Loading...
Report 626,7 o s (A.J 4. Form 2a Project Name: TI iz- Page: SUMMARY Project 1. Project Name TI f p- t2—T 2. Project Address U (k 9- 0 S N *.c►., t A �. 3. City/Town 5. County f\Stl i NG11 4. Building, Gross Area (ft2) 4 ,CE sF 6. No. of Floors I 7. Construction Site Elevation Above 2,000 ft? ❑ YES 1 2 < 6 Attached Chapter Type ID Description Attach Forms and Building Envelope Form 3a Building Envelope - General [►�' Worksheets 3b Prescriptive Path - All Climate Zones * CodeComp Report for Simplified Trade -off ❑ * In lieu of 3b * Floppy disc with .occ CodeComp file ❑ Check boxes to Worksheet 3a Wall U- factor ❑ indicate attached 3b Roof U- factor ❑ forms and 3c Floor U- factor ❑ worksheets 3d Window /Skylight Schedule ❑ Systems Form 4a Systems - General ❑ 4b Complex Systems ❑ r. Worksheet 4a Unitary Air Conditioners - Air Cooled ❑ 4b Unitary Air Cond. - Water & Evap Cooled ❑ 4c Unitary Heat Pump - Air Cooled ❑ 4d Unitary Heat Pump - Water Cooled ❑ 4e Packaged Terminal A.C. - Air Cooled ❑ 4f Packaged Terminal Heat Pump - Air Cooled ❑ 4g Water Chilling Pkgs - Water & Air Cooled ❑ 4h Heat Rejection Equipment ❑ 4i Boiler - Gas -Fired and Oil -Fired ❑ 4j Furnace & Unit Heaters - Gas and Oil -Fired ❑ 4k Simultaneous Heating and Cooling ❑ 41 Air Transport Energy ❑ 4m Natural Ventilation ❑ Lighting Form 5a Lighting - General ❑ 5b Interior Lighting Power - Tenant Method ❑ 5c Int. Ltng. Power - Space -by -Space Method ❑ Worksheet 5a Lighting Schedule ❑ 5b Interior Lighting Power ❑ Applicant 7. Name AN K i tl 10. Telephone 9e3.A { • 0 552- 8. Company M LDr N vs«N 612.eup 11. Date t I31 o g 9. Signature I 1111 • Attached No. of Pages Description of Documentation Document - ation 5u, elreiuve u nu uuo Form 3a Project Name: T1 Tor=— ' P Mai' -T Page: BUILDING ENVELOPE - GENERAL Check all boxes 1. Exceptions (Section 1312) that apply. ❑ No Envelope Components. The building plans do not call for new or altered building envelope components, e.g., walls, floors or roof /ceilings. ❑ A Non - conditioned Building. The proposed structure has no spaces heated or cooled by an HVAC system. Exceptions ❑ Exception. All new or altered building envelope components do not comply with the Discussion of qualifying requirements, Section 1312, but qualify for Exception: ❑ -1 ❑ -2 ❑ -3 ❑ -4 ❑ -5 exceptions in Portions of the building that qualify: instructions section. Plans /Specs Show compliance by The plans /specs show compliance in the following locations: including a drawing sheet, detail number, specification section 2. it Leakage (Section 1312.1.1) and /or subparagraph. Le Complies. Plans require penetrations in building envelope are sealed and windows and doors are caulked, gasketed or weatherstripped. The plans /specs show compliance in the following locations: t.'-Ivtit rs Nom DF -- Ti(S p-W tT 3. Syspended Ceiling (Section 1312.1.2.1) l'WComplies. Building plans do not show suspended ceilings used to separate conditioned space from unconditioned space. No exceptions permitted. 4. Recessed Light Fixtures (Section 1312.1.2.2) [ The building plans do not show recessed light fixtures installed in ceilings separating conditioned spaces from unconditioned spaces. ❑ Exception. The building plans require that fixtures installed in direct contact with insulation be insulation coverage (IC) rated. The plans /specs show compliance in the following locations: 5. Moisture Control (Section 1312.1.4) Urt'omplies. A one -perm vapor retarder is installed on the warm side (in winter) of all exterior floors, walls and ceilings, and a ground cover installed in the crawl space of both new and existing buildings where insulation is installed. The plans/specs show compliance in the following locations: ❑ Exception. All new or altered building envelope components do not comply with the vapor retarder