Plans RECEIVED � arma/m kt,
Form 2a Project Name Tigard HS- Busines, / pchnology Remodel I Page:1 11
MAR 1_0 atiJ SUMMARY
Project 1 Project Name BUILDIl`W9 114 i\4S'SiQSineSS/ Technology Remodel
2. Project Address 9000 SW Durham Rd
3. City /Town Tigard 5. County i Washington '
4. Building, Gross Area (ft2) 9,700 6. No. of Floors 1
7. Construction Site Elevation Above 2,000 ft? EKES 0 NO
Attached Chapter Type ID Description Attach
Forms and Building Envelope Form 3a Building Envelope - General El
3b Prescriptive Path - All Climate Zones ❑
Worksheets Worksheet 3a 'Wall U- factor ❑
3b Roof U- factor ❑
Check boxes to 3c Floor U- factor ❑
indicate attached 3d W.indow /Skylight Schedule ❑
forms and Systems Form ' 4a Systems - General 0
worksheets 4b ,Complex Systems ❑ ,
Worksheet 4a Unitary Air Conditioners - Air Cooled ❑
4b Unitary Air Cond. - Water & Evap Cooled ❑
4c Unitary Heat Pump - Air Cooled ❑
4d Unitary Heat' Pump - Water Cooled ❑
4e Packaged Terminal A.C. - Air Cooled ❑
4f Packaged Terminal Heat Pump - Air Cooled ❑
4g Water Chilling Pkgs - Water & Air Cooled ❑
4h Heat Rejection Equipment ❑
4i Boiler - Gas -Fired and Oil -Fired ❑
4j Furnace & Unit Heaters - Gas and Oil -Fired ❑
• 4k Simultaneous,Heating and Cooling ❑
41 Air Transport Energy ❑
4m Natural Ventilation ❑
Lighting Form 5a Lighting - General 0
5b Interior Lighting Power - Tenant Method 0
5c Int. Ltng Power - Space -by -Space Method ❑
Worksheet 5a Lighting Schedule p
5b Interior Lighting Power •
Applicant 7. Name 10. Telephone
8. Company 11. Date
9. Signature
Attached No. of Pages Description of Documentation
Document-
ation
Summary040104 xIs
•
Form 3a Project Name' Tigard HS- Business/ Technology Remodel Page:
BUILDING ENVELOPE - GENERAL
Check'all boxes 1. Exceptions (Section 1312)
that apply El No Envelope Components The building plans do not call for new or altered building envelope
components, e.g., walls, floors or roof /ceilings.
❑ A Non - conditioned Building. The proposed structure has no spaces heated or cooled by
an HVAC system.
Exceptions ❑ Exception. All new or altered building envelope components do not comply with the
Discussion of qualifying requirements, Section 1312, but qualify for Exception 1 ❑ 2 ❑ 30 4 ❑ 5 ❑
exceptions in Portions of the building that qualify:
instructions section
The plans /specs show compliance in the following locations:
2. Air Leakage (Section 1312.1.1)
Plans /Specs ❑ Complies. Plans require that penetrations in the building envelope are sealed and that
Show compliance by windows and door are caulked, gasketed or weatherstripped.
including a drawing
sheet, detail number, The plans /specs show compliance in the following locations:
specification section
and /or subparagraph
3. Suspended Ceiling (Section 1312.1.2.1)
❑ Complies. Building plans do not show suspended ceilings used to separate conditioned
space from unconditioned space. No exceptions permitted.
4. Recessed Light Fixtures (Section 1312.1.2.2)
❑ Complies. The building plans do not show recessed light fixtures installed in ceilings
separating conditioned spaces from unconditioned spaces.
❑ Exception. The building plans require that fixtures installed in direct contact with insulation
be insulation coverage (IC) rated. The plans /specs show compliance in the following locations:
5. Moisture Control (Section 1312.1.4)
❑ Complies A one -perm vapor retarder is installed on the warm side (in winter) of all exterior
floors, walls and ceilings, and a ground cover is installed in the crawl space for both new and
existing buildings where insulation is installed.
The plans /specs show compliance in the following locations:
❑ Exception. All new or altered building envelope components do not comply with the vapor
retarder requirements of the code, but qualify for an exception. Note applicable exception.
