Specifications GAS PIPE CALCULATIONS GAS INPUT DELIVERY EQUIPMENT BTU PRESSURE F -1 66,000 2 LB. F -2 66,000 2 LB. F -3 66,000 2 LB. F-4 88,000 2 LB. TOTAL LOAD 286,000 LONGEST RUN 140' GAS PIPE SIZING BASED ON 2 LB. DELIVERY AT 150' SIZE MAX. CAPACITY 1" 668,000 a ( -- N N( N f% RECEIVED ...aratimumsi. RROA�1 IAC 01 2006 LaSalle CIT,�OTI ,A,�n CITY SPECIFICATION SHEET eUILDING DIVISION ' ' LOSONE SELECT® p /kl G�' ��I�'hyrr CEILING MOUNT VENTILATORS " " "`''''` i L400 L500 L700 SERIES r ' Incredibly reliable. Unbelievably quiet. Offering • Model 71V (Ivory) / 71W (White) 12 -Hour Time the CFM choices you need at the lowest sound Control levels in the Industry. • 6 -Amp, Electronic Variable Speed Controls FEATURES Model 72V/72W (120 VAC) • Model 423 Transition (4W x 18W to 10" round) GRILLE: • Model RD2 Radiation Damper • Conceals interior • Model LAF2 Grease Filter (for Models L400K & • Low profile styling blends with any decor L500K only) • Metal, finished with white painted enamel BLOWER: • Low RPM for quiet operation TYPICAL SPECIFICATION • Resilient anti - vibration mounts Ventilator shall be Broan Model L400, (L400K), (L500), • Balanced, polymeric, centrifugal blower wheel for quiet, efficient performance (Models L400K (L500K),(L700). _ & L500K - metal wheels) Ventilator shall have galvanized steel housing insulated • Permanently lubricated, thermally protected motor with at least 1/2" of acoustic insulation (with no insulation • Plug -in motor rated at 120 VAC - Models L400K & L500K). Housing to have adjustable • Designed for continuous operation mounting brackets. HOUSING: Automatic backdraft damper to be located within duct • Rugged, 20 gauge galvanized steel connector. Duct connector, blower assembly, and wiring • 4 x 18%2" duct connector plate shall be adjustable for either horizontal or vertical • 1/2" acoustic insulation inside (Models L400K & installation. Blower unit shall be removable from housing and will L500K - no insulation - for kitchen applications) • May be installed in ceiling or wall (size permitting) have a polymeric (metal - Models L400K & L500K), • 8- position mounting brackets for easy installation balanced centrifugal -type blower wheel. Motor to be and greater adaptability to various mounting permanently lubricated and mounted with resilient requirements anti- vibration mounts. RPM not to exceed number • Automatic backdraft damper located within duct listed for each model. connector Air delivery shall be no less and sound levels no greater • Factory- shipped in horizontal discharge position - than listed for each model. All air and sound ratings easily converted to vertical discharge shall be certified by AMCA. Units to be UL and cUL • May be installed as an in -line ventilator with addition listed. of accessory kit Model 982L (purchase separately) ACCESSORIES (purchase all separately): OffitC0 93roan- NuTone LLC certifies that ammo the • Model 57V (Ivory) / 57W (White) 3 amp Electronic models d,e A�ico Variable Speed Control The ratings shown are based on 41 6 1 11) • Model 59V (Ivory) / 59W (White) 60- Minute Time iaisc tests and Fedoras performed In accordance with AMCA Control Fr -, / ® Publication 211 (and AMCA Publication • Model 61V (Ivory) / 61W (White) 15- Minute Time rt :ETF,;; ce nd ° w i t h ;he Control ,,,, ° requirements of the AMCA 55/JCI IU If C : ACCESSORIES (continued): CewrredRatings Program' C (21 Broan - NuTone LLC, 926 West State Street, Hartford, Wisconsin 53027 (1- 800 -637 -1453) Broan - NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, L5T 1H9 (1- 888 -882 -7626) REFERENCE QTY. REMARKS Project 1 Location Architect Engineer Contractor Submitted by Date 20B 99042734C •.r PERFORMANCE RATINGS - LOSONE SELECT® CEILING MOUNT VENTILATORS AMCA LICENSED PERFORMANCE L'�00, L500 L700 SERIES CFM / SONES - AT STATIC PRESSURES (Ps - Inches of H2O) MODEL NOMINAL 0.0" .10" .125" .250" .375" .50" .625" .750" .875" 1.0" NOMINAL AMPS WATTS NO. VOLTAGE • Ps Ps Ps Ps Ps Ps Ps Ps Ps Ps RPM WO Hz "'Su L400 120 VAC CFM Hoc. 480 442 434 388 344 299 229 182 114 33 735 1.4 146 SONES Hor. 2.0 2.4 2.3 2.8 3.3 3.8 4.5 4.8 5.4 5.6 CFM Ver. 467 428 416 378 335 291 237 170 85 8 755 1.4 146 SONES Ver. 2.3 2.6 2.6 3.0 3.5 4.0 5.1 5.5 5.7 5.9 L400K 120 VAC CFM Hor. 442 415 406 370 330 274 230 191 130 50 675 1.4 146 SONES Hor. 2.9 3.2 3.3 3.8 4.4 5.3 6.0 6.5 6.8 7.2 CFM Ver. 440 409 399 358 294 246 203 157 102 28 680 1.4 146 SONES Ver. 2.9 3.4 3.3 4.0 5.0 6.1 6.3 6.8 7.1 7.2 L500 120 VAC CFM Hoc. 538 520 514 491 463 434 389 339 282 186 810 2.2 232 SONES Hor. 3.0 3.1 3.3 3.6 4.0 4.4 5.0 5.7 6.2 6.7 CFM Ver. 539 517 512 481 451 418 367 319 247 137 865 2.2 232 SONES Ver. 2.9 3.1 3.2 3.4 3.8 42 4.8 5.9 6.3 6.4 L500K 120 VAC CFM Hor. 506 484 481 460 435 418 389 337 301 231 700 2.2 232 SONES Hoc. 4.3 4.3 4.4 5.0 5.6 6.2 7.0 7.6 8.0 8.3 CFM Ver. 481 472 473 443 418 388 353 311 262 187 705 2.2 232 SONES Ver. 3.6 3.9 4.0 4.5 5.6 6.1 6.7 8.4 8.1 8.6 L700 120 VAC CFM Hof. 722 704 701 667 640 607 571 534 453 333 960 2.9 313 SONES Hor. 4.5 4.6 4.7 4.8 5.0 5.2 5.6 6.2 7.1 7.2 CFM Ver. 708 691 687 658 628 597 560 515 444 312 985 2.9 313 SONES Ver. 5.2 5.0 5.0 5.7 5.8 6.1 6.4 7.4 7.1 7.6 Performance ratings include the effects of inlet grille and backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan cones at 5' (1.5m) in a hemispherical free field calculated per AMCA Std. 301. Values shown are for Installation Type B: Free inlet fan sone levels. Performance shown is for installation Type B: Free inlet, Ducted outlet. anica - Broan- NuToneLLC certifies that the mod - CERTIFIED els shown herein are to bear the 1 1S , �� AMCA Seal. The ratings shown are based � t7 O� ' - on tests and d procedures performed in I accordance with AMCA Publication 211 0.90 (and AMCA Publication sound is \ �,� i EMI Ni& also certified) and comply y with with the is - ' iog of the AMCA Certified Rat- 0.80 ,'■,- ings Program.' m.' mo in (� movrmc,iir MO COMROIf assoc mioamnc 0.70 ( i u w 0.60 t 21 1 r ° � 1 � 1 21 r u9 0.50 < � m� � N , r o 4 U Q A''- I I W , & 0 0 G \ ct 0.40 / . i' v . - N 3 'r F- 0.20 I (1) 114 0.10 1 0.00 - I 1 � - v 0 80 160 240 320 400 480 560 640 720 ^ AIR FLOW RATE (CFM) / 2 3 � ' WEIGHT ✓ MODEL NO. SHIPPING WT. , L400 L500 33.8 lbs. L400K, L500K 36.2 lbs. L700 33.9 lbs. r 5.to i`'e ro °., .. k Broan NuTone LLC, 926 West State Street, Hartford, Wisconsin 53027 (1- 800 -637 -1453) c Broan NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, L5T 1H9 (1- 888 - 882 -7626) -If Submittal for: Totaline P474 -1050 Programmable Thermostat ECEIVED Y3s� o lti• CRY OF i Ju: rwid 72 3,13° �99L0 G DIVISION 70' O O 00 3.13" 0.88„ STANDARD FEATURES: • Auto Changeover, 2 -Stage Heat/2 -Stage Cool for use with gas /electrics, heat pumps, electric & hydronic heat. • Dual - Setpoint with adjustable deadband, setpoint adjustment range from 35° to 99° F, switchable to °C. • Programmable with up to 4 Time Periods per day, separate weekday and weekend programs. • Thermostat Locking - Set points can only be adjusted by authorized individuals if this feature is turned on. • Thermoglow Continuously Lit Electro- luminous Display. • Large number display, extremely easy to operate and program. • Configurable display can show both heating and cooling setpoints and room temperature simultaneously. • Maintains temperature to within 1° of setpoint. • All programming and setpoints stored in non - volatile memory, and are never lost in power failure. • Attractive ultra -white design. • Backplate available for replacement applications. • Red /Green LED shows whether thermostat is calling for Heating or Cooling. • 5 minute compressor time guard and adjustable cycle limit, both overrideable for servicing equipment. • Extremely simple to operate with extra large display and large, soft buttons. • Meets California Residential Title 24. MODEL:I P474 - 1050 I QUANTITY: I I DATE: I JOB NAME: LOCATION: BUYER: I I BUYER P.O. #: I ENGINEER: •� ;, T2sbm 5 8STA/STX; L' ' , ;,• ' z 4 Way Multipoise Induced Combustion S 1 [ , ,,- Gas Furnace m` zv �' �'Cll' E'1' Input \opacities - 1 5.000 tits u'1 5,5 000 BAih ' A - y }• s. •3 4 4, 5 - - - - Turn to the Expert , - ,, . .• j, Product Data a .k., `. A u THE CARRIER 58STA/STX GAS FURNACE The 58STA/STX 4 -way Multipoise rz.' cf=nt., c'_'■■., Gas Furnaces feature Carrier's eff7nnt ® QuieTechTM noise reduction system c for incredibly quiet induced draft D ® ®� operation. Applications are easy with ® ® 4 -way multipoise design, ' through - ® the- furnace downflow venting, ,13 dif- © ©� ferent venting options, and a door ® designed for easy service access. An © ©� ® inner blower door is provided for - ® ®� tighter sealing in sensitive applica- �� ® tions. The 5SSTA/STX furnaces are I © approved for use with natural or pro- i pane gas, and the 58STX is approved I i ! for use in Low NOx Air Management I j ! Districts. STANDARD FEATURES - h QuieTechTM system noise reduc- tion system - Microprocessor based control center RE GEIV ED LED diagno and self test feature rise Adjustable h air temperature ! rfl 8 V� �; ° 1 Adjustable cooling airflow p I Gi TY �� TIG�RD - 4 -way Multipoise furnace, 13 vent �'.3 }LUR� p, \1181°1\1 ! applications Compact design - only 33 -1/3 in. tall - Power HeatTM Igniter - Draft safeguard switch to ensure proper furnace venting ! - Inner door for tighter sealing - Hybrid HeatTM compatible \ \ - All models are chimney friendly \ I when used with accessory vent kit I ; - Twinning in Upflow, Downflow ' __ and Horizontal \ ` _ I _ ___ - Residential installations eligible for consumer financing through the Retail Credit Program A04039 LIMITED WARRANTY - 20 -year warranty on "Super STM" heat exchanger - 5 -year parts warranty on all other *.o, components • 0 . " , 0 t , _ , I (1) swap Fuse i (11/0e. .,, s ....... am. BEC-1 0 1 1/4 '''' • i/1 01 `�iy o ‘,7 1 1 . : 11 1 1 HEAT EXCHANGER CONTROL BOARD ' 1O INDUCER BLOWER l_ Model number nomenclature 58STA 045 100 08 Nominal Cooling Size (Airflow at .5 ESP) 58STA 4 -Way Multlpolse (400 CFM per 12,000 Btuh) 58STX Low NOx version 08 — 800 CFM 12 -1200 CFM 14 — 1400 CFM es-. 16— 1600 CFM 20 — 2000 CFM 22 — 2200 CFM Input Capacity 045 — 44,000 Btuh 110 — 110,000 Btuh -P 070 — 66,000 Btuh 135 — 132,000 Btuh -4 090 — 88,000 Btuh 155 — 154,000 Btuh Series Number 2 "• If - - Physical data 4 , $1 :01.t.17-3 erilis:74f fftleVE, OUTPUT CAPACITY BIM* 58STX Upflow; all 58STA 35,000 36,000 53,000 54,000 53,000 7 1000. - ,71.000 (NonweatherIzed ICS) t ' "58STX Downftow/Hortontal 34,000 34,000 51,000 51,000 :51,000 68000 „ 68,000 S8STX Upflow; all 58STA ' 44,000 44,000., , 68,000 66,000 66,000 8 0 00 9.- 1 .!.8 ,00 9 IN PUT trnni- 58STX Doinfiowitiorizontal 42,000 42,000 63.000 63,000 63,000 84;000 84,000 AFUEV Nomvoatterizad ICS 80.0 80.0 . - 80.0 80.0 80.0 80.0 . ' 80.0' SHIPPING WFJGHT (U3S.) CERTIFIED TEMP RISE RANGE rF) CERTIFIED EXT STATIC PRESSURE LIMIT CONTROL HEATING BLOWER CONTROL BURNERS (Monoport) Heating Cooling ting 104 107 111 115 126 127 140 30-60 20-50 40-70 30-60 25-55 40-70 30-60 0.10 0.10 0.12 0.12 0.12 0.15 0.15 0.50 0.50 0.50 0.50 0.50 0.50 0.50 AIRFLOW CFM* Hea 920 1250 720 1195 1450 1375 _ 1505 Cooling 845 1160 900 1200 1530 1385' 1720 SPST Solid-State Time Operation . 