Loading...
Permit C ITY OF TI G BUILDING PERMIT PERMIT #: BUP2005 -00366 l ,1k DEVELOPMENT SERVICES DATE ISSUED: 8/9/2005 �� II 13125 SW Hall Blvd., Tigard, OR 97223 503 - 639 -4171 PARCEL: 2S 112BC -07800 SITE ADDRESS: 08101 SW CAROLE CT ZONING: R -4.5 SUBDIVISION: RAZE MEADOWS LOT: 001 JURISDICTION: TIG Project Description: Replacing window with door. REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: ALT FIRST: sf N: S: E: W: TYPE OF USE: SF SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 5N : sf N: S: E: W: OCCUPANCY GRP: R3 TOTAL AREA: 0 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED: STOR: HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: SMOK DET:Y DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : HNDICP ACC: BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING: VALUE: $ 2,300.00 Owner: Contractor: LAURA LORD ECC REMODELING & CONSTRUCTION, LLC 8101 SW CAROLE CT 16919 LAKERIDGE DR TIGARD, OR 97224 LAKE OSWEGO, OR 97034 Phone: 503 - 670 -4646 Phone: 503 - 806 -5177 Reg #: FEES Description Date Amount REQUIRED ITEMS AND REPORTS [BUILD] Permit Fee 8/2/2005 $72.10 [TAX] 8% State Surchari 8/2/2005 $5.77 [BUPPLN] Pln Rv 8/2/2005 $46.87 Total $124.74 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling 503-246_,.699 or 1- 800 - 332 -2344. may,,, Issued By!�_ _ ' _ JO / Permittee Signatur '" ' ,-� '�Gj� . L i Call 503 - 639 -4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. EC EOV D �� • Building Permit Application FOROFFICE US - . i d .1 City of Tigard �� ' 2 2005 Received D 0 /705 Permit No.76 , 13125 SW Hall Blvd., Tigard, OR 97223 Plan Revie Phone: 503.639.4171 Fax: 503.598.19 ., OF TIGARL7 4:r..,o- w r a1, Date /B : k (/ Q U Other Permit: Inspection Line: 503.639.4175 ■ =`f �� Date Ready/By: v , _ r )u ® See Attached Checklist for Internet: www.ci.tigard.or.us BUILDING DIVISION �� - Notified/Method: , a ) I Supplemental Information \f tO V∎• \ e.a- ''''Z ct. M..q—/ TYPE OF WORK DATA:."-.AND DATA:.-.AND 2- FAMILY DWELLING • ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all Addition /alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CO N_STRUCTION, work indicated on this application. ,f- and 2 -family dwelling El Commercial /industrial Valuation: $ Z v ❑ Accessory building ID Multi-family Number of bedrooms: El Master builder El Other: Number of bathrooms: - JOB SITE INFORMATION. AND LOCATION - • Total number of floors: Job site address: ei d) S IN C,t! RCL,E Gcoa'r New dwelling area: square feet City /State /ZIP: "'nC -a 1 cr.,E. 9 - 7 224 Garage /carport area: square feet Suite/bldg. /apt. no.: Project name: itotto Covered porch area: square feet Cross street /directions to job site: 'r 1 - x - 4 rz,, D Deck area: square feet Other structure area: square feet REQUIRED DATA:,COMMERCIAL -USE CHECKLIST Subdivision: Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK . work indicated on this application. LAGI■ J / W l 1n) / g u Di tv6 Valuation: $ T0_ Existing building area: square feet � New building area: square feet ❑ PROPERTY OWNER ❑ TENANT Number of stories: Name: L.. ,d A. 'LC _.€ Type of construction: Address: g-.-16 1 S AJ C.z, Cr Occupancy groups: City/State/ZIP: T c.a,D 1 olaz 1 2Z 4 Existing: Phone: J C20 — .4-e 4-c,,,. Fax: ( ) New: ❑ APPLICANT ❑ CONTACT PERSON . NOTICE • Business name: All contractors and subcontractors are required to be Contact name: licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: jurisdiction in which work is being performed. If the City /State /ZIP: applicant is exempt from licensing, the following reasons apply: P ma. . Phone: ( ) Fax:: ( ) I, 4 b • I E -mail: T 5. - 1 - 7-- CONTRACTOR / `a4+ f , r, Business name: E Cc ge, ALA A1® QV t