Correspondence iiem � e
'��
CITY ! FT9 : -
RESIDENTIAL PERMIT APPLICATION REVIEW OREGON
Permit Number: V V r , „ 0O�
. N o.:
Subdivi i . a.
_ � t
ddresc; j 3T` • i
II
ContactName irc. r
Ai
Bu4Mess
` Street
Cit 4 State O , r`�
Zip �,
As required by the 1999 Legislative action (Senate Bill 587), your residential permit application
and plans have been reviewed to determine if it is complete and if the plans are deemed
"simple" or "complex" as defined in ORS 455.467 and 455.469.
The application is complete.
The application is incomplete for the following reason:
I I The submitted plans will be reviewed; however, a permit cannot be issued until the
above information is reviewed and /or approved.
The submitted plans cannot be reviewed until the above information has been
submitted and /or approved.
The plans are deemed "simple ". The plans are deemed "complex ".
.If you have any questions please contact Loraine Williams at (503) 718 -2708.
4L) , o
Name of Plans Reviewer Date
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
September 22, 2006
George Teny
6685 SW Sagert St. #7
Tualatin, Oregon 97062
RE: New Single Family Dwelling
Project Information
Building Permit: MST2006 -00213 Construction Type: VN
Address: 9210 SW Edgewood St. Occupancy Type: R -3
Area: 2966 sq. ft. Stories: 1
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC)
2004 edition; the State of Oregon Residential Specialty Code ORSC) 2005 edition and the
Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. According to
RI06.1.1, construction documents should be of sufficient clarity to indicate that the location,
nature, and extent of work complies with the provisions of this code and acceptable engineering
practice. In order to satisfy this code provision, the following items require your attention in
order to complete this plan review:
1. The trusses submitted as a revision add load to window and garage headers, wall
framing, and foundation, please have designer or engineer resize and provide calculations
for these items.
2. The engineering pack includes calc for a FB -1, please clarify where this will be located.
3. The engineer and designer have both provided details, none of which are called out on
the plan, please submit revised pages adding details to appropriate sections on the plan.
When submitting revisions or additional information, please attach a copy of the enclosed City
of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking
and processing the documents.
Respectfully,
Loraine Williams,
Plans Examiner
(503) 718 -2708
Loraine @tigard - or.gov
1