D. M. THOMPSON, INC. 1080 SW Westwood Drive
Engineer /Construction Management Portland Oregon 97239
(503) 293 -3811
April 19, 2007
David Green Construction
29100 SW Burkhalter Rd.
Hillsboro, OR 97123
Re: Office addition for Super Floors
Tigard, OR
Subject: Onsite inspection of framing and plan modifications
Mr. David Green:
On April 17, 2007, we visited the referenced construction site in order to examine certain framing and
construction modifications that vary from the original design drawings. These changes are addressed
below:
1. The bottom flight of the new stair to the second level has been fastened to the concrete floor
with powder driven pins in lieu of wedge anchors that are detailed. This method of anchorage is an
acceptable installation, since the stair is completely supported by walls on both sides.
2. Upper floor walls have not been constructed to the roof structure as detailed. The addition
of 2x6 bracing at —45 angles from the top, wall plates to the sides of the existing roof beams /puxlins
will be necessary to support the wall in both directions. Connect the braces to the top of the wall with
Simpson LS70 at each brace end.
..m..iL> 3. The new glue - laminated beam at the edge of the new second floor has been connected to the
existing steel column as originally detailed. The support of this beam has been changed so that it is
completely supported on new columns and footings and the welded connection at the steel column is
now redundant, No special welding inspection or approval are necessary for this connection,
Please call us if there are any questions or conditions that we have not addressed.
Inspection and report by;
f 1 ''I+
Duane M. Thompson, PE
Oregon # 62.11 r1� �
. TO
06/13/07 WED 09:56 FAX 503 670 9147 CARLSON TESTING el 002
.1
Carlson Testing, • uJrm saran OR 0 cdO2 OF
rr „, v Ylfnn:IRCr OX JU60 HrrJarurO 4'[ n30_'S l7ARrlrJ ltd rll
rr;mtl nr,+r
Std. OR 97<rrr Aau.! Olt UI
Iewo tyk963.1.34,,4 (`I r0J/ qv, I••: Plunrx 041) LW MS
Construction Ma teri�J1s resting & Inspection a (0.1169.1 -77 Fu. l: rk, •,7W IrnC U9(63
b uPo2o60 7— oo �l
Special Inspection (D)
FINAL SUMMARY LETTER 70 SV ' t
June 12, 2007
T0704'117
City of Tigard
13125 SW Hall Blvd
Tigard, OR 97223 -8199
Attn: Building Department
Re: Superfloors Warehouse — Tenant Improvement
7244 SW Durham Road — Tigard, OR (f a b 0
Permit No.: BUP2007 -00113
Dear Sir or Madam:
This is to certify that in accordance with Section 1704.1.2 of the International Building Code, we have performed special
inspection of the following item(s) per our inspection reports only:
Installation of Adhesive Anchors
All inspections and tests were performed and reported according to the requirements of Project Documents and, to the
best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders
and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's
design changes, approvals and verbal instructions.
Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in
full, without prior authorization from this office.
If there are any further questions regarding this matter, please do not hesitate to contact this office.
Respectfully submitted,
CARLSON TESTING, INC. Steven Leach
Project Manager
SW L /tm