Correspondence City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 `j
',. June 18, 2007
I mg _°_•,t
1 4 4
d�yk 4 Y
TI ARD
RE: IMPROVEMENT TO EXISTING BUILDING SHELI, r� �
Project Information
Building Permit: BUP2007 -00280 Construction Type: IIIB
Address: 6600 SW Bonita Rd. Occupancy Type: M
Area: 39,805 sq. ft. Stories: 1
The plan review was performed under the State of Oregon Structural Specialty
Code (OSSC) 2007 edition; 2007 Oregon Fire Code.
FIRE LIFE AND SAFETY / GENERAL
All exit doors shall be openable from the inside without the use of a key or any
special knowledge or effort. (Sec. 1008.1.8)
Exits and exit access doors shall be marked by an approved exit sign readily
visible from any direction of egress travel.
Access to exits shall be marked by readily visible exit signs in cases where the
exit or the path of egress travel is not immediately visible to the occupants.
(Sec. 1011.1)
Exit signs shall be illuminated at all times and shall be provided with a second
source of power that will provide 1 '/z hours of illumination in case of primary
power loss. (Sec. 1006.3) FYI
Additional exit signs may be required by the city field inspector to clearly
indicate the path of egress.
The means of egress shall be provided with illumination of not less than 1 foot
candle at the floor level anytime the building is occupied. The means of egress
illumination shall be provided with a second source of power in case of primary
power loss. (Sec. 1006.2)
Portable fire extinguishers shall be installed in new and existing Group A, B, E,
F, H, I, M, R -1, R -2, R -4, and S occupancies. (OFC Sec. 906)
American with Disabilities Act (ADA): It shall be the responsibility of the
Architect, Engineer, Designer, Contractor, Owner and Lessee to research the
applicability of the ADA requirements for the structure. The City of Tigard
reviews the plans and inspects the structure only for compliance with Chapter
11 of the OSSC, which may not include all of the requirements of the ADA.
Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval
stamp, shall be maintained on the jobsite. The plans shall be available to the
Building Division inspectors throughout all phases of construction. (106.3.1
OSSC)
Certificate of Occupancy: No building or structure shall be used or occupied
until the Building Official has issued a certificate of occupancy (109.1 OSSC)
Premises Identification: Approved numbers or addresses shall be provided
for all new buildings in such a position as to be plainly visible and legible from
the street or road fronting the property.
Respectfully,
- 0/ 4 *Nesin
\Dan Nelson
Senior Plans Examiner
•
•
City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223
June 15, 2007 ' `
e®
El
RE: ISSUANCE OF BUILDING PERMIT aa�
z K' Y 4 ' .1 A . ' yfi Y 'e
Project Information
Project Name: Paul Schatz Construction Type: IIIB
Building Permit: BUP2007 -00280 Occupancy Type: M
Address: 6600 SW Bonita. Rd. Occupant Load: 133
Dear Jennifer,
The Building Division has completed the review of the project listed above. The project
has not been released by either the Planning Division or the Engineering Division at the
time of this letter, so the Building Permit cannot be issued. If you have questions please
contact Maris Buxton @ 503 - 718 - 2453.
The date of this letter begins the 180 day time limitation in accordance with Section 105.3.2
of the State of Oregon, Structural Specialty Code, 2007 edition. If the permit has not been
issued within the time limitations referenced in section 105.3.2, the work shall be
considered abandoned and the plans will be expired.
Itespectfull ,
1
an Nelson,
Senior Plans Examiner
Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772
City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223
June 14 2007
•
RE: IMPROVEMENT TO EXISTING BUILDING SHELL GXRD
Project Information
Building Permit: BUP2007 -00280 Construction Type: IIIB
Address: 6600 SW Bonita Rd. Occupancy Type: M
Area: 39,805 sq. ft. Stories: 1
The plan review was performed under the State of Oregon Structural Specialty
Code (OSSC) 2007 edition; 2007 Oregon Fire Code. The submitted plans have
been reviewed and the following information is required prior to issuance of
the permit.
1) Provide complete drawings for skylight framing and glazing.
American with Disabilities Act (ADA): It shall be the responsibility of the
Architect, Engineer, Designer, Contractor, Owner and Lessee to research the
applicability of the ADA requirements for the structure. The City of Tigard
reviews the plans and inspects the structure only for compliance with Chapter
11 of the OSSC, which may not include all of the requirements of the ADA.
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval
stamp, shall be maintained on the jobsite. The plans shall be available to the
Building Division inspectors throughout all phases of construction. (106.3.1
OSSC)
Certificate of Occupancy: No building or structure shall be used or occupied
until the Building Official has issued a certificate of occupancy (109.1 OSSC)
Premises Identification: Approved numbers or addresses shall be provided
for all new buildings in such a position as to be plainly visible and legible from
the street or road fronting the property.
Respectfully,
.;
. an elson
Senior Plans Examiner
Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772
•
•
A ARCHITECTURAL
SPECIALTIES, INC.. ACRYLIC PYRAMID
(Curb Mount)
•
SPECIFICATIONS: Architectural Specioties Inc., •
skylights ore formed to a specified shape
from sheets Of clear, transluscent or •tinted PrRwro • DOW RcraraNc
type CC2 acrylic plastic. Acrylic domes to CAP•
it
conform to AAMA 1601.1 -1975 for a design -
load of 40npsf. Skylight frame -and retainer
cap shall be 6063 —T5 extruded aluminum I caHOOesKre
with minimum wall thickness of .070 inches. cutrEe
The skylight frame shall have on integral II cotes,«
condensation gutter, exterior drip and I WEEP sum
drainage slots. All mitered corners ore to be
welded by the heliarc process.
