Loading...
Specifications eg(i/ 7- 0053 3 t,^ (Ref: NFPA 72 [2006 Ed]) SimplexGrinnell BE SAFE. FIRE ALARM SYSTEM RECORD OF COMPLETION Name of protected property: Address: (eC70 Su....) )c6 - "_ t l C, c l l R — ( 7�`� � Representative of protected property (name /phone): Authority having jurisdiction: Address /telephone number: Installer: A '\ULSaXY - Q._ - 2 - %.0 ,, ®® r c Supplier: l Vk�1 IJ /'(tW< S AVG' 6283 ' ! Y()l`� Service organization: �tK� c �1.�1. . t)1L,( OLSD J `Cflc� J . 960I Organization name /phone Representative e /phone Location of record (as- built) drawings: Location of operation and maintenance manuals: Location of test reports: A contract for test and inspection in accordance with NFPA standard(s) Contract No(s): Effective date: Expiration date: System Software (a) Operating system (executive) software revision level(s): St KV 6L (b) Site - specific software rexisi date: (c) Revision completed by: A.A.) Cµ -VLVL AM0 A.. (name) (firm) 1. Type(s) of System or Service NFPA 72, Chapter 6 — Local If alarm is transmitted to location(s) off premises, list where received: NFPA 72, Chapter 8 — Remote Station ® 46 ‘S Ac. ---14 ' -T 2d - 5 Telephone numbers of the organization receiving alarm: . J 9P�� Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: 1 \›� NFPA 72, Chapter 8 — Proprietary Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: MC24 -2 -014 0806 Copyright NFPA AHJ - White; Owner - Canary; District - Pink; Site Copy - Goldenrod (NFPA 72, 1 of 4) NFPA 72, Chapter 8 — Central Station Prime contractor: Central station location: Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex One -way radio Digital alarm communicator Two -way radio Others Means of transmission of alarms to the public fire service communications center: (a) (b) System location: NFPA 72, Chapter 9 — Auxiliary Indicate type of connection: Local energy Shunt Parallel telephone Location of telephone number for recipient of signals: 2. Record of System Installation (Fill out after installation is complete and wiring is checked for opens, shorts, ground faults and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by on , includes the devices shown in 5 and 6, and has ben in service since NFPA 72, Chapters « 3 ® ®- 5 D (circle all that apply) NFPA 70, National electrical Code, Article 760 • 6 G. Manufacturers instructions Othe pe " ): Signed: / Date: Organiz- 3. Record of System Operation Documentation in accordance with Inspection testing Form, Figure 6.2.3, is attache ( r .00 ® All operational features and functions of this system were tested by -I— � date and found to be operating properly in accordance with the requirements of: NFPA 72, Chapters ®® 3 ID ®C3) (circle all that apply) NFPA 70, National electrical Code, Article 760 �• Manufacturer s instructions sp ify : Signed: Date: Organization: 4. Signaling Line Circuits Quantity and class of signaling line circuits connected to system (see NFPA 72 •le 6.6.1): Quantity: Style: Class: •� Quantity: Style: Class: Quantity: Style: Class: MC24 -2 -014 0806 Copynght NFPA AHJ - White; Owner - Canary; District - Pink; Site Copy - Goldenrod (NFPA 72, 2 of 4) 5. Alarm- Initiating Devices and Circuits Quantity and class of initiating device circuits (see NFPA 72, Table 6.5): Quantity: Style: Class: MANUAL (a) Manual stations: Noncoded Transmitters Coded Addressable (b) Combination manual fire alarm and guard s tour coded stations AUTOMATIC Coverage: Complete Partial Selective Nonrequired (a) Smoke Detectors Ion Photo K. Addressable (b) Duct detectors Ion Photo Addressable (c) Heat detectors FT RR FT /RR RC Addressable (d) Sprinkler waterflow indicators: Transmitters Noncoded Coded }( Addressable (e) The alarm verification feature is disabled or enabled , changed from seconds