Loading...
Plans P Saoo�- 000g August 4, 2006 • �3 L 5 1 "j u,C4VV/'WWn M . Sprrink 41 a • MICROFAST® AND TECHNICAL DATA . MicrofastHP® QUICK RESPONSE • -r. , PENDENT SPRINKLERS 1. PRODUCT NAME MICROFAST AND MicrofastHP° QUICK RESPONSE PENDENT SPRINKLERS • tThe Sprinkler Identification Number (SIN) is stamped on the sprinkler deflector a 2. MANUFACTURER THE VIKING CORPORATION CEI V ED 210 N Industrial Park Road Hastings, Michigan 49058, U.S A. MAR 3 1 2009 c 7 Telephone (269) 945 -9501 Technical Services: (877) 384 -5464 CITY OFTIGARD Fax (269) 945 -9599 BUILDING DIVISION e mail techsvcs @vikingcorp.com 3. PRODUCT DESCRIPTION Viking Microfast and MicrofastHP Quick Response Pendent Sprinklers are small thermosensitive glass bulb spray sprinklers available in various finishes, temperature ratings, and orifice sizes to meet design requirements The special Poly finishes and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these finishes have been investigated for installation in corrosive atmospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart (Note' FM Global has no approval classification for Teflon and Poly finishes as corrosion resistant ) The pip cap and sealing assembly of the sprinkler are held in place by the glass bulb operating element. During fire con- ditions, the heat - sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire 4. TECHNICAL DATA LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 Refer the Approval Chart on page 41 c and Design Criteria on page 41 d for cULus and FM approval requirements that must be followed. CHARACTERISTICS • Minimum Operating Pressure. 7 psi (0,5 bar) • Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for use with water working pressures ranging from the minimum 7 psi (0,5 bar) up to 250 psi (17,2 bar) for high - pressure systems. High - pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. • Factory tested hydrostatically to 500 psi (34,5 bar) • Testing U S A Patent No 4,831,870 • Thread size. Refer to the Approval Chart • Nominal K- Factor. Refer to the Approval Chart • Glass -bulb fluid temperature rated to -65 °F ( -55 °C) • Overall Length Refer to the Approval Chart MATERIALS Frame Casting Brass UNS- C84400 Deflector. Brass UNS- C51000 or Copper UNS- C19500 for Sprinklers 06662B, 06666B, 06765B, and 12104. Copper UNS- C19500 for Sprinkler 12282 Brass UNS- C26000 for all other Sprinklers Bushing (for Sprinklers 06718B, 06720B, and 12290) Brass UNS- C36000 Note Units of measure in parentheses may be approximations. Replaces page 41 a -b, dated November 18, 2005 (Reformatted, added Form No F_081296 135 °F temperature rating, and added CE approval for sprinkler 06666B.) Sprinkler 41 b August 4, 2006 JHJFG .. ' MICROFAST® AND MicrofastHP® TECHNICAL. zDATA QUICK RESPONSE PENDENT SPRINKLERS TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES '" k `,- S ^' F3 ` °` ' "c+r' -ai '"N�. 'S� .:air} + .s s+e v.b Hr .i3 h,' aFE' ct' KfFa ia"+ 54 j gads trriWe ature x ,:a . Son kie N�o rt 4 tMa imu� rt nt , Bu lb Classificat!on Tempe tature Rat�rf Derling�Temperature Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome- Enloy ® , White Polyester (White Poly finish for Sprinkler 06662B), Black Polyester (Black Poly finish for Sprinkler 066623), and Black Teflon Corrosion- Resistant Coatings White Polyester (White Poly finish for Sprinkler 06662B only), Black Polyester (Black Poly finish for Sprinkler 06662B), and Black Teflon 1 The sprinkler temperature rating is stamped on the deflector 2 Based on NFPA -13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction Refer to specific installation standards 3 The corrosion - resistant coatings have passed the standard corrosion test required by the approving agencies indicated on page 41 c These tests cannot and do not represent at possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only Note that the spring is exposed on sprinklers with Poly finishes and Teflon coatings. Bulb Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS- C36000 Pip Cap and Insert Assembly. Copper UNS- C11000 and Stainless Steel UNS- S30400 Pip Cap Attachment Brass UNS- C36000 Ejector Spring (for Sprinkler 12104): Stainless Steel For Teflon Coated Sprinklers Belleville Spring- Exposed, Screw - Nickel Plated, Pip Cap- Teflon Coated For Poly Coated Sprinklers: Belleville Spring- Exposed AVAILABLE FINISHES AND TEMPERATURE RATINGS: Refer to Table 1 above. 