requirements of the code, but qualify for an exception. Note applicable exception. Section 1312.1.4, Exception: ❑ -1 ❑ -2 Portions of the building that comply: Climate 6. Climate Zones Zones Zone 1 - A building site is in Climate Zone 1 if its elevation is less than 3000 feet above sea level and it is in one of the following counties: Benton, Columbia, Clackamas, Clatsop, Coos, Curry, Douglas, Jackson, Josephine, Lane, Lincoln, Linn, Marion, Multnomah, Polk, ° Tillamook, Yamhill, or."as in. o, ❑ Zone 2 - Building sites not in Zone 1, or where construction site elevation is 3000 feet or higher in Zone 1, are in Zone 2. 3 -1 Compliance with OSSC, effective 01/01105 Form 3b Project Name: Page: PRESCRIPTIVE PATH Part 1 of 4 CLIMATE Zone 0-1 or 0-2 (select one) Exterior Wall • Window Area Area Glazing Maximum Glazing (total rough frame ft2) (gross ft2) % Fraction Complies Glazing Conditioned Percent Space 134( + 5(12_5 .. 4 X 100 = )3.85 Calc- Semi - ulation Conditioned - X 100 = Space See instruction • section for a Conditioned discussion of glazing percent Mechanic - X 100 = • calculation. Penthouse • Windows Window Max Minimum Window - Shading Minimum From Work- (from Worksheet 3d) U- Factor Assembly (from Worksheet 3d) Coefficient Asse sheet 3d, place L�7/ the highest Overall Window U -Value Complies U - factor and P SC Compiles • highest Center Required of - Glass SC. Or Minimum Required Minimum check minimum Assembly (Fixed Assembly assembly and Windows) • identify window. Required Mini- mum Assembly (Operable Windows and Curtainwall) The plans /specs show window compliance in the following locations: +t�AIrJ t T Nar �r4ia - - pits - pPp.Nttil 4 6t - c - . Ca K s f 1 v�cT o N 't•' O cur.-1 F N Notes I From Worksheet 3d, place the highest Overall Window U- factor or check (Minimum Assembly). See "Window Requirements" in table on the following page for specific MA requirements. Excel version will automatically insert minimum assembly requirements or greatest U -value from 2. From Worksheet 3d, place the highest "center -of- glass" shading coefficient (SC) for glass or check MA (Minimum Assembly). See "Window Require- ments" in following table for specific MA requirements. Excel version will automatically insert minimum assembly requirements or greatest SC from Worksheet 3d. Shading Coefficient (SC) can be calculated from Solar Heat Gain Coefficient using the equation: SC = SHGC + 0.87. Manufacturers data may also be used to document SC. Walls R -Value Wall / Insulation Type Insulation Only U-Factor See instructions 1571 NC Cvi (.t w fc l L R- - ■ I or for a discussion of wall require- — ^ � 3s/6" t� t -ETAL '� N ,p Or ments. I 1;1241N6 vI E r� . W 'Tit 3 lZ " A-t • or [USIA l" ►4TICN or or or Below- R Grade Walls Insulation Only U-Factor See instructions Below -Grade Walls (Min. R -7.5) (Max. 0.11) r for a discussion of 9 ..,...., , requirements. or Ki4 .'" i I Notes 3 Submit Worksheet 3a for each calculated assembly U- factor Lebb. 3 -2 Compliance with OSSC, effective 01/01/05 • 4 I- . .. Form 3b Project Name: T1 'r °1 pint►4P—T Page: PRESCRIPTIVE PATH Part 2 of 4 Code Requirements - Zone 1 Discussion of these requirements in the instruction section. ZONE 1 Wall Requirements Window Requirements Max. Glazing max. R -Value Max. U- Shading Fraction' Wall / Insulation Type Insulation Only U- Factor Factor Coefficient Up to 15% CMU 'Masonry w /integral loose ftll insulation N/A or 0.300 Masonry or concrete w /cont. exterior insulation 1.4 or 0.300 0.540 0.57 CMU'Masonry w /integral rigid fill insulation N/A or 0.210 Masonry or concrete w /interior insulation 11 or 0.130 Up to 30% Masonry or concrete w /cont. exterior insulation 2.8 or 0.210 0.540' 0.57' Frame (wood or metal framing) 13 or 0.130 Other (provide short description) 13 or 0.130 CMU Masonry w /integral rigid