2 J 2 1 3 1 3 I 3 I 4 I 4 GAS CONNECTION SIZE 1/2-in. NPT GAS VALVE (Redundant) Manufacturer White-Rodgers Minimum Inlet Pressure (In. wc) 4.5 (Natural Gas) Maximum Inlet Pressure (In. we) 13.6 (Natural Gas) IGNITION DEVICE Hot Surface • Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 4 percent for each 1000 ft above sea level. Refer to National Fuel Gas code Table F4 or furnace Installation Instructions. In Canada, derate the unit 10 percent for elevations 2000 to 4500 ft above sea level. t Capacity in accordance with U.S. Government DOE test procedures. $ Airflow shown is for bottom only return-air supply. For air delivery above 1800 CFM, see Air Delivery Table for other options. A fitter is required for each return-air supply. An airflow reduction of up to 7 percent may occur when using a Carrier 4-W16 in. high efficiency media fitter. ICS - Isolated Combustion System Blower performance data .,:J.2-.. UNIT SIZE .'-':,;i- , -;s: 2 '.--" ',; , .:1 1 '.;. ,, ' - -'? . : , ' , . :- ':".. l• :. 08 'F!..., ,-,, 1::: ' .-.:; It- 12 ir - 16 ''. - 14 r::: 4716 ... DIRECT MOTOR Hp (PSC) 1/5 1/3 1/5 1/3 1/2 . 1/3 1/2 MOTOR FULL LOAD AMPS 2.9 5.2 2.9 5.2 7.9 5.2 7.9 RPM (Nominal) - Speeds 1075 1075 1075 1075-3 1075-3 1075-3 1075-3 BLOWER WHEEL DIAMETER x WIDTHS (IN.) 10x6 10x6 10x6 10 x 6 11 x 8 10 x 8 10x 10 ,-. 6 ... AIR DELIVERY —CF'M (With filter)* e1e .. r RETURN -AIR EXTERNAL STATIC PRESSURE (In. wc) 041.F SUPPLY SPEED 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 .'.... ?''? Bottom ' High 1085 1035 975 915 845 770 675 585 ' 0fi `•Q8= ` -' or :Med 920 875 830 770 710 640 555 440 250 195 • Side(s) • Med -Low 820 775 730 680 620 555 470 360 190 n( �,' - S Bottom .1_,- H• h • 1450 1375 1305 1225 1145 2' h 1050 .955 845 705 510 - 3 ` • ig 1360 1300 1240 1175 1115 1040 950 850 - 725. • .575 ;`- "°" Med -Low 1250 1210 1160 ! 100 1040 965 885 - 790 670. 520 "1 ' �. ~ ,i Bottom 'FfIgh 1030 1010 980 945 900 Or Med-High 835 815 845 775 680 490 335 ,r-f :`. Side(s) Med-Low 725 675 6 0 675 610 490 375 265 rfi� 700 645 675 555 475 390 300 5 39 t �_'•.`` ': � Bottom — , or High 1425 1375 1320 1265 •t+ 06 1125 1035 940 830 655 ,. '* Side(s) Med-Low 1200 1175 1145 1105 1050 1 990 920 840 905 790 620 X " �` Bottom 725 555 1805 1740 1670 1600 1530 1445 1360 1280 1180 1075 "�rr or Med igh 1630 1585 1530 1470 1405 1330 1255 1170 1080 990 g� .. -. ,;� - Side(s) Med -tow 1460 1420 1385 1325 1280 1220 1155 1080 995 - 910 ., '1; Bottom 1650 1600 1535 1465 •��?9Q -1 igh 1515 1485 1440 1380 1300 1220 1115 1990 830 645 t :, Side(s) Med -low 1385 1360 1320 1260 1195 1120 1025 915 710 5 B ottom r< 09D7,s Bottom High 2060 1985 1915 1820 1720 1610 1490 1340 1135 925 P 6 °= SideY6% or Med-H 1790 .1765 1715 1645 1560 1470 1345 1195 1010 820 () Med-Low 1505 1505 1480 1440 1375 1300 1190 1045 890 740 f *. .. 1 Bottom h 2405 2310 2220 2130 Med h 2225 2155 2080 2025 1920 1790 1660 1530 1350 �� " �;�'� Only Med -Low 1995 1895 1785 1675 1565 1420 1235 9;; :y 2020 1955 1880 1805 1730 >3 Y 1630 1535 1420 1275 1135 �_ ;� ' Both Sides or Med-High h 2530 2450 2365 2270 2165 2065 1940 1805 1670 1505 1 Side & Bottom ig 2285 2215 2150 2075 1985 1890 1780 1660 1525 1360 It , +± Med -Low 1995 1945 1900 1840 1770 1685 1600 1480 1350 1180 ' 1' ...?,;.1:', High 2300 2200 2090 1985 1865 1730 1585 1425 -- '' _: 1 S ide Only Med -High 2260 2190 2110 2035 1940 1845 1735 1620 1475 1325 :.'r Med -Low 1950 1910 1855 1795 1730 1650 1555 1445 1310 1150 "_ Bottom High 1625 1575 1515 1445 1355 1260 1165 990 785 .110- 12.-J: or Med -High 1510 1470 1415 1355 1285 1185 1070 890 725 - - Side(s) Med -Low 1360 1335 1295 1250 1180 1100 985 810 '` :71016,1° Bottom High 2035 1965 1880 1790 1680 1495 1365 1215 1075 875 g Med -High 1745 1710 1650 1560 1450 1340 1205 1090 955 750 _ `". ; :i 't: 1 Side Med -Low 1530 1515 1470 1400 1310 1215 1095 990 830 670 Bottom Med-High 2230 2205 2165 2110 2035 1950 1855 1740 1615 1485 High 2530 2470 2400 , 2320 2220 2115 .'`:- 2000 1865 1730 1590 ar, Med -Low 1920 1900 1880 1845 1795 1730 1650 1555 1460 1340 110-22 -: Both Sides or High — — 2415 2350 2250 2145 2015 1875 1715 1560 1 Side & Bottom Med -High 2235 2200 2155 2100 2040 1955 1850 1740 1595 1470 High 2540 2495 2430 2355 2265 2175 2065 1935 1785 1650 1 Side Only Med-High 2125 2120 2105 2060 2010 1940 1840 1730 1615 14.85 ..,,1 Med -Low 1790 1795 1790 1765 1720 1650 1585 1500 . :t:"'•''�-' . `r `' Bottom High 2090 2010 1930 1835 1710 1590 1470 1335 1025 835 :. : =° or Med -High 1790 1755 1705 1640 1550 1465 1360 1210 785 ~r..,. ". �' v 945 785 .;: .ii,k '' -;;;;- 1 Side Med -Low 1545 1525 1500 1450 1380 ,;, 1315 1215 1005 855 670 ; �: € 2.: � r Bottom High 2485 2400 2310 2215 2110 Med-High 1880 1725 1535 1355 ;<; Only Med 2195 2150 2090 2000 1920 1825 1720 1565 1405 1255 x � Med-Low 1880 1850 1820 : 1 1780 1715 1 " `il n 1635 1540 1415 1 ; .: � :; — 1290 1160 - >; z�:� - „: B oth Sides or High x : '; ;: 135=22 -�=r 2385 2305 2195 2085 1960 1825 1670 1465 E,f P-7 -q 1 Si & Bottom Med-High .- i �: T. igh 2180 2145 2060 2010 1945 1865 ,;;�3` ::.. 1765 1660 1515 1325 ` t..;::: ,. 