Permit 71 CITY OF TIGARD MECHANICAL PERMIT
'7 8 ,1: COMMUNITY DEVELOPMENT Permit #: MEC2010 -00062
TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.639.4171 Date Issued: 03/02/2010
Parcel: 2S 102AD03450
Jurisdiction: Tigard
Site address: 8777 SW BURNHAM ST
Subdivision: Lot: 0
Project: City of Tigard
Project Description: Install (8) radiant heat panels at ceiling with seizmic supports in auditorium.
Owner: FEES
TIGARD, CITY OF & Description Date Amount
TIGARD WATER DISTRICT ET AL, 13125 SW Permit Fee 02/11/2010 $207.21
HALL BLVD Plan Review 02/11/2010 $51.80
PHONE: 12% State Surcharge - Mechanical 02/11/2010 $24.87
Contractor:
REITMEIER MECHANICAL
19570 SW 90TH CT
TUALATIN, OR 97062
PHONE: 503 - 603 -0205
FAX: 503 - 603 -0150
Type of Use: COM
Class of Work: ALT Type of Const: VB
Occupancy Grp: A -3 Occupancy Load:
Stories: 1
Fuel Air Handlers
Fuel Types: Electricity Units < 10000 cfm:
Gas Pressue: Units > 10000 cfm:
Furnaces Boilers & Compressors
Furnaces < 100K BTU: 0 -3 HP:
Furnaces >= 100K BTU: 3 -15 HP:
Floor Furnaces: 15 -30 HP:
Unit Heaters: 8 30 -50 HP:
Vents w/o Appliances: 50 or Greater HP:
Air Conditioning:
Heat Pump:
Appliances
Vent Fans: Vent Systems: Total $283.88
Hoods: Comm Incinerators:
Required Items and Reports (Conditions)
Woodstoves: Gas Fireplaces:
Clothes Dryers: Other Mech Units:
Gas Outlets: Other Desc:
Duct Work:
Fire /Smoke Dampers:
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other
applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of
issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon
Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of the rules
or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344.
�j
Issued By: � A \ (I r , Q , (� /1 J Permittee Signature: r� %�p t� ��
Call 503.639.4175 by 7:00 a.m. for an inspection that business day.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
Mechanical Permit Applicati /ED FOR OFFICE USE ONLY •
N 5 l Received
y / �
II - City of Tigard Date/By: PermitNo.: (�(vQ2010,�V10
q ?
13125 SW Hall Blvd., Tigard, OR 97223 W lfJ
+
y Plan Review
Phone: 503.639.4171 Fax: 503.598.1960 FEB 1 2010 Date/By: `� C Other Inspection ermit:
TIGARD tion Line: 503.639.4175 Date Ready :y: 0 See Page 2 for
Internet: www.tigard - or.gov CITY OF TIGARD No 'fied/Method:0 a• i, Supplemental Information
B _I 1' 1 S . .T!; , 5M'
>:TYPE °OF =-- ",WORK' .
��; �'COMNIER YA'L, EEE .SCHEDULE -. IJSE'CHEGKL[S'I?� L '
���. . ���:v. - -... �� ���_ �...:,:�:<'� - , _.� � ri� . k -.>o . � ...ate, _.
❑ New construction ® Addition /alteration /replacement Mechanical permit fees* are based on the value of the work
performed. Indicate the value (rounded to the nearest dollar) of all
❑ Demolition ❑ Other: mechanical materials, equipment, labor, overhead, and profit.
a •k.
Value: 4,99
-, .E^ :< i'r;r CATEGORY `OF CONSTRUCTIQN ; , ?x; ,, ;.
:.:�:x,.+w " +.,. �ww.�,:a-�,�„•, "r ..,..-. � ",..r
"'. _`: '';' :; }`• I„ RESIDENTIAL EQUIPMENT / SYSTEMS FEES*
❑ 1- and 2- family dwelling Z Commercial /industrial ❑ Accessory building
For special information use checklist.
