Permit ., CITY OF TIGARD MECHANICAL PERMIT
111111 ` COMMUNITY DEVELOPMEN Permit #: MEC2011 -00417
13125 SW Hall Blvd., Tigard OR 97223 503.718 2439 Date Issued: 09/16/2011
T j'rA RD Parcel: 2S 110DCO2300
Jurisdiction: Tigard
Site address: 11535 SW DURHAM RD C -2
Project: Willowbrook Subdivision: 1998 -128 PARTITION PLAT Lot: 1
Project Description: Replace existing 5 ton heat pump split system, like for like
Contractor: REITMEIER MECHANICAL Owner: HIP WILLOWBROOK LLC
19570 SW 90TH CT BY HARSCH INVESTMENT CORP
TUALATIN, OR 97062 PO BOX 2708
PORTLAND, OR 97208
PHONE: 503 - 603 -0205 PHONE.
FAX: 503 - 603 -0150
FEES
Specifics: Description Date Amount
Type of Use: COM Permit Fee 09/16/2011 $269.03
Class of Work: ALT Type of Const: Plan Review 09/16/2011 $67 26
Occupancy Grp: Occupancy Load: 1 2% State Surcharge - Mechanical 09/16/2011 $32 28
Stories:
Info Process /Archiving - Sm Sheet (up to 09/16/2011 $3 00
11x17)
Project Valuation: $7,135.00
Fuel Air Handlers
Fuel Types: Units < 10000 cfm: 1
Gas Pressure Units > 10000 cfm•
Furnaces Boilers & Compressors
Furnaces < 100K BTU: 0 -3 HP
Furnaces >= 100K BTU. 3 -15 HP
Floor Furnaces: 15 -30 HP
Unit Heaters 30 -50 HP:
Vents w/o Appliances 50 or Greater HP
Air Conditioning 1
Heat Pump
Appliances
Vent Fans: Vent Systems: Total $371.57
Hoods Comm Incinerators:
Woodstoves. Gas Fireplaces: Required Items and Reports (Conditions)
Clothes Dryers Other Mech Units -
Gas Outlets: Other Desc.
Duct Work.
Fire /Smoke Dampers
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR Specialty Codes and all other
applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of
issuance, or if work is suspended for more the 180 days ATTENTION• Oregon law requires you to follow the rules adopted by the Oregon
Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0090 You may obtain a copy of the rules
or direct questions to OUNC by calling 503 232.1987 or 1 800.332 2344
Issued By: "40 Permittee Signature: "
Call 503.639.4175 by 7:00 a.m. for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
. ., . .
. . •
Mechanical Permit Ai • lie . 4a .9 EivED F
. OFFICE USE. ONLY - • - :., .-
_ .
City of Tigard Received
b-- -,.y/
q 13125 SW Hall Blvd., Tigard, OR 97223, - Permit No. fr120// - 2
5 1 6 2011 Date/By- t /V,/ a3X1--
Plan Review -
:111 M ' Phone. 503.718.2439 Fax. 503.598.1960 Date/By
T I Q A RD Other Permit
Inspection Line: 503.639.4175 ow oFTIGARD
: Date Ready/By Juns 0 See Page 2 for
AD
Internet: www.tigard NG DIVISIM Notified/Method. ell .. ...
6 Supplemental Information
W
9I it::11:::: #0,'"i , OF vv.:61i ' : -:: '
, 0* 1 0 4 :94100'Y:*4TitC-fu:s*010:40 - ii,
Mechanical permit fees* are based on the value of the work
0 New construction E Addition/alteration/replacement performed Indicate the value (rounded to the nearest dollar) of all
0 Demolition 0 Other: mechanical materials, equipment, labor, overhead, and profit.
Value: $ 7,135
IP .' "-' : ': tATTEGOROF C61111111&16N33.
, a: „&, -::. ,,,„:; : , .. ,- . --;, „. ,,,,,, .-,- , . , ,,, ,. , - - .':v tagy**10:*
0 1- and 2-family dwelling Z Commercial/industrial 0 Accessory building For special information use checklist.
