Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Specifications (2)
e ?../ocD7 '06 3 33 60,7C3 Si() � Simplex LifeAlarm Fire Alarm Control Panels UL, ULC Listed; FM, CSFM, 4006 Series Fire Alarm Control Panels and MEA (NYC) Approved* Providing up to Ten IDCs and Four NACs a 1,I111111111111il 111119i1111111111111111I111IC1 ` :, $fir ya Control panel operator convenience features: • Wide viewing angle 2 x 20 (40 character) alphanumeric g g ( P • LCD and dedicated LEDs provide convenient panel , F, , status information •`': • Operation is programmable using a multi- function " > rJ keypad and the panel LCD or via service computer (PC) • -� upload/download PC RS �3� service port provides upload/d '" ;�'�,,° • °'' access for panel configuration and event history logs " • Software updates are via PC download l gppg fire alarm conhcl � ; • Convenient library of standard custom label terms ,: ' {III11111111111, 111111111111 ,1 `_ • Standard on -board DACT provides: Contact ID, 3/1, 4/2, BFSK, and SIA formats --> 4006 -9101 Standard Control Panel • WALKTESTTM silent or audible system test ** • Voltage and current for both the battery charger and the ��IIIIIIII1l1I111111N11111I11I11116Illllll }111t1111�� ��� battery can be displayed at the front panel LCD ~� Five Standard Initiating Device Circuits (IDCs): r = art° , tv4: _1 • Five Class B IDCs with optional expansion to ten, all ' teat `:. with individual zone disable y . ` • Monitor 2 -wire or 4 -wire initiating devices including 0,114;,' TrueAlarm smoke detectors z.:_;:? • • Optional Class A Adapter Module ' = " IMMOINIttit '' Two Standard Notification Appliance Circuits :kitty td Z itaara i (NACs): 1 `4006 FireyAarmCantrof; smi+ • Class A or Class B outputs with solid state overcurrent 4I ( I1111111II1I 111I(IlLf1;1111I llEllI1'II,I$ ` protection per NAC, each rated for 2 A • Selectable for Simplex SmartSyncTM two -wire 4006 -9121 Control Panel with 24 LED Annunciator horn/strobe control or synchronized strobe controlt Standard Power Supply: Available option modules (Continued): • Provides 3 A maximum @ nominal 24 DC • Expansion IDC module with five Class B IDCs • Automatic input power selection operates with 120 VAC • Class A IDC Adapter Module, City Interface Module, or 240 VAC, 50 or 60 Hz and Auxiliary Relay Module • On -board temperature compensated battery charger for • Remote LCD and LED /Switch Annunciators up to 12.7 Ah batteries in cabinet (UL and ULC) and up to 25 Ah batteries in separate cabinet (UL only) D @SCIh�t101 Additional standard features: For areas requiring from five to ten initiating zones, the • Two auxiliary relays Simplex 4006 Series fire alarm control panels provide flexible • IDCs, NACs and Relay outputs are power limited per initiating circuit monitoring, extensive programmable control NFPA 72 (AC input, battery circuits, and City Circuit capability, and LCD annunciated circuit - specific 20 character Module outputs are non -power limited) custom labels. • UL listed to Standard UL 864, 9th Edition * See page 2 for additional ULC and MEA information. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165- 0026:318 for allowable values and /or Available option modules: conditions concerning material presented in this document. It is subject to re- examination, (standard on ULC revision, and possible cancellation. Additional listings may be applicable, contact your local • Door mounted 24 LED annunciator ( Simplex® product supplier for the latest status Listings and approvals under Simplex Time models) Recorder Co. are the property of Tyco Safety Products Westminster. WALKTEST system testis protected under US Patent No. 4,725,818. • 3 A Expansion Power Supply with two on -board 2 A NACs that operate the same as standard NACs t SmartSync horn /strobe operation is protected under U.S. Patent No. 6,281,789. P Two -wire synchronization circuit operation is protected by U.S. patent No. 5,559,492. S4006- 0001 -3 7/2005 Standard Featu ref DetaIIse S tandard Feature k,Det04.0.o ntin IPPT! Five Class B IDCs are each capable of supporting up to Power Supply and Battery Charger. DC power 30 Simplex current - limited smoke detectors or electronic output is 3 A @ 24 VDC for panel use. The temperature heat detectors (see list on page 4) as well as manual stations compensated battery charger (sealed lead -acid batteries and other compatible contact closure initiating devices. only) is rated for up to 25 Ah batteries per UL 864 and up IDCs are capable of Class A operation with an optional to 12.7 Ah per ULC -S527. (Up to 12.7 Ah batteries fit in adapter module and can be programmed as Style C (short or the cabinet, larger batteries require an external cabinet.) open initiates a trouble) for use with current