Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
Aril 26 2004 " April CITY OF TI G,..3 John Westfal OREGON Dull Olson Weekes Architects 319 SW Washington Street, #200 Portland, OR 97204 RE: MECHANICAL EQUIPMENT @ SCIENCE REMODEL Project Information Building Permit: MEC2004 -00078 Construction Type: VN Tenant Name: Tigard High School Occupancy Type: E -1 Address: 9000 SW Durham Road The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2002 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99- 01) 1999 edition. The submitted plans are approved subject to the following. 1. Fume Hoods shall be inter - connected with the make -up air system. 2. Ductwork shall be supported in accordance with Sheet Metal & Air Conditioning Contractors National Association, Inc. (SMACNA) 3. Each appliance shall be provided with a shutoff valve separate from the appliance. The shutoff valve shall be located in the same room and within six feet of the appliance served. Access shall be provided to the shutoff valve. C409.5 OMSC 4. Equipment and appliances regulated by this code requiring electrical connections shall have a positive means of disconnect in accordance with the Electrical Code. 301.7 OMSC 5. Appliances serving different areas of a building other than where they are installed shall be permanently marked in an approved manner that uniquely identifies the appliance and the area it serves. 304.10 OMSC 6. Appliances shall be accessible for inspection, service, repair or replacement without removal of permanent construction. 306.1 OMSC 7. Appliances installed on roofs or elevated structures exceeding 16 feet in height shall be provided with a permanent means of access grade or floor level. 306.5 OMSC 8. Manufacturer's installation instructions shall be available on the jobsite at the time of inspection. 304.1 OMSC 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 9. Condensate from cooling coils or evaporators shall be collected and discharged to an approved plumbing fixture or disposal area. 307.1 OMSC 10. Smoke detectors shall be installed in return air systems with a design capacity greater than 2000 cfm. Upon activation, the smoke detector shall shut down the air distribution system. Smoke detectors shall be connected to a fire alarm system and shall activate an audible and visible alarm at a constantly attended location. 606.2, 606.4 & 606.4.1 OMSC 11. Suspended -type unit heaters/VAV's shall be supported by non - combustible elements that are designed and constructed to accommodate the weight and dynamic loads 920.2 OMSC Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and • essing the documents. Resp-.t lalo , Senior Plans Examiner l �� 26X10 SA 14X5 SA A : (TYP) 1:4X5 SA !�,' 24X SA �, sir i r i l I � + IIIIIM ".'„ 8 i SCIENCE I , dip ` M LAB _ B _ ' ;C AO 5'0 EXH w} 006 � : � L 150 CF � � f 41 •X22 EXH , Rely_ l • ifF 50 CFM Z. 1� s l r. (T OF 4 1u . ' : 26 10 EXH I N 0' ' l � � { =` (TYPIG OF •) 1 0 �:, 28X10 EXH silr LOCATE I NSIDC 1;.= VAV -14 el — • •••1®X10 E — 0 ' 5®m r F (J) "-� �cwl' wAIR?:1:I1�MEW i� I 4 4 T 1 1, I..