• cuvortc
518. CLLR E spa
1
•
1WCK
w000 CURB
ON OTHERS) _—cote nAsHu4c
(e• Onto:s)
•
•
O. FILL IN
Model No. of Outer Inner
Units Pyramid Pyramid
•
•
FINISH
• SAFETY CONSIDERATIONS: While Architectural Specialties, Inc.
STANDARD ACRYUC DOME COLORS' . skylights ore designed to support the weight of snow, ice
and the force of normal winds, they ore not designed •to
DESIGNATION COLOR withstand the weight of people. If human safety becomes
a consideration, skylights should be protected by railing,
grids or screens.
CL CLEAR COLORLESS NOTE: Double glazed skylights ore subject to formation of
21-47 WHITE TRANSLUSCENT condensation between domes. This may be objectionable
2412 TRANSPARENT SOLOR BRONZE when both domes ore tronsporenL
Minimum recommended pitch is 1/4' in 12".
PROJECT CONTRACTOR
ARCHITECT REPESENTATIVE
•
APPROVED BY DATE S#
Fire Marshal's Offices
RC j
' 1� �r ?� ®
North Division - 14480 SW Jenkins Rd., Beaverton, OR 97005 • PH (503) 356 - 4700 • Fax (503)644 - 2214
✓ �'
'Tualatin Valley � S Division - 7401 SW W Ct., Ste. 101, Tualatin, OR 97062 • PH (503) 612- 7t612-76W Fa (503) � L � j 6 -7003
i
Fire Sr Rescue A CffV 3rdr A D
Ho atilt nmin rmt14e
Building Survey Report
FMZ : (to be filled out by TVF &R) Code Edition:
Name of Facility: -PAKL -t +r. - I ur-NirbtR
Name of Building: 17146M V tt-LE.
Address: We 50 SW ti CT r! R• - KP r)P-Eot-s C li - XX -.
Owner: c-A 1 E5 .2 l-LC Telephone No. ( 503) c,e 2.0 - Lill 0 0
Architect:
t.-1 N lsIaN c0A'1' Telephone No. (So 3) _ 1 +4 - 0552 -
Architect Address: 911456 SIN 13" t-1"11)' 5'1 . :SkrT 1ZOi1 $\P-T ')124.6`6N1 gFX113
.,..., , -, .�e .,, .,.�`: .,, •.yam..: ,,�• - ., ., ✓,,.. . < �:: � 5.�.�
�„ ITE .vim . ,�.�_.. , . ,.,, COMM� . > ......:::. .......,,. DESCItIPTIONz> .;:< =_
1. Occupancy "'Sc, Type Tim Is! I Use 1--r-K11_ Capacity
2. Construction Type -713 Year Built p. 1 9 i...g
3. Area (Sq. Ft.) Total I (, 3 tp Is S F Largest Floor Basement ,,�/
4. Stories S C No. 1 Height Vt.c 5 High Rise El N
5 a. Exterior Wall Construction C — CorJ e 1Z , ETe T
b. Opening Protection N6 N g .
6. Interior Wall Construction
7. Floor Construction C, -C oNCr ETC 1-A1
8. Roof Construction
9. Attic Draft Stops No. N o f.
10a. Occ. Sep. Wall Construction No. N 01.1E
b. Opening Protection I 0 OF
l la. Fire Wall Construction No. N 0 N
b. Opening Protection 1 ( 0 N e
12a. Smoke Barrier Wall Construction No. N 0 N E;
b. Opening Protection ^ 1 14 -E
13a. Corridor Wall Construction H 014.e
b. Opening Protection N a 0-
14a. Corridor Ceiling Construction N 0 N-t
b. Opening Protection I Q NE
15a. Shafts No. N 0 N E Type
A
I
b. Opening Protection A o N�
• building Survey Keport
•
FMZ : (to be filled out by TVF&R)
Name of Facility:
ITEM i1 ; ;;;;: 1004i■t:.:
16a. Stair Enclosure No. NOIJE
b. Opening Protection N ONE
17. Stairs No. 3
C -
18. Ramps No. C C C RETE 17— ac)Pe
19. Interior Finish Class Room \J owe Corridor Exit Enclosure
20. Exits No.
Total Width 19_0°
21. Exit Hardware Type
o LEVER-
22a. Exit Signs/Illumination
b. Emergency Lighting
130,-rt 4e--14i
23. Auto Sprinkler Coverage - F
24. Standpipe Class/Locations
EXIS - 1 - 11■14
25. Fire Alarm Type/Coverage
IA Ntet■J 0
26. Heating, Ventilation & Air Conditioning Type A v 'Fuel
27. Electrical Installation S ) P- C Lt. LT ISP-WA
28. Stage/Platform
tr.+1■J
29. Hazardous Area
N 114
30. Other
Comments:
O — ucp#04 i/to+ 'PER— 7:+i TIE Sa. 114 — 1 VA (
t -e ik 3
Alternate Materials & Methods
, .
'TV,F&R Use Only • „
InspectedBy: - Date - No Attachments
RevieWed By: • I Date
Updated