0 Multi-family D Master builder 0 Other: Description Qty. Ea Total
f H n
Job site address:..111 Durham Road //52 (requires site plan showing placement) 46.75
Fumace 100,000 BTU (ducts/vents) 46.75
City/State/ZIP: Tigard, Or. 97223
Furnace 100,000+ BTU (ducts/vents) 54 91
Suite/bldg./apt. no.: C - 2 Project name: Willowbrook Heat pump
(requires site plan showing placement) 61 06
Cross street/directions to job site: SW 99 & SW Durham Duct work 23.32
Hydronic hot water system 23.32
Residential boiler (radiator or
hydronic) 23 32
Unit heaters (fuel-type, not electric),
in-wall, in-duct, suspended, etc. 46 75
Flue/vent for any of above 23 32
Subdivision: Lot no.:
Other 23 32
Tax map/parcel no.: Other fuel appliances:
s,t,,;,,,-, :i_,-?,.:-:,,, -;,--_-, - i :: Water heater 23.32
Gas fireplace 33.39
Replace existing 5 ton Heat Pump split system like for like.
Flue vent for water heater or gas
( LESS 5 riz / 0, tar7J fireplace 23.32
Log lighter (gas) 23.32
/ A-fr— Wood/pellet stove 33.39
Wood fireplace/insert 23.32
PROPERTY oWNFI'llic..-- ‘ '' --- '0 7 -- , 1% - z‘t '' Chimney/liner/flue/vent 23.32
..---- ."'<-=-, i;'' . ', ,:,..,;.. :.'.. . =. :: ' ,--::-=, ,-- ' - ' Other: 23.32
Name: Harsch Investments Environmental exhaust and ventilation:
Address: 1121 SW Salmon Range hood/other kitchen
equipment 33 39
City/State/ZIP: Portland, Or. 97205 Clothes dryer exhaust 33.39
Single-duct exhaust (bathrooms,
Phone: ( ) Fax: ( ) toilet compartments, utility rooms) 23.32
rt84,,E1;., T7Ft , l;' K Attic/crawlspace fans 23 32
Other: 23 32
Business name: Retimeier Mechancial
Fuel piping:
Contact name: Bob Cleveland $14.15 for first four; $4.03 for each additional
Address: 19570 SW 90 Court Furnace, etc.
Gas heat pump
City/State/ZIP: Tualatin, Or. 97062 Wall/suspended/unit heater
Phone: (503) 603 Fax: : (503) 603 Water heater
Fireplace
E bob.cleveland@reitmeiermechanical.c
Range
l, ,,1,14E dIAC9NTilACifliR 7 ..:1.'1Vril' ' '71Pri7 Barbecue
Clothes dryer (gas)
Business name: same as above
Other:
Address: :' 11
City/State/ZIP. Subtotal
Minimum permit fee ($90 00)
Phone: ( ) Fax: ( )
Plan review (25% of permit fee)
4.--C -613
lie. / 5' $ - 770 State surcharge (12% of permit fee)
TOTAL PERMIT FEE 37/ , .5'7
Authorized signature: ..... _ . __ . A__
This permit application expires if a permit is not obtained within 180
Z.,..c_ e ..„
days after it has been accepted as complete.
