Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
CITY OF TIGARD BUILDING PERMIT COMMUNITY DEVELOPMENT Permit #: BUP2011 -00195 TIGARD 13125 SW Hall Blvd , Tigard OR 97223 503.718.2439 Date Issued: 09/16/2011 Parcel: 2S103DA04400 Jurisdiction: Tigard Site address: 10630 SW PARK ST Project: Noles Subdivision: FANTASY HILL Lot: 3 Project Description: Installation of solar photovoltaic system Contractor: IMAGINE ENERGY LLC Owner: NOLES, DAVID R AND 439 N BROADWAY MARGARET L PORTLAND, OR 97213 10630 SW PARK ST TIGARD, OR 97223 PHONE 503 - 477 -9585 PHONE: 503 - 620 -7553 FAX. 503 - 477 -8340 FEES Specifics: Description Date Amount Type of Use: SF Solar Photovoltaic System 09/13/2011 $180 00 Class of Work: ALT 12% State Surcharge - Building 09/13/2011 $21 60 Dwelling Units: 0 Info Process /Archiving - Sm Sheet (up to 09/13/2011 $1 50 Stories: 0 Height: 0 ft 11x17) Bedrooms: 0 Bathrooms: 0 Value: $0 Floor Areas: Total Area. 0 Accessory Struct: 0 Basement. 0 Carport 0 Covered Porch' 0 Deck 0 Garage 0 Mezzanine: 0 Total $203 10 Required: Required Items and Reports (Conditions) Fire Sprinkler. Parapet: Fire Alarm: Protected Corridors: Smoke Detectors Manual Pull Stations: Accessible Parking 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law All work will be done in accordance with approved plans This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center Those rules are set forth in OAR 952 - 001 -0010 through OAR 952- 001 -0090 You may obtain a copy of the rules or direct questions to OUNC by calling 503 232 1987 or 1 800 332.2344 Issued By: Permittee Signature: /tall . , 9.4175 by 7:00 a.m. for the next available inspection date. This permit card sha 1 De ept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. RECEIV 9/i54 £u1 oa /95 SEP 13 2011 /44 AY:, . io..WIEm CITY OFTIGARD Air / J XY: q /6 r/i I. Obcz. LI 71,V TYPE OF WORM 111 DIVISION Number of bedrooms: New construction Demolition Number of bathrooms. Addition /alteration/replacemeni- Other: Total number of floors: CATEGORY OF CONSTRUCTION New dwelling area: square feet 1 - and 2- fam d welling Commercial /industrial Garage /carport area. square feet Accessory building Multi - family Covered porch area: square feet Master builder Other: Deck area: square feet JOB SITE INFORMATION AND LOCATION Other structure area: square feet Job site address: 10630 SW Park St City/State/ZIP: Tigard, OR 97223 REQUIRED DATA: COMMERCIAL -USE CHECKLIST Permit fees* are based on the value of the work performed. Suite/bldg. /apt. no.: 'Project name: Noles 3.24 kW Solar PV System Indicate the value (rounded to the nearest dollar) of all Cross street/directions to job site: equipment, materials, labor, overhead, and the profit for the work indicated on this application. Valuation: $ Existing building area: square feet Subdivision: 'Lot no.: New building area: square feet 'Tax map /parcel no.: Number of stories: DESCRIPTION OF WORK — 3.24 kW Solar Photovoltaic System Type of construction: Occupancy groups: Existing: PROPERTY OWNER TENANT New: Name: David Noles BUILDING PERMIT FEES* (Please refer to fee schedule) Address: 10630 SW Park St Structural plan review fee (or deposit): City/State /ZIP: Tigard, OR 97223 FLS plan review fee (if applicable): Phone: (503) 620 -7553 Fax: ( ) Total fees due upon application: APPLICANT CONTACT PERSON Amount received: Business name: /.14 G fit{ r 1=t�1 /E./1< Y PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Contact name: 'T''2 -1. fT 4 'Li C rx) Let V Commercial and residential prescriptive installation of