limited devices Panel electronics can measure and display voltage and only current for the power supply, batteries and the battery Two, 2 A On -Board NACs provide conventional reverse charger (standard and expansion power supply). Depleted polarity operation, selectable as Class A or Class B, with battery trouble is monitored and annunciated and depleted electronic control and overcurrent protection. Operation is battery cutout can be selected. Active battery status selectable for synchronized strobe or SmartSyncTM monitor supervises charger operation. horn/strobe two -wire operation. Horn control can be selected DptiOnah,Featu f e PDe ta(Is at the panel for: Temporal pattern coding, Steady On, Slow March Time (20 beats per minute), or Fast March Time Expansion Power Supply. Provides 3 A total @ (120 beats per minute). Note: When selected for SmartSync 24 VDC, two additional 2 A NACs, and an additional horn/strobe control, March Time produces 60 beats per auxiliary power output of 500 mA. Output operation is the minute. same as on the standard power supply. The 24 VDC Auxiliary output provides up to 500 mA Expansion IDC Module. Provides 5 additional Class B for system use. (Auxiliary output current is counted for IDCs with operation the same as the standard IDCs. total power supply capacity.) Expansion Relay Module. Provides 10 programmable Standard Auxiliary Relay Outputs. Two relay relays, jumper selectable as N.O. or N.C. Contacts are outputs are available, selectable as normally open or rated 2 A @ 30 VDC. Typical application is to track normally closed, rated 2 A @ 30 VDC per below: status of each IDC. See page 7 for relay program options. Aux Relay 1 is normally assigned to General Alarm Class A Adapter Module. Converts 5 IDCs from operation but is programmable (see page 7) Class B to Class A operation. Two modules can be Aux Relay 2 (Trouble) is energized when Normal and is mounted for use with the Expansion IDC Module. de- energized with a Trouble condition. City Circuit Modules. These modules are available On -Board Dual Line DACT. Operation can be selected with or without on -board disconnect switches, depending for Contact ID, SIA, 3/1, 4/2, and BFSK formats. on local requirements (either type can be disconnected Reporting includes Alarm, Supervisory, Trouble, and AC through the front panel under password control). Failure. Operation includes automatic 24 hour test and Connections are for Remote Station (reverse polarity) or programmable power fail report delay. Municipal Master (local energy). Reporting includes Alarm, Supervisory, and Trouble. Product Selection Control Panel Model ; Description Listings . Box Depth Standard , Features-,' , 4006 -9101 Standard fire alarm control panel MEA 4 -1/4" Red cabinet; 5 Class B IDCs, 2 Class B /Class A UL, FM, (108 mm) NACs, 3 A power supply with battery charger; 4006-9121 Fire alarm control panel with & CSFM ULC 4-5/8" on -board DACT; for input voltage of 24 LED Annunciator on front door (117 mm) 120/240 VAC, 50/60 Hz (autoselect) Option Modules Model:; : Description 4006 -9801 Expansion Power Supply; 3 A, with 2 NACs, 120/240 VAC, 50/60 Hz 4006 -9802 Expansion IDC Module; 5 Class B IDCs Select up to one of each as required 4006 -9803 Expansion Relay Module; 10 relays selectable as either N.O. or N. C. 4006 -9804 Class A Adapter Module; converts 5 IDCs from Class B to Class A Select up to two maximum 4006 -9805 City Circuit Module with disconnect switch Select one if required 4006 -9806 City Circuit Module without disconnect switch Accessories -Model _:Description „ , 2975 -9812 Red semi -flush trim kit; 1- 7/16" (37 mm) wide; includes four corners and trim pieces for top, bottom, and sides 4009 -9801 Beige External Battery Cabinet for up to 25 Ah batteries; mounts close - nippled to control panel cabinet; dimensions = 16 -1/4" W x 13 -1/2" H x 5 -3/4" D (413 mm x 343 mm x 146 mm) [depth increased for 25 Ah effective 7/2005] Batteries, 1 2 Volt (select one battery model per system standby requirements; order quantity of two) Model , Size Model; Size e:.Locatiori ; .'.. Model _ `.Size :Location` ; . ': . 2081 -9272 6.2 Ah 2081 -9288 12.7 Ah 2081 -9275 18 Ah Requires 4009 -9801 External Battery 2081 -9274 10 Ah For cabinet mount 2081 -9827 25 Ah Cabinet (UL listed only) 2 S4006- 0001 -3 7/2005 'Ke `board Reference FIVE STATUS INDICATOR LEDs provide system status indications in • addition to LCD information, LEDs flash to indicate the condition and then when acknowledged, remain on until reset i THREE PROGRAMMABLE LEDs 2 X 20 LCD READOUT, LED backlighted during normal conditions and abnormal provide custom labeling (labels insert into operating conditions, provides up to 20 characters for custom label information a pocket), the top two LEDs are FIRST ALARM DISPLAY: Operation can be selected for maintained display of first selectable as red or yellow, the bottom alarm until acknowledged LED is selectable as green or yellow .