❑ Multi- family ❑ Master builder ❑ Other: Description I Qty. I Ea. I Total
az„ JOB SITE 1NFORMATIONAND`LOCATION,
eattn coo ing
.:,... ,�.� „- -, � •- ....:.- ..,.,,.,,,> ., , -,....
Job site address: 8777 SW Burnham St Air conditioning
(requires site plan showing placement) 46.75
City/State /ZIP: Tigard, OR 97223 Fumace 100,000 BTU (ducts /vents) 46.75
Furnace 100,000+ BTU (ducts /vents) 54.91
Suite/bldg. /apt. no.: Project name: I2arliat-Pxenefs \. T x � ( Kt y _d , Heat pump 61.06
Cross street/directions to job site: "G• Duct work 23.32
Hydronic hot water system 23.32
Residential boiler (radiator or
hydronic) 23.32
Unit heaters (fuel -type, not electric),
in -wall, in -duct, suspended, etc. 46.75
Subdivision: Lot no.:
Flue/vent for any of above 23.32
Other 23.32
Tax map /parcel no.: Other fuel appliances
Water heater 23.32
= " >���,���;� � ✓ �; %DESC,RIP:.TIOP1 „OFWORIC -: -�� `t ;,
.,v'�c -° �,< . ; ���;.1a tis- .�s�"`,•. + % -:::: �-�:.:;.e,,:,...., _,e:.:.. .; �?R:..-<. -. :...sY�"t;r. = `s-� ^- .it�:n r::- ;;� •y":,
Gas fireplace 33.39
Install eight (8) radiant ceiling pannels in auditorium. Flue vent for water heater or gas
Each panne) to have four (4) seismic support wires attached to structure. fireplace 23.32
Log lighter (gas) 23.32
Wood/pellet stove 33.39
Wood fireplace/insert 23.32
" > Chimney /liner /flue/vent 23.32
23.32
Name: City of Tigard Environmental exhaust and ventilation
Address: 13125 SW Hall Blvd. Range hood/other kitchen
equipment 33.39
City /State /ZIP: Tigard, OR 97223 Clothes dryer exhaust 33.39
Single -duct exhaust (bathrooms,
Phone: ( ) Fax: ( ) toilet compartments, utility rooms) 23.32
:..x r•_. ":rte•„• ":, >, . > "„ / l ace fans 23.32
Attic/crawls
z),." ®APPLICANT ®C ONTACT PERSON r ' P
Other: 23.32
Business name: Reitmeier Mechanical
Fuel piping
Contact name: Matt Rogers $14.15 for first four; $4.03 for each additional
Address: 19570 SW 90 Court Furnace, etc.
Gas heat pump
City/State /ZIP: Tualatin, OR 97062 Walllsuspended/unit heater
Phone: (503) 603 -0205 Fax: : (503) 603 -0150 Water heater
Fireplace
E -mail: matt.rogers @reitmeiermechanical.com Range
i�r,'�:r -'.�; a - <3:��.r .'Kw ' :- ',,,..p .;:a,.r „�r�ro,� •,�>��y � ; ,:.; v, - :',�
+_.: "f: 601∎1:0 "CTOR.: ! Barbecue
Business name: Reitmeier Mechanical
Clothes dryer (gas)
Other:
.:.a;:`:
Address: 19570 SW 90 Court :° '. +; ° ° "` ° 1401''; NICAL' *FERMI #0..: ; ,.:w ,:--
City/State /ZIP: Tualatin, OR 97062 Subtotal X1, a \ .,
Phone: (503) 603 -0205 Fax: (503) 603 -0150 Minimum permit fee ($90.00)
Plan review (25% of pennit fee) C-NI. O
CCB lie.: 153770 State surcharge (12% of permit fee) 7
TOTAL PERMIT FEE C
Authorized signature: / r i This permit application expires if a permit is not obtained within 180
days after it has been accepted as complete.
Print name: Matthew Rogers Date: 2/9/2010 * Fee methodology set by Tri -County Building Industry Service Board
1:\ Building \Permits\MEC -PermitApp.doc 10/01/09 440 -4617T (1 I /02/COM/WEB)