■......... S n I C F i . II r i 2 4 . 2 ELECT 0 12 U 0 LOWER FLOOR HVAC PLAN-SC1ENCE SCALE 1/8" = I' -0" DULL U L L O L S O N W E E K E S architects pc Tigard High School - Addition / phases addendum one date march 11, 2004 ,' Remodel Phase I _: � project# 02054 = NA 1011-4 Alt! 'Vita T i , gard- Tualatin School District 9000 SW Durham Rd Phone (503) 431 -5400 r u y 319 SW WASHINGTON ST #200 PORTLAND, OR 97204 Tigard, OR 97224 - 5539 ® ; f 5x , � , f 503 226 6950 f ' 503 273 9192 www dawn com ® . I X FENCE x • A 1 0 cN LAB SCIEN E O n 11 05 SEE LAB N 4 ' t , (TYP) M� 104 8'm EXH 0 200 CF C14 � Ti !z r 50X10 LINED EXH f�� I rr, 30X16 LINED $ LAGGED .• • PLENU 15X15 EXH ��`` 15X15 EXH \ ''15® CFM mitt (TYP OF 2) - \L/ in —26X I— �_IISI I gratio 2X1-2-E ` 1— ° ��r )FRF 1E20 izj MO VAV- a A 16X16 EXH 1 , 107 f j� - j © S r j �I`� ��� (H) _ - j / I 10X10 EXH ►Pot B /i 680 CFM t =' L IM L tre '' •' I OXIO EXH L''� SA �� _ r �i�I�it.m. �� m ��i/ I�0 CFM i i \� /M INEu SA - El ' 36X16 LINED 6 LAGGED - ;/ 26XIQ L _ - -- _. -• - � NUM ■ I i1nu� ��. Am ��o�� � 1111�II��7 , � 1 LI Mks I: D i LAGGE I II .. L 2 "� SA A •OXI L,I :PUNR 26X10 SA rAP-P F' �E 2- �'O,RK — — V I— LOG�cT AT DUCT 40X12 LINED SA GAPPED FOR PHASE 2 ' ' ' ' ' ' ' ' ' STAIR NO. VAV BOX; SEE 2 I 0 (TYPICAL) i-'16.I • Nrr C 2 FLOOR MI2.2f/ SCALE I/8" = I' -0" -DULL OLSON WEEK ES T igard High School - Addition/ architects p c phase I (addendum one date Imarch 11, 2004 Remodel Phase I * fit project # 1 02054 , / lit t le Tigard - Tualatin School District 9000 SW Durham Rd Phone (503) 431 -5400 Tigard OR 97224 -5539 Z` 319 SW WASHINGTON ST #200 PORTLAND. OR 97204 9 `SR 1 503 226 6950 f 503 273 9192 www down corn r THRU TRUSS WEBBING 1 X )0N-1 10 I ,...,, SCIENCE LINE • • EXH LAB m , ‘ hh n tr . 2 6X10 EXH 2 6SX12 EXH (TYPICAL O FM Pil 1p MIMI vi 1 MIIIIIII - 1 6 X16 EXH � �� I XI- - . -- _m;• oc „� ..,� ii_ - �P = - , I 'y 1 _ __mama 1 �ir - OF - 2r —av' 7 F-. / � LINED a loi ci; : L 01111111Ww \ Ntir"A a ''I j i, - -f 20X14 LINED SA ' : 1(o C L� ! I Iii; _ � I- SA -� a � 3 vvi 0X16 LINED 3 0X16 LINED RA 110 CFM ri - - — - - - - - -- , II (K> r I \� Alli Mil I MIMI li AI I " (OUTSIDE) F A '' ( - I 30X16 LINED SA /RA iNAPPED it �l t THRU EXTERIOR WAL I, TO ABOVE ROOF FOR PHASE 2 ORK 52X16 LINED 8 LAGGED SA PLENUM 4.2 V UPPER FLOOR HVAC PLAN-SCIENCE M2.2 SCALE I/8" = I -O" DULL o c s o H WE e K e s Tig High S - Addition phase) addend one architects pc ii; R- Remodel Phase l date march 11,200 Tv pro)ect # 102054 lIllf Tigard- Tualatin School District 9000 SW Durham Rd Phone (503) 431 -5400 319 SW WASHINGTON ST #200 PORTLAND, OR 97204 Tigard, OR 97224 -5539 I 503 226 6950 f 503 273 9192 wm•w down com l ' LINEAR SLOT DIFFUSER RA GRILLE RA DUCT FROM TUNNEL UP IN CHASE J -45 COOLING DUCT d1 -.0--VVT BOX a ■■ ■ ■ ■■■ ■ U ■ ■ti ■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■ HEATING DUC.�T TYPICAL LONER FLOOR CLASSROOM DUCTWORK FOR REFERENCE ONLY ° BY: ''RR CHK'D: DATE: 3 -4 -04 TI GA .D S NO REVISION DATE A PHASE I Q MECHANICAL DUCT DEMO- LOWER FLOOR n_ _ 2007 S.B. ASH ST. ® JOB NO. NO. A PORTLAND 011. 