Correspondence I. I March 28, 2008 Gertz Construction Company Inc. 19200 SW 46t Ave. Tualatin OR, 97062 -8770 RE: Lot #2 Project Information Building Permit: MST2008 -00017 Construction Type: VB Address: 13794 SW Halcyon Terrace Occupancy Type: R -3 Area: 3016 Sq. Ft. Stories: 2 The plan review was performed under the 2005 Oregon Residential Specialty Code. The review • of the submitted plans will be completed when the following information is provided. 1. Please provide two revised copies of the Truss details to match the plan roof lay out. 2. Page 3 of 7 as per R403.1.4 - please provide revised #1 footing detail calling out construction joint in footing and stem wall, as no vertical rebar is shown or called for, provide two revised copies. 3. Beam calculations packet was missing M -4 5 1/8"x 12" GLB, please supply two copies. 4. When responding, provide an itemized letter stating in what way each issue has been addressed in the revision. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Brandon Shaw Plans Examiner BrandonS @tigard - or.gov Phone: 503.718.2425 Fax: 503.624.3681 Brandon Shaw From: Brandon Shaw Sent: Wednesday, April 02, 2008 2:15 PM To: 'Ken Gertz' Subject: RE: MST2008 -00017 I'm missing the back portion (not referenced on details) of the roof trusses over the bedrooms and /or please locate trusses W- end jacks, side jacks, and mono U- hip girder & end jacks V- end & hip X- end & hips Y- mono Gidder truss marked U on details(supporting trusses b,c,& d) is missing. W -hip truss over garage has reations of 1836 #, plans show reactions of 1500 #, please verify that additional weight isn't going to affect beams and footings. Brandon Shaw Plans Examiner Tigard OR, 97223 503 - 718 -2425 Original Message From: Ken Gertz [mailto:Ken @Gertzco.com] Sent: Wednesday, April 02, 2008 12:02 PM To: Brandon Shaw Subject: MST2008 -00017 Brandon, On lot 2 of Edgewood, MST2008- 00017, are you missing the truss engineering, or is there something you see that is wrong? I have a set, and am not seeing a problem? Can you clue me in? Thanks Ken Gertz 1 Brandon Shaw From: jeff [Jeff@markstewart.com] Sent: Monday, April 07, 2008 10:20 AM To: Brandon Shaw Cc: 'Ken Gertz' Subject: RE: [Fwd: Re: MST2008 00017] Attachments: SKMBT_C55008040710040.pdf; REVISED 3RD CAR GAR FOOTINGS.pdf Hello Brandon, Here's the new calc showing a 1900# load from the girder and revised footing calculations with a markup on the foundation showing a bigger footing (F -24) that should replace the original (NF -A) footing . The right side footing still works. Please let me know if you need anything else. Thanks. Jeff Gerberg Architectural CAD Drafter /Designer Mark Stewart Home Design 22582 S.W. Main St. Sherwood, Oregon 97140 Direct phone: 503 - 218 -5121 Main office: 503 - 885 -8377 Fax: 503- 579 -4132 www.markstewart.com Original Message From: Ken Gertz [mailto:Ken @Gertzco.com] Sent: Friday, April 04, 2008 5:00 PM To: Mark Stewart; Jeff Gerberg Subject: [Fwd: Re: MST2008- 00017] Kingfisher 3 car Lot 2 Edgewood Please check the Last line of Brandon's E -mail RE: the W hip truss, and get back to me please. Thanks KG 1