Loading...
Correspondence FIE COPY . . • ,„„p„/„„,„„ May 15, 2004 ` CITY OF TIGARD OREGON W. Lane Brown Southwest Church of Christ 9725 SW Durham Road Tigard, OR 97224 RE: ADDITION OF NEW AUDITORIUM Site Permit: BUP2004 -00164 Construction Type: V - 1HR Tenant Name: SW Church of Christ Occupancy Type: A2.1 Address: 9725 SW Durham Road Occupant Load: 940 Area: 8,692 Sq Ft Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The following information is required prior to issuance of the Building Permit. FIRE- & LIFE - SAFETY 1. Provide Electrical sheets that indicate egress lighting. l� 2. Add note to clarify sprinkler under elevated platform, detail 8/4 or provide 1 hr, fire - resistive construction. (l . 3. Indicate rise and run for stairs on detail 1/6. STRUCTURAL 4. Clarify anchor bolt lengths for the shearwall schedule when not identified by other t/ details. For example, 6/S2.1. 5. Shearwall B on sheet S1.1 conflicts with detail 5/S2.1 for anchor bolt size & spacing.._ - 6. Clarify baseplate size for detail 9/S2.1. V 7. On detail 2/S4.1, 3 of the side plate lengths have not been identified. Please clarify. 1/ 8. Clarify bearing plate size for detail 5/S4.2.1---- 9. Clarify support for the 3 1/8 x 9 glulams that bear at gridline 7. Is it just a simple beam pocket? 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772