB: CRL -AAA • Fan MARK: EF WD-100 Horizontal Mount Exhaust Damper STANDARD CONSTRUCTION FEATURES Horizontal mount exhaust damper (air flow up) is constructed of 18 ga. galvanized steel with pre - punched mounting holes. • Damper blades are 0.025 in roll formed aluminum with vinyl seals on the closing edge, and spring assisted for ease of opening • Steel axles are 0.188 in diameter zinc plated mounted in acetal bushings • Synthetic axle bearings Accessory Configuration Blade Action Parallel Actuator Type Gravity 0 0 3' 3 Q 6.63 2.5 1 41111<.' ""...... , - -- 40 01111o. 18 \ / 18 NOTES: All dimensions shown are in units of inches Width and height furnished approximately 0.125 in undersize. CAPS 3.1 2.3 '. ar Greenheck 11/28/06 JOB: CRL -AAA • . Ventilator MARK: Intake Hood 1.5 A HGI 1-------- . Hooded Gravity Intake STANDARD CONSTRUCTION FEATURES r' Tw f z.s •Precision formed locked rib construction. • Available in aluminum or galvanized steel construction. • 0.5 in galvanized steel mesh birdscreens. • �— Curb cap wh — Heavy gauge galvanized steel support members. • Hood can be removed completely from the base or hinged open. B i • All sizes ship assembled • All sizes include tie down points • Recommended roof opening dimension is at least 2.5 in larger than the _ . _ . . 1 damper size. c I TL �� Base Height I SELECTED OPTIONS & ACCESSORIES t Galvanized Birdscreen - 0.5 in Mesh Type I cue cap Length —I Galvanized Steel Housing Curb GPI -G12 NOTE: All dimensions shown are in units of inches DIMENSIONS .. .. Opt. Throat Throat Curb Curb Opt Damper Base ID # Tag Qty W L A (in) B (in) C (in) Cap Cap Damper L wt. Height Shipped id en Width Length Width ( (lb) Assembled idth ( in) (in} en (in) (in) in) i ' ( ( r� ) n) 1 -1 1 54 54 92 108 26 58.5 58.5 54 54 304 5 Yes PERFORMANCE Volume Throat Throat ID # Tag Qty (CFM) SP (in wg) Area Velocity (ft2) (ft/mi) 1 -1 1 4,000 0.009 20.25 197.5 CAPS 3.1.2.3 Greenheck 11/28/06 JOB: CRL -AAA • • Accessory P 1 Roof Curb STANDARD CONSTRUCTION FEATURES Actua L Actual W • Welded Aluminum (0.064 in) or galvanized (18 ga) construction • Straight sided • 2 in roof mounting flange • 1 in 3# density insulation • Wood 1.75 nailer. ., Roof Opening - The Maximum roof opening dimension should not be greater than the "Actual" top outside dimension minus 2 in. With dampers, the Minimum roof opening dimension should be at least 2.5 in more than eight the damper dimension. NOTES: • ■ * The Roof Opening Dimension may NOT be the Structural Opening .<4: / Dimension. * Maximum single piece shipping length is 76 ". " Security Bars are optional and must be specified. They are 0.5 in steel, Flange , lange L and will be placed 6 in on center. These bars are welded to the frame, and `��� frame is welded to the To prevent corrosion, they are coated with h Greenhedc's high performance Permatector ctor coating. Security Bars are in lieu of damper and damper tray. NOTES: All dimensions shown are in units of inches • Cap Actual Flange Damper Tray Mark Qty. W x L W x L W x L Height W x L Intake Hood - 1 1 58.5 x 58.5 57 x 57 61 x 61 12 CAPS 3.1.2 3