Loading...
Report • Mahn Office Salem Opine Bend Ogirr Carlson Testing, Inc. 5-130 SI 0031,_,4 -3 -1060160100, St NE Q +o.: oa allel Rd r, 7 7 OH 97223 Ph Phone OR3158 9. 1. ;3 6302 019 tle Plume / =03/ 68; 360 Phone (5031:F Phnrlc. (40 t30 -915 (5631684 -09il l ac (031589_1309 Fay 85-111330.9163 Construction Materials Testing & Inspection Special Inspection FINAL SUMMARY LETTER July 13, 2007 T0509634. F City of Tigard 13125 SW Hall Blvd Tigard, OR 97223 -8199 Attn: Building Department Re: Canterbury Place Phase 2B — Building 23 (a 735 _1068-7--SW Canterbury Lane — Tigard, OR Permit No.: BUP2005 -00306 Dear Sir or Madam: This is to certify that in accordance with Section 1704.1.2 of the International Building Code, we have performed special inspection of the following item(s) per our inspection reports only: Reinforced Concrete Installation of Adhesive Anchors All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC. Steven W. Leach Project Manager SW L /tm cc: Polygon Northwest Co — Dana Hunt CT Engineering — Todd Eaton Milbrandt Architects — Bob Weible ,ass - 5 �p/,` 4 PAGE # 1 OF1 MATERIALS �d7� �� � ��C�y( ,—, .4;4( ` REV. DATE 2/16/06 TESTING & INSPECTION C. \DOCUME-1 \DANN \LOCALS \ TEMP \060011 RP T(2 9 06) (2)'Doc o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Dana Hunt Polygon Northwest Homes Project: Canterbury Woods (CT #04196, MA #04 -34) 109 E. 13th St. Inspector: Phil Jacques AWS /Cwr #91010571 Vancouver, WA 98660 Ski Harris AWS /Cw1#03080431 Dan Colby AWS/CWI#00050471 Inspection Date: February 9, 2006 MTI #: 0-60011c STRUCTURAL STEEL WELDING INSPECTION REPORT On the above dates, our representative arrived at Pacific Steel Co., Middleton, ID to perform work on the referenced project as reported below. Work was in progress and completed, performed by two welders and one welder helper for clean up, pick up and staging procedures. Weldments consisted of complete joint penetration, single /multi -pass fillet welds on continuity plates and connection plates for wide flange moment columns and beams. The in- progress and completed work had material identification checked. All phases of work was monitored, inspected and documented with approval per AWS D1.1 and contract specifications and approved structural drawings. Note: Work was inspected without plans marked `approved'. CJP weldments on piece marks 12, 13 and 14 has been completed and ultrasonic non destructive testing performed. There were no relevant indications. If you have questions concerning this report, please call us at (541) 889 -3602. Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. )C Reviewed by: Phil Jacques Northwest Regional Manager 110 SE 2'd Avenue, Ontario, OR 97914 541 889 -3602 Fax 541 889 -3605 E -Mail mtior @mti- id.com www.mti- id.com