1 Side Hi — 2135 2085 2035 1975 1895 1795 1685 1565 1445 1265 — 2245 2155 2055 1940 1825 1695 1555 1385 ;:' ?” - ;r ^ . Only Med-High -: °b ;lfi;E Med -Low 1880 1850 1820 1780 1715 1635 1540 1415 1290 1160 . ' High 2465 2430 2375 :1- vF ` } ; Bottom g 2305 2230 2110 2000 1865 1725 1545 r °.;u, Med -High 2115 2105 2075 2030 1980 1910 1830 1725 1590 1425 . :4,4. r Med-Low 1800 1790 1770 1735 1695 1840 1570 1465 1345 1225 i, , `,'" ,, ' ',,,: x:155 -20. ' h Sides Or High 2375 2285 2200 2105 1995 1870 1730 1570 °t- _;:: ; ;i 1 Side & Bottom Med -High 4 2155 2135 4 2095 4 2040 1975 1895 4 1790 1685 1550 1400 Hi h - 2260 2180 2085 1975 1865 1740 1605 1455 1 Side Only Med -High 2140 2095 2040 1975 1890 1810 1705 1595 1480 1325 ;.' Med -Low 1800 1790 1770 1735 1695 1640 1570 1465 1345 1225 A filter is required for each return-air supply. Airflow performance includes 1 in. washable filter media such as contained in factory- authorized accessory filter rack. To determine airflow performance without this filler, assume an additional .1 available external static pressure. — Indicates unstable operating conditions. 10 , • • - . . . . .. .._. _ • Dimensions ...7 0 „.______ , el3Tr . • _ .,: •.. _ 2 __________ ' T-ittlr a ' - A ., .. ... • Tenr JUNCTION SCR . LOCATION r • 0 —nor . -\ F -1 4-13 (167 OUTLET , • -----------' • v , 718 IRAN ACCESSORY i .7. ..... , $-7W III I:II ,.. 1/2 DIA IRERMOSTAT ..■.. =!=i=1= ilw fr OW RIGHT HAND WIRE ENTRY F. -. iii OAS ENTRY ' —=1--...S21—.= ' I ro=sr NY OLA. TNERMORTAT WIRE BORT F.7,,, , cn .. -... LEFT NANO GAS_ 1-Ter • BURY < - AL .- - 33-snr 1 344/Ir ' U), i I I CO i 1 i 14-7fir I 711" ov.. AccEssoey---, i y . , , l'r 3.3,.. , I Tor ouL Accessoey 1 Iduif -----------. „v ,.„ tor . L 5-112. L E I-1W 71-51e• ____I ,_11,.. -. . BOTTOM INLET 22-1/16' I WOE INLET (CASING) A03060 ;: VENT ..,•::il.... ••••• 9 m ::: -: ,2 _-,.. ,.;. .., VENT 1'..-.F'4:0' 74 kz. pv--, , A. - .1t,in:1:0:1=-:f-.W.;-g , Tk isf,:: ,- v.I . 14=e , cE7 ,,, , , 44: , ....,e ,, ,t , vt- - ,tri-,'F'2':-'.. '!". . 58STA/ST)( . CABINET .:. :i'...:7, SUPPLY.,'Wgr.: ; 5:11.PN -- ;r . .:4-1::1 , T0i 2 VENT = ',..4..1 '-, : -,.., ,, , .•.': - .1T1 , 11NIT SIZE '':::=12:4! -;. .111 Oti.Y;Y:1f-;: FpuRrt vgfrti 0140 pirrxgr '3i, . --- ;.(seti note l ili ''.... 045-08 14-3/16 12-9/16 12-11/16 9-5/16 4 045-12 14-3/16 12-9/16 12-11/16 9-5/16 4 070-08 14-3/16 12-9/16 12-11/16 9-5/16 4 –.0. 070-12 14-3/16 12-9/16 12-11/16 9-5/16 4 070-16 17-1/2 15-7/8 16-1/8 11-9/16 4 a. 090 17-1/2 15-7/8 16-1/8 11-9/16 . 4 090-16 21 19-3/8 19-1/2 13-5/16 4 090-20 21 19-3/8 19-1/2 13-5/16 4 110-12 . . 17-1/2 15-7/8 16-1/8 11-9/16 4 110.16 21 19-3/8 19-1/2 13-51/6 4 110 21 19-3/8 19-1/2 13-5/16 4 135 21 19-3/8 19-1/2 13-5/16 4 (note 1) 135-22 24-1/2 22-7/8 23 15-1/16 4 (note 1) 155-20 . 24-1/2 22-7/8 ' 23 15-1/16 4 (note 1) Notes: 1)135 and 155 size furnaces require 5-in. vents. Use a 4-5 in. vent adapter between furnace and vent stack. 2) See Installation Instructions for complete Installation requirements. • • ' � .INST ALLATION i t lama' ektes C LEARANCE 10 CORMJSTiLE _ ntsraNCE et PoucES Aux coa nacre comsusT®LES : • T dairfurnace`k'egtpedbrtreeMfh, 'Da tarnaoeIseapdredthrUPFL OVA Dpyg , 1Rpyy, an d natia pas et alBudes0-10000tt3.3,O50m. :. s, - rrooaao►rrnt_k �aeeo i ; ? , • ; An Y'" Ial, ` a :' t bY., fie dace btii>eescal ramrods parI filatuAdt" ihdlie ° tiledbb,caitvatbpopene' et le aalatondS�rvERSI,EHfr JrdVERSIE gas tree a ma y be reQtriled for Borne tuiral gag :. ° . , ` ' :.t.. ,,. trots ingoe kr -`}. a do tA §�ge„e,d • trots o not yt ' ; drer y � e baling ma y _ t i c nsbucted an !ice `. • - . - . llama aiatatan. - i , - .1lodertelon de biretta tta 1t LJT ace my be Instated al con rail:le ' - floorig In alcove or dose[ ai ante n deaanoe as Indlcalad by a 7: Tlda lrrgea be used vvRt e cal material ' --.t, may 1}pe &1 Vat aR art" s. 9t t E * • —I and may be warted h arnman wet other gas a E �t s E > fared applaices * oort � X Ce4eb1/neise A *Nat estOcutate - - f f „ e�N • par tll a avec gei nasal et &Vales LE comprises Utiliser une a 03,050m (0-10,000 pi), O t, :0 ^T� 7.'412- aE • n gm paflee four* s pa co' • _ V "" T labrlcarit Par Passer p * Q . 3 . - castings nstlalais au gr¢ natant. 0 • istakle clans tobtamastcau n* 11, Let1B buriaise pelt tee instable ar ° ara= n ( tndna aorriltl3�Ie dais U af se o0ve cu �n>rt ( Un p dais en garde-robe On respectart le minimum despace b des ns4isiau aombutt ies, t i Vert Mamma b comb 4etti4+d arle tieganme Far Snpe WO arab idles (6 pc). Cale burnaise pat etre aerduil de Asia avec �t de rev avec ( cartaai au candil arrrun d lautres apparels a gaz Par mrdrd d Areelat on A peril lope 8 po (6 Tidies} Par condrit icualon 11po(1not+). MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION DOWIFLOW PDSmoNS: t istla6txi al narcanbtedible Doors toy. For Insrata4on an oarbustble bang only when ratted an special base, Pat Na KGAS130201ALL, Cot Assembly, Pat Na CD5 arCK5, or Col Casing, Pal Na KCAKC. 0 18 nd,es front dearance segued for algae, * Indicates apply or re&en sides when mace is in the hart:tuts' position. Line aortal ady peke between fees fanned by ntersedors a the Tcp and Iwo Sides at the funaoe jade* aid bulag joists, studs or baring DEGAGEMENT MINIMUM EN POUCES AVEC ELEMENTS DE CONSTRUCTION COMBUSTIBLES POUR LA POSn10N COURANT DESCENDANT: t Par Installation str plaidwr non amtrstible satdernat Par Ilnstallaton srr to plandier carrutrsable setdenerrt quand on utise la base speckle, piece rf KGdS01AL1, Pasen6le serparb pace rf CDs ou CK5, cu le ter de somata Pace rf KCAKC. 0 Days the abhve, an dot meita r in d8gagemert a ravant de 18 pa (450nm). * La pcistion barcarole comma le del d'entres au de rear guard la bunaise est dais la martian horizontals. Is =fad nest pants quartile les fps bmndes pales it orsectiors du dessus et des deuce cedes de t dense de la farraise et les solves, mordant sacs cadre de dtarperde. ■ 327590 -101 REV. C , 0,iiiiimrt, ISO 9001:2000 w ` '° RATING NCY MEETS DOE RESIDENTIAL CONSERVATION l � CERTIFIED SERVICES PROGRAM STANDARDS. ��� ® m w,.ti• �� r �\ le C ; m Before purchasing this appliance, read important • t I F cr raise 0 energy cost and efficiency information available from your retailer. 