�'6,�05 t:»,'. crwx , n.. - w*ms SYSTEM NORMAL = 12: 35: 1 P 06/03/05 ° F 'CONTROL Ra Y PANEL VIEW SYSTEM RESET restores � � �?;.��� � ,� n ."iEu: "S:"�', -3., s ¢� . 4. , ...:x �` F3 ..' •a 3 ; s g ;:. control p anel to normal when with door closed * ty , s to �� all alarmed inputs are c s AIARM F } SUPY ST f •n uuaE` • AIARM 4SYSTEM ' t u s c - returned to normal * �ACN ACN ACN SRENCE RESET e F" r ALARM ACK acknowledges a Are �F ti�a �fi ��r�'# " Alarm condition, to s the the operator �' � � � rr acknowledge, silences a h r ALPHANUMERIC , panel and all annunciator tone - alerts, �i E•� KEY p rovides p c: c z � r programming entry of and steps through the active Alarm list p g t ? $' numbers and letters SUPV ACK acknowledges system supervisory conditions, logs the r:g r acknowledge, silences the operator i ''' ` "`` ' i�`�'�' - panel and all annunciator tone- alerts, and steps through the active ALARM SILENCE causes audible notifi cation appliances , Supervisory list TROUBLE ACK acknowledges to be silenced, used after evacuation is complete and system troubles, logs the while alarm source is being investigated FIVE NAVIGATION KEYS: MENU selects acknowledge, silences the the on- screen programming menu; left operator panel and all annunciator and right arrows moves the position on the tone - alerts, and steps through the FOUR EXTENDED FUNCTION KEYS: ENTER confirms screen, and PREVIOUS and NEXT active Trouble list selections, EXIT /CLEAR backs out of the present screen menu navigate screen selections and clears information that has not been entered, FUNCTION enables the active function menu, DISABLE /ENABLE toggles the function or circuit status as appropriate per the selected screen • - Door�LED�Aninunciator�Detalls� (RED LED) YELLOW LED • �,rre.- laTm �fAn°n•u »ata•tar" A � �o. � ,�,. � � , < IDC 1 IDC 5 IDC 9 IDC2 IDC6 • t IDC10 t •: • NAC1 •[",'� IDC 3 IDC 7 sr t •: kJ; NAC2 9 •, NAC • ," IDC 4 �? IDC 8 • NAC 4 ' 14 CUSTOM LABEL AREAS are available, typically for IDC and NAC annunciation (shown labeled for reference, blank FOUR YELLOW LEDs provide labels are provided); dual LED locations have a Red LED default NAC Trouble annunciation (top) and a Yellow LED (bottom); labels insert into pockets (shown labeled as NAC 1 -4) behind the overlay; LED operation is programmable to track other monitored status conditions 3 S4006- 0001 -3 7/2005 -rs. y �y- .. � t ti r ,. „.� S ieClfitations„( Refer36- installatioronstructions 579 704,406dalt mfOrnOlon),, Power Ratings Input Voltage 120 VAC, 60 Hz; 220/230/240 VAC, 50/60 Hz, auto - select AC Input Ratings Input Current, Standard 2 A maximum @ 120 VAC input; 1.5 A maximum @ 240 VAC input Input Current with 4 A maximum @ 120 VAC input; 3 A maximum @ 240 VAC input Expansion Power Supply Power Supply Output Rating 3 A maximum © 24 VDC in alarm (see NAC details on page 6) Battery Charger Temperature compensated charger is rated for up to 25 Ah per UL 864; up to 12.7 Ah per ULC -S527 Standby Current 130 mA; with 5 IDCs fully loaded, tone -alert silenced, trouble LED on • Standard Circuit Ratings.(NOTE Total DC = 3 A maximum)„ Notification Appliance Circuits (NAGS) 2 A maximum @ 24 VDC, per circuit; available as Class A or Class B; NOTE: See details on page 6 Class B end -of -line resistor = 10 kQ2, 1/2 W; Model 4081 -9008 (P /N 733 -894) Supervisory Current 3 mA maximum Initiating Device Alarm Current 60 mA maximum Circuits (IDCs) Ca acit Each IDC supports up to 30 detectors (smoke or electronic heat) and manual p y stations as required; wiring distance is limited to 50 0 maximum End -of -Line Resistor 3.3 kO, 1/2 W; Model 4081 -9002 (P /N 733 -893) for Class B IDCs Quantity Supported Up to four annunciator modules per panel (see page 5 for details) Wiring Type Twisted pair,'or.twisted, shielded pair; 18 AWG (0.82 mm Bus -Style Wiring Up to 4000 ft (1219 m); 0.58 pF (580 nF) maximum capacitance; 35 0 max. Annunciator "T -Tap” Wiring Up to 10,000 ft (3048 m) total wiring; up to 2500 ft (762 m) to farthest device Communications Bus - style, connect one at panel 100 0, 1/2 W; 4081 -9011; Line Matching Resistor T -Tap, connect one at panel and one at end of line (p art number 733-974) ) Suppression Use 2081 -9044 Overvoltage Protectors where wiring leaves and enters a building (refer to data sheet S2081 -0016) Auxiliary Power Output 500 mA maximum @ 24 VDC Standard Auxiliary Relay Outputs Relay 1 Programmable operation Contacts rated 2 A @ 30 VDC, 0.35 power factor; Relay 2 Trouble operation jumper selectable as