Section 1312.1.4 Exception 1 ❑ 20
Portions of the building that comply
Climate 6. Climate Zones
Zones ❑ Zone 1 - A building site is in Climate Zone 1 if its elevation is less than 3000 feet above
sea level and it is in one of the following counties: Benton, Columbia, Clackamas, Clatsop,
Coos, Curry, Douglas, Jackson, Josephine, Lane, Lincoln, Linn, Marion, Multnomah, Polk,
F Tillamook, Yamhill, or Washington
❑ Zone 2 - Building sites not in Zone 1, or where construction site elevation is 3000 feet or
higher in Zone 1, are in Zone 2.
3 -1
Form 4a Project Name: Tigard HS- Business/ Technology Remod Page: 11
SYSTEMS - GENERAL
Applicability Plans /Specs
Discussion of qualifying Show compliance by including a drawing sheet, detail
exceptions on page 4 -14 number, specification section and subparagraph
1. Applicablity (Section 1317)
Is this'form required?
❑ Form Required. Complete form if a new HVAC system is being installed, or
components of an existing HVAC system are being replaced (I.e., equipment, controls,
ductwork, and insulation.)
❑ Exception. The building or part of the building qualifies for an exception
from HVAC code requirements. Applicable code exception is
Section 1317.1. Portions of the building that qualify.
Area: Exception 1 ❑ 2 ❑ 3 ❑
Area: Exception 1 ❑ 2 ❑ 3 ❑
Area: Exception 1 ❑ 2 ❑ 3 ❑
l] Form Not Required. This project does not contain work required to comply with code.
2. Simple or Complex Systems (Section 1317.9 or 131 - 7.10)
❑ Simple System. Building contains only Simple HVAC System(s). Complete this
form (4a) and equipment efficiency worksheets as required. Form 4b is not - required.
❑ Complex System. Project includes a Complex System. Complete this form (4a),
form 4b and equipment efficiency,worksheets as required.
3. System and Zone Controls (Section 1317.4.1 and 1317.4.2)
El Complies. All new HVAC systems include at least one temperature control device
responding to temperatures within the zones
❑ Exception. HVAC system qualifies for an exception from zone control requirements.
The applicable code exception is Section 1317.4.2, Exception 1 ❑ 2 ❑
Portions of the building that qualify
The plans /specs show compliance in the following locations:
4. Control Capabilities (Sec. 1317.4.2.1)
❑ Complies. Zone thermostats are capable of being set to the temperatures
described in Sec. 1317.4.2.1. Where used to control both heating and cooling, zone
controls shall be capable of providing a temperature range or deadband of at least
5 degrees F within which the supply of heating and cooling energy to the zone is
shut off or reduced to a minimum.
❑ Exception. The building qualifies for an exception to the deadband requirements.
The applicable code exception is Section 1317.4.2.1 Exception 1 ❑ 2 ❑
Portions of the building that qualify:
The plans /specs show compliance in the following locations:
4 -1
7104a5- HVAC2004 Forms xis March 1, 2004
Form ' Project Name Tigard HS- Business/ Technology Remodel Page 1
LIGHTING - GENERAL
1. Interior Exceptions (Section 1313.1)
Exceptions ❑ No Interior Lighting. The building plans and specifications do not call for new or
altered interior lighting Skip to item 5, Exterior building Lighting - General, below
Discussion of qualifying
exceptions in instructions ❑ Exceptions. 1 The building or part of the building qualifies for an exception from
code lighting requirements Applicable code exception is number
2 Lighting equipment that qualifies for an exception - in addition to general lighting and is
separately controlled. Applicable code exception is number
Areas of the building and equipment that qualify for any exceptions
Plans /Specs
Show compliance by including 2. Local Shut - off controls (Section 1313.3.1.1)
a drawing sheet, detail number, ❑ Complies At least one local shut -off lighting control for every 2,000 square feet of
and /or specification section
and subparagraph lighted floor area and for all spaces enclosed by walls or ceiling height partitions
This control(s) is detailed in the building plans on drawing number E2.11
❑ Exception. The building or part of the building qualifies for an exception.
Applicable code exception is Section 1313 3 1 1, Exception.