Print name . i e t )6 ti I
L
1/4.../ev eAck.0 Date: CI / I 6 (z. i 1 * Fee methodology set by Tn-County Building Industry Service Board
I \ Building \Permits \ MEC-PenrutApp doe 09/09/10 440-4617T (11/02/COM/WEB)
- yoRK
TABULAR DATA SHEET PI -
Outdoor Split System Heat Pump 1.5 Thru 5 Tons
MODELS: YHJD18* THRU 60
13 SEER - R -410A, 1 PHASE
Physical and Electrical Data
MODEL YHJD18 YHJD24 YHJD30 YHJD36 YHJD42 YHJD48 YHJD60
S41S2 S41S4 S41S4 S41S4 S41S4 S41S4 S41S4
Unit Supply Voltage 208 -230V, 10, 60Hz
Normal Voltage Range 1 187 to 252
Minimum Circuit Ampacity 11 9 11.2 14 1 19.7 20.9 25.6 34 9
Max. Overcurrent Device Amps 2 20 15 20 30 35 45 60
Min Overcurrent Device Amps 3 15 15 15 20 25 30 35
Compressor Type Scroll Recip Recip Recip Recip Recip Scroll
Compressor Rated Load 9 0 8 3 10.6 14 7 15.7 19 4 26.9
Amps Locked Rotor 48 0 43 0 54 0 74 0 88 0 88.0 135.0
Crankcase Heater No Yes Yes Yes Yes Yes No
Factory External Discharge Muffler Yes No No No No No Yes
Factory External Check Valve No No No No No No No
HS Kit Required with TXV 4 No Yes Yes Yes Yes Yes* No
Fan Motor Amps Rated Load 0 70 0 80 0 80 1 3 1 3 1.3 1.3
Fan Diameter Inches 24 24 24 24 24 24 24
Rated HP 1/10 1/8 1/8 1/4 1/4 1/4 1/4
Fan Motor Nominal RPM 825 1075 1075 850 850 850 850
Nominal CFM 2000 2900 3000 3800 3800 3600 3600
Face Area Sq. Ft 15 7 18 3 21 0 23 6 23 6 23 6 23 6
Coil Rows Deep 1 1 1 1 1 2 2
Fin / Inches 22 22 22 22 22 18 18
Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Vapor Line Set OD (Field Installed) 3/4 3/4 3/4 3/4 7/8 7/8 7/8
Unit Charge(Lbs. -Oz) 6 -6 9 -6 9 -0 10 -0 9 -10 14 -2 13 -13
Charge Per Foot, Oz. 0.62 0.62 0.62 0 62 0 67 0 67 0.67
Operating Weight Lbs 172 194 206 218 218 285 284
* These models are shipped with a Hard Start Kit installed at the factory
1. Rated in accordance with ANSI /AHRI Standard 110 -2002, utilization range "A ".
2 Dual element fuses or HACR circuit breaker Maximum allowable overcurrent protection
3. Dual element fuses or HACR circuit breaker Minimum recommended overcurrent protection .
4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model
5. The Unit Charge is correct for the outdoor unit, matched indoor coil, and 15 feet of refrigerant tubing For tubing lengths other than 15 feet, add
or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value
All dimensions are in inches They are subject to change without notice
Certified dimensions will be provided upon request
C
i ' . " - . ; Dimensions Refrigerant Connection
i �5�_.. , Unit (Inches) Service Valve Size
�t `_� Model
�r � Al B C Liquid Vapor
+ r 18 28 34 34
.. 24 32 34 34
A `` " 30 36 34 34 3/4"
',..r,!:: \ r /.ice
�+ r:/— + : 36 40 34 34 3/8"
:+c�� �iiA 42 40 34 34
\ r /rim
�� \
_-1--- �� .--r------- 48 40 34 34 7/8"
----...__ ! g 60 40 34 34
1. Including Fan Guard.
Johnson Controls Unitary Products 697441 -YTD -A -0911
SUBMITTAL DATA SHEET . Fa YORK
SINGLE PIECE AIR HANDLER Heating and Air Conditioning
SPLIT - SYSTEM COIL
MODELS: MA / MC
JOB NAME: LOCATION:
PURCHASER: ORDER NO:
ENGINEER:
SUBMITTED TO: FOR: REF: APPROVAL: CONSTRUCTION:
SUBMITTED BY: DATE:
UNIT DESIGNATION: SCHEDULE NO. MODEL NO.