12 Typical wiring schematic ..,,. _.':! .''''; "I° "! ':,.'-'!`!* 1. ..;2;,':.- .::-.,,'‘,.,'::•!*,..,... '''..--L..0" ..-,-',.,.. • -..::..-.., ,17 . ._ !:, _ ._ . . ........-....-,..-....—; - .. ' r • ---- FIELD 24-V WIRING . . _ ' ' • - ---- FIELD 115-, 208/230-, 460-V WIRING • ';'....:::,, ---., FACTORY 24-V WIRING ..., „ ,. _ ; ,,. - , , , - -- •-•-,,i,., 7,-.r 7--. - FACTORY115-V WIRING :...9 yiiRMObTAT . , . ' '; .'... ,....,. ; : .'''s. - , '..', '. ::::',..,1''-i' •-',FIVE .•, - -• i'::: 1 V t / w N•i , '=, ' ; : ',''' r'''' -",-;.. - ': : „.:' -.• , :,.: -I "-,VYTIB, ' '- -I :i -,, ' BLOVVER ' Tl - IREE-VVIRE,, — , ! • ! = -' ,:.-,' - ..''' '.".4. "Iliel" -- ', ,' DOOR - HEATING ' ' ' ' - •.' .: . . c'''ff'''Tft:Y -..• , 0......4 . 208/2'30- OR SWITCH 'ONLY' .-• : - ' , , - , •• Ac.""I-!fg"-- e,611''''' -- 46oN ' -ell • .._ e--1 1 1 vt ,,,,,,.:,,,,„,-., _-,,,,,,,.„,,, __ pHAsE • W -- •-- ---:- - -is---} 208/230-V - •• I--- - ----- G -:---- 7 4 1 _ 6ND ____ ___ _,_ __ ___ . 1 1 -- - SINGLE ' 0 _ .---- PHASE 115-V AUXILIARY , , • FIELD-SUPPUED J ri IC> " i 1 DISCONNECT CONTROL NOTE 1 1 1 - - CONDENSING ...: BOX C> -- -- UNIT 24-V TWO TERMINAL WIRE BLOCK FURNACE NOTES: 1. Connect Y-terminal as shown for proper operation. 2. Some thermostats require a "C" terminal connection as shown. 3 If any of the original wire, as supplied, must be replaced, use same type or equivalent wire. A02186 Electrical data ..,.,_.„..„,...i......„,„:-.2...„. .,,,,OppERA :iAltE-,;. ,,_,..,-,',2,.. , L. vAgi. , v; .: 1 4. 1 f• - ;• ,, k ,- ::, - 7. .i.".....-.. zi :' '-.‘ : .-j;•Crr Ill '.t1-7-41?:°: ''''' f. 4:L- .. ::4):::::' ' ' '' !. ' Cf ` : •t :7- : ikti , ' . ; -3.1 VoLTAGE RANGE'-AW '-'-':iiVir. i„i.:-,:i.:4,41IfikXIMUM '-g4 1 ,..Vii. ‘ i ... , :-/{1 - * - 0t.1 - 5-miiiii , ' - "'" ,:.-1, - ---- - .- .- - . . '.4., - 1 7' '' ' ' ' '.' ,' 7.iPUSE OR Claii4 MINIMUM '.• UNIT SIZE :. - ... , PHASE •-:-... ;:.11,40kbuin' - Mlnirntim!, " ?' 'Al' '' `: (FT)* 7 ":- SKR ANIPSf ';,''':: f GAGE . .. 045-08 115-60-1 127 104 5.4 49 15 14 045-12 115-60-1 127 104 r 7.0 39 15 14 070-08 115-60-1 127 104 5.0 52 15 14 --Ob. 070-12 115-60-1 127 ' 104 6.8 40 15 14 070-16 115-60-1 127 - 104 8.5 29 15 14 ...de. 090-14 115-60-1 127 104 8.2 34 15 14 090-16 115-60-1 127 104 10.0 28 . 15 14 090-20 115-60-1 127 104 13.8 32 20 12 110-12 115-60-1 127 104 8.2 34 15 14 110-16 115-60-1 127 . 104 10.1 28 15 14 110-22 115-60-1 127 104 14.8 30 20 12 135-16 115-60-1 127 104 10.2 27 15 14 135-22 115-60-1 127 104 14.4 30 20 12 _ 155-20 115-60-1 ' 127 104 15.0 29 20 12 . , ' Permissible limits of the voltage range at which unit operates satisfactorily. f Time-delay type is recommended. # Length shown is as measured one way along wire path between unit and service panel for maximum 2 percent voltage drop. .,. - • _ _ • . . .. T • cal q Ty p i cal installation . ,._ CONDENSING , ( MIT , 11111,1111111.,. 11%\- 1 111111111.1 1 El:}E Ilil i f 111-rre-sim --4.0.---mella:111 IER 11111 1.1 -- -- ,.. , - i. , ....- 1 mariaabwil 1 11111100.11111) ___ ----E---...-. -___ - --------,---L 0 1 -.2...-.:f.... , 1 D-----C 110 Oil \<° 11.3}1-2-. 1 0111 GAS-FIRED WATER HEATER ELECTRONIC ---------- -----___Z I AIR CLEANER AIRFLOW f> A02184 . , *.• - .• 14 . REQUIRED OUTDOOR VENTILATION AIR IN ACCORDANCE WITH TABLE 403.3 2004 . OMSC UNIT AREA SQUARE PEOPLE NUMBER OF 1/2 OCCUPANT O.S.A. CFM PER MIN. SERVED FOOTAGE PER 1000 SQ -FT PEOPLE LOAD PER SEC. 403.3 CFM / SQFT PERSON O.S.A. CFM F -1 OFFICE 130 7 1 0.455 -- 20 9 OFFICE 176 7 1 0.616 -- 20 12 STORAGE 720 0.15 54 TOTAL 75 F -2 WOMEN'S 367 188 MEN'S 277 113 OFFICE 230 7 2 0.805 -- 20 16 TOTAL 317 F -3 KITCHEN 216 20 4 2.16 -- 15 32 MEN'S 188 75 WOMEN'S 188 113 , BREAK ROOM 140 7 1 0.49 -- 20 10 BREAK RR 80 38 TOTAL 268 F -4 OFFICE / RECEPTION 597 7 4 2.0895 -- 20 42 RR 50 38 TOTAL 80 TOTAL -- 3359 -- 13 -- -- -- 741 CI / , ` ni L O b c c C3 1 41071/ 4 ° oSene e lee' ' SPECIFICATION SHEET LOSONE SELECT' 14 \ J FIL ING MOUNT VENTILAT ®RS R `� K' C \ L100 SERIES L150 SERIES Incredibly reliable. Unbelievably quiet. Offering the CFM TYPICAL SPECIFICATION choices you need at the lowest sound levels in the industry. Ventilator shall be Broan Model L100, (L100MG), (L150), (L150MG). FEATURES Ventilator shall have galvanized steel housing insulated with GRILLE: at least 1/2" of acoustic insulation. Housing to have adjustable • Conceals interior mounting brackets. • Low profile styling blends with any decor Automatic backdraft damper to be located within duct • White polymeric ( "MG" models - metal, finished with connector. Duct connector, blower assembly and wiring plate white painted enamel) shall be adjustable for either horizontal or vertical installation. BLOWER: Blower unit shall be removable from housing and will have a • Low RPM for quiet operation polymeric, dynamically balanced centrifugal-type blower wheel. Motor to be permanently lubricated and mounted with • Resilient anti- vibration mounts resilient anti - vibration mounts. RPM not to exceed number • Dynamically- balanced, polymeric, centrifugal blower listed for each model. wheel for quiet, efficient performance Air delivery shall be no less and sound levels no greater than • Permanently lubricated, thermally protected motor listed for each model. All air and sound ratings shall be • Plug-in motor rated at 120 VAC certified by AMCA. Units to be UL and cUL listed. • Designed for continuous operation HOUSING: • Rugged, 20 gauge galvanized steel • 6" round duct connector Qft1CG -Broan- NuTone LLC certifies that • 1/2" acoustic insulation inside