Special Inspection
FINAL SUMMARY LETTER
December 13, 2006
T06011690
City of Tigard
13125 SW Hall Blvd
Tigard, OR 97223 -8199
Attn: Building Department
Re: Bella V_istaSubdivision- Lot 1,5
12783 SW DaVinci Street- Tigard, OR
Permit# MST2005 -0410
Dear Sir or Madam:
This is to certify that in accordance with Section 1704.1.2 of the International Building Code, we have performed special
inspection of the following item(s) per our inspection reports only:
Installation of Adhesive Anchors
All inspections and tests were performed and reported according to the requirements of Project Documents and, to the
best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders
and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's
design changes, approvals and verbal instructions.
Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in
full, without prior authorization from this office.
If there are . y further questions regarding this matter, please do not hesitate to contact this office.
Respectf submitted, . - --
CARLSe ESTING 'C.
Jam- - . Hietpas
Op= .'ions Manager
/ks
'c: Reese General Contractors Inc- Arnold Reese
CSA Consulting Engineers
McNaughton Associates Inc
May. 26. 2006 5:48PM No. 4502 P.
/ 7 /3 c.,
'cur die
fngineErinq InC -
Real -World Geoteebnical SotuUone
Investigation • Design • Construction SuppiWt
May 26, 2006
Project No. 02 -7801
Attention: Rob Harp O _C COPY
Riverside Homes, Inc.
1925 SIN ArnberGlen Parkway, Ste 200
Beaverton, OR 97008
Fax 303 - 968 -9165
RE: SOIL ENGINEER'S REVIEW OF FOUNDATION EXCAVATION SUEGRADE
LOT 15 - SERA VISTA -
TIGARD, OREGON
References:
1. GeoPacific Engineering Inc, Geotechnicaf Report, Sella Vista, Tigard, Oregon, dated December 9, 2002.
2. GeoPadfic Engineering Inc., Sod and Wall Engineer's Summary at Conclusion or Earthwork, Bella Vim, Tigard, Oregon,
June 15, 2005.
GeoPecific Engineer, Jim Imbrie, visited the site to review the foundation excavation subgrade. The observed
subgrade is fractured rock and residual soil. The current subgrade shows up to 2 inches of muck and standing
water; however it will likely dry quickly once the rains subside. Based on our observations, it is our opinion that
the current foundation subgrade is suitable for spread foundation support to a maximum allowable bearing
pressure of 1,500 psf, with the exception of a small area at the rear of the home, where the perimeter footing is
too dose to a near vertical cut. The cut should be supported by compacted gravel or preferably extra concrete
poured in the short wall below this area. Setbacks on adjoining rockery walls are adequate. This lot is likely to
have some groundwater seeping into the crawispace. Drainage and the use of drain rock inMlll needs to be 'Neff
placed to control flow to the lowpoint drain.
Our work scope pertains to geotechnical engineer's foundation excavation review only and the conditions
existing and exposed at the time of our site visit. No deck footing, patio, or other appurtenant structure
subgrades were observed. Our work was performed to the current local standards of practice. No warranty is.
herein expressed or implied. If you have any questions, please call.