Tigard Tualatin School District
Stephen Poage : '
• 6960 SW Sandburg Rd.
Tigard, OR .
RE: TIGARD HIGH SCHOOL GRITS LOCKER ROOM /CE 2 TRANSETION ROOM '
' Project Information ' .
Building Permit: BUP2005 -00095 : Occupancy Type: E
Tenant Name: Tigard High School Construction Type: V -B
Address: 9000 SW Duram Rd. Occupant Load: 273 +/-
Area: 9,178 Sq Ft : Stories: • • 2
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition;
and the Tualatin Valley Fire & Rescue Fire & Life Safety Requirements'
' for Fire Department Access and Water Supplies (Based on the 2003 International Fire Code as amended
by TVF&R). The submitted plans are approved subject to the following conditions.
1. Special Inspection is required for all welding, bolting, adhesive anchors and anchor bolts,
concrete and reinforcing steel and structural masonry as per sec.1704, 1705, 1707 and 1708.
The special inspection agency of record shall furnish inspection reports to the Engineer of Record,
Nishkian Dean, the General Contractor, and the City of Tigard, Building Division, attention
Hap Watkins. All discrepancies shall be brought to the immediate attention of the general
contractor for correction. The special inspector shall submit a final signed report stating whether
the work requiring special inspection was, to the best of the inspector's knowledge, in
conformance with the approved plans and 'specifications and the applicable workmanship
provisions of the code. 1704 OSSC
2. All exit and exit access doors shall not be provided with a latch or lock unless it is panic hardware.
Section 1008.1.8 OSSC
3. All exit doors shall be openable from the inside without the use of a key or any special knowledge or
effort. 1008.1.8 OSSC
4. The means of egress width shall not be less than required by this section (Sec. 1005.1). The total width
of means of egress in inches shall not be less than 72 inches in Group E with a corridor having a
required capacity of 100 or more.
5. Exit signs shall be illuminated at all times and shall be provided with a second source of power that
will provide 1 '/ hours of illumination in case of primary power loss. 1006.3 OSSC FYI Additional
exit signs may be required by the city field inspector to clearly indicate the path of egress.
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
r'' rs ,Ji i
iv �„
s r Y J :
h '
€¢ 4 „
: :4,
}
�`A ■ � : �.t e. d 4
i "
�'h
j .
:mo `' ;�• '� '� ";'
i ! � f r ,
R
c 1 r "
h'
� '
ga
Lar. •
t y ':
;:fits
i t4'
"I''''' .
t-
4 I
v `
t t`
rv
6. '' The ` means '' o f egr , b ' rovid ed w n'f no
' i ll um ina t i oot les th - 1 foot : " a t t . -
4T
'an - e the• building is occupe d. The means of e ess 'illumination shall be rovided with a second r,.'}
Yom?? :, �.,,, � p
'''''` ower in case of rim M ower: loss.'' 1006:2 OSSC ' L. - " m' ', f`° ',.A
- " I? P GYP ,. ,, ",
'' 7. Deferred submittals ,such as Fire`Alarm' Fire Sprinkler, Truss oist Sho Drawin 'etc will be char " '
P J P' g
• ' , ,,. a deferred submittal fee based on the valuation of the portion of the work being deferred. The , ,
' minimuni.fee shall be $200.00. ' .
8. Am erican with Disabilities Act (ADA):' It shall be the responsibility of the Architect, Engineer, ` „' ,
Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the '
structure. The City of Tigard reviews the plans and inspects the structure only for compliance with
_ Chapter 11 of the OSSC, which may not include all o the requirements• of the ADA.
9. Live Loads Posted: The live loads for which each floor has been designed to exceed 50 psf shall be _
' ' conspicuously posted by the 'owner in that part of each story in which they apply,'using durable metal `” , .
signs, and it shall be unlawful to remove or deface such notices. The occupant of the building shall be
responsible for keeping the actual load below the, allowable limits. 1603.3 OSSC
. . _ , ., . . , •
10. Safety glazing including but not limited to: the' following Iocations: Each unit of glazing shall be
permanently identified by the manufacturer. '2406 OSSC. Some of these locations are as follows: , ,
a. Glazing in ingress and means of egress doors. `
b. Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical
edge is within a 24" arc of the door in ,a closed position and whose bottom edge is less than
60" above the floor or walking surface except when there is an intervening wall or other
permanent barrier between the door and the glazing. .
c. Glazing that meets all the following conditions: , In lieu of safety glazing, protective bar (1 ' /2"
height minimum) may be installed on the accessible side(s) of the glazing 36" ± 2" above the
floor. The bar shall be capable of withstanding a horizontal load of 50 plf without contacting
the glass. Sec. 308.4 '
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained
on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of
construction. 106.3.1 OSSC
Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official
has issued a certificate of occupancy 110.1 OSSC ' , '
Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such
a position as to be plainly visible and Iegible from the street or road fronting the property.
When submitting revised drawings or additional information, please attach a copy of the enclosed City of
Tigard, Letter of Transmittal.- The letter of transmittal assists the City of Tigard in tracking and
processing the documents. .
Respectfull /
Val enze , enior Plans Examiner