Correspondence March 31, 2008
Gertz Construction Company Inc.
19200 SW 46 Ave.
Tualatin OR, 97062 -8770
RE: Lot # 6
Project Information
Building Permit: MST2008 -00013 Construction Type: VB
Address: 13874 SW Halcyon Terrace Occupancy Type: R -3
Area: 3078 Sq. Ft. Stories: 2
The plan review was performed under the 2005 Oregon Residential Specialty Code. The review
of the submitted plans will be completed when the following information is provided.
1. Please provide two copies of foundation details, with regards to seismic reinforcing.
2. Please revise footing F -24 with additional 3600# load from garage header, two
copies needed.
3. Beam calculation packet (B -1 thru 9, hallway /casual dining, and GB -1) was missing
from plans, please submit two copies.
4. When responding, provide an itemized letter stating in what way each issue has been
addressed in the revision.
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of
Tigard in tracking and processing the documents.
Respectfully,
Brandon Shaw
Plans Examiner
BrandonS@tigard-or.gov
Phone: 503.718.2425
Fax: 503.624.3681
Brandon Shaw
From: Ken Gertz [Ken @Gertzco.com]
Sent: Thursday, April 10, 2008 4:01 PM
To: Brandon Shaw
Subject: Re: Lot # 6 "Martin" Plan
Thanks Brandon, I'm on it.
B -4 is an old beam we don't need.
Brandon Shaw wrote:
> MST2008- 00013, Lot 6
> I need some clarification on the revised beam calcs I got Tuesday
> B -2 ( 5.25" X 15" GLB) calcs have it as a 13' span, plans show a
> 21' -6" span
> B -3 (3.25" X 9" GLB) calcs have it as a 5' span w/ point load at
> 3.5', is the (3) 3/6 X 7/6 window being replaced?
> B -4 (4" X 8" DF) calc'ed at 4', it's not much of a beam but where is
> specifically to be installed?
> Brandon Shaw
> Plans Examiner
> Tigard OR, 97223
> 503 - 718 -2425
1
Brandon Shaw
From: Brandon Shaw
Sent: Thursday, April 10, 2008 2:16 PM
To: 'Ken Gertz'
Cc: 'jeff
Subject: Lot # 6 "Martin" Plan
MST2008- 00013, Lot 6
I need some clarification on the revised beam calcs I got Tuesday
B -2 ( 5.25" X 15" GLB) calcs have it as a 13' span, plans show a 21' -6" span
B -3 (3.25" X 9" GLB) calcs have it as a 5' span w/ point load at 3.5', is the (3) 3/6 X 7/6 window being replaced?
B -4 (4" X 8" DF) calc'ed at 4', it's not much of a beam but where is specifically to be installed?
Brandon Shaw
Plans Examiner
Tigard OR, 97223
503 - 718 -2425
1
Brandon Shaw
From: Brandon Shaw
Sent: Thursday, April 10, 2008 3:04 PM
To: 'jeff
Subject: MST2008- 00013, Lot 6
In addition to the first e -mail, there are two beams up stairs that I didn't see before.
Master bedroom- 3 1/8" x 10 1/2" x 8' WI Point load@ 4.5' bearing girder truss F (Left to Right)
Bedroom 3- 4" X 8" X 5' W /point load @ .5' bearing girder truss A (Left to Right)
Brandon Shaw
Plans Examiner
Tigard OR, 97223
503 - 718 -2425
1
City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223
iI
March 31, 2008 1111
- g t -
Gertz Construction Company Inc.
19200 SW 46t Ave. t4►��,
Tualatin OR, 97062 -8770 6
1 "_ Pkr r � S P te!
a. � R ECENED
RE: Lot # 6 APR 3 ZOOS
Project Information r ; i L;. ' �,
..<,. „r
Building Permit: MST2008- 00013 Construction Type: VB
Address: 13874 SW Halcyon Terrace Occupancy Type: R -3
Area: 3078 Sq. Fr. Stories: 2
The plan review was performed under the 2005 Oregon Residential Specialty Code. The review
of the submitted plans will be completed when the following information is provided.
44' 1. Please provide two copies of foundation details, with regards to seismic reinforcing.
psx.
2. Please revise footing F -24 with additional 3600# load from garage header, two
copies needed.
/wet 3. Beam calculation packet (B -1 thru 9, hallway /casual dining, and GB -1) was missing
from plans, please submit two copies.
4. When responding, provide an itemized letter stating in what way each issue has been
addressed in the revision.
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of
Tigard in tracking and processing the documents.
Respectfully,
Brandon Shaw
Plans Examiner
BrandonS@tigard-or.gov
Phone: 503.718.2425
Fax: 503.624.3681
Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772
J . r 1L
ELJ
PROJECT ADRESS: APR 8 20E3
13 874 SW Halcyon Terrace
�,
Lot �r � L �f � � , `c a� , 12)
PERMIT #: MST2008 -00013 BUILDNC4. DDMSiWj
PLANS REVISED BY:
JEFF GERBERG -503- 218 -5121
PLAN CHECK RESPONSE:
Item #1:
Added new footing detail to plans calling out reinforcement. New detail attached (2 -
copies).
Item #2:
Revised f -24 footing with additional 3600# loads. Footing changed to 51 "X51 "X12" with
(7) #4 e /w. New calc. attached (2 copies). )(.e6 32 No ai,7a
Item #3: