Loading...
Correspondence October 5, 2005 CITY OF TIGARD Fire Protection Services Inc OREGON 18270 Sw Mountain Home Rd Sherwood, OR 97 RE: MODIFICATION - FIRE ALARM SYSTEM — SMOKE AND HEAT DETECTORS Project Information Building Permit: BUP2005 -00496 Construction Type: III -B Tenant Name: Vesta Occupancy Type: B Address: 11950 SW Garden P1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; the Oregon Fire Code 2004 edition and NFPA 72. The submitted plans are approved subject to the following. GENERAL REQUIREMENTS 1. Initiating devices shall be supported independently of their attachment to the conductor. NFPA 72, 5.4.3 2. Initiating devices shall be installed in a manner that provides accessibility for periodic maintenance. NFPA 72, 5.4.4 3. Unless tested and listed for recessed mounting, detectors shall not be recessed into the mounting surface. NFPA 72, 5.5.1 4. Wall mounted appliances shall be based on locating the visible notification appliance at the halfway distance of the wall. NFPA 72, 7.5.4.1.3 When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfull Ge/ .1 Henz , Senior Plans Examiner 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Fire Protection Services py 5573 SW Arctic Dr Beaverton, OR 97005 Phone: (503) 590-3732 DEscE Fax: (503) 628 -6214 Ves ta FIRE ALARM DESCRIPTION DESCRIPTION Smoke and Heat Detection supervision will be added to the Pre - action Fire Sprinkler System utilizing a multi -zone F.A.C.P. The interior horn/strobe will be mounted at 84" to the bottom of the device. All audible devices will sound in the ANSI temporal pattern. All strobe flashes will be synchronized where applicable. Primary power to the panel shall be 110 VAC utility power with a 24VDC 7aH battery back -up. All NAC circuits, which will be wired with 14 gauge FPLR/CMR red cable. Monitoring will be provided through Alarm Central Station, a U.L. listed monitoring company (503.641.6761) All installation will be done according to N.F.P.A. 72 standard. Work will be performed in a neat and professional manner. All work will be performed according to the timeline set. • All equipment will be UL listed and approved for the application. SYSTEM COMPONENTS Viking B -1 Fire Alarm Control Panel Gentex Commander Series Horn Strobes System Sensor 1400 Smoke Detectors Chemtronics Heat Detectors 10 SILENT VIKING B -1 Battery Calculation Worksheet KNIGHT (all currents stated in mA) 9/26/2005 Instructions: fill in shaded data fields JOB: VESTA PREACTION Quantity of Standby mA Alarm mA Total Device Total Device ADD 11950 SW GARDEN PLACE TIGARD OR Devices Per Device Per Device Standby mA Alarm mA VIKING B -1 1 120 400 120 400 4180 Status Display Module 0 20 140 0 0 5205 Dialer 0 10 100 0 0 5220 Direct Connect Module 0 50 50 0 0 5230 Remote Annunciator 0 60 120 0 0 7181 Zone Converter 0 35 65 0 0 Total SK -2224 System Current 120 400 Smoke Detectors / Auxiliary Devices SYSTEM SENSOR 1400 6 0.012 77 0.072 462 CHEMTRONICS 151 FIXED 0 0 0 List Device Here 0 0 0 List Device Here 0 0 0 List Device Here 0 0 0 List Device Here 0 0 0 List Device Here 0 0 0 Device Totals 6 0.072 462 Notification Appliances (list all) ADA strobes 0 N/A N/A 0 Bells 0 N/A N/A 0 Horns 0 N/A N/A 0 Smoke detector horns 0 N/A N/A 0 Aux relays 0 N/A N/A 0 Other 0 N/A N/A 0 Other 0 N/A N/A 0 Notification Appliance Totals 0 N/A 0 Summary Section Standby Hrs. Required 24 Alarm Sounding Minutes 5 Total System Standby mA 120.072 Total System Alarm mA 862 Total System Standby NH 2.88 Total System Alarm A/H 0.07 Min. NH Battery Required 2.95 Recommended A/H Battery ** 3.54 * If you are using door holders, you do not need to consider door holder current for alarm current or loss of AC, because power is removed during that time. However, during normal operation, door holders draw current and must be included in the total standby current that can be drawn from the panel. ** Use next size battery with capacity greater than required.