Report Main owe Satan Office Bend Office f Riley Rd 611 Carlson Testing, Inc. 4 (S J60 4060 e o9�2f7 Phone. (541) Construction Materials Testing & Inspection Fax :503168) -0954 F ::/503)589 -/309 F�ISJ/13349(63 Special Inspection FINAL SUMMARY LETTER December 13, 2006 T06011690 City of Tigard 13125 SW Hall Blvd Tigard, OR 97223 -8199 Attn: Building Department Re: Bella V_istaSubdivision- Lot 1,5 12783 SW DaVinci Street- Tigard, OR Permit# MST2005 -0410 Dear Sir or Madam: This is to certify that in accordance with Section 1704.1.2 of the International Building Code, we have performed special inspection of the following item(s) per our inspection reports only: Installation of Adhesive Anchors All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are . y further questions regarding this matter, please do not hesitate to contact this office. Respectf submitted, . - -- CARLSe ESTING 'C. Jam- - . Hietpas Op= .'ions Manager /ks 'c: Reese General Contractors Inc- Arnold Reese CSA Consulting Engineers McNaughton Associates Inc May. 26. 2006 5:48PM No. 4502 P. / 7 /3 c., 'cur die fngineErinq InC - Real -World Geoteebnical SotuUone Investigation • Design • Construction SuppiWt May 26, 2006 Project No. 02 -7801 Attention: Rob Harp O _C COPY Riverside Homes, Inc. 1925 SIN ArnberGlen Parkway, Ste 200 Beaverton, OR 97008 Fax 303 - 968 -9165 RE: SOIL ENGINEER'S REVIEW OF FOUNDATION EXCAVATION SUEGRADE LOT 15 - SERA VISTA - TIGARD, OREGON References: 1. GeoPacific Engineering Inc, Geotechnicaf Report, Sella Vista, Tigard, Oregon, dated December 9, 2002. 2. GeoPadfic Engineering Inc., Sod and Wall Engineer's Summary at Conclusion or Earthwork, Bella Vim, Tigard, Oregon, June 15, 2005. GeoPecific Engineer, Jim Imbrie, visited the site to review the foundation excavation subgrade. The observed subgrade is fractured rock and residual soil. The current subgrade shows up to 2 inches of muck and standing water; however it will likely dry quickly once the rains subside. Based on our observations, it is our opinion that the current foundation subgrade is suitable for spread foundation support to a maximum allowable bearing pressure of 1,500 psf, with the exception of a small area at the rear of the home, where the perimeter footing is too dose to a near vertical cut. The cut should be supported by compacted gravel or preferably extra concrete poured in the short wall below this area. Setbacks on adjoining rockery walls are adequate. This lot is likely to have some groundwater seeping into the crawispace. Drainage and the use of drain rock inMlll needs to be 'Neff placed to control flow to the lowpoint drain. Our work scope pertains to geotechnical engineer's foundation excavation review only and the conditions existing and exposed at the time of our site visit. No deck footing, patio, or other appurtenant structure subgrades were observed. Our work was performed to the current local standards of practice. No warranty is. herein expressed or implied. If you have any questions, please call. Sincerely, GeoPacific Engineering, Inc. � y� � s 47 , (' 1443 James D. Imbue, P.E., C.E.G. OREGON Geotechnicai Engineer ' .0 G ° ?D -d 7 J 4 ' 's D.