PRODUCT DATA DIMENSIONS - INCHES
Cooling Performance 10-3 T �, _ / j AIR HANDLER TOP (All Models)
1 -- , / -� - '1 —s%
Tota Capacity* MBH _ *J
Sensible Capacity* MBH ' I
Temperature of Air Entering 1 A
AIR HANDLER 1
Indoor Coil °F (DB/WB MA /MV C /
I <.' ", 1
Supply Air Blower Performance __ G /Or_ 24.,/21 1
Total Supply Air CFM OTALHEicHT) o_ .
Total Resistance External To Unit IWG 1 AIR HANDLER BOTTOM OPENING
Cooling Blower Speed Tap RPM —_ Hs:7, �.
Motor Rating HP A
COIL /
Electrical Data MG
Power Supply / _ / _ 1 COIL BOTTOM OPENING
Total Unit Ampacity AMPS a - e `°" __.„. _�
Minimum Wire Size AWG . ' z,5 1" fib.
(Copper conductors) '' y
Maximum Overcurrent Device AMPS ter
❑ Fuses (Dual Element)
❑ Circuit Breaker HACK NOTE: Power wtnng may be brought into the unit through one of the knockouts to either the top or the left side panel-
(HACR) Multiple knockouts are provided to accommodate all of the electnc heat and transformer accessories that are available
Use the knockouts that provide the best wire routing for the accessory being used
Unit Weight
Total Operating Weight LBS Dimensions - Inches Wiring K.O.s1 Refrigerant
Connection
(Including field - installed accessories) Model A B C D E K Line Size
* Shown in Outdoor Unit Technical Guide Height Width Total Height Power Control Liquid Vapor
MAO8B 17 -1/2 16 -1/2 14 -19/32 7/8 (1/2) — —
CLEARANCES 1- 3/8(1)
MAl2B 17 -1/2 16 -1/2 14 -19/32 7 — —
Front 24"
25
Rear 0 "* MA14D 24-1/2 23 -1/2 21 -19/32 7/8 (1/2) 7/8 (1/2) — —
1 -3/8 (1)
Sides 0 "* MA16C 21 20 18 -3/32 1 -23/32 (1 -1/4) — —
0 Clearance allowed with or without Electric MA20D 24-1/2 23 -1/2 21 -19/32 1 -31/32 (1 -1/2) — —
• Heater MC18A "H 22 14-1/2 407 13-1/2 13-3/8 — —
MC24B "H 26-1/2 17 -1/2 57 16-1/2 16 -3/8 — —
MC30B"1-1 26-1/2 17 -1/2 Depending 16-1/2 16 -3/8 — — 3/4
MC35B "H 22 17 -1/2 on 16-1/2 16 -3/8 — —
combination —
C kill �` MC36C H 26-1/2 121/2 16-1/2
19 -7/8 — — 3/8 MC3613"1-I 26-1/2
MC42B' *H 32 17 -1/2 16-1/2 16 -3/8 — —
MC42C "H 32 21 20 19 -7/8 — —
7/8
MC48C * *H 32 21 20 19 -7/8 — —
MC480"1-1 32 24-1/2 23-1/2 23 -3/8
6;711 nsekeeping MC60D "H 32 24-1/2 23-1/2 23 -3/8 — —
Pramisea +, _ ti MC61D"H 36 24-1/2 61 23-1/2 23 -3/8 — —
'
Gse«rxr nrmno «
v 1tY RE:li1�
;,F .
ISO 9001 1 Parenthesis indicate conduit size.
Certified Quality 2. May be either 208/230 -1 -60 or 460 -3-60
Management System "- 2A, 2C indicates TXV, 3X indicates TXV must be field supplied See Outdoor Unit
H models are available with a factory installed horizontal drain pan
254951 -YSD -F -1106
526001 -YTGB -0710
CASED UPFLOW /DOWNFLOW AND PARTIAL CASED
Refrig. Face Rows Fin Tube Tube Fin Operating
Model Application Conn. Area Deep Per Coil Size Geometry Dia. Type TXV Weight
ry
Types (Sq. Ft.) In. (Lbs.)