97214 ph. 503- 234 -0548 1W 1 , 1 1 — 1 4 LINEAR SLOT DIFFUSER i RA GRILLE --\ f rE - EIL " '01_ COOL I NG DUCT —42.„,__ s... Es WT BOX_ HEATING DUCT b 1 I MN 111111■11•11Mi _ _ ( 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 L UUULUI ILLLLUI LLLULI ILUHU TYPICAL MAIN FLOOR CLASSROOM DUCTWORK * * FOR REFERENCE ONLY r: RIR. CHK 'D: DATE: 3 -4 -04 TIGA RD ) REVISION DATE PHASE I MECHANICAL DUCT DEMO— MAIN FLOOR s • JOB NO. 2007 S.E. ASH Sr. INC. SHEET NO. ,_ PORTLAND OR. 97214 ph. 503- 234 -0548 1W 1 . 1 1 --2 MAY -0? -2004 12:01 DOWA 5032739192 F :02/02 D U L L " O L S O N W E E K E S A R C H I T E C URE + INTERItlR + PLANNII architects inc. (J / (l C /JX6 ff DATE: May 06, 2004 TO: Brian Blaylock City of Tigard John Williams City of Tigard Hap Watkins City of Tigard FROM John Westfall DOWA COPY: Jim Little Robinson Construction Craig Markus Cornerstone Construction Management Scott Killer MFIA Consulting Engineers Mark Kubiaczyk Tigard High School PROJECT: MEC2004 -00078 Tigard HS Science Remodel RE: Plumbing Permit - Science Classroom Uses As requested by the City of Tigard, we are directing the Contractor to provide and install "acid waste piping" in all Science Labs, as shown in the Phase I Drawings. Please note that this letter will supersede our earlier letter dated April 26, 2004. The piping shall be: Polypropylene plastic pipe, ASTM D2447 or ASTM D4101. Fittings and shall be compatible with the piping system and with equal or better acid resistance and, unless otherwise indicated, made by the piping manufacturer and recommended for the service indicated. Jointing methods shall be with manufactured standard mechanical joint coupling system. r�l The Phase 2 chemistry classrooms will have acid- resistive piping as specified above. Please let me know if you need anything further to clear up this matter. We would appreciate it if the plumbing ., • 't could be rel. • d after you review this memo. Sincerely, ' John Westfall Project Manager, Dull Olson Weekes Architects TOTAL P.02 MAY -07 -2004 12 01 DOWA 5032739192 F!.01/02 D U L L O L S O N W E E K E S ARCHITECTURE + INTERIORS + PLANNI architects pc DATE 5/07 •FAQ% OMAs °COURIER 0 .. O PER YOUR REQUEST 0 POR YOUR Review/ ODMMENT OFOR YOUR APPROVAL / SIGNATURE 0 FOR YOUR USE PROJECT: Tigard High School Additions and Remodel PROJECT NO.: 02054 TOTAL PAGES: COPIES DATE: # DESCRIPTION 1 Memo regarding acid resistance piping at Science I I I I I I I I I OWNER LANDSCAPE CONSULTANT ACOUSTICAL ENGINEER Tigard Tualatin School District Atlas Landscape Architecture CS Acoustical Engineering 6960 SW Sandburg Road 320 6th Ave Suite 310 833 SW 1 lth Suite 808 Tigard, OR 97223 Portland, OR 97204 Portland, OR 97205 (503) 431 -4000 Fax (503) 431 -4047 (503) 224 -5238 Fax (503) 224 -5239 (503) 227 -6233 Fax (503) 227 -4863 O Stephen Poage 0 Nick Wilson 0 Cliff Sroka e -mash a poagc(gstsdkl2.or.us e-maik ,pjek'oadas- la.cora s- mail: clifireesaeousticaLcom PROJECT MANAGER CIVIL ENGINEER TECHNOLOGY CONSULTANT (TTSD) Cornerstone Construction Management SJO Consulting