Specifications • Fps 2_011.-001,( 7 ED 10 z6.0 s� ✓ f► • RECEIVED ,1 go 5 • Si1'1'1pieX OCT 4 2011 LifeAlarm Fire Alarm Controls UL, ULC, CSFM Listed; FM Ap 3pFTIG t, ,' • IDNet NAC Extender for Control from 4010 or MEA (NYC) Acceptance` - - Ul --D11 a YJ et Communications; or from Conventiorial NACs Features' Provides additional notification appliance circuit • (NAC) capacity with flexible operation modes and • •• power- limited design Up to 8 NACs Four, Class B (Style Y) NACs are standard: 1 L 21 0 • Rated 2 A each for conventional reverse polarity 4009 IDNet 24 VDC notification appliances and providing NAC Extender - - - - multiple operation modes NOUNP NII • Can be selected to provide synchronization for Simplex visible notification strobe flashes Q Optional IDNet • Capable of controlling TrueAlert non - addressable 4•9 ,x Channel Repeater �E_.. PC . notification appliances operating with SmartSyncTm g= two -wire control mode ** `� ` Input control options: ! \. ■ • 2 -Wire IDNet IDNet addressable communications from a Simplex Communications g ` `� � ■ `� . ■ model 4010 or 4100U Fire Alarm Control Panel ** r . r Fiber Optic IDNet ■ • Or from one or two conventional 24 VDC NACs with • I Communications ar `. multiple output control options ..., NAC Control IDNet communications control benefits: . -' / • • Provides status monitoring and individual NAC control 6= IDNet Fiber i • ,z5. 1 using a single address per 4009 IDNet NAC Extender Optic Transmitter • Supports IDNet "Device Level" earth fault location WALKTESTTM operation is available with either 4 0 0 (shown) Al p 4100U Fire Alarm input choice Control Panel . Internal 8 A power supply /battery charger: Fire Alarm Control Panel with Conventional NACs • Charges internal batteries up to 12.7 Ah or up to 18 Ah batteries in external cabinet • • Provides status monitoring of battery, input power, and 4009 IDNet NAC Extender Connection Reference Drawing earth faults Introduction • Rated 8 A for "Special Application" appliances; • including Simplex 4901, 4903, 4904, and 4906 Series ADA Compliance. Complying with the notification horns, strobes, hom/strobes, and speaker /strobes requirements of ADA (Americans with Disabilities Act) Rated'6 A for "Regulated 24 DC" appliance power may require more notification appliance power than is • available within the fire alarm control panel. When Optional 4009 IDNet NAC Extender modules: additional power is required, a Simplex 4009 IDNet NAC . • IDNet Communications Repeater provides Class B Extender can provide up to 8 A of NAC power with up to (Style 4) or Class A (Style 6) output eight, supervised reverse polarity NACs. • IDNet Communications Fiber Optic Receiver/Repeater, Location Flexibility. The 4009 IDNet NAC Extender • available as Class B or Class A can be mounted close to a compatible dedicated host • . Four additional Class B NACs, rated 1.5 A for Special panel or can be located remotely for convenient power Application appliances; 1 A for Regulated 24 DC distribution. Multiple operation modes and multiple . appliance power connection options further increase location flexibility. . • Class A (Style Z), Two Circuit Adapter Module Additional Information. For additional operation detail UL Listed to Standard 864 and application information, refer to Installation Instructions 574 -181 and field wiring diagram 842 -068. External Accessories • ULC listed model is 4009-9202CA. This product has been approved by the California State IDNet communication fiber optic transmitters: Fire Marshal ( CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. p See CSFM Listing 7300-0026:214 for allowable values and/or conditions concerning- • For applications requiring,the data integrity available matedal presented in this document It is subject tore- examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35 -93E. • . with fiber optic communications Additional listings may be applicable; contact,your local Simplex product supplier for the • Available as Class B (Style 4) or Class A (Style 7) latest status. Listings and approvals under Simplex Time Recorder Co. are the property of • Tyco Safety Products Westminster. • • • Mounts in standard six-gang electrical box - •• SmartSync hom/strobe operation is protected under U.S. Patent No. 6,281,789. IDNet • External battery cabinet for 18 Ah batteries addressable communications are protected under U.S. Patent Nos. 4,796.025; . 5,966,002; and 6,034,601. 4100U requires revision 11 software or higher for T Simplex WALKTEST service testing is protected under U.S. Patent No. 4,725,818. compatibility. 