Loading...
Plans 76Z5 5 w' Pw R4 SW Church of Christ Residential/Dwelling: 4/12/04 mcUlndustrial: x 8636 O FE Approximate C7' of Construction Comeria : EECvTR, ICAI.�TI_Q__N_ �2 C Rt o C I J b O ( i pproiamate o' of Illuminated Lot: CCB# 138608 Proposed Voltage 0 to 0: 208 Phase: 3 LIGHTING WattsIO' Continuous Calculated Square Feet Specific Space Usage Race 2toa1all Duey (YeslNo Load rya► 6802 Auditorium 1 Yes 8503 1834 Core/Hall/Storage 0.5 Yes 1146 Yes Yes Yes Yes Yes Yes Yes Lighting Load Demand Factor »[ 0 TOTAL LIGHTING LOAD » 9649 VA Receptacle Load Enter KNOWN quantity Here >1 241 or ° X ° Here >I 4320 Sign Circuit: 1200 CD ` Comtinuous Calculated Specific Receptacle Usage a Watts Duty (Yes/No) Load WA) Receptacle Load Demand Factor » 0 TOTAL RECEPTACLE LOAD » 5520 VA Motor /Fixed Equipment Load Continuous 8 . Duty(Yes/No) Calculated Equipment Specific Usage a Watts Ho,e �" Load (VA) AHUO1 208 71.2 3 25621 yes 32026 AHUO2 208 71.2 3 25621 25621 AHUO3 208 22.5 3 8096 8096 EWH01 & EWH02 120 12.5 1 1500 1500 EWHO3 120 6.2 1 744 744 WH01 208 24 1 4992 4992 Baptistry Pump 120 15 1 1800 1800 Baptistry Water Heater 208 26.5 1 5512 5512 Motor /Fixed Equipment Load Demand Factor »I 0 TOTAL MOTOR/FIXED EQUIPMENT LOAD » 80291 VA Calculated Service Size » 95460 VA Calculated Service Size » 265 Amps Project Name: SW Church of Christ LIGHTING SCHEDULE +` „, :.'- t -,, .,,4P..,,,,, ,,..' a ,, "_. 4.. "iL„.- - ;;- ,..:--,s7 m' ........ 1• k_:1".. ..w- :?...i,71....,.., it :!,e ,s. -,7- za '271es7 (a) (b) (c) (d) (e) (f) Luminaire Fixture Lamp Ballast Luminaire Tab ID Description Power 5b No. Description No. Description ( "x') A NOT USED AE NOT USED Stem Mount, 7" Open Cylinder, 150 watt PAR38 Lithonia _B. CC7B_AR or EQUAL_ 1 100 Watt, PAR38 N/A 100 Stem Mount, 7" Open Cylinder, 150 watt PAR38 Lithonia B1 CC7B AR or EQUAL 1 250 Watt, PAR38 N/A 250 Recessed Open Downlight C Lithonia AF 1 32TRT 8AR or EQUAL 1 32TRT 1 Electronic - 120 v 34 Recessed Open Downlight CE Lithonia AF 1 32TRT 8AR or EQUAL (EMERGENCY BALLAST) 1 32TRT 1 Electronic - 120 v 34 Commercial Strip Light (Indirect) Lithonia D TSS 232 120 GEB or EQUAL 4 F32T8CW I Electronic -120 v 114 Commercial Strip Light (Indirect) Lithonia — DE TSS 2 32 120 GEB or EQUAL (EMERGENCY BALLAST) 4 F32T8CW 1 Electronic -120 v 114 Surface Wrap 1x4 LUhonia LB E 232 120 GEB or EQUAL 2 F32T8CW 1 Electronic -120 v 62 Compact Fluorescent Drum Enertom F 1036E -L or EQUAL 2 18DTT I Electronic - 120 v 32 Stem Mount, 8" Open Cylinder, 1) 32TRT Lithonia G CFV9 1/32TRT AR or EQUAL 1 32TRT 1 Electronic -120 v 34 H Track light - TBD 12 100 Watt, "A” N/A 100 Emergency Exit Sign Lithonia X LQM S 1 R 120/277 EL Nor EQUAL X LED N/A 1.2 Project Name: SW Church of Christ INTERIOR LIGHTING POWER i ew'3.tyF -m_, . z'3,.. r. f i v- q.r,;.a; r:, ve :.',z 7 ovix;''v,s j?„'" F.+L�'„°.3+`s.T»�',,,; +s t.