N.O. or N.C. Wiring Connections for Above Circuits and Terminals rated for 18 AWG to 12 AWG (0.82 mm to 3.31 mm ) AC Input Option`Module'Ratings:' • -• Class A IDC Adapter Module Five circuits per module, rated same as circuits Ten Relay Auxiliary Contact Ratings 2 A @ 30 VDC, 0.35 power factor; jumper selectable as N.O. or N.C. Module 4006 -9803 Wiring Terminals rated for 18 AWG to 12 AWG (0.82 mm to 3.31 mm Environmental Ratings - ;- E Operating Temperature Range 32° to 120 °F (0° to 49° C) Operating Humidity Range Up to 93% RH, non - condensing @ 100.4° F (38° C) maximum Reference lnfor;matioti Com o atl ,, 'Iez Pe i : 1,, 1 Compatible Simplex Detectors • Model';, Type D escription;:" ...,, .....,. - Data Sheet 4098 -960 Standard detector (2.8% nominal) S4098 -0015 4098 -9605 Photoelectric smoke detectors Reduced sensitivity detector (3.5% nominal) for 2 -wire and 4 -wire bases 4098 -9602 Combination smoke and heat detector S4098 -0017 4098 Series Duct detector housings 2 -wire and 4 -wire models S4098 -0029 4098 Series Ionization Smoke Detectors 2 -wire and 4 -wire models S4098 -0018 4098-9612 135° F (57 °C) Fixed temperature heat detector 4098 -9614 Electronic heat detectors for 200° F (93 °C) S4098-0014 4098 -9613 2 -wire and 4 -wire bases 135° F (57 °C) Fixed temperature heat detector with 4098 -9615 200° F (93 °C) rate -of -rise detection Compatible System Expansion Panels Model Type : Description: Data Sheet y Provides a remote voice control panel with on -board NACs, internal 4003 Series Voice Control Panel S4003 -0001 microphone, and remote microphone input 4009 Series Remote NAC Extender Provides remote NACs; includes power supply and battery charger; S4009 -0002 4 extenders max/NAC; 4006 uses NAC output to provide control Note: Contact your local Simplex Product Supplier for additional compatible peripherals. 4 S4006- 0001 -3 7/2005 Su " %.erviso" an- nd -Alarm Currents,. Model Module Supervisory Alarm 160 4006 -9101 Standard fire alarm control panel 130 mA per mA + 60 mA per IDC in Alarm 4006 -9121 Control panel with 24 LED Annunciator 148 mA 210 mA + 60 mA per IDC in Alarm 4006 -9801 Expansion Power Supply 50 mA 60 mA 50 mA 4006 -9802 Expansion IDC Module 50 mA + 60 mA per IDC in Alarm 4006 -9803 Expansion Relay Module 0 mA 0 mA + 10 mA per energized relay + 10 mA per energized relay • 4006 -9804 Five Circuit IDC Class A Adapter 0 mA normal; 0 mA normal; 10 mA per IDC in trouble 10 mA per IDC in trouble 4006 -9805 City Circuit Module with disconnect switch 30 mA 60 mA 4006 -9806 City Circuit Module without disconnect switch 30 mA 60 mA 4606 -9101 Remote LCD Annunciator (see data sheet 100 mA 150 mA S4606 -0001) 4610-9111 Remote LED /Switch Annunciator (see data 40 mA 70 mA sheet S4610 -0001) (all LEDs and tone -alert on) "" Current Calculation Information: 1. To determine total supervisory current, add currents of modules in panel to base system value and all auxiliary loads. 2. To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel NAC loads and all auxiliary loads. Remote Annunciat& O •tionss The 4006 supports up to four annunciator options 4606 -9101 LCD Annunciator Features: including: • LCD readout with two lines of 40 characters each and • Door Mounted 24 LED Annunciator LED backlighting • 4610 -9111 Remote LED /Switch Annunciators • Wide viewing angle, super -twist design • 4606-9101 Remote LCD Annunciators • Keyswitch access controlled Annunciators communicate at a rate of 9600 baud with Control switches and status LEDs for: 24 VDC power supplied by separate wiring. • Alarm, supervisory, or trouble acknowledge 4610 -9111 LED Annunciator Features: • Alarm silence and System Reset • 16 LEDs with programmable functions and dedicated Three programmable LED indicators: LEDs for Alarm Silenced, Lost Communications, Trouble, and Power -on • Two LEDs are selectable as red or yellow • • Keyswitch access controlled switches for One LED is selectable as green or yellow Acknowledge, Alarm Silence, Reset, and Lamp Test • With provisions for custom labeling • Local tone -alert ., j "rK i. ro''°;;a.'.3: �•: - .xj 3 , ..B2ys C',� a) � t. G .f >' urx, -. - >:x .FS =t=it -}iF - .; • {k r�i'd f Fi e• AlnrmK "A ncl"to r 4 _ . ,, SYSTEM IS NORMAL 1 15 am MON 20 DEC 04 �L .:s , i:. .