CERTIFIED the models shown herein are to bear the AMCA Seal. • May be installed in ceiling or wall (size permitting) The ratings shown are based on mono tests and procedures performed • 8- position mounting brackets for easy installation and in accordance with AMCA greater adaptability to various mounting requirements ■ ,. + Publication 211 (and AMCA u'as)vVt Publication 311 if sound is also • Automatic backdraft damper located within duct connector mw,�,. d , certified) and comply with the • Factory- shipped in horizontal discharge position - easily requirements of the AMCA a Certified Ratings Program" converted to vertical discharge • May be installed as an in -line ventilator with addition of accessory kit Model 961L (see "Accessories ") ACCESSORIES (purchase all separately): • Model 57V (Ivory)/ 57W (White) Electronic Variable Speed ()- Control • Model 59V (Ivory) / 59W (White) 60- Minute Time Control • Model 61V (Ivory) / 61W (White) 15- Minute Time Control UL listed for use over • Model 71V (Ivory) / 71W (White) 12 -Hour Time Control bathtubs and showers when • Electronic Variable Speed Controls — Model 72V (120 VAC) connected to a GFCI- • Model 961 L In -line Adapter Plate protected branch circuit. • Model RD1 Radiation Damper Broan - NuTone LLC, 926 West State Street, Hartford, Wisconsin 53027 (1- 800 - 637 -1453) Broan - NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, L5T 1H9 (1- 888- 882 -7626) REFERENCE QTY. REMARKS Project Location Architect Engineer Contractor Submitted by Date • 500 99042731E PERFORMANCE RATINGS - LOSONE SELECT® CEILING MOUNT VENTILATORS AMCA LICENSED PERFORMANCE I' 100 SERIES & L150 SERIES CFM / SONES - AT STATIC PRESSURES (Ps - inches of H MODEL NOMINAL 0.0" .10" .125" .250" .375" .50" .625" .750" .875" 1.0" NOMINAL AMPS WATTS NO. VOLTAGE Ps Ps Ps Ps Ps Ps Ps Ps Ps Ps RPM 45)60 Hz L100 120 VAC CFM Hor. 136 115 109 93 80 65 44 12 SONES Hor. 0.5 0.8 0.9 1.3 1.8 2.3 3.0 3.2 640 1.1 87 CFM Ver. 138 117 112 94 80 67 46 13 SONES Ver. 0.7 0.9 1.0 1.3 1.8 2.2 2.8 3.0 650 1.1 87 L100MG 120 VAC CFM Hor. 144 121 115 97 83 68 46 12 SONES Hor. 0.5 0.8 0.9 1.2 1.8 2.4 3.0 3.3 630 1.1 87 CFM Ver. 142 119 115 95 80 67 45 13 �6 SONES Ver. 0.5 0.8 0.9 1.4 1.8 2.3 2.9 3.1 640 1.1 87 L150 120 VAC CFM Hor. 181 161 157 141 132 124 114 94 62 SONES Hor. 1.3 1.4 1.5 2.2 2.6 3.1 3.6 4.1 4.6 710 1.3 100 CFM Ver. 179 163 160 149 142 133 122 105 73 23 750 1.3 100 SONES Ver. 1.4 1.6 1.6 2.0 2.5 3.0 3.3 3.6 3.9 4.2 L150MG 120 VAC CFM Hor. 184 165 161 148 141 135 126 108 74 19 710 1.3 100 SONES Hor. 1.1 1.4 1.4 1.9 2.3 2.8 3.2 3.8 4.1 4.5 CFM Ver. 183 165 162 151 143 135 124 107 76 26 725 1.3 100 SONES Ver. 1.4 1.6 1.6 2.0 2.5 3.0 3.3 3.6 4.0 4.4 Performance ratings include the effects of inlet grille and backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5' (1.5m) in a hemispherical free field calculated per AMCA Std. 301. Values shown are for Installation Type B. Free inlet fan sone levels. Performance shown is for Installation Type B: Free inlet, Ducted outlet. (MCA 'Broan - NuTone LLC certifies that 1.00 1 CERTIFIED the models shown herein are li- 0.90 I RSTYIGS censed to bear the AMCA Seal. The ratings shown are based on 7 /011410 tests and procedures performed in c ki 0.80 ��1 �� accordance with AMCA Publica- ma i °•;'"- " tion 211 (and AMCA Publication 0.70 � 7� - S movimtnr 311 if sound is also certified) and UL listed for use over ? D D COf1tROle RS:ocmnoa.me^ g connected to a GFCI- 6 comply with the requirements of bathtubs and showers when �' RlI - the AMCA Certified Ratings Pro- a: 0 ��. ) gram.' protected branch circuit. e a 0.50 Cl) plO 4cf � 4- - I Z 2 0.30 ea \ \ Q CO '� I- 0.20 CO 3 1 8 \ \ 0`10 14 0.00 I , 4 0 20 40 60 80 100 120 140 160 180 200 Y ssi POLYMERIC GRILLE AIR FLOW RATE (CFM) MODELS METAL GRILLE L100 MODELS L150 WEIGHT /�� II l i, �\ r � / �� �:;;� �4 L100MG MODEL NO. SHIPPING WT. ice � � I l r �� L150MG L100 !%,, -. � _ 22.8 lbs. �' L100MG 23.71bs. L150 23.1 lbs. ° L150MG 23.71bs. Broan - NuTone LLC, 926 West State Street, Hartford, Wisconsin 53027 (1 -800- 637 -1453) ` ' k '.. ® `Ri. 'Ii; Broan- NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, L5T 1H9 (1- 888 -882 -7626) m F mi 2 I SWIM ® CITY OF TIGARD SPECIFICATION SHEET dxUjLDING DML'1S1ON L ®S ®NE SELECT' �' \ ; 1 I J s .4 . , v, , C CEILING MOUNTVENTILAT VENTILATORS ,, . \ Y " 00 L2 � '� & L300KIMIG SERIES /, „.5, , , I�ES � � �, 0 Incredibly reliable. Unbelievably quiet. Offering the CFM TYPICAL SPECIFICATION choices you need at the lowest sound levels in the industry. Ventilator shall be Broan Model L200, (L200MG), (L250), (L250MG), (L300), (L300MG) or (L300KMG). FEATURES Ventilator shall have galvanized steel housing insulated GRILLE: with at least 1/2" (12.7 mm) of acoustic insulation (with no •Conceals interior insulation - Model L300KMG). Housing to have adjustable • Low profile styling blends with any decor mounting brackets. damper to be located within du • White polymeric ( "MG" models metal, finished with Automatic back draft duct white painted enamel) connector. Duct connector, blower assembly and wiring plate shall be adjustable for either horizontal or vertical BLOWER: installation. • Low RPM for quiet operation Blower unit shall be removable from housing and will have • Resilient anti - vibration mounts a polymeric, dynamically balanced centrifugal -type blower I • Dynamically - balanced, polymeric, centrifugal blower wheel wheel. Motor to be permanently lubricated and mounted with for quiet, efficient performance (Model L300KMG - metal resilient anti-vibration mounts. RPM not to exceed number wheel) listed