fill insulation N/A or 0.210 Masonry or concrete w /interior insulation 11 or 0.130 Up to 40% Masonry or concrete w /cont. exterior insulation 2.8 or 0.210 0.3701° 0.3510 Frame (wood or metal framing) 13 or 0.130 Other (provide short description) 13 or 0.130 Code Requirements - Zone 2 Discussion of these requirements in the instruction section. ZONE 2 Wall Requirements Window Requirements Wall / Insulation Type Max Max. Glazing Max. U- R -Value U- Factor Shading Fraction Insulation Only Factor Coefficient Up to 15% CMU 'Masonry w /integral loose fill insulatio N/A Or 0.30 11 0.5711 Masonry or concrete w /cont. exterior insulation 1.8 or 0.270 0.500 0.57 CMU Masonry w /integral rigid fill insulation N/A or 0.160 Masonry or concrete w /interior insulation 13 or 0.090 Up to 25% Masonry or concrete w /cont. exterior insulation 4.3 or 0.160 0.500 0.57 Frame (wood or metal framing) 19 or 0.090 Other (provide short description) 19 or 0.090 CMU Masonry w /integral rigid fill insulation N/A or 0.160 , Masonry or concrete w /interior insulation 13 or 0.090 Up to 33% Masonry or concrete w /cont. exterior insulation 4.3 or 0.160 0.370 0.43 Frame (wood or metal framing) 19 or 0.090 Other (provide short description) 19 or 0.090 Notes 4 The Simplified Trade -off Approach must be used if glazing fraction exceeds allowable percentages. 5 Minimum weight of masonry and concrete walls = 45 lb/ft2 of wall face area 6 All cores to be filled. At least 50% of cores must be filled with vermiculite or equivalent fill insulation. 7 Prescriptive MA (Minimum Assembly) - For Fixed Windows: double - glazed window with a 0.5 inch air space, low-e coating and aluminum frame. MA shading coefficient description is a tinted outboard pane of glass. For Operable Windows or Curtainwall: double - glazed window with a 0.5 inch air space, low-e coating and thermally broken frame. MA shading coefficient description is a tinted outboard pane of glass. 6 All cores except bond beams must contain rigid insulation inserts approved for use in reinforced masonry walls • . 9 Batt insulation installed in metal or wood frame walls shall be insulated to the full depth of the cavity, up to 6 inches in depth. 10 Prescriptive MA (Minimum Assembly) - For Fixed Windows: double - glazed window with a 0.5 inch argon filled space, low-e coating (e <= 0.05) and thermal break frame. For Operable Windows or Curtainwall: only use Max U- Factor. MA shading coefficient description is a 0.25 - inch thick glass with low-e coating (e <= 0.05) with a tinted outboard pane. - ,, , � i ' 11 Prescriptive MA (Minimum Assembly) - For Fixed Windows: double - glazed window with a 0.5 inch air space, low -e coating and aluminum 4:9,144,14'.;/ .gr, - frame. For Operable Windows or Curtainwall: double - glazed window with a 0.5 inch air space, low- e coating (e<= 0.1) and thermally AI broken frame. MA maximum shading coefficient description is a tinted outboard pane of glass. Ji, 12 Prescriptive MA (Minimum Assembly) - For Fixed Windows, a double - glazed window with a 0.5 inch argon filled space, low -e coating (e <= � \'' •:� _ 0.05) and thermal break frame. For Operable Windows or Curtainwall, only use Max U- Factor. MA shading coefficient description is a 0.25 - �`" inch thick glass with low-e coating (e <= 0.05). 3 -3 Compliance with OSSC, effective 01/01/05 I- . , Form 3b Project Name: T( 4 F - 1-- +�l:›till't('"T Page: 0" PRESCRIPTIVE PATH Part 3 of 4 Roofs/ R -Value Ceilings Insulation Only U- Factor g Roof I Ceiling �� (Min. R -19) (Max. 0.050) See instructions for a dicussion of Z y P1 ' t D (WS pt L AT l o t.i j- i161 or roofs /ceilings. /� —4 3 of t t- A) 1Nt„, Shi E LL- LO MsT P-t/Let t o ts1 0 cuon N TS N t - - Of- `t is wt CT Notes " Write -in a short descripti f or assembly with t owest insw Lion R -value or the highest assembly U- factor. 