5. ORDERING INSTRUCTIONS (Also refer to the current Viking price list.) Order Microfast Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to sprinkler base part number Finish Suffix. Brass = A, Chrome - Enloy = F, White Poly Finish = M - /W, Black Poly Finish = M - /B, and Black Teflon = N Temperature Suffix ( °F / °C) 135 °168° =A, 155 ° /68° = B, 175 0 /79 0 = D, 200 ° /93° = E, and 286 = G For example, Sprinkler VK302 with a 1/2" thread, Brass finish and a 155 0 F/68 0 0 temperature rating = Part No. 06662BAB ACCESSORIES (Also refer to the "Sprinkler Accessories" section of the Viking data book ) Sprinkler Wrenches: A. Standard Wrench: Part No 10896W/B (available since 2000) B. Wrench for coated and /or recessed sprinklers Part No 12144W/B ** (available since 2003) NOTE: Recessed pendent sprinklers with protective caps must use wrench 12144W/B. **A 1 /2" ratchet is required (not available from Viking) Sprinkler Cabinets: A. Six -head capacity. Part No. 01724A (available since 1971) B Twelve -head capacity. Part No 01725A (available since 1971) • ' ' ' • SpnnNer41 c August 4, 2006 . . K8|CROFAST® AND � � ^ «» ^ . � ' ^� microfastHP® ^. ' NIKING �U� ��U|��kCRESP0NSE � PENDENT SPRINKLERS Nominal Listings and Approvals Base Part Thread Size Overall Length SIN K-Factor (Refer also to Design Criteria on page 41 d.) . . ^ Standard Orifice 06662B VK302 1/2" 15 mm 5.6 80,6 2'1w 58 1A1x. B1Y A4X, B4Y A1x. B1Y F2 A4X C4X, D4Y C4X, D4Y Large Orifice 06666o VK352 3/4" 20 mm 8 115,2 2-3/8 60 A3X, B3Y A2X, B2Y A3X, B3Y — s412 — 1210* VK352 3/4' 20 mm 8 115.2 2'1w 58 — — — F2 — — — 06765o VK352 1/2" 15 mm 8 115.2 2-3/8 60 A3X, B3Y — A3X, B3Y - — — — omaxo,moe" 067188 VK329 1/2" 15 mm 2 40,3 2'3/16 56 aax, B3Y A2X A3X, B3Y ' — — 06720a vx331 1/2" 15 mm *z 60,5 2-1/4 58 A3X, B3Y — A3X, B3Y 06932B vx331 -- 10 mm 4z 60,5 2-3/8 60 — — — F2 -- F2 Maximum 250 PSI (17,2 bar) WWP Standard Orifice Nominal Listings and Approvals Base Part SIN Thread Size K-Factor Overall Length (Refer Design u,uo,/uon page 41 d.) NPT sap U.S. metric Inches mm cULus FM mYc` VdS LPCB (E 0 12282 vx317 1/2" 15 mm 5 80,6 2'1w 58 A3X, B3Y — A3X — — — — Maximum 250 PSI (n.e bar) xmmp umaxonnoo" 122e0 vx342 1/2" 15 mm 2 40.3 2'3/16 | 56 A3X, B3Y — A3X — — — 1 — Approved Temperature Ratings A 135 ~p(57`C).155 ^ F(68 ^ C). 175 °F (79 °C), Approved Escutcheons 200 °F (93 °C), and 286 °F (141°C) Approved Finishes X Standard surface-mounted escutcheon B 135 ^F<57 ^ C>.155 ^ r(68 ~ c).175 ^ F (79 °C), 1 Bmvn, Chrome-Enloy White Poly Fm/sor, or the Viking Microfast Model F-1 and znn^F(on~C) Black Poly Fmioxr. and Black nefl� Teflon Adjustamesscutchennn C 155 ^F(68 ^C).175 ^ r(79 ^ o).200 ^ F(9 3 `o). 2 Brass and Chrome-En!oy Y Standard surface-mounted eucmm`' anuze6~p(141^c) 3 emno, oxmmnsn|oy White pmvomor eon or the Viking w/cmfast Model D 155 °F (68 ^ o). 175 °F (79 °C), and 200 °F Black Polyester and Black Teflon F-1 Adjustable Escutcheon or re- (93 °C) 4 emaa, cmomo-enmv White Poly Fimoh, cessed with the Viking Micro- E 155 °F (68 ^c). 