for each model. • Permanently lubricated, thermally protected motor Air delivery shall be no less and sound levels no greater than • Plug -in motor rated at 120 VAC listed for each model. All air and sound ratings shall be • Designed for continuous operation certified by AMCA. Units to be UL and cUL listed. HOUSING: 'Broan - NuTone EEC certifies that • Rugged, 20 gauge galvanized steel ' be �fioar�sea • 8" (203.2 mm) round duct connector ` mcechxeAMCASeal . accuduigs shown are based on tests and • 1/2" (12.7 mm) acoustic insulation inside (Model L300KMG °fDC� �ce`^� ed'nacoordarce no insulation -for kitchen applications) with AMCA Publication 211 (and ,f i AMCA Pfie 3 11 l sound the • May be installed in ceiling or wall (size permitting) A alsocertried) and ahtn • 8- position mounting brackets for easy installation and �° ° "°°"'' requirements a"eAMCACA Ce'sed aro cower; 1P0r Rati s Pr r greater adaptability to various mounting requirements " °` "'p"° "9 am' • Automatic back draft damper located within duct connector • Factory- shipped in horizontal discharge position - easily converted to vertical discharge • May be installed as an in -line ventilator with addition of accessory kit Model 981L (see "Accessories ") C ( ' Broan - NuTone LLC, Hartford, Wisconsin, U.S.A. 53027 Broan - NuTone Canada Inc., Mississauga, Ontario, Canada L5T 1H9 REFERENCE QTY. REMARKS Project Location Architect Engineer Contractor Submitted by Date -�— *PRODUCT SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE . PERFORMANCE RATINGS - LOSONE SELECT® CEILING MOUNT VENTILATORS L200, L250, L300 L300KMG SERIES - AMCA LICENSED PERFORMANCE CFM (L /s) SONES AT STATIC PRESSURE [Ps In. (mm) of water] MODEL NOMINAL 0.0 0.1 0.125 0.250 0.375 0.50 0.825 0.750 0.875 1.0 NOMINAL AMPS NUMBER VOLTAGE O,O ( ) (2.5) (3.2) (8.4) (9.5) (12.7) (15.9) (19.0) (22.2) (25.4) RPM a 60 Hz VV4TTS CFM Hor. 231 214 210 196 186 177 165 144 113 51 (109.2) (101.0) (99.1) (92.5) (87.8) (83.5) (77.9) (68.0) (53.3) (24.1) 740 1.8 127 SONES Hor. 1.8 1.8 1.7 2.3 2.9 L200 120 VAC 3.5 4 .1 4.9 5.3 5.3 CFM Ver. 224 210 207 197 187 179 167 144 99 41 (105.7) (99.1) (97.7) (93.0) (88.3) (84.5) (78.8) (68.0) (48.7) (19.4) 760 1.8 127 SONES Ver. 1.5 1.8 2.0 2.3 2.7 3.4 ' 4.0 4.5 5.1 5.2 CFM Hor. 237 218 215 199 190 180 187 144 108 47 (111.9) (102.9) (101.5) (93.9) (89.7) (85.0) (78.8) (88.0) (51.0) (22.2) 715 1.8 127 L200MG 120 VAC SONES Hor. 1.4 1.8 1.9 2.4 3.0 3.6 4.2 5.1 5.8 5.5 CFM Ver. 228 213 209 198 190 182 188 145 105 56 SONES Ver. (101.5 7.6) (100.5) (98.6) (93.4) (89.7) (85.9) (79.3) (68.4) (49.6) (26.4) 730 1.8 127 1.7 1.8 2.3 2.8 3.4 4.1 4.8 5.1 5.2 CFM Hor. 272 281 259 250 242 233 218 201 185 99 (128.4) (123.2) (122.2) (118.0) (114.2) (110.0) (102.9) (94.9) (77.9) (46.7) 830 2.1 166 SONES Hor. 2.1 2.3 2.2 2.9 3.3 3.9 4.4 4.8 5.5 ..1* L250 120 VAC 5 8 CFM Ver. 269 261 259 253 248 239 224 203 171 101 (127.0) (123.2) (122.2) (119.4) (117.0) (112.8) (105.7) (95.8) (80.7) , (47.7) 880 2.1 186 SONES Ver. 2.3 2.6 2.7 3.0 3.3 3.7 4.2 4.7 5.4 280 267 265 254 246 5.6 CFM Hor. 238 224 203 171 101 805 2.1 166 (132.1) (126.0) (125.1) (119.9) (116.1) (112.3)_ (105.7) (95.8) (80.7) (47.7) SONES Hor. 2.1 2.5 2.5 2.9 3.4 3.9 L250MG 120 VAC 4.3 4.6 5,6 5.9 CFM Ver. 275 283 262 255 250 241 229 210 178 105 (129.8) (124.1) (123.7) (120.3) (118.0) (113.7) (108.1)_ .(99.1) (84.0) (49 830 2.1 166 SONES Ver. 2.2 2.6 2.7 3.0 3.4 3.8 4.3 4.8 5.5 5.8 CFM Hor. 312 309 308 303 296 287 273 254 219 125 (147.2) (145.8) (145.4) (143.0) (139.7) (135.4) (128.8) (119.9) (103.4) (59.0) 905 2.6 212 L300 120 VAC SONES Hor. 2.8 2.9 2.9 3.3 3.5 3.9 4.3 4.7 5.1 5.6 • CFM Ver. 319 314 313 306 299 288 274 251 219 120 (150.6) (148.2) (147.7) (144.4) (141.1) (135.9) (129.3) (118.5) (103.4) (58.6) 940 2.6 212 SONES Ver. 2.6 2.9 3.0 3.4 3.6 3.9 4.4 4.7 5.0 5.5 CFM Hor. 323 317 316 312 305 298 283 268 235 153 (152.4) (149.6) (149.1) (147.2) (143.9) (140.8) (133.6) (125.5) (110.9) (72.2) 860 2.6 212 SONES Hor. 3.0 2.8 3.0 3 2 3 5 3 g L300MG 120 VAC 4.3 4.8 5.2 5.7 CFM Ver. 322 315 314 308 302 292 278 259 227 119 (152.0) (148.7) (148.2) (145.4) (142.5) (137.8) (131.2) (122.2) (107.1) (58.2) 885 2.6 212 SONES Ver. 2.4 2.7 2.8 3.3 3.5 3.9 4.3 4.7 5.1 5.5 CFM Hor. 286 279 277 272 268 261 253 241 222 ,173 (135.0) (131.7) (130.7) (128.4) (128.5) (123.2) (119.4) (113.7) (104.8) (81.6) 790 2.6 212 SONES Hor. 2.8 3.0 3.1 3.4 3.8 L300KMG 120 VAC 4.4 4.8 5.1 5.5 6.1 CFM Ver. 287 280 277 273 266 259 247 231 208 164 (135.4) (132.1) (130.7) (128.8) (125.5) (122.5) (118.6) (109.0) (98.2) (77.4) 815 2.6 212 SONES Ver. 3.3 3.8 3.7 4.1 4.7 5.2 5.8 6.3 6.8 Performance ratings include the effects of inlet grille and back draft damper in the air stream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5' (1.5 m) in a hemispherical free field calculated per AMCA Std. 301. Values shown are for Installation Type B: Free inlet fan sone levels. Performance shown is for Installation Type B: Free Inlet, Ducted outlet. * PRODUCT SPECIFICATIONS SUBJECT TO CHANGE VNTHOUT NOTICE • , mls __ L e ® si l SPECIFICATION SHEET LOSONE SELECT® CEILING MOUNT VENTILATORS L200, L250, L300 & L300KMG SERIES AMC. "groan- NuTone LLC certifies that the CERTIRED R models shown herein are licensed to 165.2 350 bear the AMCA Seal. The ratings shown lOWlO are based on tests and procedures Performed in accordance with AMCA Publication 211 (and AMCA Publication 141.6 300 - L 300 Emilomme L3p0M a r 311 if sound is also certified) and , m otir rm a roconmot, n co with the requirements of the - 300K G assoa:an.igc. AMCA Certified Ratings Program." 