Engineers Northwest Information Services 5331 SW Macadam Suite 377 6650 SW Redwood Lane Suite 360 10300 SW Greenburg Road Suite 280 Portland, OR 97201 Tigard, OR 97224 Portland, OR 97223 (503) 295 -0108 Fax (503) 295 -1896 (503) 226 -3921 Fax (503) 226 -3926 (503) 246 -8585 Fax (503) 246 -8706 O Rick Rainone 0 Craig Markus 0 Mark Whams, 0 Jim de Land e e - mail: mwb atry "oen corn rcr .stoneni c I l g hmaik 11 ' Q • ,from - CM /GC STRUCTURAL ENGINEER PLANNING CONSULTANT • /Oa i Robinson Construction Co. Nishkian Dean Ed Murphy & Associates 21360 NW Arnberwood Drive 319 SW Washington Street Suite 720 9875 SW Murdoch Street Hillsboro, OR 97124 Portland, OR 97204 Tigard, OR 97224 (503) 645 -8531 Fax (503) 645 -5357 (503) 274 -1843 Fax (503) 273 -5696 (503) 624 -4625 Fax (503) 968 -1674 O Jim Little, Project Manager 0 Jerry Gotchall O Ed Murphy e- mail: Jiml(2robcon.com e - mail.• graald ).nishldan.coat e-mail: eJmutphy(aol corn SCHOOL SITE MECH. /ELECT, ENGINEERS COST CONSULTANT Tigard High School MFIA Rider Hunt Levett & Bailey 9000 SW Durham Road 2007 SE Ash Street Fox Tower, 805 SW Broadway, Ste. 2750 Tigard, OR 97224 Portland, OR 97214 Portland, Or. 97205 (503) 431 -5400 Fax (503) 431 -5410 (503) 234 -0548 Fax (503) 234 -0677 (503) 226.2730 Fax (503) 226.1267 O Mark Kubiaczyk, Principal 0 Scott Miller (Mech) o Graham Roy e mask rnk_ ublaczyf)ttedkl2.nr us e-mail: 1cott mlllesernl7a -en .coma e Froyrer de rhuntrnm CITY OF TIGARD 0 Steve Smith (Elect) e -mail: stev smit�jg/l eng:cor FROM: 13125 SW Hall Blvd. DULL OLSON WEERES ARCHITECTS Tigard, OR 97223 0 Keith Johnson AIA, Project Manager (503) 6394171 Fax (503) 684 -7297 e-mail keith/(g7dowa,com O Brad Kilby AICP Planner O ohn Wes e-maik bradley®ci tiganierrrr J t{A((, Project Architect e - mall: lash niadream.rnm 0 Brian m om. i r Blaylock Plans Examiner 0 Mike Wilson CSI, CDT, Specifier e-aagteLetardanos e-mail: rnike dow a ._c_»_ m COMMENTS: C•IDocurnonla and Sattingaljohn w nalfs Doa eoptProj Tranamiftal.doe a R C I .I P r+ T T ID A u Q RA t T T A t 319 SW WASHINGTON ST. 5200 1 PORTLAND, OR 9720 r Sent By: MFIA INC; 5032340677; Apr -20 -04 15:24; Page 1/8 M CONSULTING ENGINEERS Phone (503) 234 -0548 F 2007 SE Ash Street Fax (503) 234 -0677 Portland, OR 97214 Email: email @mfia- eng.com INC. To: Keith Johnson Date: 4/20 /2004 DOWA From: Scott Miller Job No.: 7104A1 Project: Tigard High School Plumbing Plan Review WE ARE SENDING: Drawings (plans) ❑ Specifications ❑ Submittals/ shop drawings ❑ Disk ❑ Drawings (originals) // Letter /memo ❑ Change order ❑ Other VIA: ❑ US Mail ❑ UPS ❑ Messenger ❑ Other ® Fax Fax No.: Total *of Pages: R Message / llescription TRANSMITTED AS INDICATED BELOW: n For your use ❑ As requested El For review /comment El For approval ICC: John Williams, City of Tigard 503/6114 -7297 _ Sent By: MFIA INC; 5032340677; Apr -20 -04 15:24; Page 2/8 • M John van Bladeren, P.E. James L. Tormey, P.E. FI Robert L. Connell, P.E. A l 1 Scott Miller, P.E. Steven W. Smith, Associate INC. CONSULTING £NG[NEERS • 2007 SE Ash St., Portland, OR 97214 • (503) 234 0548 • fax (503) 234 -0677 April 20, 2004 MEMO TO: Keith Johnson DOWA SUBJECT: Tigard High School Plumbing Plan Review The following is my response to the plumbing plan review comments from John Williams with the City of Tigard (see copy attached). Plan Sheet P2.21, Item #2 — Multi- connections to sink tailpiece: Comment: Not approved. Provide approved indirect water receptor for indirect water from backflow prevention device and D.1. equipment. Response: See attached drawings modifying design. A primed hub drain will be provided for waste from all devices except dishwasher. These drawings were made part of the contract documents. Plan Sheet P5.21, Item #5 — Fume hood vacuum breaker 1 cold water: Comment: Piping shall be located outside fume hood. Fume hood shall be installed per manufacture's installation standards_ Response: The detail shows a section and elevation view. The section view is misleading in showing the vacuum breaker. The vacuum breaker is located outside the fume hood. Additional Items: A) We contacted Pete Gayerka with Clear Water Services. He indicated the waste control was to he a user monitored program. No special provision to the system for acid neutralization is required. Engineering Excellence shoe 1945 Sent By: MFIA INC; 5032340677; Apr -20 -04 15:24; Page 3/6 B) The science classrooms are not being used as chemistry classrooms once phase 11 is completed. Phase II is scheduled for completion in 2005. The science classrooms will be used for physics and biology. We do not believe acid waste piping is necessary for these functions. MFIA, Inc, 14 cott Miller SWM/rjb Cc: John Williams, City of Tigard Sent By: MFIA INC; 5032340677; Apr -20 -04 15:25; Page 4/8 • SETTING THE STANDARD FOR SERVICE EJtCELISNCE • Facsimile To: K . T0tw ee Company: Dist Q w , e e.ICer Are4;`ter4' Phone: S 2 a 6 — L 9 So Fax: X03 2 73 on ct a ice'"_ From: • • Company: Cary of Tigard Phone: (503) 639 -4171 ..512.3 6-rwr/ ($b3 7 is Y 2 4,'/ M; Et Ow), - � Fax: (503) 684 -7297 • Date: T31$10 Pages including this pagc: I _ COMMENTS: P1 6:�. V %i., RLv:4.v Rea • ae / Tina SerLoo! DOc sic f ��q►� U.art t. /?' CoaisAtt''4' To .S j ,.K Teri / Pie Hair A ! h 0.4.4 W" l eo 4a✓ Fee . ai ensd6' b401,,-.4t ►..% 6 F t... Ps-- . DX- 114b S'!+.czt P .S• 2. _ /40 ®di wracyzrc ,9 8 r e.1c✓ 'co ! o& " 4 `.i i % Lo s - F14"e flood, Nam o I i. . a _erg. ref* d i 111 ; a L:R i i'J &+t of , - tc C er id .. SC/ v r'e N. elow.1 4=t so 3 Gr I - s ' S Aro.'1-w d � A tJde►�c it) t a n - 0 0 • e i c . . k %O. Td S a - 1 - . V tj ewe /i - (Myer SW Hall Blvd:, TWA OR 97223 - }w :.. e: PLEASE DELIVER T IIS FAX IMMEDIATELY TOTAL P.02 Sent By: MFIA INC; 5032340677; Apr -20 -04 15:25; Page 5/8 • • SINK FLEX IP "AIN LINE TO DISHWASHER 3/4" WASTE FROM RP DEVICE / ■ ANI /OR P1 UNIT 3/4" VENT LINE AIR GAP FITTING 1 TRAP JF2 SMITH 3812 \_ ♦• TO TRAP PRIMER 1 3/4" WASTE ON • PREP ROOM SINK p 7 F: c ;C;HFMATI< • U u L L W E E K E S T Nigh Sch - Addit ! pnesel!addendum one a rc F ilrcfr pc date 'march 11,2004 Remodel Phase I ro• b 02054 lo" I Tigard- Tualatin School District 9000 SW Durham