Loading...
Correspondence July 5, 2005 +` CITY OF TIGARD OR EGON Paul Franks Architectur Paul Franks 3805 108' Ave. NE Suite 222 Bellevue, WA 98004 RE: OAK TREE I APARTMENTS - RESTROOM Project Information Building Permit: BUP2005 -00270 Occupancy Type: R -2 Tenant Name: Oak Tree I Apartments Construction Type: 5 -B Address: 10966 SW Durham Occupant Load: NA Area: 6,083 Sq Ft Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and 2003 International Fire Code as amended by TVF &R. The submitted plans are approved subject to the following conditions. GENERAL 1. All exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. 1008.1.8 OSSC 2. Floor drains shall not be located within the clear floor space at a lavatory, water closet, urinal, or bathtub or shower. Floors shall not slope in excess of 1 unit vertical in 50 units horizontal (2- percent slope). Floor drains shall comply with Section 1109.4.5 and be without abrupt changes of level. Exception: Floor drains may be located within a clear floor space at a fixture provided the openings in the drain cover shall not exceed %2 inch (12.7 mm) in any direction and the drain cover shall be no more than 1/8 inch (3.2 mm) below the level of the surrounding finishedfloor surface. 3. Faucets and other controls shall be located on the same wall as the shower spray unit, and shall be installed not less than 38 inches (965 mm) or more than 48 inches (1219 mm) above the shower floor and shall comply with Section 1109.3.2.. In addition: OSSC 1109.10.10.5 4. For transfer shower stalls, the controls shall be located on the wall opposite the shower seat. The controls shall be located within 18 inches (457 mm) of the open side of the shower stall [see ADAAG Figure 37(a)]. A shower spray unit with a hose at least 60 inches (1524 mm) long that can be used as a fixed shower head or as a hand —held shower shall be provided. The hand held portion of the shower unit shall be mounted within the reach ranges of Section 1109.2.3.5 for forward approaches and Section 1109.2.3.6 for side approaches. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 5. American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC, which may not include all of the requirements of the ADA. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy 110.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, f h . 2 € al Henzel, Senior Plans Examiner