Permit CITY TIGARD MECHANICAL PERMIT l DEVELOPMENT SERVICES PERMIT #: MEC2004 -00601 .�� 1 3125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 9/9/2004 PARCEL: 2S 114AA -00100 SITE ADDRESS: 08680 SW DURHAM RD SCHL. SWIM CTR. SUBDIVISION: ZONING: R -4.5 BLOCK: LOT: JURISDICTION: TIG CLASS OF WORK: ALT FLOOR FURN: EVAP COOLERS: TYPE OF USE: COM UNIT HEATERS: VENT FANS: OCCUPANCY GRP: VENTS W/O APPL: VENT SYSTEMS: 3 STORIES: BOILERS /COMPRESSORS HOODS: FUEL TYPES 0 - 3 HP: DOMES. INCIN: LPG 3 - 15 HP: COMML. INCIN: MAX INPUT: BTU 15 - 30 HP: REPAIR UNITS: FIRE DAMPERS ?: 30 - 50 HP: WOODSTOVES: GAS PRESSURE: 50 + HP: CLO DRYERS: FURN < 100K BTU: AIR HANDLING UNITS OTHER UNITS: FURN > =100K BTU: <= 10000 cfm: GAS OUTLETS: 3 > 10000 cfm: Remarks: Venting and gas piping for replacement of (2) boilers and (1) water heater. Owner: FEES SCHOOL DISTRICT 23J Description Date Amount 6900 SW SANDBURG RD [MECH] Permit Fee 9/9/2004 $130.00 TIGARD, OR 97223 [TAX] 8% State Surcharl 9/9/2004 $10.40 Phone: 503 431 - 4000 Total $140.40 Contractor: REQUIRED INSPECTIONS Phone: Gas Line lnsp Mechanical lnsp Reg #: Misc. Inspection Final Inspection This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain copies of these rules or direct questions to OUNC by calling (503)246 -669 .— Issued By: Permittee Signature: �G� (�f'"f�!�) Call (503) 639 -4175 by 7:00 P.M. for inspections needed the next business day Mechanical Permit Application , FOR OFFICE U _ . . - SEO( 13125 SW Hall Blvd , Tigard, OR 97223 ' ON ' ' • ; _ .. , . City of Tigard . Received Date/By • ffA 1 i ii Permit No Plan Review Phone. 503.639.4171 Fax: 503.598.1960 ta.,eolte t Date/By Other Permit Inspection Line 503 639 4175 —14 el 1 Date Ready/By. R7 See Page 2 for Internet: www.ci.tigard.or.us Notified/Method 011 Supplemental Information "" 4 Vai'''''6&iiqit ':usk61-IE' CICLIST' F irai - L;:.41KqP*1-W•tx6Azi2", ,, ,11,W , A, , ,,Lt'.??,1= .!-;,,it,,,..,,d ..1.t-.4,4M ,, -,e- ,,-, -- -, '. 1 ,- , ''' . ' - Mechanical permit fees* are based on the value of the work 0 New construction 2"Addition/alteration/replacement performed Indicate the value (rounded to the nearest dollar) of all D Demolition D Other. mechanical materials, equipment, labor, overhead, and profit 1,ge,• :„.-7,,yEAA,_ ,7.k,-, ,,+, , ,,,lAw . , , i.,;,, Value. $ 5: 00. ° %„L.,__ • ',..'4, "M3 0 1- and 2-family dwelling E 0 Accessory building For special information use checklist 0 Multi 0 Master builder 0 Other: Description Qty Ea Total ,k1,!- '''ro'':;g-mixt:ii . ,- . ,' 1 H t ea Ing/cooling Job site address. gcso 5 p 0 g (M- 01 X P Air conditioning or heat pump (requires site plan showing placement) 14.00 City/State/ZIP. 77 6- 4-g 4' o u q. 2 z z (-I Furnace 100,000 BTU (ducts/vents) 14 00 Furnace 100,000+ BTU (ducts/vents) 17 90 Suite/bldg./apt. no.: Project name 7 (6 0 .- 4 j ,, y) Gas heat pump 14 00 Cross street/directions to job site: C-4,4"- Duct work ,_ 14 00 Hydromc hot water system 14 00 Residential boiler (radiator or hydronic) 14 00 ._ Unit heaters (fuel-type, not electric), in-wall, in-duct, suspended, etc 10 00 _ _ Flue/vent for any of above 2, 10 00 Subdivision: Lot no.: Other. 10 00 Tax map/parcel no.: Other fuel appliances ,iiiiii:MEIXT:A6,.. Water heater 10 00 11.4 Gas fireplace 10.00 ■vd: ..— 17 (9) 1 00j,./....4 5 •1- (6 wiPtrf. L 1-1-61-71, ,.. Flue vent for water heater or gas fireplace 1 WA4 /4-E4-71P Log lighter (g„) 10 00 Wood/pellet stove 10 00 Wood fireplace/insert 10 00 itcp ir ,,,, ; : Chimney/liner/flue/vent 10 00 -• 10 00 Nanle --- A-,0 - `1", .