4010 requires revision 2 software or higher for compatibility. S4009 -0002-4 2/2006 Application`and�Operation Information; Hardwire Control Applications. For applications where an existing (or new) conventional NAC needs IDNet Addressable Communications Compatible. additional power, the 4009 IDNet NAC Extender can be Up to five, 4009 IDNet NAC Extenders can be controlled controlled directly from the NAC. Either one or two on a single IDNet communications channel. Each output NACs, from either the same, or from different host fire NAC can be individually controlled for general alarm or alarm control panels, can be connected to control the 4009 selective area notification requiring only one point IDNet NAC Extender output NACs. Multiple control address per Extender. Individual Extender NACs can also selections provide flexible operation. (Refer to page 4 for be manually controlled from the host panel. IDNet more detail.) Alarms from the host panel will activate the controlled extenders will inform the host panel of troubles four, 4009 IDNet NAC Extender NACs (or optionally, via IDNet communications. eight NACs) to extend the alarm. Optional IDNet Repeaters. IDNet communications The 4009 IDNet Extender monitors itself and each of its can be repeated with the optional IDNet Repeater Module output NACs for trouble conditions, including earth or with the optional Fiber Optic Receiver Module. Up to faults. Extenders wired to conventional NACs will 100 of the IDNet channel points can be repeated once indicate a trouble by opening the path to the NAC's (refer to pages 3 and 5 for details). Repeated IDNet end -of -line resistor, but retaining the ability to respond to . communications also support the "device level" earth alarms. Individual troubles are also annunciated by LEDs fault location utility of the host panel. located on the 4009 IDNet NAC Extender main circuit board. (Refer to page 7 for more diagnostic information.) .Product Selection Standard Models Model Description 4009-9201 120 VAC input 4009- 9202CA* 4009 IDNet NAC Extender with 4, Class B (Style Y) NACs and 8 A power supply 4009 -9301 240 VAC input • ULC listed model Optional Modules (for on -site installation) Model Description Comments Additional four point NAC module, rated 1.5 A Special 4009 -9807 Application appliances; 1 A for Regulated 24 DC appliance One maximum power, Class B (Style Y), 4009 -9808 Dual Class A (Style Z) adapter (for two NAC outputs) Select as required (4 maximum) 4009-9809 IDNet Repeater, output is Class A (Style 6) or Class B (Style 4) Select either an IDNet Repeater or a 4009 -9810 Fiber Optic Receiver Class B (Style 4) Fiber Optic Receiver as required 4009 -9811 Class A (Style 7 fiber, Style 6 IDNet) 4009 -9805 Red Applique for door Select if required 2975 -9801 Semi -Flush Trim Kit Beige trim 1 -7/16" wide (78 mm), use if required for 2975 -9802 Red trim semi -flush installations Battery Selection (select battery size per system requirements) Model Description Comments 2081 -9272 6.2 Ah Battery, 12 VDC 2081 -9274 10 Ah Battery, 12 VDC Two batteries are required, 24 VDC operation 2081 -9288 12.7 Ah Battery, 12 VDC 2081 -9275 18 Ah Battery, 12 VDC Requires external battery cabinet, two batteries are required, 24 VDC operation External Accessories (select per system requirements) Model Description Comments 4090 -9105 IDNet Fiber Optic Class B (Style 4) operation Mounts in six -gang electrical box, refer to 4090 -9107 Transmitter Class A (Style 7) operation page 4 for mounting details 4009 -9801 External battery cabinet for up to 18 Ah batteries, beige 16-1/4" W x 13-1/2" H x 5-3/4" D (413 mm x 343 mm x 146 mm) 4081 Series End-of -Line Resistor Harnesses; see data sheet S4081 -0003 for details 2 S4009-0002-4 2/2006 Typical IDNet Connection Example .m c :: Typical IDNet compatible devices (Refer to individual devices for actual wiring requirements, some wiring is not shown.) :r o mo 171 * 1 i 1 ■ IDNet addressable communications channel, ! /shown Class B (Style 4) Output NACs, four standard, Conventional NAC operation (horns) eight with expansion option -A Select conventional _ —_, — or SmartSync operation per NAC 4100U (shown) or 4010 Fire _ Alarm Control Panel _ = Q 4 ► nrmm�a o SmartSync operation (horns and strobes) gIC1 4009 IDNet NAC Extender with E _i-P.. internal IDNet Repeater a Conventional NAC 1 ,,,, operation (strobes) • Repeated IDNet Channel; ® 11111111111 iler up to 100 devices maximum on repeater output, 250 devices total on IDNet Channel .. .l] TTl flTfil IDNet devices and additional 4009 IDNet NAC Extender(s) NOTE: Up to five (5) 4009 IDNet NAC Extenders may be connected to one IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Typical Fiber Optic System Connections Two fiber cables, 3000 ft Output NACs 4090 -9105, Class B (914 m) maximum distance 1O00001011P ; (Style 4) Output Fiber I IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIINIIINIIIIIIIINIII .`" Optic Transmitter ' k4 ' ;5" - . : =IN l■ ME f 1 • / tli '11111P-.' o O +- IDNet addressable communications J' 'sir- channel Class B (Style 4) or Class A (Style 6), Class B shown Repeated joret Channel; up to 100 devices maximum on repeater output, 250 devices total on IDNet Channel IIIIIIIIIOIIII111101111111110111IIIINIIOIEIIIIIII I:t Four fiber cables, 3000 ft 4010 or 4100U Fire (914 m) maximum distance Alarm Control Panel _ • 24 VDC power for _ � • 111101.10010 ® ..L fiber optic transmitters _i= Ui lit 4090 -9107, Class A (Style 7) • 4 j j `m' . Output Fiber Optic Transmitter 111' P• Emil 4009 IDNet NAC Extenders with optional Output NACs internal IDNet Fiber Receivers NOTE: Up to five (5) 4009 IDNet NAC Extenders may be connected to one IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Fiber optic transmitters connect to only one 4009 IDNet NAC Extender. 3 S4009 -0002-4 2/2006 • 5 True /ert Multi - Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC) Acceptance* Non - Addressable, SmartSyncTM Operation Compatible Features ii•EximamisiPm Visible only (V /O) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: • • UL listed to Standard 1971 • Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing • Operation is compatible with ADA requirements (refer to important installation information on page 3) • Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Wall Mount Strobes • Regulated circuit design ensures consistent flash output 11111. =M and provides controlled inrush current • Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens IMM Strobes provide synchronized flash for use with: • 4006, 4008, 4010, and 4100U Series fire alarm control Ceiling Mount Strobes panels with NACs selected to provide strobe synchronization or Smart Sync two -wire control ** Descri • tion • 4009 IDNetTM NAC Extenders Multi - Candela TrueAlert synchronized strobes • Separate strobe Synchronization Modules that are provide convenient installation to standard electrical available for Class B or Class A operation boxes. The enclosure designs are both impact and vandal • Separate SmartSync Control Modules (SCMs) that resistant and provide a convenient strobe intensity provide Class B or Class A output from conventional selection. Since each model can be selected for intensity NAC inputs output, on -site model inventory is minimized and changes encountered during construction can be easily Strobe housings provides flexible, easy, and accommodated. convenient semi -flush or surface wall mounting: Wall mount strobe housings are a one -piece assembly • Rear of housing does not extend into box (including lens) that mounts to a single or double gang, or • Wall mount strobes easily mount to single gang, double 4" square standard electrical box. The cover can be gang, or 4 -inch square outlet box quickly removed (a tool is required) and covers are • Ceiling mount strobes mount to single gang boxes available separately for color conversion. Wall mount strobe features: Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model • Wiring terminals are accessible from the front of the number. housing providing easy access for installation, inspection, and testing Strobe Intensit Selection • Covers are available separately to convert housing color During installation, a selection plug at the back of the Optional adapters and wire guards: housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow • Wall mount strobe adapters are available to cover background allows the selected intensity to be seen at the surface mounted electrical boxes and to adapt to side of the strobe lens. Simplex 2975 -9145 boxes • UL listed red wire guards are available for wall or Strobe Application Reference ceiling mount strobes Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI • This product has been approved by the California State Fire Marshal (CSFM) pursuant to A117.1; the appropriate model building code: BOCA, Section 13144.1 of the California Health and Safety Code. See CSFM Listing ICBO, or SBCCI; and the application guidelines of the 7125-0026:316 for allowable values andlor conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Refer to Americans with Disabilities Act (ADA). page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. listings and approvals under Simplex " Simplex multi-candela SmartSync two-wire nom/strobe appliance operation is protected Time Recorder Co. are the property of Tyco Safety Products Westminster. under one or more of the following U.S. Patent Numbers: 5,559,492; 5,622,427; 5,865,527; 5,886,620; 6,281,789; 6,954,137; 7,005,971; and 7,006,003. S4906- 0001 -3 5/2008 • Synchroni ed St SmartSync`Coritrol.Sources: Multiple Strobes. When multiple strobes and their Class B Smart Sync two -wire control is available reflections can be seen from one location, synchronized from: flashes reduce the probability of photo- sensitive reactions • 4006, 4008, 4100U, and 4010 Fire Alarm Control as well as the annoyance and possible distraction of Panels (refer to individual product data sheets for more random flashing. These multi- candela strobes are information) • synchronized over a two -wire circuit when connected to • 4009 IDNet NAC Extender (refer to data sheet • compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules. S4009-0002) • SmartSync Control Module (SCM) 4905 - 9938 (refer to