175 ~r (79 ^c), and 286 ^F and Black Poly Finish matic Model s'1 or E-2 Recessed (141°C) Escutcheon F 155 ^F(68 ^ C) Footnotes 1 Base part number is shown For complete part number, refer 10 Viking's current price schedule 2 Metric K-facto shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10 0 3 This table shows the listings and approvals available at the time of printing Check with the manufacturer for any additional approvals Listed by Underwriters Laboratones Inc for use in the U 5 and Canada , Fm Approved for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems) for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. o Auuepteuforuse. City of New York Board of Standards and Appeals, Calendar Number 219-76-SA cULus Listed as corrosion resistant 8 Listings and ApprovalS limited to Lrght Hazard Occupancies where allowed by the installation standards being app|/eu, with hydraulically calculated wet systems only. 8 The sprinkler orifice is bushed 19 Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol XVI 11 The Viking Microfast Model F-1 Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible elernerit of the sprinkler to be recessed behind the face of the wall or ceiling. ,' Certified, Standard sw1c2un'1.EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003 ,, Cf Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130. ` MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 • Sprinkler 41 d August 4, 2006 0 MICROFAST® AND NIIQ MicrofastHP® NG , TECHNICAL DATA QU ICK RESPONSE PENDENT SPRINKLERS TA - Vu Ste, .2 `', , ..4 aT ,i n -" + rte Re' m. !r� ` ,1 0 W ' i ff c 7 #' . ; -4 g ^ 0 ° : ; Als ef pca t althe l pprovaltOktar , 41 � � 5 - ' O t4g .. f �.. 1 1 c7 * i *g '' fin .1 R - r ,T1; , `ems'- ,�°T,.,_'�e.-.. a P .''�. <. ^�-- ✓._ e . - ; x .:��1^ �=s��.= ��:'��-a� =�;�?, d �...ri.���'bc� -�L. .� �� �."`.,�r�� cULus Listina Requirements: Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies (exception small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed FM Approval Reauirements: Quick Response Pendent Sprinklers are FM Approved as Indicated in the Approval Chart for use only In wet -pipe sprinkler systems (or preactlon systems qualifying as wet systems). For installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and /or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1 -2 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, Assemblee Pleniere, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Wrench I i Iasi= LJ �� Flat �x „ _Ili, 11 - - .It = -- — QI11 j (dE= , �- Pr otective Sprinkler Cap Illt - Wrench 12144W/B ** for installing coated and /or recessed sprinklers with protective caps = " •- - %. T-i Carefully slide the wrench 1 0896 ID)) sideways around the protective * *A 1/2" ratchet is required cap, ensuring engagement (not available from Viking). with the sprinkler wrench flats Figure 1: Standard Sprinkler Figure 2: Wrench 12144W/B for Installing Coated and /or Wrench 10896W/B and Recessed Pendent Sprinklers August 4, 2006 ' •' Sprinkler 41 e NIKI o y MICROFAST® AND 4 TECH NICAL, 'DATA MjcrofastHP® QU ICK RESPONSE PENDENT SPRINKLERS Ceiling Opening Size: 2- 5/16" (59 mm) Minimum, 2 -1/2" (64 mm) Maximum 2-1/8 (54 mm) (15 mm) ~ .— I NPT tbdIl l.m• ■ -.41 , ��ttSlb \ �� t 1 -3/4" 2 -1/4" 1 -1/2" 1 -3/4' (58 mm) I A 2 (44,5 mm) �381 mm ( , ) (44,5 mm) �l s (5 m Maximum mum m / Minimum Pendent Sprinkler 06662B Installed Pendent Sprinkler 06662B with a Standard 1/8" (3,1 mm) Pendent Sprinkler 06662B Surface - Mounted Escutcheon Installed with the Microfast Model F -1 Adjustable Escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F -1 Adjustable Escutcheon Ceiling Opening Size: 2 -1/8" 2- 5/16" (59 mm) Minimum, 2 -1/8" - (54 mm) - 2-1/2" (64 mm) Maximum (54 mm) t ■ 1I ■ fi �_ -S 111:12%1111 r � - � ■r It��al VIP —i ■— 1-1/8" (28,6 mm) 1-3/4" Minimum 1 -1/8" (28,6 mm) (44,5 mm) A 2 RIP Minimum Maximum - - - -= -•- I (50,8 mm) j Maximum _ _ -• 1 Pendent Sprinkler 06662B Installed with the Micromatic Pendent Sprinkler 06662B Model E -1 Recessed Escutcheon Installed with the Mlcromatic Model E -2 Recessed Escutcheon Figure 4: Sprinkler Dimensions with the Model E -1 and E -2 Recessed Escutcheons