Loading...
Correspondence March 17, 2008 Gertz Construction Co., Inc. 19200 SW 46 Ave. Tualatin OR, 97062 -8770 RE: Edgewood, Lot 5 Project Information Building Permit: MST2008 -00014 Construction Type: VB Address: 13858 SW Halcyon Terrace Occupancy Type: R -3 Area: 3138 Sq.Ft. Stories: 2 The plan review was performed under the 2005 Oregon Residential Specialty Code. The review of the submitted plans will be completed when the following information is provided. • 1. G- Girder truss has a reaction of 77491b. left /right sides. Please supply calculations and or new footing size for the additional load (garage /entry wall only has a point load of 35971bshown.) 2. Please provide new calculations and dimensions for the following beams, a. Floor BM. B- packet shows beam to be 19' outside dimensions, plans scale out to 20' -8" outside post to post. b. Floor BM. E- packet... to be 4' -6 ", plans ... 5' -9" outside, post to post. c. Header BM. 7- packet ... to be 7', plans ... 8' -3" outside, post to post. 3. Floor beams G and F do not scale out on the plans as shown in the beam cant. packet; it appears that they may have been switched. I can red line the correction or I need a revised pg. 7. 4. When responding, provide an itemized letter stating in what way each issue has been addressed in the revision. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Brandon Shaw Plans Examiner BrandonS @tigard - or.gov Phone: 503.718.2425 Fax: 503.624.3681