SmartSync-Two- WireControl data sheet S4905 - 0003) Some applications desire the audible notification Class A SmartSync two -wire control is available appliances to be capable of being silenced before the from 4100U NACs and from the 4905 -9938 SCM. alarm condition is reset (on- until- silenced) while the Additional SmartSync compatible notification visible notification appliances are kept activated until the appliances include separate horns and combination alarm condition is reset (on- until - reset). SmartSync horn/strobe notification appliances. operation mode provides this function using a single circuit (two -wire operation). Product Selection. Multi- Candela Visible Notification Appliances (Strobes) • Model Mounting Housing Color "FIRE" Lettering Description 4906 -9101 Red White 4906 -9103 Wall White Red Multi- candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate; 4906-9102 Ceiling Red White SmartSync two -wire control compatible 4906 -9104 g White Red Wall Mount Strobe Adapters Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1 -1/2" (38 mm) 5 3/8" H x 5 -1/4" W x 1 -5/8" D (136 mm x 133 mm x 41 mm) 4905 -9940 White deep surface mounted boxes Total depth with strobe = 4 -3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975 -9145 box (typically for 8 -5/16" x 5 -3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975 -9145 Red Mounting Box, requires Adapter Plate 4905 -9931 7-7/8" x 13 /8" x 0 mm'x D • (200 mm x 13 7 70 0 mm) Ceiling. Mount Strobe ' Model Description Dimensions 4905 -9910, Surface Mount Adapter Plate; zinc plated; required for mounting to 4 -7/8" x 3 -1/8" x 0.060" D handy box; not needed when using 4905 -9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905 -0003 for additional information) Model Description Dimensions 4905 -9914 Class B Synchronized Flash Module; epoxy encapsulated with 1 -3/8" x 2- 7/16" x 13/16" in /out 18 AWG (0.82 mm) wire leads, rated for 2 A NAC, (35 mm x 62 mm x 20 mm) 4905 -9922 Class A requires 10 mA for power 4905 9938 SmartSync Control Module with Class B or Class A output; mounts in 4" x 4 -1/8" x 1 -1/4" D 4" (102 mm) square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description Dimensions 4905 -9992 Red cover with white "FIRE" lettering 5 -1/8" H x 5" W x 1 -1/2" D For Wall mount strobes 4905 -9993 White cover with red "FIRE" lettering ( 130 mm x 127 mm x 38 mm) 4905-9961' Wall mount 6 -1/16" H x 6- 1/16" W x 3 -1/8" D • Red wire guard with mounting plate, compatible with (154 mm x 154 mm x 79 mm) semi -flush or surface mounted boxes 6 -1/8" x 4 -3/8" x 2 -7/8" deep 4905 -9926' Ceiling mount (156 mm x 111 mm x 73 mm) UL listed by Space Age Electronics Inc. • 2 54906- 0001 -3 5/2008 • , • •Strobe: S • ecification`s. Wall Mount or Ceiling Mount, Common Specifications ` " 'Rated Voltage Range -- UL_Listed.Rating_ _ Regulated_24 VDC see_Note_1_bel.ow ___ — ULC Listed Rating 20 VDC to 30 VDC per ULC S526 -M878 . Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93 %, non - condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm to 3.31 mm two wires per terminal for in /out wiring • Housing Dimensions (with lens) 5 -1/8" H x 5" W x 2 -3/4" D (130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Strobe Setting (see Note 2 below) 60 mA 94 mA 186 mA 252 mA Mount Reference RMS Currents 18 VDC 53 mA 84 mA 165 mA 224 mA at other voltages. 24 VDC 40 mA 63 mA 124 mA 168 mA Housing Dimensions (with lens) 4 -3/4" L x 2 -5/16" W x 2 -5/8" D (121 mm x 75 mm x 67 mm) Ceiling Maximum RMSCurrent Rating per 15 cd 30 cd . 75 cd 110 cd Strobe Settin g (see Note 2 below) 75 mA 125 mA 233 mA 7 316 mA Mount Reference RMS Currents 18 VDC •. 67 mA '111 mA 207 mA 281 mA at other voltages 24 VDC . 50 mA • 83 mA 155 mA 211 mA NOTES: • • 1. "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference; Surface or Semi-Flush .Wall Mounting Mounting is compatible with ra ( \ p ( \ I� single gang, double gang, and 1 1 4" (102 mm) square boxes, — 1 - 1/2" (38 mm) deep, by others i 1 i i r0� _ IMPORTANT! WALL MOUNT • INSTALLATION HEIGHT REFERENCE i Bottom of lens 0O AMC Ansel) !il - I 0 • is either even • Q 8 P ` i with, or slightly __•._ Electrical Wiring access hole I / N J 014 . . above bottom box outline �� G ®® of compatible �I; ©I � boxes Wiring terminals lIMI101 ti � II � I - 7 h Mounting Holes: , square (4) NFPA 72 requires 80" (2.03 m) "°°° 0004 0 =ftgl Single gang (2) that the entire lens minimum • 'ellT � Double gang (3) be not less than 11 F 80" and not greater 1 than 96" above the • Transparent housing finished floor and lens assembly • Intensity selection i plug, accessible only from rear of housing; U ® IF I] n I • factory setting is 15 cd . Removable cover . Strobe intensity •_ . . . (tool required) viewing slot • . . 3 S4906- 0001 -3 5/2008 ' [Page Too Large for OCR Processing] [Page Too Large for OCR Processing] [Page Too Large for OCR Processing] [Page Too Large for OCR Processing] [Page Too Large for OCR Processing] [Page Too Large for OCR Processing] [Page Too Large for OCR Processing] f S0 c// -oW) 7 I ® 511`9`1pleX LifeAlarm Fire Alarm Controls UL, ULC, CSFM Listed; FM Approved; 4009 IDNet NAC Extender for Control from 4010 or MEA (NYC) Acceptance* 41000 IDNet Communications; or from Conventional NACs Featui.es, Provides additional notification appliance circuit o (NAC) capacity with flexible operation modes and �• ••• power - limited design Up to 8 NACs Four, Class B (Style Y) NACs are standard: C • Rated 2 A each for conventional reverse polarity 4009 IDNet 24 VDC notification appliances and providing NAC Extender _ multiple operation modes r • Can be selected to provide synchronization for si Simplex visible notification strobe flashes a Optional IDNet • Capable of controlling TrueAlert non - addressable 4.0 c m, .,....' Channel Repeater notification appliances operating with SmartSyncTM _ two -wire control mode ** I ` ` \ \ `, o =� / Input control options: r \. \ x • 2 -Wire IDNet ` ■ s IDNet addressable communications from a Simplex Communications or �‘ �‘ .. model 4010 or 4100U Fire Alarm Control Panel ** I . t Fiber Optic IDNet . • Or from one or two conventional 24 VDC NACs with t Communications or ` multiple output control options �o•� ® I . '` NAC Control i IDNet communications control benefits: F —' f ' • Provides status monitoring and individual NAC control • IDNet Fiber using a single address per 4009 IDNet NAC Extender 5 Optic Transmitter ' i • Supports IDNet "Device Level" earth fault location ° ^ 1MI®°1 °°°•° • 4010 (shown) or = - =_=-�— WALKTEST TM operation is available with either 4100U Fire Alarm - input choice Control Panel Internal 8 A power supply /battery charger: Fire Alarm Control Panel with Conventional NACs • Charges internal batteries up to 12.7 Ah or up to 18 Ah batteries in external cabinet • Provides status monitoring of battery, input power, and 4009 IDNet NAC Extender Connection Reference Drawing earth faults Introduction • Rated 8 A for "Special Application" appliances; including Simplex 4901, 4903, 4904, and 4906 Series ADA Compliance. Complying with the notification horns, strobes, horn/strobes, and speaker /strobes requirements of ADA (Americans with Disabilities Act) • Rated 6 A for "Regulated 24 DC" appliance power may require more notification appliance power than is available within the fire alarm control panel. When Optional 4009 IDNet NAC Extender modules: additional power is required, a Simplex 4009 IDNet NAC • IDNet Communications Repeater provides Class B Extender can provide up to 8 A of NAC power with up to (Style 4) or Class A (Style 6) output eight, supervised reverse polarity NACs. • IDNet Communications Fiber Optic Receiver/Repeater, Location Flexibility. The 4009 IDNet NAC Extender available as Class B or Class A can be mounted close to a compatible dedicated host • Four additional Class B NACs, rated 1.5 A for Special panel or can be located remotely for convenient power Application appliances; 1 A for Regulated 24 DC distribution. Multiple operation modes and multiple appliance power connection options further increase location flexibility. • Class A (Style Z), Two Circuit Adapter Module Additional Information. For additional operation detail UL Listed to Standard 864 and application information, refer to Installation . Instructions 574 -181 and field wiring diagram 842 -068. E Accessories ULC listed model is 4009- 9202CA This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. IDNet communication fiber optic transmitters: See CSFM Listing 7300 - 0026214 for allowable values and /or conditions concerning • For applications requiring the data integrity available material presented in this document. It is subject to re- examination, revision, and possible cancellation Accepted for use — City of New York Department of Buildings — MEA35 -93E with fiber optic communications Additional listings may be applicable, contact your local Simplex product supplier for the • Available as Class B (Style 4) or Class A (Style 7) latest status Listings and approvals under Simplex Time Recorder Co are the property of Tyco Safety Products Westminster. • Mounts in standard six-gang electrical box " SmartSync hom/strobe operation is protected under U.S Patent No 6,281,789 IDNet External battery cabinet for 18 Ah batteries addressable communications are protected under U S Patent Nos 4,796,025, 5,966,002, and 6,034,691 41000 requires revision 11 software or higher for t Simplex WALKTEST service testing is protected under U S Patent No 4,725,818. compatibility. 4010 requires revision 2 software or higher for compatibility. S4009- 0002 -4 2/2006 io' . " . ` ' Hardwire Control Applications. For Application arid�Op'eraton Information pP ' applications where an existing (or new) conventional NAC needs IDNet Addressable Communications Compatible. additional power, the 4009 IDNet NAC Extender can be Up to five, 4009 IDNet NAC Extenders can be controlled controlled directly from the NAC. Either one or two on a single IDNet communications channel. Each output NACs, from either the same, or from different host fire NAC can be individually controlled for general alarm or alarm control panels, can be connected to control the 4009 selective area notification requiring only one point IDNet NAC Extender output NACs. Multiple control address per Extender. Individual Extender NACs can also selections provide flexible operation. (Refer to page 4 for be manually controlled from the host panel. IDNet more detail.) Alarms from the host panel will activate the controlled extenders will inform the host panel of troubles four, 4009 IDNet NAC Extender NACs (or optionally, via IDNet communications. eight NACs) to extend the alarm. Optional IDNet Repeaters. IDNet communications The 4009 IDNet Extender monitors itself and each of its can be repeated with the optional IDNet Repeater Module output NACs for trouble conditions, including earth or with the optional Fiber Optic Receiver Module. Up to faults. Extenders wired to conventional NACs will 100 of the IDNet channel points can be repeated once indicate a trouble by opening the path to the NAC's (refer to pages 3 and 5 for details). Repeated IDNet end -of -line resistor, but retaining the ability to respond to communications also support the "device level" earth alarms. Individual troubles are also annunciated by LEDs fault location utility of the host panel. located on the 4009 IDNet NAC Extender main circuit board. (Refer to page 7 for more diagnostic information.) Product' Selection Standard Models Model Description 4009 -9201 120 VAC input 4009- 9202CA* 4009 IDNet NAC Extender with 4, Class B (Style Y) NACs and 8 A power supply 4009 -9301 240 VAC input ULC listed model Optional Modules (for on -site installation) Model Description Comments Additional four point NAC module, rated 1.5 A Special 4009 -9807 Application appliances; 1 A for Regulated 24 DC appliance One maximum power, Class B (Style Y), 4009 -9808 Dual Class A (Style Z) adapter (for two NAC outputs) Select as required (4 maximum) 4009 -9809 IDNet Repeater, output is Class A (Style 6) or Class B (Style 4) Select either an IDNet Repeater or a 4009 -9810 Fiber Optic Receiver Class B (Style 4) Fiber Optic Receiver as required 4009 -9811 Class A (Style 7 fiber, Style 6 IDNet) 4009 -9805 Red Applique for door Select if required 2975 -9801 Semi Flush Trim Kit Beige trim 1- 7/16" wide (78 mm), use if required for 2975 -9802 Red trim semi -flush installations Battery Selection (select battery size per system requirements) Model Description Comments 2081 -9272 6.2 Ah Battery, 12 VDC 2081-9274 10 Ah Battery, 12 VDC Two batteries are required, 24 VDC operation 2081 -9288 12.7 Ah Battery, 12 VDC 2081 -9275 18 Ah Battery, 12 VDC Requires external battery cabinet, two batteries are required, 24 VDC operation External Accessories (select per system requirements) Model Description Comments 4090 -9105 IDNet Fiber Optic Class B (Style 4) operation Mounts in six -gang electrical box, refer to 4090 -9107 Transmitter Class A (Style 7) operation page 4 for mounting details 4009 -9801 External battery cabinet for up to 18 Ah batteries, beige 16-1/4" W x 13-1/2" H x 5-3/4" D (413 mm x 343 mm x 146 mm) 4081 Series End -of -Line Resistor Harnesses; see data sheet S4081 -0003 for details 2 S4009- 0002 -4 2/2006 Li AT` ..iaeI'IDNet Connect on`Ezam.le; ° Tlo! F Typical IDNet compatible devices v ^t (Refer to individual devices for actual wiring requirements, some wiring is not shown ) L I. i / t � ... IDNet addressable communications channel, _ Class B (Style 4) Output NACs, four standard, Conventional NAC operation (horns) eight with expansion option _ - 4---- - Select conventional ^^_ = or SmartSync operation per NAC 4100U (shown) or 4010 Fire / Alarm Control Panel ® f o F `I - .,.E 1009 !MAC NAC' EXTENDER q SmartSync operation (horns and strobes) 4009 IDNet NAC Extender with optional internal IDNet Repeater Conventional NAC operation (strobes) ► Repeated IDNet Channel ® o 1111111111 up to 100 devices maximum on repeater output, 250 devices total on IDNet Channel °` ! iiiiinglifi IDNet devices and additional 4009 IDNet NAC Extender(s) NOTE: Up to five (5) 4009 IDNet NAC Extenders may be connected to one IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Typical Fiber Optic System Connections Two fiber cables, 3000 ft Output NACs 4090 -9105, Class B (914 m) maximum distance -- T ---- _.' (Style 4) Output Fiber - '; llllllllllllllllllllllllllllllllllllllllllllllllllllllllllll Optic Transmitter o g;■Ilinommi 7 _ n IDNet addressable communications F" channel Class B (Style 4) or Class A (Style 6), Class B shown Repeated IDNet Channel. up to 100 devices maximum on repeater output, 250 devices total on IDNet Channel IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Four fiber cables, 3000 ft 4010 or 41000 Fire (914 m) maximum distance Alarm Control Panel � I 1,- 24 VDC power for - -- � ___ _ _ fiber optic transmitters A j 4090 -9107, Class A (Style 7) * I El El Es= Output Fiber Optic Transmitter 4009 IDNet NAC Extenders with optional Output P Cs internal IDNet Fiber Receivers NOTE: Up to five (5) 4009 IDNet NAC Extenders may be connected to one IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Fiber optic transmitters connect to only one 4009 IDNet NAC Extender. 