118.0 250 _ _ � u € -....ii .ill ,\ 94.4 !L 200 \G sx 8" (203.2 mm) U , , ROUNDDUCT 12 1/4" F H �2pp ?� �MG CONNECTOR (311.2 mm) I (311.2 ` mm) 70.8 X 150 ' ■ 4 ■ NO 1.4-../ } . ■I ' , � ' 47.2 X 100 I Q 11 3/4" �� .xf i 23.6 50 \ 1r (298.4 mm) I =:.` 0 0 i 0 0.1 0.13 0.25 0.38 0.5 0.63 0.75 0.88 1 / STATIC PRESSURE [in. WG.] �� s / 0 2.5 3.3 6.4 9.7 12.7 16.0 19.0 22.4 25.4 SS�� STATIC PRESSURE [mm WG.] POLYMERICGRILLE MODELS 14 " 14" L200, L250 (355.6 mm) (355.6 mm) & L300 WEIGHT 4. � MODEL SHIPPING WT. 0 w:` j / " L200 23.0 lbs. (10.4 kg) L250 0 23.1 lbs. (10.5 kg) L300 23.1 lbs. (10.5 kg) METAL GRILLEMODELS L200MG 23.9 lbs. (10.8 kg) L200MG, L250MG, 14" 14" L300MG & (355.6 mm -- - L250MG & L300MG 24.0 lbs. (10.9 kg) , L300KMG (355.6 mm ) ( 355 L300KMG . i ii. 25.2 lbs. (11.4 kg) � icy {i: .. r , ;!i 1 r. a:,:rr :ra: :i-ec •c.: ,. :r,a•,: - ••1:1•Jit.t. :t : i: : } ® a ` PRODUCT SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE BR, SPECIFICATION SHEET MODEL 684 , Hh CEILING ALL EA IV Da: 01 2006 CITY OF TIGARD RI III r ?N(; DIVISION Dependable, high performance bathroom TYPICAL SPECIFICATION ventilation. FEATURES Ventilator shall be Broan Model 684. GRILLE: Unit shall have galvanized steel housing with dual • Attractive grille conceals interior integral mounting brackets. It shall be ducted to a roof • Matte white polymeric — blends well with any decor or wall cap. • Torsion spring grille mounting — no tools required Blower assembly shall be removable and have a • White, metal grille kit available (purchase sepa- centrifugal blower wheel and permanently lubricated rately) motor. BLOWER: Air delivery shall be no less and sound level no • Plug -in, permanently lubricated motor greater than valves listed in the "Performance Ratings" • Centrifugal blower wheel charts on this sheet. Air and sound ratings shall HOUSING: be certified by HVI and AMCA licensed. • Rugged, 26 -gage galvanized steel construction Unit shall be U.L. Listed for use over bathtubs and • Sturdy key -holed mounting brackets for quick, showers when connected to a GFCI protected branch accurate installation circuit. • Tapered, polymeric duct fitting with built -in backdraft damper for easy, positive duct connection and no metallic clatter mica model Broan-NuTone LLC re certifies that the CERMO models shown herein are licensed to Model 2687H & 3687H: Rough -in housings for 2684E RAMOS bear the AMCA Seal. The ratings shown are based on tests and proce- finish assemblies (packed 4 per carton). 3687H Jolpro AMC performed in accordance with housings include slide channels and mounting �M AMCA Publication 211 and AMCA brackets. g Publication 311 and comply wilt, the " requirements of the AMCA Certified nrw conraa, Ratings Program aS50c IPi1011: inc U.L. Listed for use over tubs and showers when connected to a GFCI protected branch circuit -21 OD HV O CERTIFIED Broan NuTone LLC, 926 West State Street, Hartford, WI 53027 (1- 800 -637 -1453) REFERENCE QTY. REMARKS Project Location Architect Engineer Contractor Submitted by Date • PERFORMANCE RATINGS - MODEL 684 AMCA LICENSED PERFORMANCE Model 1 .Static Pressure (in. wg Ps) Total Nominal Duct No. 0.0 1 0.1 I .125 1 .250 I .375 Volts Watts RPM Size 684 CFM 89 89 87 . 77 59 Sones 2.7 3.2 3.3 3.6 3.9 120 1280 4' Round The performance ratings include the effects of inlet grille and backdraft damper in the airstream. of test. The sound ratings are loudness values In fan sones at 5 (1.5m) in a hemispherical Speed (RPM) shown is nominal. d 31 Values shown is are on actual speed B: Free inlet fan sone levels. Air eehnrical fr field calculated per AMCA Std. 301. Values sflown are for Installation Type P performance shown is for Installation Type B: Free inlet, Ducted outlet. SONES AMPS ® "ICC/ Broan-N u Tone LLC certifies that the PERTIREO els shown herein Model HVI Sones AMCA Sones MODEL a bear the AMCA Seal ratin gs Number a 0.1" Ps* (O.0" Ps* NUMBER AMPS route cedures are based on tests and pro - 684 2.5 2.7 684. I 0.5 Performed in accordance ' C with AMCA Publication 211 and • There is difference between sone values certified by HVI for residential use Vi ire the '®°°'° AMCA Publication 311 and comply and by AMCA for commerciaVndusfrial use. Exact comparison of these n sc E with of the AMCA =corm/mi.: Certified Ratings Program. values is not possible. This difference is mainly due to procedures used to asocra,ion m convert measured sound to perceived sound. ANSI S3.4, used by both HVI and AMCA, specifies a procedure for calculating loudness as perceived by a typical listener under specific conditions. HVI establishes values at a 0.50 - distance of 5 feet from the fan in a 'spherical free field•. AMCA establishes values at a distance of 5 feet In a'hemispherical free field'. HVI and AMCA have different rules for rounding sone values. 0.45 _ 0.40 • HVI PERFORMANCE z 0.35 MODEL NUMBER SONES CFM X0.1" Ps • 684 2.5 j 80 Q W 0.30 ® x', HVI -2100 CERTIFIED RATINGS comply with new 0.25 testing technologies and procedures prescribed by , ,x#21 ' .0 ; 0, Y; w the Home Ventilating Institute, for off - the -shelf W 0.20 e�. l products, as they are available to consumers. ( �< Product performance is rated at 0.1 in. static a- r- r i 'r 1 pressure, based on tests conducted in AMCA's 0 0.15 CERTIFIED state-of-the-art test laboratory. Sones are a measure of humanly-perceived loudness, based on Laboratory measurements. F¢ -- 0.10 - WEIGHT .� 8 '� I 0.05 ■ 4 0.00 MODEL NO. 1 SHIPPING WT. 684 8.0 Ibs. 0 10 20 30 40 50 60 70 80 90 100 AIR FLOW RATE (CFM) - 0 _ I . 5w.A . •, .., LP r 5 /^ ` 1 dos �� ® L f .,.., " � . li Broan - NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453) , � ,