FC35C3XN2 None 55
FC35C4FN1 Cooling/ 4F 57 r
FC35C4GN1 Heat Pump Sweat 3.9 3 12 (2) 16 x 17.5 1 x 0 -866 3/8 Enhanced 4G 57
FC35C4HN1 4H 57
FC36A3XN1 None 49
FC36A4FN1 Cooling! Sweat 4 86 2 14 (2) 20 x 17.5 1 x 0.866 3/8 Enhanced 4F 51
FC36A4GN1 Heat Pump 4G 51
FC36A4HN1 4H 51
FC36B3XN1 None 51
FC36B4FN1 Cooling/ 4F 53
Sweat 4 86 2 14 (2) 20 x 17.5 1 x 0.866 3/8 Enhanced -
FC36B4GN1 Heat Pump 4G 53
FC36B4HN1 4H 53 ,
- - FC36C3XN1 - -- - .. - - . -None 53
FC36C4FN1 Cooling/ Sweat 4,86 2 14 (2) 20 x 1 7 5 1 x 0.866 3/8 Enhanced 4F 55
FC36C4GN1 Heat Pump 4G 55
FC36C4HN1 4H 55
FC37A3XN1 Cooling/ None 56 '
FC37A4FN1 Heat Pump Sweat 4 86 3 12 (2) 20 x 17.5 1 x 0.866 3/8 Enhanced 4F 58
FC42B3XN1 None 60 '
FC42B4FN1 Cooling/ Sweat 5.83 2 14 (2) 24 x 17.5 1 x 0.866 3/8 Enhanced - 4F 62
FC42B4HN1 Heat Pump 4H 62
FC42C3XN1 None 62
FC42C4FN1 Cooling/ Sweat 5.83 2 14 (2) 24 x 17.5 1 x 0 866 3/8 Enhanced 4F" 64
FC42C4HN1 – Heat Pump 4H 64
FC43B3XN1 None 56
FC43B4FN1 Cooling/ 4F 58 '
�FC4364GN1 Heat Pump Sweat 4.86 3 12 (3) 20 x 17.5 1 x 0.866 3/8 Enhanced 4G 58
FC43B4KN1 4K 58
FC43C3XN1 None 58
FC43C4FN1 Cooling/ 4F 60 '
FC43C4GN1 Heat Pump Sweat 4 86 3 12 (2) 20 x 17 5 1 x 0 866 3/8 Enhanced 4G 60
FC43C4KN1 4K 60
FC48C3XN1 None 63
FC48C4FN1 4F 65
FC48C4HN1 Cooking/ Sweat 5 35 3 12 (2) 22 x 17.5 1 x 0,866 3/8 Enhanced 4H 65
FC48C4JN1 Heat Pump 4J 65
FC48C4KN1 4K 65
FC48D3XN1 None 71
FC48D4FN1 4F 73
FC48D4HN1 Cooling/ Sweat 5 35 3 12
Heat Pump (2) 22 x 17.5 1 x 0 866 3/8 Enhanced 4H 73
FC48D4JN1 4J 73
FC48D4KN1 4K 73
FC60C3XN1 None 63
FC60C4GN1 4G 65
FC60C4HN1 Cooling/ Sweat 5 83 3 12 (2) 24 x 17.5 1 x 0,866 3/8 Enhanced 4H 65
•
FC60C4JN1 Heat Pump 4J 65 4<
FC60C4KN1 4K 65
FC60D3XN1 None 76
FC60D4GN1 4G 78
FC60D4HN1 Cooling/ Sweat 5,83 3 12 (2) 24 x 17.5 1 x 0 866 3/8 Enhanced 4H 78
FC60D4JN1. Heat Pump 4J 78
FC60D4KN1 4K 78
FC62D3XN1 None 88
FC62D4HN1 Cooling/ 4H 90
FC62D4JN1 Heat Pump Sweat 6 8 3 12 (2) 28 x17 5 1 x 0.866 3/8 Enhanced 4J 90
FC62D4KN1 4K 90
. _
8 Johnson Controls Unitary Products •-
•
550569 -YTG -C -1010
COOLING CAPACITY - Coil Only
• MBH @ Evaporator Temperature and
Blower Coil Rated Entering Air °F Corresponding Pressure °F /PSIG
Model Model CFM (Dry/V1let Bulb) 35161.5 40!68.6 I 45/76.0 50/84.0
Multi- Position - UpflowlDownflow /Horizontal
85/72 41.5 37.8 33.7 29.5
MC30B"H 1025 80/67 36.2 32.4 28.6 24.5
75/62 29.1 25.3 24.0 19.2
MV12B 70157 24.1 21.5 18.7 15.8 .