Portions of the building that qualify
3. Automatic Shutoff Controls (Section 1313.3.1.2)
❑ Not Applicable. Office floor area is not over 2,000 square feet of contiguous office
floor area or permitted space'is not over 5,000 square feet No offices less than 300 square feet, meeting
or conference rooms, or school classrooms
▪ Complies All interior lighting systems are equipped with a separate automatic
control to shut off the lighting during unoccupied periods Offices less than 300 square feet,
meeting and conference rooms, and school classrooms shall be equipped with
occupancy sensors that comply with Section 1313.3 1.2 1
Compliance details in plans /specs' SHEET E2.11 - SPEC SECTION 16900
❑ Exception. The building or part of the building qualifies for an exception The
applicable code exception is Section 1313.3 1,2, Exception
Portions of the building that qualify
4. Daylighting - Controls (1313.3.1.3)
❑ No classrooms or atriums with skylights or window to wall ratio greater than 50%.
O Complies. All classrooms and atriums with window to wall ratio greater than 50% and /or
Exterior skylights are equipped with automatic daylight sensing controls, as required by Section
Building 1313 3 1 3 1 and Section 1313.3.1.3.2 The daylight sensors specified comply with
Lighting Section 1313 3 1 3 3.
is lighting directed to
illuminate the exterior Compliance details in plans /specs: SHEET E2.11
of the building and
adjacent walkways and
loading areas with or
without canopies 5. Exterior Lighting (Section 1313.5)
O Complies The plans do not call for incandescent or mercury vapor lamps for use
on building exterior.
Clock ❑ Exception. The building plans indicate luminaires with incandescent or mercury vapor
Switches shall lamps, but they are specified for use in or around swimming pools, water features, or other
be astronomic locations subject to the requirements of Article 680 of the 2002 National Electrical Code
(seasonal correcting)
type with separate
programs for each day
of the week and shall 6. Exterior and Canopy Lighting Controls (Section 1313.3.2)
store maintanergyto O Com lies. The building plans and specifications include photoelectric and /or clock
maintain timekeeping p g p p p
during power outages switches on all exterior lighting systems which are designed and programmed to
extinguish lights when daylight is present, as required by Section 1313 3 2
p 7. Interior Connected Lighting Power (Section 1313.4)
� YES Complies The interior lighting power does not exceed the interior power allowance established
in either the Tenant Space Method (Form 5b) or the Space -by -Space Method (Form 5c)
r• Tenant Space Method (Form 5b) r Space -by -Space Method (Form 5c)
5 -1 - - -
LlghtingForms040104 xis
Form 5b , ' Project Name Tigard HS- Business/ Technology Remodel Page 2
INTERIOR LIGHTING POWER - Tenant Space Method
Lighting (a) (b) (c) (d)
'Budget
Tenant or Building Type Floor Area (sq ft)
Occupancy/ (Table -13G) Max Power
Use Types Lighting Power
See instructions for Density (W /ft Budget (W )
tlescnption of S chool /University
occupancy types 15,890 1 1 17,479
Lighting 1 Total Interior Lighting Power Budget (Watts) for Building. 17,479
Power
Budget
2 Total length of track lighting (ft)
3 Line 2 multiplied by 37 5 Watts /ft
Track
Lighting 4 Total amperage of circuit breaker(s) serving track lighting (amps) -
Power 5 Voltage of circuit breaker serving track lighting (volts) -
6 Maximum wattage of track lighting (multiply line 4 by line 5)
