Permit ' i s C I tY OF TIGARD MECHANICAL PERMIT - COMMUNITY DEVELOPMENT PERMIT #: MEC2008 -00160 TIGARD 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 DATE ISSUED: 3/31/2008 PARCEL: 2S 110DC - 02300 SITE ADDRESS: 11535 SW DURHAM RD C -4 ZONING: C -G SUBDIVISION: WILLOWBROOK BUSINESS PARK LOT: JURISDICTION: TIG PROJECT: GENTOG Project Description: Install (8) fire dampers. Project Value: $1,716 CLASS OF WORK: ALT FLOOR FURN: EVAP COOLERS: TYPE OF USE: COM UNIT HEATERS: VENT FANS: OCCUPANCY GRP: A3 VENTS W/O APPL: VENT SYSTEMS: STORIES: 1 BOILERS /COMPRESSORS HOODS: FUEL TYPES 0 - 3 HP: DOMES. INCIN: 3 - 15 HP: COMML. INCIN: MAX INPUT: BTU 15 - 30 HP: FIRE DAMPERS ?: Y 30 - 50 HP: REPAIR UNITS: GAS PRESSURE: 50 + HP: WOODSTOVES: FURN < 100K BTU: AIR HANDLING UNITS CLO DRYERS: FURN > =100K BTU: <= 10000 cfm: OTHER UNITS: 8 > 10000 cfm: GAS OUTLETS: Owner: FEES HIP WILLOWBROOK LLC Description Date Amount PO BOX 2708 PORTLAND, OR 97208 [MECH] Permit Fee 3/31/200E $72.50 [MECPLN] Plan Rev 3/31/200E $18.13 [TAX] 12% State Surch 3/31/200E $8.70 Phone: Total $99.33 Contractor: REITMEIER MECHANICAL INC 19570 SW 90TH CT TUALATIN, OR 97062 REQUIRED ITEMS AND REPORTS Contact #: PRI 503- 603 -0205 FAX 503 -603 -0150 Reg #: LIC 153770 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain copies of these rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. Issu By: , , / /1 LL,j% Permittee Signature: (V- 7VAffeetr Call 503.639.4175 by 7:00 a.m. for inspections that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical ?ermit Application • FOR OFFICE USE ONLY City of Tigard Received Date/By: 1 Permit No.: g,e„ ( 900 g ° 13125 SW Hall Blvd., Tigard, OR 97223 Plan Review 111 2 . Phone: 503.639.4171 Fax: 503.598.1960 Date/By: Other Permit: Inspection Line: 503.639.4175 TIGARD Date Ready/By: R2 See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information rn?EINC:Z,;adgSa reo Mechanical permit fees* are based on the value of the work New construction Z Addition/alteration/replacement performed. Indicate the value (rounded to the nearest dollar) of all 0 Demolition 0 Other: mechanical materials, equipment, labor, overhead, and profit. niii ,„ ,„ „ ,„ „ 1 .1 6 it*4kOr*NO El I- and 2-family dwelling Z Commercial/industrial 0 Accessory building For special information use checklist. 0 Multi-family 0 Master builder 0 Other: Description Qty. 1 Ea. Total AND LOCATIO1 MILs1-7,7fi Heating/cooling Air conditioning or heat pump Job site address: 14-545 Durham Rd. (requires site plan showing placement) 14.00 City/State/ZIP: Tigard, OR 97223 Furnace 100,000 BTU (ducts/vents) 14.00 Furnace 100,000+ BTU (ducts/vents) 17.90 Suite/bldg./apt. no.: Q6 c,9 Project name: Wiliforbroulvfiuildiug Gas heat pump 14.00 Cross street/directions to job site: OTE) 6 Duct work 10.00 Hydronic hot water system 14.00 Residential boiler (radiator or hydronic) 14.00 Unit heaters (fuel-type, not electric), in-wall, in-duct, suspended, etc. 14.00 Flue/vent for any of above 6.80 Subdivision: Lot no.: Other: _ 10.00 Tax map/parcel no.: Other fuel appliances oat-iiii8EifiiifoislOi*OW:AvPlionetcot:41: Water heater 10.00 Gas fireplace 10.00 Install 8 fire dampers. Flue vent for water heater or gas fireplace 10.00 Log lighter (gas) 10.00 Wood/pellet stove 10.00 