3 S4009- 0002 -4 2/2006 ® Si plex TrueAlert Multi - Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC) Acceptance* Non- Addressable, SmartSyncTM Operation Compatible Features; Visible only (V /O) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount:F. • UL listed to Standard 1971 • Intensity is selectable as 15, 30, 75, or 110 candela with MM visible selection jumper secured behind strobe housing • Operation is compatible with ADA requirements (refer W e=d' to important installation information on page 3) • Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Wall Mount Strobes • Regulated circuit design ensures consistent flash output r n= and provides controlled inrush current • Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Strobes provide synchronized flash for use with: • 4006, 4008, 4010, and 4100U Series fire alarm control Ceiling Mount Strobes panels with NACs selected to provide strobe synchronization or SmartSync two -wire control ** DesCri •tier' • 4009 IDNetTM NAC Extenders Multi - Candela TrueAlert synchronized strobes • Separate strobe Synchronization Modules that are provide convenient installation to standard electrical available for Class B or Class A operation boxes. The enclosure designs are both impact and vandal • Separate SmartSync Control Modules (SCMs) that resistant and provide a convenient strobe intensity provide Class B or Class A output from conventional selection. Since each model can be selected for intensity NAC inputs output, on -site model inventory is minimized and changes encountered during construction can be easily Strobe housings provides flexible, easy, and accommodated. convenient semi -flush or surface wall mounting: Wall mount strobe housings are a one-piece assembly • Rear of housing does not extend into box (including lens) that mounts to a single or double gang, or • Wall mount strobes easily mount to single gang, double 4" square standard electrical box. The cover can be gang, or 4 -inch square outlet box quickly removed (a tool is required) and covers are • Ceiling mount strobes mount to single gang boxes available separately for color conversion. Wall mount strobe features: Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model • Wiring terminals are accessible from the front of the number. housing providing easy access for installation, inspection, and testing Strobe Illtensit Selection • Covers are available separately to convert housing color During installation, a selection plug at the back of the Optional adapters and wire guards: housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow • Wall mount strobe adapters are available to cover background allows the selected intensity to be seen at the surface mounted electrical boxes and to adapt to side of the strobe lens. Simplex 2975 -9145 boxes • UL listed red wire guards are available for wall or Strobe Application Reference ceiling mount strobes Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI This product has been approved by the California State Fire Marshal (CSFM) pursuant to Al 17.1; the appropriate model building code: BOCA, Section 13144.1 of the California Health and Safety Code See CSFM Listing 7125 -0026 316 for allowable values and /or conditions concerning material presented in ICBO, or SBCCI; and the application guidelines of the this document It is subject to re- examination, revision, and possible cancellation Refer to Americans with Disabilities Act (ADA). page 2 for listing status of wire guards Additional listings may be applicable, contact your local Simplex product supplier for the latest status Listings and approvals under Simplex ** Simplex multi - candela SmartSync two-wire horn /strobe appliance operation is protected Time Recorder Co are the property of Tyco Safety Products Westminster. under one or more of the following U.S. Patent Numbers. 5,559,492, 5,622,427, 5,865,527; 5,886,620, 6,281,789, 6,954,137, 7,005,971, and 7,006,003 S4906- 0001 -3 5/2008 Synchroni ed.