85/72 52.0 47.3 42.3 37.3
MC36B 'H 1250 80/67 41.7 36.8 32.3 27.4
75/62 32.5 27.3 29.8 22.2
70157 27.9 25.8 23.8 22.2 '
85/72 46.8 42.4 37.6 33.0
MC48D'"H 1125 80/67 37.4 33 3 29.4 24.3
• 75/62 ' . ' . . ' 28.9 ' " - 24.6 ' 21.7 • ' 19.6 '
70/57 25.1 23.3 21.7 19.6
85172 53.7 48.4 43.5 37.5 '
MV12D MC60D"H 1275
80/67 43 0 38.0 33.3 27.7
75/62 33.1 28.1 24.5 22.4
70/57 28.8. 26.5 24.5 22.4
85/72 91.7 78.4 681 52.3
MC62D * "H 1450 80/67 73.4 61.5 52.0 38.6
75/62 57.3 45.6 38.4 31.2
70/57 49.2 43 0 38.4 31.2
85/72 88 4 76.0 63.3 50.0
MC42C* •H 1400 80/67 70 8 59.4 48.4 37.0
75/62 55.2 43.9 35.8 29.9 '
MV16C 70/57 47,4 41.5 35.8 29.9
•
85/72 100.5 86.4 72.0 56.8
MC48C *"Fl 1650 80/67 80.4 67.5 55.0 42.1
75/62 62.7 49.9 40.7 34 0
70/57 53.9 47.2 40 7 34.0
85/72 119.9 101.0 80.0 62.2 .
MC48D"H 1725 80/67 96.0 79.2 62.6 45.8
75/62 74.0 58.6 46.2 37.0 1
70/57 64.3 55.4 46.2 37
85/72 124.8 105.2 85.3 64.7
MV200 MC60D"'H 2000 80/67 99.9 82.5 65.2 47.7
75/62 77 61.1 48.1 38.6
70/57 66 9 57.7 48.1 38 6
85/72 131.0 110.5 89.6 67.9
MC620 * *H P200
80/67 104.9 86.6 68.5 50.1
75/62 81.8 64.2 50.5 40.5
70/57 70.2 60.6 50 5 40.5
PHYSICAL & ELECTRICAL DATA
Model MV12B MV12D MV16C MV2OD
Blower - Diameter x Width - 10 x 7 10 x 10 10 x 10 10 x 10
• Motor HP 1/2 1/2 3/4 1
Nominal RPM 1200 1200 1200 1200
Voltage 208/230
Amps Full Load (230) 4 3 I 4.3 5.0 7.0 ,
Type DISPOSABLE OR PERMANENT
Permanent Filter Size 16 x 20x 1 24 x20 x1 20 x 20 x 1 24 x 20 x 1
Filter Bulk Kit 1 PF0601 BK 1 PF0604BK 1 PF0602BK 1 PF0604BK
Shipping /Operating Weight(Ibs.) 75/71 88/82 88/82 94/88
1. Field Supplied
4 Johnson Controls Unitary Products
0
z
O m
•
o rn
( 7�
rn
r
r J'
ttlr "
i
• i.; p
g j PROJECT:
. w RE ITMEIER MECHANICAL Mallield11011110E1 19570 SW 9000 CT
IAL01 IAL TOALATIN, OR 97062
----‘ `
et�egaumagItmago CCB# 3 53770- CoPT5 L1C )
V #REITMM'972B1
8IPE p18G4L4eaE DETAIL