Wood fireplace/insert 10.00 , Au,, , 74/4-r.r,m , Chimney/liner/flue/vent 10.00 1.1,N,040a, AMPENIT:11:1:00,tailfit::„gal Other: 10.00 Name: Willowbrook Maint Environmental exhaust and ventilation Range hood/other kitchen Address: 11545 Sw Durham Rd equipment 10.00 City/State/ZIP: Tigard, OR 97223 Clothes dryer exhaust 10.00 Single-duct exhaust (bathrooms, Phone: ( ) Fax: ( ) toilet compartments, utility moms) 6.80 jj AttickrawisPace fans 10.00 Other: 10.00 Business name: Reitmeier Mechanical Fuel piping Contact name: Matt Rogers $5.40 for first four; $1.00 for each additional Furnace, etc. Address: Gas heat pump City/State/ZIP: Wall/suspended/unit heater Phone: (503) 686-4462 Fax: : (503) 783-5789 Water heater Fireplace E-mail: matt.rogers@reitmeiermechanical.com Range Balbecue Clothes dryer (gas) Business name: Reitmeier Mechanical Other Address: 19570 SW 90 Court 4AefrAleZirilifcOVFtigf;'ASIM City/State/ZIP: Tualatin, Oregon 97062 Subtotal Minimum permit fee ($72.50) Phone: (503) 603-0205 Fax: (503) 603-0150 Plan review (25% of permit fee) CCB lie.: 153770 State surcharge (12% of permit fee) ( . 7 , - TOTAL PERMIT FEE 7 Authorized signature: ;ziledifi.“7- This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: Matt Rogers Date: 3/31/08 Fee methodology set by Tri-County Building Industry Service Board I: \ Building \Permits \MEC-PermitApp.doc 01/19/07 440-4617T (I 1/02/COM/WEB) CITY OF TIGARD BUILDING DIVISION PERMIT #: MEC2008-00160 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 3331/200) Phone: (503) 639-4171 Requests (24 Hrs.): (503) 639 -4175 `__.. INSPECTION WORKSHEET FOR DATE: 4/15/2008 TIME: 7:02AM PAGE: 34 SITE ADDRESS: 11535 SW DURHAM RD C - 4 CLASS OF WORK: SUBDIVISION: WWLLOVNBROOK BUSINESS PARK LOT #: TYPE OF USE: PROJECT NAME: t ENTOC DESCRIPTION: Install (8) fire dampers. Project Value: $1,716 OWNER: HIP WILLOW ROOK LLC, PHONE #: CONTRACTOR: REITMEIER MECHANICAL INC PHONE #: 503- 603 -0206 Inspection Request Scheduled For: Date: 4/15/2008 Pour Time: q 4 6 Code # Inspection Description Confirm # Contact # Mes ge 689 Mechanical final 068376 -02 503.639 -2600 V Correction Comments /tructions: - \/■5;% \IA-C (%-tA L._ t • SS ❑ PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS n FAIL CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: \ C-1 v Ph Date: 4 /1 /- one #: (503) 718- —/ CITY OF TIGARD BUILDING DIVISION PERMIT #: MEC2009-00160 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 3/31/20013 Phone: (503) 639 -4171 H" lyi Inspection Requests (24 Hrs.): (503) 639 -4175 • INSPECTION WORKSHEET FOR DATE: 4015/20013 IME: 7:02AM PAGE: 35 SITE ADDRESS: 1153' SW DURHAM RD C-4 CLASS OF WORK: SUBDIVISION: WiLLOWBROOK BUSINESS PARK LOT #: TYPE OF USE: PROJECT NAME: GENTOG DESCRIPTION: In�' 1 Project Value: $1,716 OWNER: HIP WILLOWBROOK LLC, PHONE #: CONTRACTOR: REITMEIER MECHANICAL INC PHONE #: 503 - 603 --0205 Inspection Request Scheduled For: Date: 4/15/2008 Pour Time: Code # Inspection Description Confirm # Contact # Message 630 Fire damper 068376.01 503-639-2600 N Corrections /Comments/ Instructions: -- e_F 14 'Y a- _ Lam, . A---- I ❑ PARTIAL APPROVAL ❑ CANCEL n NO ACCESS I FAIL n CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: 1 " '�; (5—Z___ - Date: Vj ‘ CA Phone #: (503) 718- Z�Z"/