to seconds. (f) Other (list): 6. Supervisory Signal- Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD S TOUR (a) Coded Stations (b) Noncoded stations (c) Compulsory guard s tour system comprised of transmitter stations and intermediate stations Note: Combination devices are recorded under 5(b), Manual, and 6(a), Guard s Tour. SPRINKLER SYSTEM: Check if provided (a) Valve supervisory switches (b) Building temperature points (c) Site water temperature points (d) Site water supply level points Electric fire pump: (e) Fire pump power (f) Fire pump running (g) Phase reversal Engine- driven fire pump: (h) Selector in auto position (i) engine or control panel trouble (j) Fire pump running ENGINE - DRIVEN GENERATOR: (a) Selector in auto position (b) Control panel trouble (c) Transfer switches (d) Engine running Other supervisory function(s) (specify): b1C24 -2 -014 0806 Copyright NFPA AHJ - White; Owner - Canary; District - Pink; Site Copy - Goldenrod (NFPA 72, 3 of 4) • 7. Annunciator(s) Number: Type: Location: 8. Alarm Notification Appliances and Circuits NFPA 72, Chapter 6 — Emergency Voice /Alarm Service Quantity of voice /alarm channels: Single: Multiple: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: Quantity and class of notification appliance circuits connected to system (see NFPA 72, table 6.7): Quantity: I, Style: Class: PA Types and quantities of notification appliances installed: (a) Bells With Visible (b) Speakers With Visible (c) Horns With Visible (d) Chimes With Visible (e) Other With Visible (f) Visible appliances without audible: 9. System Power Supplies (a) Fire Alarm Control Panel: Nominal voltage: Current rating: Overcurrent protection: Type: Current rating: Location: (b) Secondary (standby): Storage battery: Amp -hour rating: Calculated capacity to drive system, in hours: Engine- driven generator dedicated to fire alarm system: Location of fuel storage: (c) Emergency system used as backup to primary power supply: Emergency system described in NFPA 70, Article 700: 10. Comments Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s) are: (signe• or 'tallation contractor /supplier (title) (date) • -- - fit-( 3.14 og (signed) for alarm service company (title) (date) (signed) for central station (title) (date) Upo completion of e system(s isfactory te-, (s) witnessed (if required by the authority having jurisdiction): _2 lilt O y signed) repres- tative of the u hority having jurisdiction (title) (date) MC24 -2 -014 0606 Copyright NFPA AHJ - White; Owner - Canary; District - Pink; Site Copy - Goldenrod (NFPA 72, 4 of 4) i t CO1F/re & r � . Simp /exGrihne // FIRE ALARM TEST /INSTALLATION • Security °• - ACKNOWLEDGEMENT CONTINUATION SHEET 1- 800-746 -7539 NAME r & • BOOK # CALL# // _ 11111 111111 • C 7O , -).k` ,VID ' ��G�'Y' J Vim ! / 2 Z(I PG OF . PERIPHERAL FUNCTION TEST DEVICE DEVICE LOCATION A • T n S NOTE ANNUN. ZONE ALARM ZONE DEVICE DEVICE LOCATION A T S NOTE ANNUN. ZONE ALARM ZONE TYPE L A U EN NO. OR OR TYPE L A O EN NO. OR OR S TELEPHONE SIGNAL TELEPHONE SIGNAL R R M BL I T e ZONE ZONE M LE T ZONE ZONE Alm • • • • • • • • • • • • • • PSD .= Photoelectric Smk Det PS = Manual Pull Station B = Bell Only TS = Tamper Switch • ISO = Ionization Smk Det CPS = Coded Pull Station H = Horn Only WF = Water Flow Sw • PDD = Photo. Duct Smk Det RR = Rate of Rise Ht Det C = Chime Only DH = Door Holder IDD = Ion. Duct Smk Det • HT = Fixed Temp Heat Det S = Spkr Only FP = Fire Phone DHS = Door Hldr & Sink.Det MD = Mercoid Heat Det ANr. =•Aud o.Vj ual PJ = Phone Jack SSD Smk Det FD =Flame De V� V'sual Only NCS = Nurse Call Sta. BD =Be Beam Det. Det. — — FAILURES AND SYSTEM DEVIATIONS FROM NFPA DADS: None • II As Follows (describe fully), 1 Ac.cr 203 Q • • • • AUTHORITY HAVING JURISDICTION MC24 -2 -005