Correspondence April 7, 2008 MI Builders Jeff Kremer 14385 Fosberg RD. Lake Oswego OR, 97035 RE: Rankin Residence Project Information Building Permit: MST2008 -00030 Construction Type: VB Address: 7080 SW Taylors Ferry RD. Occupancy Type: R -3 Area: 1280 Sq. Ft. Stories: 2 The plan review was performed under the 2005 Oregon Residential Specialty Code. The review of the submitted plans will be completed when the following information is provided. 1. Per Table R502.3.1 (2), Floor and floor /ceiling joist, 2X10 @ 16" o.c. (Douglas fir #2) have a maximum span length of 15' -5 ", revise per table or provide listed product and engineering. 2. Per R802.3- Ridge shall be not less in depth than the cut end of the rafter. 3. Per R802.3.1- ... the ridge formed by these rafters shall also be supported by a girder designed in accordance with acceptable engineering practices. 4. Up lift resistance, per R 802.11- roof tie down, what type of rafter /truss ties are to be used? 5. Wall bracing (prescriptive path) and /or lateral analysis per R602.10- What is the intended method to meet the requirements for wall bracing? 6. Crawl space ventilation per R408.1- 1 Sq. Ft. per 150 Sq. Ft. of crawl space, minimum requirements needs to be adequate. 7. Provide manufacturers specifications for intended insulation (R -38) installation in 2X10 rafters and maintaining minimum clearances as per R806. 8. When responding, provide two copies and an itemized letter stating in what way each issue has been addressed in the revision. RHI Builders The right choice. OR CCB# 156954 / Bonded / Insured WA #RHIBU * *930B2 April 15 2008 RE: Rankin Residence Building Permit: MST2008 -00030 Address: 7080 SW Taylors Ferry Rd. Area: 1280 Sq. Ft. Construction Type: VB Occupancy Type: R -3 Stories: 2 The issues, as per a letter from the City of Tigard dated 4/7/08, have been addressed as follows: 1) See revised Section plan calling out for 14" TJI's placed 16" oc. 2) Ridge has been changed to 2X12 (Section plan). 3) See revised Section plan calling out for 2X6 collar ties i V o.eboa,.6. , nve) art evle. , twee 40 b•c v∎ .0.....V or veV iscd des■oft. 4) Section plan revised to call out for H2.5 rafter ties. .∎ a �� ff 5� - /5 6 115 .4) ) 5) Wall bracing called out for on Section plan to be %2" ply sheathing nailed 6" oc at corner panels and 12" oc in the field with I Od nails. 7) Insulation corrected to be R30, as per Section plan. ‘ UVv C . •, S eR.ce. e rot►:c)e e.). I/ �.... Q- 3o cc_ 3.4sukQlto•. e �,�, J Thank you, Cal )€c) e. J Cot tees- ANNe se i SS Lake Oswego: Oregon 97035