Rd Phone (503)431 -5400 R P 1 919 0w wASnIn l CTUN 5T OM voAluNC, GA 97204 igazd, OR 5727b5539 ■ 503 229 4 0 0 l: 502 273 9192 • - •• r do • a Sent By: MFIA INC; 5032340677; Apr -20 -04 15:25; Page 6/8 • 1 1 7ISHWASHER 3/4" WASTE FROM RP DEVICE yASTE FROM RP DEVICE AND /OR DI UNIT ?R 171 UNIT = NT L INE I -1 /4" ' AIR GAP FITTING WASTE DN o u Lt. O L S O rf W E f K E5 Tigard High School - Addition / Pnase addendvmone u rc hifec'fJ QC Remodel Phase data march 11, 2004 ectR 02054 / 011 1 Tigard- Tualatin School District 9000 SW Durham Rd Phone'. (503) 431 -5400 R P 2 319 2.w WAZ11INGTON :T. X606 PORTLAND OR 07261 Tigard, OR 97224.5,539 ■ 7' 901 220 6030 1 567 22? 019? ,awr de,••• . vow • Sent By: MFIA INC; 5032340677; Apr -20 -04 15:26; Page 7/8 • • «Y NOTES THIS SHEET (A)_ 2" WASTE DOWN AND I -I/2" VENT UP, COORDINATE DROP AND RISER WITH HVAG DUCTWORK ON BOTH FLOORS PRIOR TO COMMENCING ANY WORK, 0 - 1/2" COLD AND HOT WATER DROP TO FLOOR BELOW, COORDINATE LOCATION OF DROP WITH HVAC DUCT WORK ON BOTH FLOORS PRIOR TO COMMENCING ANY WORK, ROUTE DOMESTIC PIPING UNDER COUNTER AGAINST BACK OF CABINET. (E) - 2" WASTE DOWN, I -1/2" VENT UP AND I-I /4" COLD WATER UP FOR EMERGENCY WASH AREA. COORDINATE WITH HVAG DUCT WORK ON BOTH FLOORS PRIOR TO COMMENCING ANY WORK. (D)- SEE PLUMBING RISER 3/P2.2I FOR SIZING AND ROUTING. i E - 1/2" RP DEVICE WITH WALL ACCESS PANEL. ROUTE FUNNEL DRAIN TO INDIRECT WASTE RECEPTOR. ROUTE I/2" DISCHARGE TO ICE MACHINE AND DI EQUIPMENT. CF PROVIDE 1/2" STOP IN WALL BOX FOR DI EQUIPMENT. ROUTE DI DRAIN TO INDIRECT WASTE RECEPTO' ® - PROVIDE 1/2" STOP IN WALL BOX FOR WATER CONNECTION TO REFRIGERATOR ICE MACHINE. COORDINATE WITH GAS AND - - . ' z,•, • ■ • - - G IN WALL. n H - SEE DETAIL 2/P2,21 FOR INDIRECT WASTE RECEPTOR PIPIN4 , f \ U - NOT USED • {� - 4" OD 8 4" RD UP THRU ROOF TO L- i 1. _1 ; SEE SHEET M2.4 D U L L O L S O N W E E N E 5 Tigard High School - Addition / ehase I 1 addendum one ar'chrfeCtA pc date march 11,2004 Remodel Phase I project #! 102054 Ion Tigard- Tualatin School District 900D SW Durham Rd Phone. go) 431 -5400 R P 1 . 3 Tigard, OR 97224-5539 3rD SW WASNNNTON ST MO L PORTLAND rM s72DA L 601 22 l9S6 1503 215 9494 ...n+ down .n. _ Sent By: MFIA INC; 5032340677; Apr -20 -04 15:26; Page 8/8 [ • --..■.....---... , • ..■■.. . ■ . 4 - . . • ■ I /2" GW AND HW INTO CABINET TO RP I-I/ -" VENT INTO JOI T WEBBING. I r:L [5 -!1 1 �R�� > INDIRECT WA5TE RECEPTOR FOR RP DEVICE/ DI EQ P „ ND 1/2" HW , ' ' J W I N 015T WEBBING 2" WASTE DOWN IN HALL, TO RP > ..; 5 -1 „�� > ll , '2” CH AND FIN INTO CABINET 0 :' •" A TE LINE IN WALL UNDER I 1 FIR . I GTWORK, 2" WASTE IN TUNNEL INDIRECT INASTE RECEPTOR FOR RP DEVICE/ D1 EQUIP C PREP ROOM PLUMBING RISER -� TYP ( E. 5GHEMATIC, • 0 U L f_ O L S O N W E E K E S Ti H School - Add / phasal 'adderldumwle a h fcrfrci Pa date Imanch 11. 2004 Remodel Phase I • project# 02054 I / Tigard- Tualatin School District 9000 SW Durham Rd Phone: (503) 431 -5400 R P 1 . 4 Tigard, OR 9722+-5539 512 SW WA511124 1116 Yl ■920D PORTLAND, OA 17204 r. 566 226 6956 / 303 2r2 9192 1 r- iawa co..