Loading...
Correspondence * - t .i,p i�` September 29, 2005 .,�.. CITY OF TIGARD OREGON Toni King and Associates Aly Pierce 330 SE MLK Blvd. #350 Portland, OR 97214 RE: DR WILLCOX - REVIEW Project Information Building Permit: BUP2005 -00453 Construction Type: 5 -B Tenant Name: Dr. Willcox Occupancy Type: B Address: 11545 SW Durham Rd. B -6 Occupant Load: 23 Area: 2,204 sq ft Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and 2004 Oregon Fire Code as amended by TVF &R. The following information is required in order to complete the review. NOT PART OF THIS REVIEW: * Electrical * Mechanical * Plumbing 1. The main exterior door or doors are permitted to be equipped with key- operated locking devices from the egress side provided: 1. The locking device is readily distinguishable as locked, 2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR 0 REMAIN UNLOCKED WHENBUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting Background. 1008.1.8.3 OSSC 2. All exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. 1008.1.8 OSSC 3. Safety glazing including but not limited to: the following locations: Each unit of glazing shall be permanently identified by the manufacturer. Sec. 2406. Some of these locations are as follows: a. Glazing in ingress and means of egress doors. b. Glazing in storm doors. c. Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical edge is within a 24" arc of the door in a closed position and whose bottom edge is less than 60" above the floor or walking surface except when there is an intervening wall or other permanent barrier between the door and the glazing. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 4. American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC, which may not include all of the requirements of the ADA. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy 110.1 OSSC Premises Identscation: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfu al Henzel Senior Plans Examiner t