7 Track Lighting Power (lesser value of line 3 or line 6)
Building's 8 Track Lighting Power (line 7)
Lighting 9 Total Interior Lighting Power from Worksheet 5b -1 (Sum of Column (m)) + 16,474
Power 10 Total Adjusted Lighting Power (line 8 + line 9) = 16,474
11 Does design meet budget? Line 10 must be no greater than line 1 YES
5 -2
LightingForms040104 xls
Worksheet 5a Project Name Tigard HS- Business/ Technolo! Page' 3
LIGHTING SCHEDULE
(a) (b) (c)' (d) (e) (f)
Lum Luminaire Lamp Ballasts Luminaire Is Luminaire
ID I Power From
Type Description No Description No Description (watts) Table 5c
A Fluorescent T8 - 4 foot 3 -F32T8 ELECT NO 93W 3 F32T8 1 Electronic Normal Output. RS 93 YES
Al Fluorescent T8 - 4 foot =; 3 -F32T8 -ELECT NO -93W 3 F32T8 1 Electronic Normal Output. RS 93 YES
C1 Fluorescent T8 - 4 foot 3 -F32T8 -ELECT NO -93W A 3 F32T8 1 Electronic Normal Output RS 93 YES
C2 Fluorescent T8 4 foot,, 2-F32T8-ELECT NO 62W i 2 F32T8 1 Electronic Normal Output RS 62 YES
F
Fluorescent T8 - 4 foot 2 -F32T8 -ELECT NO -62W id. 2 F32T8 1 Electronic Normal Output. RS 62 YES
G Fluorescent T8 - 4 foot 3 -F32T8 -ELECT NO -93W , 3 F32T8 1 Electronic Normal.Output RS 93 YES
G1 Fluorescent T8 - 4 foot 3 -F32T8 -ELECT NO -93W y 3 F32T8 1 Electronic Normal Output RS 93 YES
H Compact Fluorescent Triple , 1- CFTR32WGX24q -3- ELECT -35W 1 CFTR32WGX24q -3 1 Electronic 35 YES
—
J Fluorescent T8 - 4 foot 1 -F32T8 -ELECT NO-31W 1 F32T8 0 5 Electronic Normal Output RS 31 YES
j
4
A 7
A
-Z
_i -
A
I{ A
7.
LightingForms040104 xls
Al • i
Worksheet 5b - PFoject Name Tigard HS- Business/ Technology Remodel Page I 4 1
INTERIOR LIGHTING POWER
I
Space -by -Space Method Only
Skip to column (f) if using the Tenant Space Method (f)
(a) (b) (c) (d) (e) Lum ID (g) (h) (I) (I) (k)
from Quantity of
Room ID (do Space Type Space Lighting Power Worksheet Luminaires (or Luminaire Lighting Room
not leave any ,Area (Table 13 -H) Type Budget 5a Column lineal ft for track Power Exempt Power Total Ltg
blanks) (ft') (enter space type only once per room) LPD (b) x (d) ( lighting) (Watts) Fixtures (g) x (h) Power
Each room must -- -- A 'a 76 93 ❑ 7,068 -
be identified -- -- Al J 21 93 ❑ 1,953 --
Describe
luminaires for -- -- Cl J 41 93 ❑ 3,813 —
each individual -- -- C2 A 9 62 ❑ 558 —
room in plans -- -- F A 1 62 ❑ 62 --
-- -- G ' -I 26 93 ❑ 2,418 --
-- -- 01 2 93 ❑ 186 —
-- -- H 11 35 El 385 --
-- -- J 1 31 ❑ 31 --
For iracklighting enter
lineal feet In column -- -- — - ❑ _ --
column (g) A ]] ❑ -- Column (k), enter sum J ❑
of column onfor each __ __ _ _ __
room only once at first ❑
entry for the room See __ -- J - ❑ - --
example In Instructions �{
J - ❑ _ __
__ __ V_1 - ❑ _ __
H - ❑ _ __
__ __ _1 - ❑ _ __
__ -- -_31 - ❑ - __
_ F I - ❑ - —
__ __ _1 _ ❑ - __
H _ ❑ _ __
-- -- & ❑
__ -- J - ❑ - __
__ _- - _ ❑ - __
__ _- .d, - ❑ - -_
A - ❑ - __
J - ❑ - __
__ __ _1 - ❑ - __
Other Pages - Worksheet 5b -1 Total Budget - Wksht 5b -1 Total Lighting Power (excluding exempt/track fixtures) 16,474
Lot the additional
worksheets necessary to
catalog all luminaires In
building Total Number of Additional Worksheet 5b I 0 z d
WI) n
Worksheet Number Lighimg Power Budget Space -by- Proposed Bwdmg Lighting Power Area Sqft (not required for
Space only (Total of column (e)) (Total of column (k), excluding Tenant Method)
exemotftrack)
5b -1 - 16,474 -
5b-2
5b -3
Sum of additional 5b worksheets
\ :r� >o� Total Budget (of all worksheets) - 16,474 -
5 -5
LightingForms040104 xis