Address: roof -top mounted PhotoVoltaic Solar Panel System. Submit two (2) sets of roof plan with connection details City/State /ZIP: and fire department access, along with the 2010 Oregon Phone: (6/:3 g(j 3 _ 7 y y9 'Fax: : ( ) Solar Installation Specialty Code checklist. Permit Fee (includes plan review E- mail: -f . COQ 1 U l ►tit Qt 1 n,e, e n e.o% it . A-6 and administrative fees): $180.00 v CONTRACTOR Q U State surcharge (12% of permit fee): $21.60 Business name: Imagine Energy, LLC Total fee due upon application: $201.60 Address: 439 N Broadway This permit application expires if a permit is not obtained City /State /ZIP: Portland, OR 97213 within 180 days after it has been accepted as complete. * Fee methodology set by Tri- County Building Industry Phone: (503) 477 -9585 Fax: (503) 477 -8340 Service Board. CCB lic.: 167963 Authorized signature: 0._.._ ...,„ Print name: Jonathan Cohen 'Date: 9/1/11 REQUIRED DATA: 1- AND 2- FAMILY DWELLING Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the work indicated on this application. Valuation: $ $6,739.20 I: \Building\Permits\BUP- RESPermitApp.doc 02/ 24/2011 440- 4613T(11/02 /COM/WEB) - RECEIVED SEP132011 ° CITY or TIGARD BUILDING DIVISION N _, t 1' 011 ,,t: I - - PROPERTY LINE - - - SETBACK LINE - >-* L w Y T-. v w A Z a w Q' O 2 J W 00 LL W Q 'n MQ � Oz / Q z� 2 M §' O�Q . a _ a z u INVERTER LOCATED NEXT TO PANEL w u _ Ill w m i 0 ce Z 3 ATTACHMENTS SHALL BE SPACED NO I, , w GREATER THAN 24 INCHES ON CENTER i / N L J I I Q / / / / w (n EDGE. HIP, EAVE OR RID o w J 0 2 , oo s . z c - , a W OSISC 305.4.3 (B) o 3NQ W,o; Di 84 %TSRF Z "c n go°� o ' P V ARRAY COVERS LESS THAN 25% OF ROOF AREA; U N v u Q o EXEMPT FROM PATHWAY REQUIREMENT o o ° co o 5 i CITY OF TIGARD ARRAY SPECIFICATIONS ROOF SPECIFICATIONS Approved ... C ��� „.. ,••• ( (18) SUNTECH 180W PV MODULES ARCH COMP Conditionally Approved [ ] SMA SUNNY BOY 3000US INVERTER 1 LAYER CONERGY SUNTOP RACKING See Letter to: Follow [ ] 18° TILT 5YEARS OLD A ° hed 1 Z f= M L 180° AZIMUTH 18 PITCH �� Q � Z w oi 180° ORIENTATION PennitN .ben CL m �� `_ 4 TOF = 0 96 Add.- -. r r kI/ �r w Z o TSRF = 0.84 By: .�arl Date: to OFFICE COPY r t . STRUCTURE SPECIFICATIONS MOUNTING SPECIFICATIONS 2 "x4" RAFTERS, 24" O.0 CONERGY SUNTOP RACKING a _,i, 1/2" SHEATHING SLOTTED, EXTRUDED FRAME RAIL ROOF SPECIFICATIONS FASTJACK MOUNT W/ FLASHING 5 /16"x 3" STAINLESS STEEL LAG SCREWS ENGINEERED TRUSS CONSTRUCTION } 1 LAYER ARCH COMP C7 H r 2z 5 YEARS OLD r 1— \ W I0 u. w 0 z Q m B m Z a o M a Q am t� OZ mgr2 '4�4 v 2 zc)o o m < _ _ _ ____ _______ ___ __ ______ ______ ______ ____ T \ _ v Oa a o v - ___ = === 2' -7 3/4 " 3 - _= ____ _ _ � _ __ ______ ___ _ _ _ ____ ___ ____4_6__ _ EAST ELEVATION ____ _ — 4444 _ W _ _ - - -- -__-_- ALE: 1/16" = 1' ®Q - MODULE CLAMPS -- 0 ® _ \ w r i -- - -- - -- -- 4' -0" W, o O 3 0 g d l 4 4 4 4 _ - _ --- / —I [ a ; a Z on p N a Se • N --- -- ON ` 1 > ,54c4 K irov u uAwaumSECTIO AA w z— MW o o N A - - 4 4 == A ° W W 444 -_ -- _ _� N 4 1============r' 4 ___ _ — - . \ 1 L 2'-0" s ' o° z B / / Z M 1- N ° a O PARTIAL ROOF PLAN SECTION B -B D m 1 2, z S CALE: 3/4" = 1' 0 Q • WIRE SIZING SPECIFICATIONS DC INPUT: 5 4A, 140', 1.56x SAFETY FACTOR, 1.5% LOSS ALLOWABLE: 716' ON #10 CU AC INPUT: 12.5A, 20', 1.25x SAFETY FACTOR, 1.5% LOSS ALLOWABLE: 232' ON #10 CU } W W Mz n W r h. a c. A W o0 a w Z <6...0 Z M Q - - I I 1 O P L7 p.2 • __ - -.__ _ - I M 2 J D O m 1 11 I 1 I #10 C U RHW -2 IN 3/4" EMT CONDUIT 'ONLY POSITIVE CONDUCTOR SHOWN 111 N 3.24kW PV ARRAY (18) SUNTECH 180W PV MODULES w O 2 STRINGS OF 9 MODULES 0 a L, N Z De E Lu z R 1 ' 7 'N 6 8 Cr 4 Z ^ M kD g,4 1.n W w2 8o3 = J O <Z n N O, O W O OL 4 'O„ a < 0W � 70' Z �M 0 .