us_ us_ BUILDING PERMIT FEES* ' Address: 16,1 1") LAK.E2I D6c pa_ l Please refer to fee schedule. City /State /ZIP: LI E, OSVNJEtaab Ce- ° W 34 Fees due upon application Phone: (,jl &Ob • St1-7 Fax: ) S34 - L33 Amount received CCB lic.: llo�„�64-2 e, — s f� Date received: Authorized signature: r_-)f /2 This permit application expires if a permit is not obtained �' .pie /-2,105-- within 180 days after it has been accepted as complete. Print name:T Dec �(� Date: * Fee methodology set by Tri- County Building Industry F Service Board. i:\ Building \Permits \BUP- PernitApp.doc 12/03 440- 4613T( I I /02 /COM /WEB) One- and Two - Family Dwelling ., Building Permit Application Checklist FOR OFFICE USE oNL\- City of Tigard Received Permit No.: Date/By 13125 SW Hall Blvd., Tigard, OR 97223 Associated permits: Phone: 503.639.4171 Fax: 503.598.1960 / 4 s JD M'�I �r'�' +'' ❑ Electrical ❑Plumbing ❑ Mechanical 24 - Hour Inspection Line: 503.639.4175 . I Internet: www.ci.tigard.or.us ❑ Other. THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Yes No N'iA 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ ❑ ❑ 2 Zoning. Flood plain, solar balance points, seismic soils designation, historic district, etc. ❑ ❑ ❑ 3 Verification of approved plat/lot. ❑ ❑ ❑ 4 Fire district a r r royal re r uired. Name of district: ❑ ❑ ❑-' 5 Septic system permit or authorization for remodel. Existing system capacity ❑ ❑ ❑ 6 Sewer permit. ❑ ❑ ❑ 7 Water district approval. ❑ ❑ ❑ 8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ ❑ ❑ 9 Erosion control ❑ plan ❑ permit required. Include drainage -way protection, silt fence design and location of catch- ❑ ❑ ❑ basin protection, etc. 10 3 Complete sets of legible plans. Must be drawn to scale, showing conformance to. applicable local, and state ❑ _ ❑ ❑ building codes. Lateral design details and connections must be incorporated into the plans, �r on a separate full -siz ' • . ' sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. _ 1 1 Site /plot plan drawn to scale. The plan must show lot and building setback dimension's; property corner elevations (if ❑ ❑ ❑ there is more than a 4 -ft. elevation differential, plan must show contour lines at 2 -ft. intervals); location of easements and driveway; footprint of structure (including decks); location of wells /septic systems; utility locations; direction indicator; lot area building coverage area; percentage of coverage; impervious area; existing structures on site; and surface drainage. 12 Foundation plan. Show dimensions, anchor bolts, any hold -downs and reinforcing pads, connection details, vent size ❑ ❑ ❑ and location. 13 Floor plans. Show all dimensions, room identification, window size, location of smoke detectors, water heater, ❑ ❑ ❑ furnace, ventilation fans, plumbing fixtures, balconies and decks 30 inches above grade, etc. , 14 Cross section(s) and details. Show all framing- member sizes and spacing such as flair beams, headers, joists, sub- O ❑' ❑ floor, wall construction, roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing, roofing, roof slope, ceiling height, siding material, footings and foundation, stairs, fireplace construction, thermal insulation, etc. 15 Elevation views. Provide elevations for new construction; minimum of two elevations for additions and remodels. ❑ ❑ ❑ Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope:-, , Full -size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing (prescriptive path) and /or lateral analysis plans. Must indicate details and locations; for•hon- • ' .❑ ❑' ❑ prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor /roof framing. Provide plans for all floors /roof assemblies, indicating member sizing, spacing, and bearing • ❑ , ❑ ❑ locations. Show attic ventilation. • . 