Loading...
Plans J =0 L _ _ th(.lU�?L-t�� laciii .----�, C--1 -- DF- 52416:C • A3 -20 MS ®5UD /MS °I ®UD(E) Series 1= 1re'dITeALartl'1S Five Zone Fire Alarm Control Panel Ten Zone Fire Alarm Control Panel by Honeywell �.��� ��Y� ��A�� F � �'� f�` ��c? fi ��{� MJ General s f ',...1 fi The MS -5UD -3 is a five -zone FACP (Fire Alarm Control Panel) OCT 2��9 and the MS -1 OUD -7(E) is a ten -zone FACP. These control pan- els provide reliable fire signaling protection for small to medium -sized commercial, industrial, and institutional build- CITY OF TIGARD ings. Both panels include built -in communicators for Central BUI 1 , 16 Station Service and remote upload /download. y p ; a� Each of these FACPs is compatible with System Sensor's �� - microprocessor -based i series detectors. These conventional �� r smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory � . "freeze" signal when the ambient temperature falls below the ) . - detector rating. Additionally, both the MS -5UD -3 and MS -, �� 1OUD -7 are compatible with conventional input devices such ,, ' as two and four -wire smoke detectors, pull stations, waterflow � 1 devices, tamper switches, and other normally-open contact s } ' ' P p . & ? (,�. 8 devices. Refer to the Fire•Lite Device Compatibility Document ��� , for a complete listing of compatible devices. � ' � �' .,:� Outputs include four NACs (Notification Appliance Circuits), three programmable Form -C relays (factory programmed for -- T' l - 1.--- 'l f gi?10 Alarm, Trouble, and Supervisory) and 24 VDC special applica- � �+— tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone - Strobe Synchronization for System Sensor, Wheelock, line integrity. Centex, Faraday, or Amseco devices. Activation of a compatible smoke detector or any normally - Selective Silence (horn strobe mute). open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the - Temporal or Steady Signal. piezo sounder at the FACP, activate the communicator and - Silenceable or Nonsilenceable. FACP alarm relay, and operate an optional module used to • Optional CAC -5X Style Z (Class A) Converter Module for notify a remote station or initiate an auxiliary control function. NACs and IDCs (2 required for MS- 10UD -7). New options include a UL listed printer, PRN -6F and FireLite's • Form -C Relays for Alarm, Trouble and Supervisory - Con - ACT Internet Monitoring module. The FireWatch Series inter- tact Ratings 2.0 A@ 30 VDC or 30 VAC (resistive). net monitoring modules IPDACT-2 and IPDACT -2UD permit • 3.0 A total system current for MS- 5UD -3. monitoring of alarm signals over the Internet saving the 7.0 A total system current for MS 10UD 7. • monthly cost of two telephone lines. Although not required, the secondary telephone line may be retained providing backup • Optional Dress Panel DP -51050 communication over the public switched telephone line. • Optional Trim Ring TR -CE for semi -flush mounting. NOTE: The MS- 10UD -7E offers the same features as the MS- • 24 volt operation. ►��� /� �e s�.iGA R��st� 1OUD -7 but allows connection to 240 VAC. Unless otherwise • Low AC voltage sense. Ch i V ; D specified, the information in this data sheet applies to both the 120 ▪ Alarm Verification. VAC and the 240 VAC versions of these panels. Approved ........, .., f.ge...r.•io ft-4 NOTE: For ULC- listed models, see df- 60440. • PAS (Positive Alarm Sequeftliditionally Approved. . s.�....a.,� ( ! • • Automatic battery trickle ch 'fetter b: Follow.. E w r J i * Features • Up to eight ANN -BUS annunciators: a , et.....ti. t • Listed to UL Standard 864, 9th edition. - Optional 8 zone Relay Med e , ` RL y� � �r l . ID 4 j • Built -in DACT (Digital Alarm Communicator/Transmitter). - Optional LED Annunciator • •u e , 1-. o y • Style B (Class B) IDC (Initiating Device Circuit) - Optional Remote Annuncg • - MS -5UD -3 - five IDC5. - Optional Remote Printer - MS 1 OUD 7 ten IDCs. - Optional LED Annunciator Driver ANN -I /O. • Style Y (Class B) NAC (Notification Appliance Circuit) - spe • Optional 4XTMF module (conventional reverse polarity /city cial application power box transmitter). • - MS -5UD -3 - four NACs. PROGRAMMING AND SOFTWARE: - MS- 10UD -7 - four NACs. • Can be programmed at the panel with no special software 1 • Notification Appliances may be programmed as or additional equipment. - Silence Inhibit. • Programmable Make /Break Ratio. - Auto - Silence. • Upload /Download (local or remote) of program and data via integral DACT. DF- 52416:C • 05/12/2009 — Page 1 of 4 OFFICE COPY df- 52417:b • B -90 ANN-80 h FI •LITe warms 80-Character LCD Serial Annunciator by Honeywell TM AnnNriC o ors General The ANN -80 annunciator is a compact, backlit, 80- character LCD tire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC 3 Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The ANN -80 and the FACP communicate over a two -wire serial interface employing the ANN -BUS communication format. °° .. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL- listed, filtered power supply. ANN -80 is red; for white, order ANN -80 -W. The ANN -80 displays English- language text of system point �' a`• information including device type, zone, independent point ` alarm, trouble or supervisory status, as well as any $� P y y custom alpha lels roramme into the c ontrol pane. It nclues cn- trol swi of crit a yst funct keyswitch prevents unauthorized operation of the control switches.) r Up to eight ANN -80s may be connected to the ANN -Bus of each FACP. No programming is required, which saves time during system commissioning. Features � t • Listed to UL Standard 864, 9th Edition. - • Backlit 80- character LCD display (20 characters x 4lines). • Trouble OCT 2 9 2009 • Mimics all display information from the host panel. • Supervisory • • Control switches for System Acknowledge, Signal Silence, Alarm Silenced CITY l IGARD Drill, and Reset. BUILDING DIVISION • Control switches can be independently enabled or disabled Specifications at the FACP. • Operating voltage range: 18 VDC to 28 VDC • Keyswitch enables /disables control switches and mechani- • Current consumption @ 24 VDC nominal (filtered and non - cally locks annunciator enclosure resettable): 40 mA maximum. • Keyswitch can be enabled or disabled at the FACP. • Ambient temperature: 32 °F to 120 °F (0 °C to 49 °C). • Enclosure supervised for tamper. • Relative humidity: 93% ± 2% RH (noncondensing) at 32 °C • System status LEDs for AC Power, Alarm, Trouble, Supervi- ± 2 °C (90 °F ± 3 °F). sory, and Alarm Silence. • 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" • Local sounder can be enabled or disabled at the FACP. (3.49 cm.) deep. • ANN -80 connects to the ANN -BUS terminal on the FACP and • For use indoors in a dry location. requires minimal panel programming, • All connections are power - limited and supervised. • Displays device type identifiers, individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. Agency Listings and Approvals • Time -and date display field. • Aesthetically pleasing design constructed of durable Lexan. The listings and approvals below apply to the ANN -80. In some cases, certain modules may not be listed by certain approval • Surface mount directly to wall or to single, double, or 4" agencies, or listing may be in process. Consult factory for latest square electrical box. listing status. • Semi -flush mount to single, double, or 4" square electrical • UL: S2424 box. • • Can be remotely located up to 6,000 feet (1,800 m) from the • approved (ANN -80) panel. • CSFM: 7120- 0075:211 • Backlight turns off during AC loss to conserve battery power • MEA: 442 -06 -E (ANN -80) but will turn back on if an alarm condition occurs. • May be powered by 24 VDC from the host FACP or by remote The ANN -BUS power supply (requires 24 VDC). • Up to eight ANN 80s can be connected on the ANN BUS. POWERING THE DEVICES ON THE ANN - BUS FROM AUXILIARY POWER SUPPLY Controls and Indicators The ANN -BUS can be powered by an auxiliary power supply when the maximum number of ANN -BUS devices exceeds the • AC Power ANN -BUS power requirements. See the FACP manual for more • Alarm information. s ��,r ti „ b „, df- 52417:b • 05/30/08 — Page 7 of 2 SENSOR' i • Photoelectric Smoke Detectors r t b F max° A A` System Sensor i3,M series smoke detectors represent significant advancement in conventional detection. The i family is founded on three principles: installation TM ease, intelligence, and instant inspection. Features Installation ease.The 1 line redefines installation ease with its Plug-in detector line, mounting base included plug -in design. This allows an installer to pre -wire bases (included • with heads) The large wire entry port and in -line terminals provide • Large wire entry port ample room for neatly routing the wiring inside the base. The base • In -line terminals with SEMS screws accommodates a variety of back box mounting methods as well as • Mounts to octagonal and single gang back boxes, 4-square back direct mounting with drywall anchors. To complete the installation, i boxes, or direct to ceiling heads plug into the base with a simple Stop -Drop 'N Lock" action. Stop-Drop 'N Lock attachment to base Intelligence. i detectors offer a number of intelligent features • Removable detector cover and chamber to simplify testing and maintenance. Drift compensation and Built-in remote maintenance signaling smoothing algorithms are standard with the P line to minimize • nuisance alarms. 2 -wire i detectors can generate a remote LED- • Drift compensation and smoothing algorithms indicated maintenance signal when connected to the 2W -MOD2 • Simplified sensitivity measurement loop test /maintenance module or a panel equipped with the P • Wide-angle, dual color LED indication protocol.The SENS -RDR, a wireless device, displays the sensitivityof i detectors in terms of percent - per -foot obscuration. Loop testing via EZ Walk feature • Built -in test switch Instant inspection. The i series provides wide -angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out -of- sensitivity, alarm, or freeze trouble. When connected to the 2W -MOD2 loop test /maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on 2 -wire P detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings P IVIEA MSF((ATV LED APPROVED approved approved ` `„RO 5911 3011446 7272 - 1653152 290-01 -6 2093 3180932