-1T 4- LA-Ti 0 , C.Ficiel 12 - r )1 4,7 12- t Cr- Environmental exhaust and ventilation Range hood/other kitchen Address: Le , ,. 4. ) ( .. ov o t. . -- 6 u IA I. equipment 10 00 City/State/ZIP1 1 2 .. .. t .. Oa 41. 2 Clothes dryer exhaust 10.00 Single-duct exhaust (bathrooms, Phone: (553) q 31- 400o Fax: ( ) toilet utility rooms) 6 80 0 *If:fail:4 eoN Ath c/crawlspace fans 10.00 ';•,,,, , &gt4g4 Other 10 00 Business name: Fuel piping Contact name: $5.40 for first four; $1.00 for each additional Furnace, etc Address: Gas heat pump City/State/ZIP: Wall/suspended/unit heater Phone: ( ) Fax: : ( ) Water heater 1 Fireplace E-mail: Range 47 W4v:' , : , is-q•Wfab'rI5iiyrw> 4 !' •11 s Barbecue a, ,,._ V dry (gas Business name: e 0 £.L i rii d i_cl / cry (... Clothes 80 er ) Other: Address. ? P , 0 8 ,„,, 2, 960 :OlitC NTA U 4.',..M City/State/ZIP: 4 5 ec ,_ 0 4 C 171-; 0 t e e 1 70 1145— Subtotal — - OG Minimum permit fee ($72 50) Phone: (563) 72 O i 3 i Fax: (S (9 cs-6 _ /..,‘ R7 Plan review (25% of permit fee) CCB lie.. / 9' re:13 State surcharge (8% of permit fee) /0 .5Z- Authorized signature: ei I A k._ ---•"(- TOTAL PER MIT FEE.i.qt0 xpires if a permit is not obtained within 180 This permit application e days after it has been accepted as complete. Print name: atitAJ/06. i, CO (....L, /,,,,, 5 Date 'r - 49 6 f e . Fee methodology set by Tri-County Building Industry Service Board 1 \Building \ Perrruts \ MEC-PerrrutApp doe 12/03 440-4617T ( I 1/02/COM/WEB) . , Mechanical Permit Application - City of Tigard • Page 2 Supplemental Information Commercial Fee Schedule: .Totaul s aluat on ; :, E.:. $ 1.00 to $2,000.00 Minimum fee $72.50 $2,001.00 to $5,000.00 $72.50 for the first $2,000.00 and $2.30 for each additional $100.00 or fraction thereof, to and including $5,000.00. $5,001.00 to $10,000.00 $141.50 for the first $5,000.00 and $1.80 for each additional $100.00 or fraction thereof, to and including $10,000.00. $10,001.00 to $50,000.00 $231.50 for the first $10,000.00 and $1.35 for each additional $100.00 or fraction thereof, to and including $50,000.00. $50,001.00 to $100,000.00 $771.50 for the first $50,000.00 and $1.25 for each additional $100.00 or fraction thereof, to and including $100,000.00. $100,000.01 and up $1,396.50 for the first $100,000.00 and $1.10 for each additional $100.00 or fraction thereof. Note: All new commercial buildings require 2 sets of plans. i \Building\Permits\MEC- PermmtApp doc 12/03 2 CITY OF TIGARD 24 -Hour BUILDING Inspection Line: (503) 639 -4175 MST INSPECTION DIVISION . Business Line: (503) 639 - 4171 BUP Received Date Requested 4- — AM PM BUP Location g g■ U/? Suite MEC ° 60 60/ Contact Person Ph ( ) � � c l' - /7a ' PLM Contractor �! Ph ( ) SWR BUILDING Tenant/Owner ELC Footing Foundation ELC Access: Ftg Drain ELR Crawl Drain Slab Inspection Notes: SIT Post & Beam Shear Anchors at Sheath/Shear Int Sheath/Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof A A/ t� Other: Final PASS PART FAIL v _- PLUMBING Post & Beam Under Slab Rough -In Water Service Sanitary Sewer Rain Drains Catch Basin / Manhole • Storm Drain Shower Pan Other: Final PASS PART FAIL MECHANICAL Post & Beam Rough -In Gas Line - oke P ampers PAS • PART FAIL L TRICAL Service Rough -In UG/Slab Low Voltage Fire Alarm Final Reinspection fee of $ required • - - - •ext inspection. Pay at City Hall, 13125 SW Hall Blvd. PASS PART FAIL SITE ❑ Please call fo reinspe on RE: \ El Unable to inspect — no access Fire Supply Line 1I /IM ADA Approach/Sidewalk Date � Inspector , !• Ext Other: _r Final DO NOT REMOVE this inspection record from the job site. PASS PART FAIL