Loading...
Plans RECEIVED AUG 3 0 2011 5fa 5FA Design Group, �- pIONGDIVISION STRUCTURAL I CIVIL I LAND USE PLANN 9020 SW Washington Square Dr., Suite 505, Portland, Oregon 97223 I p: (503) 641 -8311 I f: (503) 643 -7905 I www.sfadg.com STRUCTURAL CALCULATIONS Jolly Residence Underpinning 7410 SW Cherry Dr, Tigard, OR 97223 Terrafirma Foundation Systems PRop 59O22PE � `J F TIGARD V c Approved 'f .. t vJ 4 /� Conditionally Approved.,..,.....,... [ OREGON See Letter to: Follow..„ ... ,...,....., [ v < :<• 9 -0 -2003 G � Attached.... ,.. ,.... ,... G R E Y S • � � Pe Number: - r _ y - Add ..:: A.. .. ari EXPIRES: 12 -31 -11 B .: yi Date: 'i/ OFFICE COPY Approved plans shall be on job site. LIMITATIONS ENGINEER WAS RETAINED IN A LIMITED CAPACITY FOR THIS PROJECT. DESIGN IS BASED UPON INFORMATION PROVIDED BY THE CLIENT WHO IS SOLELY RESPONSIBLE FOR ACCURACY OF SAME. NO RESPONSIBILITY AND /OR LIABILITY IS ASSUMED BY, OR IS TO BE ASSIGNED TO THE ENGINEER FOR ITEMS BEYOND THAT SHOWN ON THESE SHEETS. Project No. 11 -094 August 25, 2011 21119 SFA Design Group, L.L.0 PROJECT NO. SHEET NO. STRUCTURAL I CIVIL I LAND USE PLANNING 11 -094 2of10 PROJECT DATE Jolly Residence Underpinning 8/25/2011 SUBJECT BY General Structural Notes JNF GENERAL STRUCTURAL NOTES REFER TO ATTACHED STRUCTURAL CALCULATIONS FOR NOTE VARIATIONS AND REQUIREMENTS SPECIFIC TO REFERENCED PROJECT. NOTES ON CALCULATIONS TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES. MATERIALS: BRACKET PLATES - ASTM A36 EXTERNAL SLEEVE - ASTM A500 GRADE B OR C SHAFT COUPLER - ASTM A513 TYPE 5 SHAFT COUPLING HARDWARE - GRADE 8 BOLTS WITH NUTS ALL - THREAD ROD - ASTM A193 GRADE B7 PIER CAP - ASTM A572 GRADE 50 PIER TUBES - ASTM A500 GRADE B OR C STRUCTURAL WF SHAPES - ASTM A992 -GR50 STRUCTURAL CHANNEL SHAPES - ASTM A36 STRUCTURAL ANGLE SHAPES - ASTM A36 HELIX PLATES (ROUND SHAFT) - ASTM A572 GRADE 50 HELIX PLATES (SQUARE SHAFT) - ASTM A36 WELDING NOTES: CONFORM TO AWS D1.1. WELDERS SHALL BE CERTIFIED IN ACCORDANCE WITH AWS REQUIREMENTS. USE E70 ELECTRODES OF TYPE REQUIRED FOR MATERIALS TO BE WELDED. CORROSION PROTECTION: SACRAFICIAL DESIGN THICKNESS - CAPACITIES INCLUDE A SCHEDULED LOSS IN STEEL THICKNESS DUE TO CORROSION FOR BLACK, UNCOATED STEEL. ANCHORS ARE DESIGNED FOR 50 -YEAR SCHEDULED SACRAFICIAL THICKNESS LOSS IN ACCORDANCE WITH ICC -ES AC358. INSTALLATION: SYSTEM TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS. MINIMUM INSTALLATION PRESSURE IS TO BE DETERMINED BY THE FOLLOWING EQUATION: PUSH PIER INSTALLATION PRESSURE (PSI): [DESIGN LOAD] X 