- F- 8 Isc SMA 3000US BOTTOM LEFT 240 VAC INVERTER OF PANEL 6 d Q a , \ �� z � Z o C ETO METER o ' CO I ••=0 TO GRID c- _ / 200A AC PANEL D 20A, 2 -POLE BREAKER 4- #10 CONDUCTORS 0 10 J W M 38A, 600 VDC o DI U �9 m 2 Cit of Tigard III �' � SEp13 If Building Division C 2 0i ;~ 13125 SW Hall Blvd, Tigard, OR 97223 Bjjj D GD GAJ Phone: 503.718.2439 Fax: 503.598.1960 IV j$10� • T I GA R D Inspection Line: 503.639.4175 www.tigard- or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof - Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 10630 SW Park St City: Tigard Zip: 97223 Owner's Name: David Noles Date: 9/2/11 Contractor's Name: Imagine Energy, LLC CCB #: 167963 Design Parameters of the Property /Structure If "Yes ", does not Is the installation Y eS qualify for the Flood Hazard Located in a flood ❑ prescriptive path, follow Area plain/flood way? p N OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure © Yes If "Yes ", qualifies for "C" or less? ❑ N the prescriptive path. Installations on detached Is the Ground Snow single /two- family Load 70 psf or less? dwelling/single /two- If "Yes ", qualifies for family townhomes © Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If "Yes ", qualifies for structures other than ❑ Yes the prescriptive path. above ❑ No 1 I: /Building/ Forms /Photo Voltaic - Checklist. docx Is the construction material wood and does Yes If "Yes", qualifies for Type of Construction the construction qualify ❑ No the prescriptive path. as "conventional light frame" construction? Is the spacing 24 inches or less? © Yes If "Yes ", qualifies for Pre - engineered trusses. the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If "Yes ", qualifies for ❑ Yes the prescriptive path. ❑ No Is the combined weight © Yes of the PV modules and If "Yes ", qualifies for racking less than or El No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance © Yes If "Yes", qualifies for with Section 305.4(3) of ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is one Roofing Check the type of ❑ of wood of the three types material roofing material shingle /shake checked, qualifies for • Max. two layers the prescriptive path. © of composition shingle. Is the roof mounted p Yes Connections of solar assembly If "Yes ", qualifies for • the solar assembly connected to roof ❑ No to the roof framing or blocking the prescriptive path. directly? 2 I: Building / Forms /Photo Voltaic- Checklist.docx ❑ Yes If "Yes ", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If "Yes ", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If "Yes ", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inche Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum #10 at 24 inches o /c? Size and spacing of El Yes If "Yes ", qualifies for fastener? the prescriptive path. ❑ No Is the roof decking of WSP min. `` /2" thickness, ❑ Yes decking connected to If "Yes ", qualifies for framing members ❑ No the prescriptive path. w /min. 8d nails @ 6 "/12" o /c? Is the height less than or Maximum 18 inches equal to 18 inches? • Height of the from the top of the If "Yes ", qualifies for solar modules module to the roof © Yes the prescriptive path. surface. ❑ No 3 1: Building / Forms /Photo Voltaic- Checklist.docx • Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: SunTech Power Model Number: STP180S Listing Agency: UL 4 I: /Building/Forms /Photo Volta ic- Checklist, docx