�tii. 11 j } • _ g a, a) Simplex 4610 -9111 LED /Switch Annunciator 4606 -9101 LCD Annunciator 5 S4006- 0001 -3 7/2005 IDC O erat on Modes, The following IDC operation modes are selectable from either the front panel or the PC programmer Function Type Description Device State IDC Status Normal = NORMAL FIRE Fire monitor zone Current Limited = FIRE Short = FIRE Open = TROUBLE WATER Waterflow monitor zone HEAT Heat detector zone Normal = NORMAL Current Limited = FIRE DUCT Duct detector zone Short = FIRE PULL Manual (pull) station zone Open = TROUBLE SMOKE Smoke detector zone Normal = NORMAL SO Sprinkler Supervisory Current Limited = SUPERVISORY Short = SUPERVISORY Open = TROUBLE Normal = NORMAL WSO Combination waterfow and water supervisory Current Limited = SUPERVISORY zone Short = ALARM Open = TROUBLE Normal = NORMAL SUPV Supervisory monitor Current Limited = SUPERVISORY Short = SUPERVISORY Open = TROUBLE Normal = OFF UTIL Supervised utility monitor Current Limited = ON Short = ON Open = TROUBLE Normal = NORMAL TROUBLE Trouble monitor Current Limited = TROUBLE • Short = TROUBLE Open = TROUBLE Normal = NORMAL Verified fire alarm; the abnormal (current limited) Current Limited = VERIFY VSMOKE state causes the alarm verification cycle to start; Short - FIRE a short is an immediate alarm Open = TROUBLE Normal = NORMAL STYLEC Style C fire monitor Current Limited = FIRE Short = TROUBLE Open = TROUBLE Normal = NORMAL LATSUPV Latching supervisory monitor (supervisory Current Limited = SUPERVISORY latches until system is reset) Short = SUPERVISORY Open = TROUBLE Detailed NAC Ravin � ss - NAC'. Rafings Maximum "per NAC. " " Appliances - Simplex 4901 Series (horns) and the following 4906 Series Multi- Candela: strobes, Special Application: 2 A; horn /strobes, and speaker /strobes (see data sheets S4906 -0001, S4906 -0002, & strobe synchronization is UL listed across all S4906 -0003 ) 4 system NACs for these 4906 Series 4906 -9101 4906 -9103 4906 -9127 4906 -9129 4906 -9151 4906 -9154 appliances 4906 -9102 4906 -9104 4906 -9128 4906 -9130 4906 -9153 Regulated 24 VDC: 1_5 A NOTE: Maximum strobe load on main power supply or expansion power supply is 1.35 A All other UL Listed Notification Appliances; use associated external per power supply (2.7 A total); remainder of synchronization modules where required power supply rating is available for other loading 6 S4006- 0001 -3 7/2005 • Rela r O o eratioriModes, The following relay operations are selectable from either the front panel or the PC programmer. Common Fire Alarm Operations Function'Type Relay Activates Upon Relay Deactivates Upon SRELAY General Alarm Silence RRELAY General Alarm Reset • SUPV Supervisory condition Clear TRBL Trouble condition Acknowledged Special Functions 'Function Type Description UTILITY Utility IDC in the same alarm group activates PRIMARY General alarm; relay is tied to Primary Elevator Recall contacts ALTERN General alarm; relay is tied to Alternate Elevator Recall contacts DRESET Relay provides 24 VDC power to 4 -wire detectors; relay turns off for 5 seconds on System Reset DHOLDER Relay provides 24 VDC to larger door holder relay with separate power source; relay activates on general alarm to remove power to door holder relay and close doors Addit itotIO Pro 9 ramm n ∎ Feature'Details ,Function ",� � Details; 't ` Custom labels Up to 20 characters per point; a built -in message library provides for commonly used words for easy front panel programming For front panel label creation convenience, the following words can be selected as part of a custom label ( _designates a built -in space; typing the first letter of a word /number will select the closest word in alphabetical /numerical sequence) Basement Message Library North Center Flr_3 Floor Lobby main Boiler_RM Elevator South rear Office first Classroom Entrance Storeroom East 5th Flr_4 Garage Patient 2nd Closet_ Restroom Wing West Flr_1 RM 5 HVAC_Room upper 3rd Corridor Room Zone Front Flr_2 — Kitchen lower 4th Elect RM Stairway Three separate logs: Alarm (100 entries), Supervisory (100 entries), and Trouble (300 entries); logs can be History logs queried separately, or as a combined log; logs can be downloaded for printing or archiving using the RS -232 service port Automatically scans system for installed option modules and configures panel programming accordingly; Autoprogram modes are available to detect new modules only, recreate default programming and then add all modules found Alarm Groups Up to 99 alarm groups are available, any point may be in up to 3 alarm groups; this allows NAC and relay operation to be associated with IDC inputs according to local response requirements WALKTEST Allows one person to perform system testing; alarm or trouble tests are followed by automatic reset; the alarm zone is sounded out by associated audible notification or the response is silently logged into the Alarm log Manual Control Allows selection of individual relays or NACs for system testing Level 1 = Acknowledge, Silence, System Reset, View logs, View point information, and Lamp Test Passcode Level 2 = All Level 1 + Set Time /Date, Point Control, Enable /Disable points Protection (4 -digit number) Level 3 = All Level 2 + Clear logs, Clear verification tallies, Custom label editing, and WALKTEST Level 4 = All Level 3 + Programming, Upload /Download; this is the Service access level 7 S4006- 0001 -3 7/2005 Insfallation „and Module iii ernent k ferelnce 1 -4--- -Box width 15 -5/8” (397 mm) ®l (Top and side views are Knockouts are shown with door installed) located on top and sides O 0 0 0 0 Box depth = ,I 4 -1/4" (108 mm) standard 4 -5/8" (117 mm) w /annunciator door t IDC Expansion ) E1 I I a-- 11 -1/4" (286 mm) > , Module* f (Main board a 1 (A 8 0 Class A -.