2 / 9.62 SQ. IN. HELICAL PIER INSTALLATION TORQUE PRESSURE - RS -7 DRIVE (PSI): [DESIGN LOAD] X 0.67 / 9 FT' HELICAL PIER INSTALLATION TORQUE PRESSURE - RT -12 LOW TORQUE DRIVE (PSI): [DESIGN LOAD] X 1.05 / 9 FT' SQUARE SHAFT HELICAL TENSION TIE INSTALLATION TORQUE PRESSURE (PSI): [DESIGN LOAD] X 0.67 / 10 FT' MINIMUM INSTALLATION DEPTH IS 20' -0 "± UNO. CONTACT ENGINEER OF RECORD IF FIELD CONDITIONS DIFFER. PUSH PIER SPLICING: PILES ARE TO BE GRAVITY SPLICED WITH FITTING COUPLERS. BUILDING WEIGHT WILL ENSURE JOINTS DO NOT SEPARATE. HELICAL PIER SPLICING: PILES ARE TO BE MECHANICALLY SPLICED WITH GRADE 8 BOLTS WITH NUTS, ALL HOLES TO BE FILLED. INSPECTION & TESTING: CONTINUOUS INSPECTION IS REQUIRED DURING INSTALLATION PER IBC TABLES 1704.8 & 1704.9. LOAD TESTING SHALL BE PERFORMED IN ACCORDANCE WITH ASTM METHOD D1143 (QUICK METHOD). ONE PILE SHALL BE TESTED TO 150 PERCENT OF ACTUAL OR DESIGN LOAD UNLESS LESS RESTRICTIVE TEST LOAD IS ALLOWED BY THE STRUCTURAL ENGINEER OF RECORD. LOAD TESTING SETTLEMENT ACCEPTANCE CRITERIA SHALL BE NO GREATER THAN 0.04 INCHES. PUSH PIER TEST PRESSURE (PSI): [DESIGN LOAD] X 1.5 / 9.62 SQ. IN. HELICAL PIER TEST PRESSURE (PSI): [DESIGN LOAD] X 1.5 / 9.62 SQ. IN. SQUARE SHAFT HELICAL TENSION TIE TEST PRESSURE (PSI): [DESIGN LOAD] X 1.514.73 SQ. IN. . . S till SFA Design Group, D-D-c PROJECT NO. SHEET NO. STRUCTURAL | CIVIL I LAND USE PLANNING 11-094 »mm PROJECT DATE Jolly Residence Underpinning 8/25/2011 SUBJECT BY Push Pier Design Loads JNF ROOFTL = (15PSFoL+25PSFsJ(14)=58OPLF FL0ORrL=(15PSFnL+4OPSFu)(6.5)=358PLF FDNoL = (15OPCF)(0.671.33+.5~2)=284PLF SLA8nL= (15OPCF)(0.33~3)=15OPLF WALLA. =( -_ __-- . ; / 1 . /\ | I` 1 ' � t | ' i ■ | // \ , \ / / \ | � �� ^. / m n °. ,, J,A'N; I � / � � ' | i / P,f: I | ' / / / � ..g � / / / \ / / | | \ __/ / -_-� ' | / i �� / � � i ����--- -- �� \ _�_ __-_ ~_- ` � _` ..... _______ g (E) 2ND FLOOR/(E) ROOF PLAN -' : -' --- | ' | ' / | / / /| , / . |\ J. �� ) �� � • ' r ' �^ / |.x // i • r�� ^'n m . `"^ /./ �^ � / � �/ '/ |� ' �.i r.:1 � . 'T -, | "7 ' - �=� -=` `' �= ... `'``� h *' - -- -�| ��� '''= ===- - e - _ - ~ /-� . 2.-0” -. ". (E) FOUNDATION/(E) 1ST PIER LAYOUT PLAN ir (Pp Indicates location of FSI 288 push pier with FSI FS288B foundation bracke Max load to anchor = 3.5 x [560 + 358 + 284 + 150 + 180]=5292LB 1 11 1 1 9 SFA Design Group, LLC PROJECT NO. SHEET NO. STRUCTURAL I CIVIL I LAND USE PLANNING 11 -094 4of10 PROJECT DATE Jolly Residence Underpinning 8/25/2011 SUBJECT BY Foundation Supportworks 288 Push Pier System JNF Pier System = 288 Vertical Load to pier = 5.292 kips Minimum Installation Depth = 10.000 ft Eccentricity = 4.000 in Moment = 21.168 in -kips Unbraced Length = 4.000 ft Pier Properties Tube OD = 2.674 in Wall Thickness = 0.153 in k = 2.10 r = 0.893 in Note: Design thickness of A = 1.215 in pier and sleeve based on c = 1.337 in 93% of nominal thickness S = 0.724 in per AISC I = 0.968 in E = 29000 ksi Fy = 60 ksi Sleeve Properties Sleeve Length = 48 in Sleeve OD = 3.255 in Wall Thickness = 0.201 in r = 1.082 in Note: Sleeve reduces A = 1.927 in bending stress on main pier S = 1.387 in only I = 2.257 in E = 29000 ksi Fy = 50 ksi Sleeve Output Fb = 33.00 ksi fb = 10.68 ksi Sleeve OK Pier Output kl /r = 9.41 Cc = 97.68 F'e = 1685.97 ksi Fa = 35.08 kips fa = 4.36 ksi Fb = 39.60 ksi fb = 8.77 ksi Cm = 1.00 fa /Fa = 0.12 Eq H1 -3 may be used Eq H1 -1 NA Eq H1 -2 NA Eq H1 -3 0.35 Pier OK MAX LOAD TO ANCHOR = 5292LB 2.875" DIAMETER PIPE PILE WITH 0.165" THICK WALL 48" LONG 3.5" DIAMETER PIPE SLEEVE WITH 0.216" WALL MINIMUM 10' -0" INSTALLATION DEPTH AND 1500PSI INSTALLATION PRESSURE s � SFA Design Group, LLC PROJECT NO. SHEET NO. STRUCTURAL I CIVIL I LAND USE PLANNING 11 -094 5of10 PROJECT DATE Jolly Residence Underpinning 8/25/2011 SUBJECT BY Foundation Supportworks FS288B Bracket JNF Capacity of 314'0 GRB7 (125ksi) Threaded Rod 11 = 11 A D = 0.75 in Ft = 125 ksi At= 0.3436 in 1 = 4 I . Capacity = 42.95 kips 1 Block Shear at 3 /8 " Plate Gland O to OO Tss = 0.3(58)('/0)(10) 2 ' = 87 +0.5(58)( (2� mss., .TE �:_ _ , T I \ v p ■yam■ I Capacity of Weld ® ' • - E70 Electrodes = 70 ksi . E t ELfi z I (I Size of Fillet = 0.1875 in - 1 Capacity of Per Inch of Fillet = 2.784 kli =,. „ r I ; t` Length of Weld = 12.00 in i FhTE - „ I I; Capacity of Fillet = 33.41 kips m , - Capacity of 3 /8 Plate O l �'TE �'' i — ,.% _ 1 :� I _ _ At - 1.875 in2 —., . _ _ . — — — L......... 7 Ft= 21.6 ksi T = 40.5 kips ' � , t 1i = 0.03125 in ', I r � A = 0.375 in ' ;I � r = 0.289 in k= 1.00 !,i f °, = 6.75 in IN■IIIII■1 kl /r = 24.0 /2 ' Fa = 20.35 ksi 5 - /; ' S = 1.00 in Fb = 27 ksi RMAX = 15.43 kips 4 Limiting System Factor Fv = 14.4 ksi VALLOW = 29.03 kips CAPACITY OF SYSTEM (2 SIDES) = 15.43(2)= 30.86KIPS (BRACKET ONLY) 6 of 10 S1.5 — ■_- 3 "O PIPE 3/16, 0 3 / 4 "O GR B7 (125KSI) ALLTHREAD 3 /16 , - R3/8 ..i...1-LE- 3 /16 , 4 .