Loading...
Plans RECEIVED � arma/m kt, Form 2a Project Name Tigard HS- Busines, / pchnology Remodel I Page:1 11 MAR 1_0 atiJ SUMMARY Project 1 Project Name BUILDIl`W9 114 i\4S'SiQSineSS/ Technology Remodel 2. Project Address 9000 SW Durham Rd 3. City /Town Tigard 5. County i Washington ' 4. Building, Gross Area (ft2) 9,700 6. No. of Floors 1 7. Construction Site Elevation Above 2,000 ft? EKES 0 NO Attached Chapter Type ID Description Attach Forms and Building Envelope Form 3a Building Envelope - General El 3b Prescriptive Path - All Climate Zones ❑ Worksheets Worksheet 3a 'Wall U- factor ❑ 3b Roof U- factor ❑ Check boxes to 3c Floor U- factor ❑ indicate attached 3d W.indow /Skylight Schedule ❑ forms and Systems Form ' 4a Systems - General 0 worksheets 4b ,Complex Systems ❑ , Worksheet 4a Unitary Air Conditioners - Air Cooled ❑ 4b Unitary Air Cond. - Water & Evap Cooled ❑ 4c Unitary Heat Pump - Air Cooled ❑ 4d Unitary Heat' Pump - Water Cooled ❑ 4e Packaged Terminal A.C. - Air Cooled ❑ 4f Packaged Terminal Heat Pump - Air Cooled ❑ 4g Water Chilling Pkgs - Water & Air Cooled ❑ 4h Heat Rejection Equipment ❑ 4i Boiler - Gas -Fired and Oil -Fired ❑ 4j Furnace & Unit Heaters - Gas and Oil -Fired ❑ • 4k Simultaneous,Heating and Cooling ❑ 41 Air Transport Energy ❑ 4m Natural Ventilation ❑ Lighting Form 5a Lighting - General 0 5b Interior Lighting Power - Tenant Method 0 5c Int. Ltng Power - Space -by -Space Method ❑ Worksheet 5a Lighting Schedule p 5b Interior Lighting Power • Applicant 7. Name 10. Telephone 8. Company 11. Date 9. Signature Attached No. of Pages Description of Documentation Document- ation Summary040104 xIs • Form 3a Project Name' Tigard HS- Business/ Technology Remodel Page: BUILDING ENVELOPE - GENERAL Check'all boxes 1. Exceptions (Section 1312) that apply El No Envelope Components The building plans do not call for new or altered building envelope components, e.g., walls, floors or roof /ceilings. ❑ A Non - conditioned Building. The proposed structure has no spaces heated or cooled by an HVAC system. Exceptions ❑ Exception. All new or altered building envelope components do not comply with the Discussion of qualifying requirements, Section 1312, but qualify for Exception 1 ❑ 2 ❑ 30 4 ❑ 5 ❑ exceptions in Portions of the building that qualify: instructions section The plans /specs show compliance in the following locations: 2. Air Leakage (Section 1312.1.1) Plans /Specs ❑ Complies. Plans require that penetrations in the building envelope are sealed and that Show compliance by windows and door are caulked, gasketed or weatherstripped. including a drawing sheet, detail number, The plans /specs show compliance in the following locations: specification section and /or subparagraph 3. Suspended Ceiling (Section 1312.1.2.1) ❑ Complies. Building plans do not show suspended ceilings used to separate conditioned space from unconditioned space. No exceptions permitted. 4. Recessed Light Fixtures (Section 1312.1.2.2) ❑ Complies. The building plans do not show recessed light fixtures installed in ceilings separating conditioned spaces from unconditioned spaces. ❑ Exception. The building plans require that fixtures installed in direct contact with insulation be insulation coverage (IC) rated. The plans /specs show compliance in the following locations: 5. Moisture Control (Section 1312.1.4) ❑ Complies A one -perm vapor retarder is installed on the warm side (in winter) of all exterior floors, walls and ceilings, and a ground cover is installed in the crawl space for both new and existing buildings where insulation is installed. The plans /specs show compliance in the following locations: ❑ Exception. All new or altered