12 Submit Worksheet 3b for each calculated roof /ceiling assembly U- factor. Skylight Area . Roof Area Skylight Maximum • ght total rough frame ft2) (gross ft2) % 13 Fra • Complies Skylights Conditioned a id Includes glazed Space + X 100 = smoke vents. - Semi • See instructions Conditioned + . X 100 = for a dicussion of skylights. Space Conditioned Mechanical ' + X 100 = Penthouse Skylight Area (total rough Roof /Ceiling Area Skylight frame ft2) (gross ft2) Percent Skylights Sky t Max Minimum Skylights Shadi • From Worksheet from Worksheet 3d ' . .1 Assembl 3d, place highest _ Ism Worksheet 3d) Assembly_ Overall Vertical 0 Window U- factor . and highest U - Value Complies SC Complies Center - of - Glass SC. Required Required Minimum Minimu i• sembl Assembly The plans /specs show window compliance in the following locations: Code Compliance Thermal Performance Shading Coefficient Require- Option Overall Vertical U- Factor Center of Glass SC Performance U -1.230 for overall assembly in overhead plane SC -0.47 center -of -glass meats Min. Assembly Double glazed, 0.5 -inch airspace N/A I (MA) Notes 13 Skylight percentage area is based on total skylight and smoke vent rough frame area divided by total conditioned roof area. Percentage must not exceed 6 percent of total roof /ceiling area in conditioned building space. The Simplified Trade -off Approach must be used if glazing fraction exceeds allowable percentages. 14 From Worksheet 3d, place the highest Overall Vertical U- factor or write -in MA (Minimum Assembly). See "Skylight Requirements" in table above for specific MA requirements. 15 From Worksheet 3e, place the highest "center -of- glass" shading coefficient (SC) for glass. See "Skylight Requirements" in table above for specific MA requirements. Shading Coefficient (SC) can be calculated from the Solar Heat Gain Coefficient using the equation: SC = SHGC " -" ; ? r p � 0.87. Manufacturers data may also be used to document SC. r! 1� , N._.;:„,:://.,• 3-4 Compliance with OSSC, effective 01/01/05 Form 3b Project Name: I l - T ©R Tler M AR-T Page: • PRESCRIPTIVE PATH Part 4 of 4 Floors R•Value See instructions Floors over Unconditioned Spaces 16 Insulation Only U- Factor for a dicussion of floors. N I PI or R -Value Heated Concrete Slab Edge Insulation Only Heated Slab -on -Grade (Section 1312.1.2.4) ❑ Complies. Building plans show insulation extending downward from the top of the slab a minimum distance of 24 inches or downward and under the slab for a combined minimum distance of 24 inches or to the bottom of the thickened edge of the of slabs used as a foundation. The plans /specs show compliance in the following locations: Notes 16 Write -in a short description for assembly with the lowest insulation R -value or the highest assembly U- factor. t7 Submit Worksheet 3c for each calculated floor assembly U- factor. 16 Write -in a short description for Heated Slab, which has heat, integrated into slab such as hydronic heat. If more than one floor type, enter the lowest insulation R -value or the highest component U- factor of any floor. Code Compliance Options Require- Min. R -Value Max. U- Component Insulation Only Factor meats Floor over Unconditioned Spaces 11 or 0.070 Climate Climate Component Zone 1 Zone 2 Heated Concrete Slab Edge, Min. R -Value 7.5 or I 10.0 Doors U- Factor R -Value Center -of- See instructions Doors Insulation Only Panel for a dicussion of a o ue, with leaf width greater than 4' doors. opaque, g {Min. R -5) (Max. 0.20) N { f- or Not 19 Write a short description tor Uoors. It more than one door type, enter the lowest insulation K -value or the nignest center -ot- panel U- factor of any door. The following doors are exempt from door and window U- factor and shading coefficient reduirement 3 -5 Compliance with OSSC, effective 01/01/05