\ Adapter Relay 'Ir® _�., _ . - , o: _: Modules* to o Expansion ' yr ! Module* I r, Door thickness I I ®0 o 5/8" (16 mm) 1 d t 3oo1 Z, El E) 0 l2 o� r = 1 Di s l a 16" 13 -1/2" p y 1 a Q = tl Assembl J C� ® ®�i "' (343 mm) I` y O O 4 E nen , (406 mm) j f, A O O r1 l [l o M1: \ [dl 1 P Main board , Y v ® J a p Expansion IP I. Power Supply" (AC Input Terminal City M *) (extends under IDC Expansion II 'N Module space) Battery Area x O ® No conduit or wiring in this area 1'4 13 -1/4" (337 mm) IP-I 41011 NOTE: For semi -flush mounting, cabinet * Indicates optional modules must extend 1 -1/2" (38 mm) - minimum from wall surface Tyco. Simplex, the Simplex logo. TrueAlarm, WALKTEST, and Smar7Svnc are trademarks of Tvco International Services AG or its affiliates in the U S and /or other countries. NFPA 72 and rational Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA) �� ��� Tyco Safety Products Westminster • Westminster, MA • 01441 -0001 • USA S4006- 0001 -3 7/2005 ® www.tycosafetyproducts -use wm.com C 2005 Tvco Safety Products Westminster All rights reserved All specifications and other inf rrmation shown were Cu, as ofdocument revision date a are subject to change without notice • ® 0Mp ex Fire Alarm Control Panel Accessories Listings* System Batteries, Sealed Lead -Acid; with Applications Reference for Battery Cabinets, and Battery Cabinets with Charger Features Rechargeable, sealed lead -acid batteries: `_ .. • Lead - calcium rid structure with immobilized g electrolyte in absorbent separator a �g • Low maintenance with no need to add water : 11 f • Low self - discharge characteristics • One - piece, high impact polystyrene cell cover with high reliability dual seal construction . • UL 924 recognized pressure relief valves "' • Available in a variety of capacities: r' • Batteries for internal mounting range from 6.2 Ah up to • • its 50 Ah, depending on control panel cabinet size �� €��� -� , �� X JI • Larger batteries, up to 110 Ah, mount in external battery 4100 cabinets that are available with internal chargers l� �. - • Includes battery chargers with communications 3 ✓a compatibility for use with 4010 Series fire alarm control - panels and with 4100U Series fire alarm control panels . t4 J .uti4' Descn ;1i 6 Simplex rechargeable sealed -lead acid batteries provide Compatible Sealed Lead Acid Batteries can be reliable and repeatable discharge and recharge Installed Inside Fire Alarm Control Panel Cabinets characteristics for use in fire alarm and other systems ;,,;;, 4 .....:,..., • ; ,",- ,..AM; applications. They are designed with immobilized Ake electrolyte in an absorbent separator, allowing them to a , � 4 �s provide rated capacity on the first cycle. _ Because of their sealed construction, packaging is allowed g� within the system electronics enclosure (see illustration s - on page 2). When this is applicable, the quantity of x system cabinets and the battery wiring distances are both . �� minimized. Where required, external battery cabinets can be close - nippled to the control panel to house larger Remote Battery Cabinets are Available for batteries with battery chargers available in some battery Larger Battery Requirements cabinet sizes. Bate 1Details' Battery.Deta li. (Con'tinued) Charging. These batteries are intended to be used with s ro Disposal. Battery chemicals and materials can be g g' recycled. Refer to information shipped with the battery or compatible Simplex battery chargers. on its case. Return to the battery manufacturer or to a Series Connections. These batteries are required to be similarly qualified battery processing facility for proper connected in series to produce 24 V system voltage. disposal. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. * Refer to details on page 4 and to the referenced individual product data Testing. Battery capacity testing is recommended to be sheets for agency listing status of battery cabinets and chargers. The batteries performed by using a sealed lead -acid battery tester detailed in this document meet the requirements of UL, ULC, and Factory designed to withdraw a minimum of battery charge. The Mutual for use with respective equipment battery chargers as listed on page 3. Contact your local Simplex product supplier for proper battery selection per preferred tester applies a variety of amplitude and system requirements. Listings and approvals under Simplex Time Recorder duration controlled test pulses that compares terminal Co. are the property of Tyco Safety Products Westminster. voltage against those predicted for the specific battery size. (Testing is available through your local Simplex product supplier.) S2081- 0006 -18 5/2007 • Batt , Constr Jctton,ReferenceT Actual appearance will vary with battery size. Sealed outer cover Quick connect or post type terminal Vent hole (type varies with battery size) Potting material, black for negative, red for positive • • (polarity is also clearly marked with + and -) 1111111111111 Pressure relief valve Inner cover ►ice , Absorbent separator used to immobilize electrolyte I RV ' I� Semi - permeable Lead - calcium grids 0 membrane separator Cell group dir or Cell case (high impact polystyrene) Oitte Size4S • ecificat ons Discharge Rate :: Terminals. • • App mat . Weight t N Capacity @ 20 Hour H g .. .Battery ModeL,� - g Width Depth e' >. 2081 -9272 6.2 Ah 6 -1/8" (156 mm) 2 -5/8" (67 mm) 4" (102 mm) 5.75 lbs (2.6 kg) 2081 -9274 10 Ah 6" (153 mm) 4- 1/16" (103 mm) 4" (102 mm) 9.2 lbs (4.2 kg) 2081 -9288 12.7 Ah 6" (153 mm) 4" (102 mm) 4" (102 mm) 9lbs (4.1 kg) 2081 -9275 18 Ah 7 -1/4" (184 mm) 3 -3/8" (86 mm) 6 -5/8" (168 mm) 14.3 lbs (6.5 kg) 2081 -9287 25 Ah 6 -5/8" (168 mm) 5" (127 mm) 7" (178 mm) 19.4 lbs (8.8 kg) 2081 -9271 (rectangular case, 33 Ah 12 -1/2" (318 mm) 3 -3/8" (86 mm) 7- 1/16" (179 mm) 26.6 lbs (12.1 kg) typically for service) 2081 -9276 ( "square" case, 33 Ah 7 -3/4" (197 mm) 5 -1/4" (133 mm) 6 -3/4" (171 mm) 26.5 lbs (12 kg) use for new) 2081 -9296 50 Ah 9 -1/2" (241 mm) 5 -1/2" (140 mm) 8 -7/8" (225 mm) 41.8 lbs (19 kg) 2081 -9279 110 Ah 11- 3/16" (284 mm) 10 -1/2" (267 mm) 9" (230 mm) 82 Lbs (37 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the tables on page 3 mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. NOTE: When wired in series for 24 V output, these batteries are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. _ iGeneiit atteryCSpecif canons., Nominal Voltage Rating 12 Volts per battery Discharge Rating 20 Hour Rate Typical Charge /Discharge Cycles 100 to 150 Preferred Charge Temperature Range 60° F to 90° F (15.6 °C to 32.2° C) 2 S2081- 0006 -18 5/2007 • ,Battery, Compatibllltyfor'Flre`.Alarm Control P.anel;Mounting' NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Battery Simplex Control Panel Model Series (see legend and notes below) Model Capacity 4003 4004 4004R 4005 4006 8 4009 4010 4100U 4100 & 4120 4020 4008 (all models) (2, 4 or 6 -Unit) (2, 4 or 6 -Unit) 2081 -9272 6.2 Ah ✓ J ✓ ✓ ✓ ✓ J 1, 2, or 3 bay ✓ J 2081 -9274 10 Ah ✓ ✓ ✓ ✓ ✓ ✓ J 1, 2, or 3 bay ✓ J • 2081 -9288 12.7 Ah ✓ NA ✓ ✓ ✓ ✓ J 1, 2, or 3 bay J ✓ 2081 -9275 18 Ah J NA Note 3 ✓ Ext Ext Note 2 1, 2, or 3 bay ✓ ✓ 2081 -9287 25 Ah NA NA Note 3 Ext Ext NA ✓ 1, 2, or 3 bay J Ext 2081 -9271 33 Ah NA NA Note 3 Ext NA NA Note 3 1, 2, or 3 bay Ext Note 4 (rectangular) 2081 -9276 33 Ah NA NA Note 3 Ext NA NA Note 3 1, 2, or 3 bay J Ext ( "square ") 2081 - 9296 50 Ah NA NA Note 3 NA NA NA Note 3 2 or 3 bay Ext Ext 2081 -9279 110 Ah Requires external battery cabinet J = Can be placed in the respective equipment cabinet Ext = External battery cabinet is required, refer to selection chart on page 4 NA = Not applicable /not compatible NOTES: 1. These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 2. 4010 Cabinets will accommodate 2081 -9275, 18 Ah batteries, but will not allow bottom entry conduit. 3. Use 4081 series companion cabinet and charger, refer to page 4. 4. 4020 Cabinets will accommodate 2081 -9271, 33 Ah batteries, but will not allow bottom entry conduit. 5. Some control panel models are listed for battery replacement reference only. External {Battery Qab net Compatibility Reference: Battery Cabinets without Chargers (connects to charger in panel) 2081 -9287 . ;;;� :� "2081- 927.1 .2081- 9276;., :208t.9296:,`2081.9279 . Cabinet Panel Compatibility 18 Ali 29 Ah •Rectangular 33,Ah ; Square.33 Ah 50;Ah 110 Ah • 2081 -9270 multiple ✓ J ✓ ✓ ✓ NA 2081 -9280 41000/4100 +NAB <:' NA,;,'. . '':::` ".