Permit *), CITY OF TI LAID MECHANICAL PERMIT DEVELOPMENT SERVICES PERMIT #: MEC2004 -00150 8 "-1 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 3/25/04 PARCEL: 25101 BB -01500 SITE ADDRESS: 12254 SW GARDEN PL BLD1 SUBDIVISION: CROW PARK 217 ZONING: C -G BLOCK: LOT: 003 JURISDICTION: TIG CLASS OF WORK: ALT FLOOR FURN: EVAP COOLERS: TYPE OF USE: COM UNIT HEATERS: VENT FANS: 1 OCCUPANCY GRP: B VENTS W/O APPL: VENT SYSTEMS: STORIES: BOILERS /COMPRESSORS HOODS: FUEL TYPES 0 - 3 HP: DOMES. INCIN: 3 - 15 HP: COMML. INCIN: MAX INPUT: BTU 15 - 30 HP: REPAIR UNITS: FIRE DAMPERS ?: 30--- 50 —HP: WOODSTOVES: GAS PRESSURE: 50 + HP: CLO DRYERS: FURN < 100K BTU: AIR HANDLING UNITS OTHER UNITS: FURN > =100K BTU: <= 10000 cfm: GAS OUTLETS: > 10000 cfm: Remarks: Mechanical TI, relocate ducts & grilles, add (1) restroom vent fan. Project Value: $1,500 Owner: FEES SPIEKER PROPERTIES LP Description Date Amount 4380 SW MACADAM AVE STE 100 PORTLAND, OR 97201 [MECH] Permit Fee 3/25/04 $72.50 [TAX] 8% State Surchaq 3/25/04 $5.80 Phone: Total $78.30 Contractor: HUNTER DAVISSON INC 1800 SW PERSHING PORTLAND, OR 97202 REQUIRED INSPECTIONS Phone: 503 - 234 - 0477 Mechanical Insp Final Inspection Reg #: LIC 01612 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other pplicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -00 - � \ ��� Issued : , , C�f�OC Permit S ignature: ` � �6 Call (503) 639 -4175 by 7:00 P.M. for inspections n- • • ed the next business day Mecha anical Permit Application FOR OFFICE. USE ONLY , nical �� Received Mechanical V/ Date/By. y. ,5 Permit No G'e-OI oV-exY D City of Planning Ap.roval - Building `J Dr Tigard g DateBy Permit No 13125 SW Hall Blvd. Plan Review Other Tigard, Oregon 97223 Date /By: Permit No Phone: 503- 639 -4171 Fax: 503 -598 -1960 Post - Review Land Use rtpol ' Date/By y Case No r. Internet: www.ci.tigard.ous 1 Contact Juris . ® See Page 2 for 24 -hour Inspection Request: 503- 639 - 4175 '""''- "' "'` P q Name/Method. Supplemental Information. TYPE OF_WORK COMMERCIAL FEE *: SCHEDULE - = ,USE'CHECKLIST'- : -' ❑ New construction ❑ Demolition Mechanical permit fees* are based on the total value of the work Addition/alteration/replacement ❑ Other: performed. Indicate the value (rounded to the nearest dollar) of all ' 'CATEGORY OF CONSTRUCTION. mechanical materials, equipment, labor, overhead and profit. ❑ ' 1 & 2- Family dwelling Ettommercial/Industrial Value: $ /5 -- See Page 2 for Fee Schedule ❑ Accessory Building ❑ Multi - Family -- - RESIDENTIAL" EQUIPMENT /SYSTEMS:FEE *SCHEDULE Description - Qty - Fee(ea.)- - Total -- ❑ Master Builder ❑ Other: Heating/Cooling - " JOB SITE INFORMATION 'and LOCATION - ' " `. Furnace - add - air conditioning ** 14.00 Job site address: %ZZCy S'i„J &,O'L 6,w 6(„ Gas heat pump 14.00 Suite #: Bldg. /Apt. #: Duct work 14.00 Project Name: - 7--EL Hydronic hot water system 14.00 Residential boiler Cross street/Directions to job site: (for radiator or hydronic system) 14 00 / -1411 .58/0 ,t/65er `tv .413 C Unit heaters (fuel, not electric) (in wall, in -duct, suspended, etc.) 14.00 Flue /vent (for any of above) 10.00 Subdivision: Lot #: Repair units 12.15 Other Fuel Appliances Tax map /parcel #: Water heater 10 00 ...