Loading...
Correspondence FILE COPY ,4 haw '1\ December 3, 2003 °}RED t Wyatt Fire Protection 9095 SW Burnham Road Tigard, OR 97223 RE: NEW FIRE SPRINKLER SYSTEM IN EXISTING BUILDING Project Information Building Permit: BUP2003 -00644 Construction Type: VN Tenant Name: Wyatt Fire Protection Occupancy Type: B /S -1 Address: 9095 SW Burnham Road Occupant Load: NA Area NA Stories: 2 Hazard: Light/ Ordinary Group 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The submitted plans are approved subject to the following. GENERAL The water supply for the system will be provided at a future date. The contractor shall provide a pressure test of the system for inspector approval. The building will be considered non - sprinkled until a connection to an approved water supply has been provided. SPRINKLER 1. A key box shall be installed within 20 feet of the riser room entrance. The bottom of the key box shall be not less than 8 feet nor more than 10 feet above the walking surface unless approved by the Fire Chief. 902.4.2 TVFR99 -01 Contact TVF &R for keybox at 503-612-7010 2. A supply of spare sprinklers (never less than 6) shall be maintained on the premises so that any sprinklers that have operated or been damaged in any way can be - promptly replaced. These sprinklers shall correspond to the types and temperature ratings of the sprinklers in the property. Standard 9 -1, section 2 -2.7.1 OSSC 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 • 3. A special sprinkler wrench shall be provided and kept in the cabinet along with the spare sprinklers to be used in the removal and installation of sprinklers. Standard 9 -1, section 2 -2.7.2 OSSC 4. A minimum of 18 inches shall be maintained between top of storage and ceiling sprinkler deflectors. The distance shall be increased to 36 inches for large drop sprinkler heads. Standard 9 -1, section 4 -4.1.6 and 4 -4.3.2 OSSC 5. Sidewall sprinkler deflectors shall be located not more than 6 inches or less than 4 inches from walls and ceilings. Standard 9 -1, section 4- 4.2.3.3 OSSC 6. Clearances shall be provided around all piping extending through walls, floors, platforms and foundations. Minimum clearance for pipe sizes 1 inch through 3 '/2 inches shall be not less than 1 inch. Minimum clearance for pipes 4 inches and larger shall be 2 inches. Standard 9 -1, section 4- 5.4.3.4 7. An approved audible sprinkler flow alarm shall be provided on the exterior of the building in an approved location. An approved audible sprinkler flow alarm to alert the occupants shall be provided in the interior of the building in a normally occupied location. 904.3.2 OSSC Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processin• the documents. Respectfu rian Bla1►' , Senior Plans Examiner ti 3i __,, Iu1IG 4 November 26, 2003 - CITY OF TI .• _ y-` D Wyatt Fire Protection OREGON 9095 SW Burnham Road Tigard, OR 97223 RE: NEW FIRE SPRINKLER SYSTEM IN EXISTING BUILDING Building Permit: BUP2003 -00644 Construction Type: VN Tenant Name: Wyatt Fire Protection Occupancy Type: B /S -1 Address: 9095 SW Burnham Road Occupant Load: NA Area: NA Stories: 2 Hazard: Light/ Ordinary Group 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The following information is required prior to issuance of the sprinkler permit. 1. The plans indicate "Future 4" Fire Service ". The submitted sprinkler plans can not be approved until a water source is provided. The structure indicated as "Future Building Phase 2" may never be constructed. Provide an automatic water supply in accordance with NFPA Chapter 9 2. Provide a plan indicating the location of the vault, FDC and supply line. Provide cut sheets for the vault, the valves and equipment in the vault, piping materials, joint restraint, etc... 3. Revise hydraulic calculations to be consistent with water supply layout. 4. A key box shall be installed within 20 feet of the riser room entrance. Indicate location of keybox on plans. Contact TVF &R for keybox at 503- 612 -7010 When submitting revised drawings, provide 3 copies and a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respect ly, Bri. n Blalock, Senior Plans Examiner 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772