Correspondence Gary Noble - Niche Electrical Upgrade Project Dwg E1 Rev 1 Page 1 �L-C o 2O?9�o - c'/Z7 / 5 7 8 ° 7740 s<.! 1601/vu S From: Rob Murchison To: Noble, Gary; Watkins, Hap Date: 7/13/2006 2:13:39 PM Subject: Niche Electrical Upgrade Project Dwg El Rev 1 Gary, I received the stamped drawing El on June 29, 2006 from Gregg Scholz, P.E. This drawing illustrates the revision of adding a disconnect per your review. I subsequently hand delivered a full -size set copy on your desk several days latter while you were out. Hopefully this answers any questions on where /whom the drawing came from. If not, please call or email. Regards, Rob Robert M Murchison, P.E. Engineer, Public Works Department City of Tigard 13125 SW Hall Tigard, OR 97223 Phone: (503) 718 -2699 E- mail:robm @tigard - or.gov • •. Post -its Fax Note 7671 Date 6. Qag s► Frahler Electric Co. To FRAI.ItA & ELEei From c 1 0\1013L F 11860 SW Greenburg Rd. Co./Dept. co. Cal`{ OF T T \GAtL Tigard, OR 97223 Phone # Phone # 503. ' 11 [�. 244 6 Date: June 5, 2005 Fax # 503 .01.9 0 3 Fax # 5 0 3. 62.4 .3 a Project: IT Building, City of Tigard Permit # ELC2006 -00157 Dear Sir, I have started the plan review for the above mentioned project. Additional information is required for the completion of the plan review. Please submit the information requested below as soon as possible to facilitate the plan review. 1) The feeder installed between the emergency generator and the transfer switch requires a disconnect per Art. 225.31. 2) The required disconnect shall be located per Art. 225.32. 3) The exception for the disconnect mounted at the generator allowed in Art. 702.11 is only valid for a readily accessible disconnect. If this generator is mounted in a fenced area and the generator is a locked unit making the disconnect mounted on the generator inaccessible, a separate disconnect will be required. 4) Grounding of the generator shall comply with Art 250.4 (A)(5) 5) Provide Fault Current at service and at secondary of XFMR "T1" and other information as required by OAR 918 - 311 -0010. 6) The plan requires a transfer switch capable of neutral transfer time delay. (See Note 3.) How will this be accomplished with a 3 pole transfer switch? 7) All 30 amp circuits require a #10 awg ground conductor, not a #12 awg shown in note 7 of the circuit schedule. Thank you, Gary Noble Electrical Plans Examiner City of Tigard, OR Phone: 503.718.2446 Fax: 503.624.3681 06/12/2006 09:21 FR HLER ELECTRIC COMPANY 95036848840 NO.834 D01 06/05/2006 14:41 50362436e1 •- `, 06/85/2056 14 :34 5036243681 TIGARD BUILDING DEPT PAGE 01/01 -- -- _ ___ ., ._ — — 7671 Ome Past - te Fax Note Et i e_ Prattler Electric Co. co• , li r ka(icfr7 4 11860 SW Greenberg Rd. - , ' Tigard, OR 97223 Fax r . 4, j4/ p Date: June 5, 2005 - /a' - ? 5'® Project IT Building, City of Tigard Permit # ELC2006 -00 Dear Sir, J have started the plan review for the above mentioned project. Additional information is • required for the completion of the plan review. Please submit the information requested below as soon as possible to facilitate the plan review. 1) The feeder installed between the emergency generator and the transfer switch ' requires a disconnect per Art. 225.31. 2) The required disconnect shall be located per Art- 225.32. 3) The exception for the disconnect mounted at the generator allowed in Art. 702.11 is only valid for a readily accessible disconnect. If this generator is mounted in a fenced area and the generator is a locked unit making the disconnect mounted on the generator inaccessible, a separate disconnect will be required, 5) Provide Fault Current at service and at secondary of XFMR "TI" and other information as required by OAR 918- 311 -0010. /6, Gc c„ e.`,,,, -,/1 ,e Thank you, - -V1[e.i ch'ez.i :dt4. tip, • / / .. , 4 0,2„../7 0 1,',/7 . Gary Noble - Ne I evere,4 0_4 1 Electrical Plans Examiner City of Tigard, oR y c - .4- + -' Phone: 503.718.2446 Fax: 503.624.3681 • ec c-,-\- r cr,_,,„, -2-c R_ c r Gh e]1/4...)f Gc_ / ,,....,„0,,„_,.., e.-k‘-‘,(..-_,Ic...- - 16 6.t j 0 L . eA Gary Noble - Power Switch over at the Nich Page 1 From: Gary Ehrenfeld To: Date: 7/7/2006 6:14:33 AM Subject: Power Switch over at the Nich At around 07:30 today the Nich will be switch over to temporary power to enable the crew to install the new electrical service for the building. They are expecting that we will be on temporary power until around 1400 at which time they will switch us over to the new services. We do not expect and interruption in the network when these switch overs occur. To be on the safe side please save your documents often while you are working on them. We will keep you updated by email during the day as things progress. Thanks Gary Ehrenfeld Director Information Technology 503.718.2415 This transmission (including any attachments) may contain confidential information, privileged material (including material protected by the solicitor - client or other applicable privileges), or constitute non - public information. Any use of this information by anyone other than the intended recipient is prohibited. If you have received this transmission in error, please immediately reply to the sender and delete this information from your system. Use, dissemination, distribution, or reproduction of this transmission by unintended recipients is not authorized and may be unlawful. Rob Murchison - Fault current letter to city doc Page 1 R6 VAT ENGINEERING, INC. "Engineering Integrated Solutions" June 19, 2006 868.002.002 Rob Murchison City of Tigard 12800 SW Ash Ave. Tigard, OR 97223 Subject: Niche Building Electrical Dear Rob: The following is a response to comments from the electrical inspector dated June 5, 2006 regarding the review of the electrical plans for the IT Building remodel. Question numbers correspond to the numbers on the original letter from the plans examiner. 1. The City has agreed to include a disconnect switch on the feeder from the generator. 5. The fault current at the service delivery point is 9,399 A. Since this is less than the minimum rating for electrical equipment, no other calculations were done beyond the service point. All equipment is specified to be rated 10,000 A minimum. Please call if you have any questions t >il n Sincerely, i rogl i �+ J' otC�el �, l -$ o�G ! ) j 1 .) ` ) Gregg H. Scholz, P.E. Electrical Engineer AS � r r73ro,,,j Cw S. 31rov .. * •(f-Sd.53 6Pc 1 9615 SW Allen Blvd., Suite 107 e Beaverton, OR 97005 e Phone: (503) 292 -6000 • Fax: (503) 726 -3326 354 NE Greenwood Ave., Suite 207 • Bend, OR 97701 Phone: (541) 322 -8940 e Fax: (541) 322 -8943 Toll Free: (877) 9RW -ENGR E -mail: Gregg Scholz