building envelope components do not comply with the vapor retarder requirements of the code, but qualify for an exception. Note applicable exception. Section 1312.1.4 Exception 1 ❑ 20 Portions of the building that comply Climate 6. Climate Zones Zones ❑ Zone 1 - A building site is in Climate Zone 1 if its elevation is less than 3000 feet above sea level and it is in one of the following counties: Benton, Columbia, Clackamas, Clatsop, Coos, Curry, Douglas, Jackson, Josephine, Lane, Lincoln, Linn, Marion, Multnomah, Polk, F Tillamook, Yamhill, or Washington ❑ Zone 2 - Building sites not in Zone 1, or where construction site elevation is 3000 feet or higher in Zone 1, are in Zone 2. 3 -1 Form 4a Project Name: Tigard HS- Business/ Technology Remod Page: 11 SYSTEMS - GENERAL Applicability Plans /Specs Discussion of qualifying Show compliance by including a drawing sheet, detail exceptions on page 4 -14 number, specification section and subparagraph 1. Applicablity (Section 1317) Is this'form required? ❑ Form Required. Complete form if a new HVAC system is being installed, or components of an existing HVAC system are being replaced (I.e., equipment, controls, ductwork, and insulation.) ❑ Exception. The building or part of the building qualifies for an exception from HVAC code requirements. Applicable code exception is Section 1317.1. Portions of the building that qualify. Area: Exception 1 ❑ 2 ❑ 3 ❑ Area: Exception 1 ❑ 2 ❑ 3 ❑ Area: Exception 1 ❑ 2 ❑ 3 ❑ l] Form Not Required. This project does not contain work required to comply with code. 2. Simple or Complex Systems (Section 1317.9 or 131 - 7.10) ❑ Simple System. Building contains only Simple HVAC System(s). Complete this form (4a) and equipment efficiency worksheets as required. Form 4b is not - required. ❑ Complex System. Project includes a Complex System. Complete this form (4a), form 4b and equipment efficiency,worksheets as required. 3. System and Zone Controls (Section 1317.4.1 and 1317.4.2) El Complies. All new HVAC systems include at least one temperature control device responding to temperatures within the zones ❑ Exception. HVAC system qualifies for an exception from zone control requirements. The applicable code exception is Section 1317.4.2, Exception 1 ❑ 2 ❑ Portions of the building that qualify The plans /specs show compliance in the following locations: 4. Control Capabilities (Sec. 1317.4.2.1) ❑ Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1317.4.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. ❑ Exception. The building qualifies for an exception to the deadband requirements. The applicable code exception is Section 1317.4.2.1 Exception 1 ❑ 2 ❑ Portions of the building that qualify: The plans /specs show compliance in the following locations: 4 -1 7104a5- HVAC2004 Forms xis March 1, 2004 Form ' Project Name Tigard HS- Business/ Technology Remodel Page 1 LIGHTING - GENERAL 1. Interior Exceptions (Section 1313.1) Exceptions ❑ No Interior Lighting. The building plans and specifications do not call for new or altered interior lighting Skip to item 5, Exterior building Lighting - General, below Discussion of qualifying exceptions in instructions ❑ Exceptions. 1 The building or part of the building qualifies for an exception from code lighting requirements Applicable code exception is number 2 Lighting equipment that qualifies for an exception - in addition to general lighting and is separately controlled. Applicable code exception is number Areas of the building and equipment that qualify for any exceptions Plans /Specs Show compliance by including 2. Local Shut - off controls (Section 1313.3.1.1) a drawing sheet, detail number, ❑ Complies At least one local shut -off lighting control for every 2,000 square feet of and /or specification section and subparagraph lighted floor area and for all spaces enclosed by walls or ceiling height partitions This control(s) is detailed in the building plans on drawing number E2.11 ❑ Exception. The building or part of the building qualifies for an exception. Applicable code exception is Section 1313 3 1 1, Exception. Portions of the building that qualify 3. Automatic Shutoff Controls (Section 1313.3.1.2) ❑ Not Applicable. Office floor area is not over 2,000 square feet of contiguous office floor area or permitted space'is not over 5,000 square feet No offices less than 300 square feet, meeting or conference rooms, or school classrooms ▪ Complies All interior lighting systems are equipped with a separate automatic control to shut off the lighting during unoccupied periods Offices less than 300 square feet, meeting and conference rooms, and school classrooms shall be equipped with occupancy sensors that comply with Section 1313.3 1.2 1 Compliance details in plans /specs' SHEET E2.11 - SPEC SECTION 16900 ❑ Exception. The building or part of the building qualifies for an exception The applicable code exception is Section 1313.3 1,2, Exception Portions of the building that qualify 4. Daylighting - Controls (1313.3.1.3) ❑ No classrooms or atriums with skylights or window to wall ratio greater than 50%. O Complies. All classrooms and atriums with window to wall ratio greater than 50% and /or Exterior skylights are equipped with automatic daylight sensing controls, as required by Section Building 1313 3 1 3 1 and Section 1313.3.1.3.2 The daylight sensors specified comply with Lighting Section 1313 3 1 3 3. is lighting directed to illuminate the exterior Compliance details in plans /specs: SHEET E2.11 of the building and adjacent walkways and loading areas with or without canopies 5. Exterior Lighting (Section 1313.5) O Complies The plans do not call for incandescent or mercury vapor lamps for use on building exterior. Clock ❑ Exception. The building plans indicate luminaires with incandescent or mercury vapor Switches shall lamps, but they are specified for use in or around swimming pools, water features, or other be astronomic locations subject to the requirements of Article 680 of the 2002 National Electrical Code (seasonal correcting) type with separate programs for each day of the week and shall 6. Exterior and Canopy Lighting Controls (Section 1313.3.2) store maintanergyto O Com lies. The building plans and specifications include photoelectric and /or clock maintain timekeeping p g p p p during power outages switches on all exterior lighting systems which are designed and programmed to extinguish lights when daylight is present, as required by Section 1313 3 2 p 7. Interior Connected Lighting Power (Section 1313.4) � YES Complies The interior lighting power does not exceed the interior power allowance established in either the Tenant Space Method (Form 5b) or the Space -by -Space Method (Form 5c) r• Tenant Space Method (Form 5b) r Space -by -Space Method (Form 5c) 5 -1 - - - LlghtingForms040104 xis Form 5b , ' Project Name Tigard HS- Business/ Technology Remodel Page 2 INTERIOR LIGHTING POWER - Tenant Space Method Lighting (a) (b) (c) (d) 'Budget Tenant or Building Type Floor Area (sq ft) Occupancy/ (Table -13G) Max Power Use Types Lighting Power See instructions for Density (W /ft Budget (W ) tlescnption of S chool /University occupancy types 15,890 1 1 17,479 Lighting 1 Total Interior Lighting Power Budget (Watts) for Building. 