Correspondence (Q — C)c 3 ti
October 30, 2006 a.0
CITY OF TIGARD
OREGON
Amato Development Corp.
Ted Amato
5151 SW Santa Monica Ct.
Portland, OR 97221
•
RE: CORAL STREET — 5 ROWHOUSES
Project Information
Building Permit "Varies" see below Construction Type: 5B
Tenant Name: "Varies" Occupancy Type: R3
Address: "Varies" Coral St. Stories: 2
The plan review is performed under the State of Oregon Residential Specialty Code (ORSC) 2005 edition
2003 International Fire Code as amended by TVF &R. The following plan with permits is approved for
construction subject to the following conditions.
Lot 1 9405 SW Coral St. Lot 3 9403 SW Coral St Lot 5 9399 SW Coral St.
MST2006-00192 MST2006 -00190 MST2006-00193
Lot 2 9407 SW Coral St. Lot 4 9401 SW Coral St
MST2006- 00194 MST206-00191
CONDITIONS
1. The City of Tigard, Building Division, is requiring Structural Observations per section 1709
Oregon Structural Specialty Code (OSSC). The owner shall employ a registered design professional
to perform structural observations as defined in Section 1702, OSSC. The structural observations
shall take place after the framing of each floor level prior to the installation of floor joist or
roof trusses above the structural framing. Deficiencies shall be reported in writing to the owner
and to the City of Tigard, Building Division, attention Hap Watkins. FYI The structural
observations do not waive the framing inspection required by code.
2. Shear -wall Sheathing and Gypsum Sheathing shall be attached and inspected in stairwells prior to the
construction of stairs or landings.
3. Safety glazing including but not limited to: the following locations: Each unit of glazing shall be
permanently identified by the manufacturer. Sec. 2406. Some of these locations are as follows:
a. Glazing in ingress and means of egress doors.
b. Glazing in storm doors.
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
c. Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical
edge is within a 24" arc of the door in a closed position and whose bottom edge is less than
60" above the floor or walking surface except when there is an intervening wall or other
permanent barrier between the door and the glazing.
4. Deferred submittals such as Truss Joist Shop Drawings, suspended ceiling system etc, will be charged a
deferred submittal fee based on the valuation of the portion of the work being deferred. The minimum fee
shall be ;200.00. This fee is in addition to the project plan review fee based on the total project value.
OAR 918 - 050 -0150 Deferred Items: None listed
"Documents for d fenrd submittal items shall be submitted to the ngisterrd design professional in responsible charge
who shall renew them and forward them to the building official with a notation indicating that the &fond submittal
documents have been rruewed and been found to be in general corformana to the design of the building The d fernd
submittal items shall not be installed until the design and submittal documents have been approved by the building
Odd Oregon Structural Specially Code Section 106.3.4.2"
NOT PART OF THIS REVIEW:
Plumbing, Electrical, Mechanical
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained
on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of
construction. R106.3.1 ORSC
Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official
has issued a certificate of occupancy R110.1 ORSC
Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such
a position as to be plainly visible and legible from the street or road fronting the property. OFC 505.1
When submitting revised drawings or additional information, please attach a copy of the enclosed City of
Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and
processing the documents.
Respec
Val enzel,
Senior Plans Examiner