Loading...
Correspondence March 31, 2008 Gertz Construction Company Inc. 19200 SW 46 Ave. Tualatin OR, 97062 -8770 RE: Lot # 6 Project Information Building Permit: MST2008 -00013 Construction Type: VB Address: 13874 SW Halcyon Terrace Occupancy Type: R -3 Area: 3078 Sq. Ft. Stories: 2 The plan review was performed under the 2005 Oregon Residential Specialty Code. The review of the submitted plans will be completed when the following information is provided. 1. Please provide two copies of foundation details, with regards to seismic reinforcing. 2. Please revise footing F -24 with additional 3600# load from garage header, two copies needed. 3. Beam calculation packet (B -1 thru 9, hallway /casual dining, and GB -1) was missing from plans, please submit two copies. 4. When responding, provide an itemized letter stating in what way each issue has been addressed in the revision. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Brandon Shaw Plans Examiner BrandonS@tigard-or.gov Phone: 503.718.2425 Fax: 503.624.3681 Brandon Shaw From: Ken Gertz [Ken @Gertzco.com] Sent: Thursday, April 10, 2008 4:01 PM To: Brandon Shaw Subject: Re: Lot # 6 "Martin" Plan Thanks Brandon, I'm on it. B -4 is an old beam we don't need. Brandon Shaw wrote: > MST2008- 00013, Lot 6 > I need some clarification on the revised beam calcs I got Tuesday > B -2 ( 5.25" X 15" GLB) calcs have it as a 13' span, plans show a > 21' -6" span > B -3 (3.25" X 9" GLB) calcs have it as a 5' span w/ point load at > 3.5', is the (3) 3/6 X 7/6 window being replaced? > B -4 (4" X 8" DF) calc'ed at 4', it's not much of a beam but where is > specifically to be installed? > Brandon Shaw > Plans Examiner > Tigard OR, 97223 > 503 - 718 -2425 1 Brandon Shaw From: Brandon Shaw Sent: Thursday, April 10, 2008 2:16 PM To: 'Ken Gertz' Cc: 'jeff Subject: Lot # 6 "Martin" Plan MST2008- 00013, Lot 6 I need some clarification on the revised beam calcs I got Tuesday B -2 ( 5.25" X 15" GLB) calcs have it as a 13' span, plans show a 21' -6" span B -3 (3.25" X 9" GLB) calcs have it as a 5' span w/ point load at 3.5', is the (3) 3/6 X 7/6 window being replaced? B -4 (4" X 8" DF) calc'ed at 4', it's not much of a beam but where is specifically to be installed? Brandon Shaw Plans Examiner Tigard OR, 97223 503 - 718 -2425 1 Brandon Shaw From: Brandon Shaw Sent: Thursday, April 10, 2008 3:04 PM To: 'jeff Subject: MST2008- 00013, Lot 6 In addition to the first e -mail, there are two beams up stairs that I didn't see before. Master bedroom- 3 1/8" x 10 1/2" x 8' WI Point load@ 4.5' bearing girder truss F (Left to Right) Bedroom 3- 4" X 8" X 5' W /point load @ .5' bearing girder truss A (Left to Right) Brandon Shaw Plans Examiner Tigard OR, 97223 503 - 718 -2425 1 City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 iI March 31, 2008 1111 - g t - Gertz Construction Company Inc. 19200 SW 46t Ave. t4►��, Tualatin OR, 97062 -8770 6 1 "_ Pkr r � S P te! a. � R ECENED RE: Lot # 6 APR 3 ZOOS Project Information r ; i L;. ' �, ..<,. „r Building Permit: MST2008- 00013 Construction Type: VB Address: 13874 SW Halcyon Terrace Occupancy Type: R -3 Area: 3078 Sq. Fr. Stories: 2 The plan review was performed under the 2005 Oregon Residential Specialty Code. The review of the submitted plans will be completed when the following information is provided. 44' 1. Please provide two copies of foundation details, with regards to seismic reinforcing. psx. 2. Please revise footing F -24 with additional 3600# load from garage header, two copies needed. /wet 3. Beam calculation packet (B -1 thru 9, hallway /casual dining, and GB -1) was missing from plans, please submit two copies. 4. When responding, provide an itemized letter stating in what way each issue has been addressed in the revision. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Brandon Shaw Plans Examiner BrandonS@tigard-or.gov Phone: 503.718.2425 Fax: 503.624.3681 Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 J . r 1L ELJ PROJECT ADRESS: APR 8 20E3 13 874 SW Halcyon Terrace �, Lot �r � L �f � � , `c a� , 12) PERMIT #: MST2008 -00013 BUILDNC4. DDMSiWj PLANS REVISED BY: JEFF GERBERG -503- 218 -5121 PLAN CHECK RESPONSE: Item #1: Added new footing detail to plans calling out reinforcement. New detail attached (2 - copies). Item #2: Revised f -24 footing with additional 3600# loads. Footing changed to 51 "X51 "X12" with (7) #4 e /w. New calc. attached (2 copies). )(.e6 32 No ai,7a Item #3: Attached (2) copies of missing beam calcs b -1 thru b -9 & gb -l.