Correspondence FIE COPY
. .
•
,„„p„/„„,„„
May 15, 2004 `
CITY OF TIGARD
OREGON
W. Lane Brown
Southwest Church of Christ
9725 SW Durham Road
Tigard, OR 97224
RE: ADDITION OF NEW AUDITORIUM
Site Permit: BUP2004 -00164 Construction Type: V - 1HR
Tenant Name: SW Church of Christ Occupancy Type: A2.1
Address: 9725 SW Durham Road Occupant Load: 940
Area: 8,692 Sq Ft Stories: 1
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC)
1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999
edition. The following information is required prior to issuance of the Building Permit.
FIRE- & LIFE - SAFETY
1. Provide Electrical sheets that indicate egress lighting. l�
2. Add note to clarify sprinkler under elevated platform, detail 8/4 or provide 1 hr, fire -
resistive construction. (l .
3. Indicate rise and run for stairs on detail 1/6.
STRUCTURAL
4. Clarify anchor bolt lengths for the shearwall schedule when not identified by other t/
details. For example, 6/S2.1.
5. Shearwall B on sheet S1.1 conflicts with detail 5/S2.1 for anchor bolt size & spacing.._ -
6. Clarify baseplate size for detail 9/S2.1. V
7. On detail 2/S4.1, 3 of the side plate lengths have not been identified. Please clarify. 1/
8. Clarify bearing plate size for detail 5/S4.2.1----
9. Clarify support for the 3 1/8 x 9 glulams that bear at gridline 7. Is it just a simple
beam pocket?
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772