17,479 Power Budget 2 Total length of track lighting (ft) 3 Line 2 multiplied by 37 5 Watts /ft Track Lighting 4 Total amperage of circuit breaker(s) serving track lighting (amps) - Power 5 Voltage of circuit breaker serving track lighting (volts) - 6 Maximum wattage of track lighting (multiply line 4 by line 5) 7 Track Lighting Power (lesser value of line 3 or line 6) Building's 8 Track Lighting Power (line 7) Lighting 9 Total Interior Lighting Power from Worksheet 5b -1 (Sum of Column (m)) + 16,474 Power 10 Total Adjusted Lighting Power (line 8 + line 9) = 16,474 11 Does design meet budget? Line 10 must be no greater than line 1 YES 5 -2 LightingForms040104 xls Worksheet 5a Project Name Tigard HS- Business/ Technolo! Page' 3 LIGHTING SCHEDULE (a) (b) (c)' (d) (e) (f) Lum Luminaire Lamp Ballasts Luminaire Is Luminaire ID I Power From Type Description No Description No Description (watts) Table 5c A Fluorescent T8 - 4 foot 3 -F32T8 ELECT NO 93W 3 F32T8 1 Electronic Normal Output. RS 93 YES Al Fluorescent T8 - 4 foot =; 3 -F32T8 -ELECT NO -93W 3 F32T8 1 Electronic Normal Output. RS 93 YES C1 Fluorescent T8 - 4 foot 3 -F32T8 -ELECT NO -93W A 3 F32T8 1 Electronic Normal Output RS 93 YES C2 Fluorescent T8 4 foot,, 2-F32T8-ELECT NO 62W i 2 F32T8 1 Electronic Normal Output RS 62 YES F Fluorescent T8 - 4 foot 2 -F32T8 -ELECT NO -62W id. 2 F32T8 1 Electronic Normal Output. RS 62 YES G Fluorescent T8 - 4 foot 3 -F32T8 -ELECT NO -93W , 3 F32T8 1 Electronic Normal.Output RS 93 YES G1 Fluorescent T8 - 4 foot 3 -F32T8 -ELECT NO -93W y 3 F32T8 1 Electronic Normal Output RS 93 YES H Compact Fluorescent Triple , 1- CFTR32WGX24q -3- ELECT -35W 1 CFTR32WGX24q -3 1 Electronic 35 YES — J Fluorescent T8 - 4 foot 1 -F32T8 -ELECT NO-31W 1 F32T8 0 5 Electronic Normal Output RS 31 YES j 4 A 7 A -Z _i - A I{ A 7. LightingForms040104 xls Al • i Worksheet 5b - PFoject Name Tigard HS- Business/ Technology Remodel Page I 4 1 INTERIOR LIGHTING POWER I Space -by -Space Method Only Skip to column (f) if using the Tenant Space Method (f) (a) (b) (c) (d) (e) Lum ID (g) (h) (I) (I) (k) from Quantity of Room ID (do Space Type Space Lighting Power Worksheet Luminaires (or Luminaire Lighting Room not leave any ,Area (Table 13 -H) Type Budget 5a Column lineal ft for track Power Exempt Power Total Ltg blanks) (ft') (enter space type only once per room) LPD (b) x (d) ( lighting) (Watts) Fixtures (g) x (h) Power Each room must -- -- A 'a 76 93 ❑ 7,068 - be identified -- -- Al J 21 93 ❑ 1,953 -- Describe luminaires for -- -- Cl J 41 93 ❑ 3,813 — each individual -- -- C2 A 9 62 ❑ 558 — room in plans -- -- F A 1 62 ❑ 62 -- -- -- G ' -I 26 93 ❑ 2,418 -- -- -- 01 2 93 ❑ 186 — -- -- H 11 35 El 385 -- -- -- J 1 31 ❑ 31 -- For iracklighting enter lineal feet In column -- -- — - ❑ _ -- column (g) A ]] ❑ -- Column (k), enter sum J ❑ of column onfor each __ __ _ _ __ room only once at first ❑ entry for the room See __ -- J - ❑ - -- example In Instructions �{ J - ❑ _ __ __ __ V_1 - ❑ _ __ H - ❑ _ __ __ __ _1 - ❑ _ __ __ -- -_31 - ❑ - __ _ F I - ❑ - — __ __ _1 _ ❑ - __ H _ ❑ _ __ -- -- & ❑ __ -- J - ❑ - __ __ _- - _ ❑ - __ __ _- .d, - ❑ - -_ A - ❑ - __ J - ❑ - __ __ __ _1 - ❑ - __ Other Pages - Worksheet 5b -1 Total Budget - Wksht 5b -1 Total Lighting Power (excluding exempt/track fixtures) 16,474 Lot the additional worksheets necessary to catalog all luminaires In building Total Number of Additional Worksheet 5b I 0 z d WI) n Worksheet Number Lighimg Power Budget Space -by- Proposed Bwdmg Lighting Power Area Sqft (not required for Space only (Total of column (e)) (Total of column (k), excluding Tenant Method) exemotftrack) 5b -1 - 16,474 - 5b-2 5b -3 Sum of additional 5b worksheets \ :r� >o� Total Budget (of all worksheets) - 16,474 - 5 -5 LightingForms040104 xis