-. " " DESCRIPTION.OF WORK . Gas fireplace 10 00 ,/77i4 64-,/(tS Flue vent (water heater /gas fireplace) 10.00 Log lighter (gas) 10 00 Wood/Pellet stove 10 00 t/J%4 // ea , A) Wood fireplace /insert 10 00 Chimney/liner /flue /vent 10.00 `/PROPERTY_ OWNER. ° , .1:1,TENANT: --:.' r ., • : '' ,, . Other 10.00 Name: - Environmental Exhaust & Ventilation Range hood/other kitchen equipment 10.00 Address: City /State /Zip: Clothes dryer exhaust 10 00 Single duct exhaust Phone: Fax: (bathrooms, toilet compartments, f ❑APPLICANT" , ,.. CONTACT`P1 RSON 7; utility rooms) 6.80 Name: T,tl-\I 1 M Lj Attic /crawl space fans 10.00 Address: f " Other: 10.00 �qNW l .! r 7✓> 7►1Z Fuel Piping City /State /Zip: * *($5.40 for first 4, $1.00 each additional) Phone: Fax: Furnace, etc. ** E-mail: Gas heat pump ** Wall /suspended /unit heater ** ', _ , . ` CONTRACTOR; :: :. , - : ' , Water heater ** Business Name: /-] p n -7 04-vii so ,J Fireplace ** Address: jkjy) Sc lWJ/fiti,r Range ** BBQ ** City /State /Zip: f%ttj OK 2262 Clothes dryer (gas) ** Phone: 93 t/ _G I/77 Fax: ,9J6 /6-? ( Other: ** CCB Lic. #: it Total. Authorized Mechanical Permit Fees* Signature- r- / Date - Subtotal: $ Minimum Permit Fee $72.50 $ 7 ' 5-15 'q-0o )/l .(d i—ft/ Plan Review Fee (25% of Permit Fee) $ (Please pnnt name) State Surcharge (8% of Permit Fee) $ 5. 6 TOTAL PERMIT FEE $ 7c( 7 j 0 Notice: This permit application expires if a permit is not obtained within *Fee methodology set by Tri -County Building Industry Service Board. 180 days after it has been accepted as complete. * *Site plan required for exterior A/C units. I \Dsts\Pemvt Forms\MecPermitApp.doc 01/03 Mechanical Permit Application - City of Tigard Page 2 - Supplemental Information Commercial Fee Schedule: TOTAL VALUATION: PERMIT FEE: $1.00 to $2,000.00 Minimum fee $72 50 $2,001.00 to $5,000.00 $72.50 for the first $2,000.00 and $2.30 for each additional $100.00 or fraction thereof, to and including $5.000.00 $5,001.00 to $10,000.00 $141.50 for the first $5,000.00 and $1.80 for each additional $100.00 or fraction thereof, to and including $10,000.00. $1 0,001.00 to $50,000.00 $231.50 for the first $10,000.00 and $1.35 for each additional $100.00 or fraction thereof, to and including $50,000.00. $50,001.00 to $100,000.00 $771.50 for the first $50,000.00 and $1.25 for each additional $100.00 or fraction thereof, to and including $100,000.00. $100,001.00 and up $1,396.50 for the first $100,000.000 and $1.10 for each additional $100.00 or fraction thereof. All New Commercial Buildings require 2 sets of plans. • i:\Building\Permit Forms \MecPermitAppPg2 09- 01- 03.doc CITY OF TIGARD 24 -Hour BUILDING Inspection Line:.. 03) 639 -4175 INSPECTION DIVISION Business Lind: (503) 639 -4171 MST BUP Received � � / 8 Date Requested `y` 6 Z9 - AM PM BUP Location /2- 2 P/ Suite d Cin « 7 / 5-0 Contact Person ,( 4 a.0 Ph (S7) '73 2/SZ PLM Contractor Ph ( ) SWR BUILDING Tenant/Owner ELC Footing Foundation ELC Access: Ftg Drain ELR Crawl Drain Slab Inspection Notes: SIT Post & Beam Shear Anchors Ext Sheath /Shear - Int Sheath/Shear Framing Insulation Drywall Nailing Fi rewal I Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Other: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Rough -In Water Service Sanitary Sewer Rain Drains Catch Basin / Manhole Storm Drain Shower Pan Other: Final PASS PART FAIL MECHANICAL Post & Beam ough -In Gas Line - ropers 1C PART FAIL ELECTRICAL Service Rough -In UG /Slab • Low Voltage Fire Alarm Final Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd. PASS PART FAIL SITE - ❑ Please call for reinspection RE: n Unable to inspect – no access Aire Supply Line :/ / t '— ,l , ADA Approach /Sidewalk Date Inspector GI ..146r Ext Other: Final DO NOT REMOVE this inspection record from the Job site. PASS PART FAIL