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ ❑ ❑ systems, see item 22, "Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ ❑ over 10 feet long and/or any beam /joist carrying a non - uniform load. 20 Manufactured floor /roof truss design details. ❑ • ❑ ❑ 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas- piping schematic is required ❑ ❑ ❑ for four or more appliances. 22 Engineer's calculations. When required or provided, (i.e., shear wall, roof truss) shall be stamped by an engineer or ❑ ❑ ❑ architect licensed in Ore. on and shall be shown to be .1' livable to the .ro'ect under review. .IURISDIC'TIONAL SPECIFICS 23 Five (5) site plans are required for Item 11 above. Site plans must be 8 -1/2" x 11" or 11" x 17 ". ❑ ❑ ❑ 24 Two (2) sets each are required f o r Items 16, 19, 20 and.22 a b o v e. . . . . . . , .. . ❑ ❑ ❑ 25 Building plans shall not contain red lines or tape -ons. "Mirro"red" building plans will' 'not be 'accepted. ' ' ' ' ❑ ❑ ❑ 26 "Reversed" building plans must meet criteria outlined in the Permit & System Development Fees document.. ' i . . • ❑ ❑ ' ❑ 27 "Drawn to scale" indicates standard architect or engineer scale. o ❑ . ❑ ❑ 28 Site plan to include tree size, type and location per approved project, street tree plan and City of Tigard ' ❑ ❑ ❑ Street Tree List. t • 29 Site plan to include tree protection measures as required by conditions of approval. .❑ ❑ ❑ 30 A Clean Water Services' Sensitive Area Pre - Screening Site Assessment form is required for all building additions, — ❑ ❑ including decks, patio covers (over non - impervious surface) and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. - I:\ uilding \Permits\BUP- RES- PermitApp.doc 2 B • t'r 1 I ,,_ . kr .. : , 4 ( - - - i . , : ./7 I Approved plans 1. •, . i 6.& c ii".):/Aff: .1 shall be on job site. t i . AddS shall be posted , s: , f , I and visible from street. , . . , I , , • 0f;LE .Ittie- siQD RECENED t .: , . BUILDING DIVISION i• J,,, I, ,1 i I 1 , ,., ;1 s i .. , • , otdrt- g tt '''F' IN---16 ro •; INALL. '''S f , Ex , J 4 :'• 11 1 !1 . ....---L 1 , ----- 7.717.772:: -- 1 — =:— --- A4 t• L\ • 44----.-----1. 45 0 .0 . . . A y 0 . , I L • INTF.R.444, CONViLrir: SLAS ...) , \ , EK.k C LIAM ; .,..:. e. , . CITY OF TIGARD ) .• APProved ( 3y Approved . ( ): ,.. i_. . . '.. '-i.1-;,.v,,,L - , ... ,t,.... , -, . - : •. 4.A FOr only me work es described in -: • 4.... ' - --, •,,,. - -- - , ... ' ,,, .-„, t, *— 7-,,,,,:::. - ,,Lrnc , ' ,.-- ,..„, :,:, - ,; • • A , PERMIT NO. ..... .,......_,...._.,.....______ . , .... , 1- • -, „...,....„ See Letter to: Fotiod . ( ): ,,,, ,...., ,,, a - 3; ii (A Attach ( ): A • Job Address,: ii1......i. By: Ail A if Date: 5 C \ CSCTI cN 1 __A r l)...012-1:) OFFICE COPY A ./T e ....- i —...■ CITY OF TIGAEa BUILDING DIVISION PERMIT #: BUP2005.00386 I 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 8/9/2005 Phone: (503) 639 -4171 4,, All II fil Inspection Requests (24 Hrs.): (503) 639 -4175 INSPECTION WORKSHEET FOR DATE: 8/29/2006 TIME: 7.13AM PAGE: 88 SITE ADDRESS: 08101 SW CAROLE CT CLASS OF WORK: SUBDIVISION: RAZE MEADOWS LOT #: 001 TYPE OF USE: PROJECT NAME: LORD DESCRIPTION: Replacing window with door. OWNER: LORD, LAURA PHONE #: 503 - 67114646 CONTRACTOR: ECC REMODELING & CONSTRUCTION, LLC PHONE #: 503806 1 Inspection Request Scheduled For: Date: 8/29/2005 Pour Time: Code # Inspection Description Confirm # Contact # Message 299 Final inspection 014436 -01 503. 806 -5177 V Corrections /Comments /Instructions: I I PASS PARTIAL APPROVAL ❑ CANCEL Il NO ACCESS I I FAIL ALL FOR INSPECTION, U ADDITIONAL FEES ASSESSED Inspector: Date: 8 9 Phone #: (503) 718-