`Strobes SmartSync Control Sources;. Multiple Strobes. When multiple strobes and their Class B SmartSync two -wire control is available reflections can be seen from one location, synchronized from: flashes reduce the probability of photo - sensitive reactions • 4006, 4008, 4100U, and 4010 Fire Alarm Control as well as the annoyance and possible distraction of Panels (refer to individual product data sheets for more random flashing. These multi - candela strobes are information) synchronized over a two -wire circuit when connected to compatible NACs, to compatible Synchronized Flash • 4009 IDNet NAC Extender (refer to data sheet Modules, or to SmartSync Control Modules. S4009-0002) • SmartSync Control Module (SCM) 4905 - 9938 (refer to SrrartSyncjwo -Wire Control data sheet S4905 -0003) Some applications desire the audible notification Class A SmartSync two -wire control is available appliances to be capable of being silenced before the from 4100U NACs and from the 4905 -9938 SCM. alarm condition is reset (on- until - silenced) while the Additional SmartSync compatible notification visible notification appliances are kept activated until the appliances include separate horns and combination alarm condition is reset (on- until - reset). SmartSync horn/strobe notification appliances. operation mode provides this function using a single circuit (two -wire operation). P`rod`uctlelection Multi- Candela Visible Notification Appliances (Strobes) Model Mounting Housing Color "FIRE" Lettering Description 4906 -9101 Wall Red White 4906 -9103 White Red Multi- candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate; 4906 -9102 Red White SmartSync two -wire control compatible Ceiling 4906 -9104 White Red Wall Mount Strobe Adapters Model Description Dimensions 4905-9937 Re d Surface Mount Adapter Skirt; use to cover 1 -1/2" (38 mm) 5 -3/8" H x 5 -1/4" W x 1 5/8" D (136 mm x 133 mm x 41 4905 -9940 White deep surface mounted boxes (11 Total depth with strobe = 4 -3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975 -9145 box (typically for 8- 5/16" x 5 -3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975 -9145 Red Mounting Box, requires Adapter Plate 4905 -9931 7-7/8" x 5 -1/8" x 2 -3/4" D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter Model Description Dimensions 4905 -9910 Surface Mount Adapter Plate; zinc plated; required for mounting to 4 -7/8" x 3 -1/8" x 0.060" D handy box; not needed when using 4905 -9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905 -0003 for additional information) Model Description Dimensions 4905 -9914 Class B Synchronized Flash Module; epoxy encapsulated with 1 -3/8" x 2-7/16" x 13/16" in /out 18 AWG (0.82 mm) wire leads, rated for 2 A NAC, (35 mm x 62 mm x 20 mm) 4905 -9922 Class A requires 10 mA for power 4905 -9938 SmartSync Control Module with Class B or Class A output; mounts in 4" x 4 -1/8" x 1 -1/4" D 4" (102 mm) square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description Dimensions 4905 -9992 Red cover with white "FIRE" lettering 5 -1/8" H x 5" W x 1 -1/2" D For Wall mount strobes 4905 -9993 White cover with red "FIRE" lettering ( 130 mm x 127 mm x 38 mm) 4905 -9961' Wall mount 6- 1/16" H x 6 -1/16" W x 3 -1/8" D Red wire guard with mounting plate, compatible with (154 mm x 154 mm x 79 mm) 4905 9926' Ceiling mount semi -flush or surface mounted boxes 6 -1/8" x 4 -3/8" x 2 -7/8" deep (156 mm x 111 mm x 73 mm) UL listed by Space Age Electronics Inc 2 S4906- 0001 -3 5/2008 P a, { Strobe's ` . ecifications: Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 VDC; see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526 -M878 Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93 %, non - condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm to 3.31 mm two wires per terminal for in /out wiring Housing Dimensions (with lens) 5 -1/8" H x 5" W x 2 -3/4" D (130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Strobe Setting (see Note 2 below) 60 mA 94 mA 186 mA 252 mA Mount Reference RMS Currents 18 VDC 53 mA 84 mA 165 mA 224 mA at other voltages 24 VDC 40 mA 63 mA 124 mA 168 mA Housing Dimensions (with lens) 4 -3/4" L x 2- 5/16" W x 2 -5/8" D (121 mm x 75 mm x 67 mm) Ceiling Maximum RMS Rating per 15 cd 30 cd 75 cd 110 cd Strobe Settin g (see Note 2 below) 75 mA 125 mA 233 mA 316 mA Mount Reference RMS Currents 18 VDC 67 mA 111 mA 207 mA 281 mA at other voltages 24 VDC 50 mA 83 mA 155 mA 211 mA NOTES: 1. "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Heanng Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform ) `Installation Reference ,SurfacO or Semi' - Flush Wall Mounting 0 6 - Mounting is compatible with i p r I single gang, double gang, and 1 1 4" (102 mm) square boxes, 1 - 1/2" (38 mm) deep, by others iiiii �p1 a X01 _ 1 ,_ IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE i i Bottom of lens OHO I O either even 1 �� 'G 0i ` ' wit th, or slightly Electrical Wiring access hole I iO w —� , . I above bottom box outline ® 0111 of compatible i lli tt ■©e �III boxes Wiring terminals ■ Ik ` II 1 i '1 Mounting Holes: 11 • oung I 4" square (4) NFPA 72 requires 80" (2.03 m) ''''''""r' ® Single gang (2) that the entire lens minimum 41111PIP" fait Double gang (3) be not less than 80" and not greater than 96" above the finished floor Transparent housing (.........._.______________ and lens assembly Intensity selection ¢ I plug, accessible only fr. ® from rear of housing, IF II P E factory setting is 15 cd all Removable cover Strobe intensity (tool required) viewing slot 3 S4906- 0001 -3 5/2008