-- ��i� PP , 3/1 1 _ Mk R R /4 / / 3/ MIL --� Ali s ! -1•m' 3 3 /16 ' 1u1 / 16 \ [El/2 _ 1 /4 1 i � S�� R 1/4 1i R3 /8 1111 I' II- 3 TYP 1 1 41, , , /16 Al' i 4 , s.D PR (--.A61N---F o R3 /6 � 69022PE 9 r 1 >/ OREGON FSI FOUNDATION BRACKET FS288B NY Y s . (C EXPIRES: 12 -31 -11 PROJECT NAME: PROJECT NO: BY: DATE: TERRAFIRMA FOUNDATION SYSTEMS JSF 5 F Design Group, LLE STRUCTURAL I CIVIL I LAND USE PLANNING TERRAFIRMA FOUNDATION SYSTEMS 9020 SW Washington Square Dr., Suite 350 sf a Portland, Oregon 97223 C 1 p: (503) 641 -8311 f: (503) 643-7905 V www.sfadesigngroup.com S1.5 7of10 miami 1I .1 1�' -= i -1 -- 0 0 I 0 1 13 /4" 13 /4" , c , I I Alk <TYP 3 16 V �2 1N Sy .... lio PROF ,� a iN -, -4 / - 10 _ � � 59022PE 9 r FSI FOUNDATION BRACKET FS288B s . 3._,, -0. OREGON ( t(■ 09 -2 4 EXPIRES: 12 - 31 - 11 PROJECT NAME: PROJECT NO: BY: DATE: TERRAFIRMA FOUNDATION SYSTEMS JSF 49 5FA Design Group, LLC STRUCTURAL I CIVIL I LAND USE PLANNING TERRAFIRMA FOUNDATION SYSTEMS 9020 SW Washington Square Dr., Suite 350 sfa Portland, Oregon 97223 S 1.2 p: (503) 641 -8311 f: (503) 643.7905 V 1 www.sfadesigngroup.com i S1.5 I Ippr10 v fa MIR -t1■1 2 ■st .1__. _ ■ NM i - - I I N 4/ I;I -, ... 5 Y 4 „ — h'' � 6 % 1 — I I 4 ,, Y4" 5y \ tcR5p PROFFs o 7„ (V 4 5 9022PE 9 —. 1' -O' r OREGON v p 9 FSI FOUNDATION BRACKET FS288B eY s. f. EXPIRES: 12 - 31 - 11 PROJECT NAME: PROJECT NO: BY: DATE: TERRAFIRMA FOUNDATION SYSTEMS JSF SFA Design Group, Li" STRUCTURAL CIVIL I LAND USE PLANNING TERRAFIRMA FOUNDATION SYSTEMS 9020 SW Washington Square Dr., Suite 350 5t a Portland, Oregon 97223 S 1 .3 p: (503) 641.8311 f: (503) 643 -7905 V 1 www.sfadesigngroup.com S1.5 9of10 7 III lin 11111111■I 5%" 3 3 " -r 1- u_ 11 o.-_ H110 K 1 )/" 1 ) " _- 0 � I 0 iii II .B.- W1 1_�1 II II .I II II II II li II II !! i II i II II li !j - 3Y2" ®M in ,0 ir s $Y4 4 69022PE r FSI FOUNDATION BRACKET FS288B . i SCALE: 3 =1' -0 OREGON 'EY S. ° EXPIRES: 12 - 31 - 11 PROJECT NAME: PROJECT NO: BY: DATE: TERRAFIRMA FOUNDATION SYSTEMS JSF SFA Design Group, LLC STRUCTURAL I CIVIL I LAND USE PLANNING TERRAFIRMA FOUNDATION SYSTEMS 9020 SW Washington Square Dr., Suite 350 ��� Portland, Oregon 97223 S1.4 p: (503) 641 -8311 f: (503) 643 -7905 www.sfadesigngroup.com Si.1 = 01 I1OI1 11 1 1 I I 1 Li__ 3— II I CD 1 i 1 , , Fr ; 1 - 1 1 I I I I 1i, Ii O L i I 4 , N 1 c � F , p PR OFF s S 1.3 \ �GINt S j 0 tv 69022PE FSI FOUNDATION BRACKET FS288B SCALE: 3 - -1' -0' 1 i• /if' • OREGON EXPIRES: 12 - 31 - 11 PROJECT NAME: PROJECT NO: BY: DATE: TERRAFIRMA FOUNDATION SYSTEMS JSF 5FA Design Group, LLC STRUCTURAL I CIVIL I LAND USE PLANNING TERRAFIRMA FOUNDATION SYSTEMS 9020 SW Washington Square Dr., Suite 350 sf a Portland, Oregon 97223 S ♦ . 5 p: (503) 641 -8311 f: (503) 643 -7905 I www.sfadesigngroup.com