�'r,Sr;„ , t: 'y N +. - c.T'. V " : : ::GZ 2irj' „MC', _o1 (a) (b) (c) (d) (e) (f) Room or Lighting Sheet No. Room or Plans Designation Luminaire ID Quantity of Luminaire Power Luminaires Power (d) x (e) E01 ' Auditorium (Indirect) D /DE 34 114 Watts 3876 E01 Auditorium (Pendant) B 32 100 Watts 3200 E01 Auditorium (Pendant) B1 6 250 Watts 1500 E01 Baptistry C 2 34 Watts 68 E01 Entry Vestibules Tatteior Lighting) G 8 34 Watts N/A E01 Exit Indication X 7 1.2 Watts 8.4 E01 Exterior Walkways (Exterior Lighting) F 16 34 Watts N/A E01 Hallways E 2 62 Watts 124 E01 Lobby C /CE 10 34 Watts 340 E01 Restrooms/Dressing Rooms E 2 62 Watts 124 E01 Storage E 3 62 Watts 186 E01 Training Room C 2 34 Watts 68 E01 Auditorium (Feature Lighting) H 12 100 Watts 1200 Watts Watts Watts Watts Watts Watts Watts Watts Page Total. Total the amounts in Coulmn (f) 10694.4 Project Name: SW Church of Christ INTERIOR LIGHTING PLAN - Occupancy Method Retail or (a) (b) (c) (d) (e) (f) (9) Merchandise Maximum Power Lighting Lighting Group Area Floor Area (ft Allowance Power Budget Power (W/ft ((c -d) x e) +f (Group M) If area is less than 2,000 ft enter area in (c), this row - 3.4 - If area is between 2,000 and 6,000 ft M enter area in (c), this row 2,000 2.5 6,800 If area exceeds 6,000 ft enter area in (c), this row 6,000 1.7 16,800 (a) (b) (c) (d) (e) a. ` (f)i „ (g) :4.,:, Uses Other Maximum Power k . M ,,, y L Than Group Occupancy Use Ceiling Floor Allowance .' , Power Budget Group M Height Area (ft (W /ft (d) x (e) Under 15 feet 1834 1.1 °ups 2017 A Auditorium 15 feet or more 6802 1.4 ,Nren k .1 9523 Under 15 feet ` 4s ;;` 15 feet or more r'.w; ,. • Under 15 feet ; :„ "°; 4 15 feet or more , .; - =.; }a Under 15 feet . iWirli —I 15 feet or more , >7WIX 5 1. Total Interior Lighting Power Budget (Watts). Add amounts in column (g). 11540 2. Sum the total(s) from Worksheet 5b. 10694.4 3. Total linear feet of track lighting I 0 f �w;, ' arfffel 4. Multiply line 3 by 50 0 5. Total Interior Lighting Power. Add lines 2 and 4. 10694.4 6. Total Control Credit from Worksheet 5c. 7. Total adjusted Lighting Power(VV). Subtract line 6 from line 5. 10694.4 8. Does design meet the budget? Enter "Y" if line 7 is less than line 1, otherwise redesign. YES Form 5a Project Name: SW Church of Christ LIGHTING - GENERAL 1. Interior Exceptions (Section 1316.1) ❑ No interior Lighting. The building plans do not call for new or altered interior lighting. Skip to Exceptions Item 4, Exterior Building Lighing - General, below. See a discussion of ❑ Exception. The building or part of the building qualifies for an exception from code lighting wring es requirements. The applicable code exception is Section , Exception . Portions on Papas 5-7. of the building which qualify: 2. Local Shut -off Controls (Section 1316.1.2.1,1) E3 Complies. At least one local shut -off control for every 2,000 square feet of lighted floor area Exceptions and for all spaces enclosed by walls or ceiling height partitions. This control(s) is detailed in see a discussion or Construction Drawings qualifying exceptions ❑ Exception. The building or part of the building qualifies for an exception from code exception on Papas 15-5.. is Section 1316.1.2.1,1, Exception . Portions of the building which qualify: 3. Local Shut -off Controls (Section 1316.1.2.1,2) ❑ Not an Office Occupancy over 2,000 square feet. Exceptions © Complies. All interior lighting systems are equipped with a separate automatic control to shut off See a discussion of the lighting and local override switching. These control(s) are detailed in the building plans. qualifying exceptions an Pages ss. ❑ Exception. The building or part of the building qualifies for an exception. The applicable code exception is Section 1316.1.2.1,2, Exception . Portions of the building which qualify: 4. Exterior Building Lighting - General ❑ No Exterior Building Lighting. Skip the rest of this form. 2 Complies. Complete items 5 and 6 below 5. Exterior Building Lighting Controls (Section 1316.1.2.2) © Complies. The building plans require that all exterior building lighting is equipped with automatic controls as described in Section 1316.t2.2. These controls are detailed in the building plans on drawing detail number E00 ❑ Exception. The exterior building lighting is intended for 24 -hour continuous use. 6. Exterior Building Lighting Controls (Section 1316.1.2.2) © Complies. The plans do not call for incandescent lamps greater than 10 watts for use in exterior building lighting. ❑ Exception. The building plans indicate luminaires with incandescent lamps greater than 10 watts, but they are 5 percent or less of the total installed exterior lamps. Form 2a Project Name: SW Church of Christ SUMMARY '�. yt " " .x. Y .. a. u�° ._ =� _,c >'_ .. . _< 7 s 4a ._. �d ;'! ;r *? i :ru3..� .ter 3 U e : w• °w_ � 5'. Zat g h �Z o 1 Project Name: SW Church of Christ 2 Address: 9725 SW Durham Road 3 City/Town: Tigard 4 Building Area (ft2): 8636 5 County: Washington 6 Number Of Floors: 1 }.;x' �+`�i. 'r•?' fit r u F+�a. �� � i t t'e'a y'"3:^"�13 v - r . � � .: .� a � � c +7•F '� �"""' ,� z " x » � � '�,.£ �; yr mss` 7°ai;� x••r --" �-.r .�^ tZ�*:. r i. F.r`.^ k c�`5':.:..�' ."L..:�. }'wae�3 _ � d';k.:.a+�.+. � zae....iw.xra�' ��w.�,S. .zwr.Ys. �� .ix...a ��.: Y,.: y.�:�'� -r ��. ` �'.. < t , � �b°'#P 7��e�*. �c�a X 4,z � Chapter Type ID Description Attached Building Form 3a Envelope -- General ATTACHED Envelope 3b Prescriptive Path - Zone 1 FORMS AND 3c Prescriptive Path - Zone 2 WORKSHEETS 3d Simplified Trade -off Worksheet 3a Wall U- Valves 3b Roof U- Valves 3c Floor U- Valves Systems Form 4a Systems - General 4b Complex Systems Worksheet 4a Unitary Air Conditioner — Air Cooled 4b Unitary Air Conditioner -- Water Cooled 4c Unitary Heat Pump -- Air Cooled 4d Unitary Heat Pump — Water Cooled 4e Unitary AC & Heat Pump — Evaporatively Cooled 4f Packaged Terminal Unit -- Air Cooled 4g Packaged Terminal Heat Pump -- Air Cooled 4h Water Chilling Packages -- Water & Air Cooled 4i Boilers — Gas -Fired and Oil Fired 4j Furnaces & Unit Heaters -- Gas -Fired and Oil Fired Lighting Form 5a Lighting -- General • 5b Interior Lighting Power -- Occupancy • 5c Interior Lighting Power -- Space Worksheet 5a Lighting Schedule • 5b Interior Lighting Power • 5c Interior Control Credits a, r..,• a .v t y , r 't- c x A x3h �J �, .x .,:. ._.3 si°•,.:: ». �:....t,,a._.?i'c.,..s :...,ls,.:...��t, _ "'; �. '4 y�ri^�.r.,.v.2�:`. fia ..,�•cfit:'��...ai�: �.+e. � �'rf k,d'S'vie�*"i� U:�ty'�1 `f���F:(ttu, ?���,;:', APPLICANT 7 Name: Andy Lorenz 10 Telephone: (503) 614 -0400 8 Company: Lorenz Electrical Cons . Date: 12 -Apr -04 9 Signature: '/