` NAr•, NA.:r,:NA= :. ✓ 2081-9281 multiple J J ✓ ✓ ✓ NA 2081 -9282 4009 -9801 multiple ; NA NA : _ ;_ ` ;NA NA ` 4009 - 9802 multiple ✓ NA ✓ ;`NA;: ?..: . • ; -. NA?.' . NA. Battery Cabinets with Chargers .2081 -9275 2081 -9287. .2081 -9271 2081 -9276. - ..2081 -9296 ,2081 -9279 Cabinet Panel Compatibility 18 Ah* -: 25 Ah Rectangular 33 Ah Square 33 Ah 50.Ah ; : • 110Ali • 4081 -9301 4081 -9302 4004R and 4010 ✓ ✓ ✓ ✓ J NA 4081 -9303 4081 -9304 4081 -9306 4100U NA NA: NA NA J J 4081 -9308 Batteries smaller than those listed are normally mounted in the product cabinet ** 25 Ah capacity was effective as of 7/2005. J= Can be placed in the respective equipment cabinet NA = Not applicable /not compatible 3 S2081- 0006 -18 5/2007 �ExfernalB tteryCabinet�Speclficaton , Battery Cabinets Without Chargers; Shallow Design with Front Door • Model Color Listings Description' Dimensions 2081 -9281 Beige UL and 2 -Unit, 4100 style cabinet without charger; with locking 25-3/4" W x 20- 314" H x 6-3/4'' D FM solid door and battery shelf, primarily for use with 50 Ah (654 mm x 527 mm x 171 mm) 2081 -9282 Red batteries 4009-9801* Beige UL and For up to 25 Ah External battery cabinet without charger, 16 -1/4" W x 13 -1/2" H x 5 -3/4" D FM batteries* with locking solid door and battery (413 mm x 343 mm x 146 mm)* For up to 33 Ah harness; for close - nippled mounting to 25 -3/4" W x 20 -3/4" H x 4 -1/8" D 4009 -9802 Beige UL batteries fire alarm control panel cabinet (654 mm x 527 mm x 105 mm) Depth increased for 25 Ah batteries effective 7/2005. Battery Cabinet Without Charger; Deep Design with Hinged Lid Model • Color Listings Description •- Dimensions 2081 -9270 Red Not listed Battery cabinet without charger; cabinet has vented front, 26 -1/2" W x 12" H x 12" D and hinged lid with support rod and lock on top (673 mm x 305 mm x 305 mm) Chargers for use with 4010 Fire Alarm Control Panels and 4004R Suppression Release Systems (refer to data sheet S4081 -0001) .Model Color 'Input Voltage Description Dimensions 4081 -9301 Beige Battery cabinet with charger for the 4010 and 120 VAC 4004R fire alarm control panel; for up to 50 Ah 4081 -9302 Red 22 -1/2" W x16 -3/4" H x 8 -3/8" D batteries; with front door 4081 -9303 Beige (572 mm x 425 mm x 213 mm) 220/240 VAC Listings include: UL, ULC, FM, CSFM, and MEA 4081 -9304 Red (NYC), see data sheet for details Battery Cabinet Without Charger for 110 Ah Batteries; for use with compatible panel mounted chargers (refer to data sheet S2081 -0012) Model & Compatible_ Listings Color Cabinet Description Chargers - Charger. Description - .: , . Dimensions • 4100 -9xxx 4100U System Power Supplies Series (SPS) 4100 -5111 Battery cabinet for 4100 -5112 41000 Additional SPS 2081 -9279, 110 Ah 4100 -5113 2081 -9280 batteries; includes 4100 -5125 4100U Listings Red 80 A battery fuse, 4100-5126 (RPS) ) RP5 Remote Power Supply 26 -1/2" W x 12" H x 12" D include: UL terminals and 4100 -5127 (673 mm x 305 mm x 305 mm) and CSFM battery connection 4100 -5120 cables; see data 4100 -5121 4100U TrueAlert Addressable sheet for details 4100 -5122 Power Supply (TPS) 4100 -0104 4100 -0114 4100 Legacy power supplies 4100 -0124 4100U Compatible Battery Cabinet With Charger for 110 Ah Batteries (for ULC listed systems and for other applications unable to use panel mounted power supply charger; refer to data sheet S4081 -0002) Model.: Color Input Voltage = : , . Description • :,,= a:, _:: F: : ; , ::, :-;::, ; , . : .Dimensions 4081 -9306 Red 120 VAC Battery cabinet with charger for up to 110 Ah batteries; 220/230/240 VAC, NOTE: Required for ULC listed charging of 27 -7/8" W x 13 -1/2" H x 14 -5/8" D 4081 -9308 Red 110 Ah batteries; Listings include: UL, ULC, FM, (708 mm x 343 mm x 371 mm) multi- tapped CSFM, and MEA (NYC), see data sheet for details 4100 -9837 Green LED Power -on Indicator Kit, required for ULC listing, mounts above access panel using knockout provided Tyco, Simplex, and the Simplex logo are trademarks of Tyco International Services AG or its affiliates in the U.S. and /or other countries. ro Simplex Tyco Safety Products Westminster • Westminster, MA • 01441 -0001 • USA S2081- 0006 -18 5/2007 www, tycosafetyproducts- usa -wm. con © 201)7 Tyco Safety Products IVestminster. All rights reserved. All spec and other information shown were current as of document revision date and are subject to change without notice. Multi - Application Peripherals ° i l and Accessories Non -Coded Manual Stations UL Listed, CSFM and 2099 Series Single and FM Approved Double Action Operation FEATURES kv..:,,;, e : lu t , ::,. �,,: ate?" V4 r; ram • Single action models `i .,,,„ °44 , A1 • Double action models available as: Ili iviiIK:6Ainv:::vcii ) "`ATia t _�. — Breakglass \ , - Push T e =;' rvk:'$ y r.,i" ,rte° • Institutional model , : .e ' N ;.i f��sSen "a�'d- :m%�= .,x <`':,s1 r" .; r,N1 - __ RI „ si'saS � �? °, ma �.�' — Key operated only �' � � „ � '� �,.- At • Pull lever protrudes when alarmed tli* * OEA ,tea • Tamper resistant reset key lock: � I ,� �;,,, Single Action Station � - — Keyed same as fire alarm cabinet ' • Pre - signal and annunciator contact options w v> ;' O t s tti • Local alarm cover option '' �„ �y, w. _ g `° �& "' o • Surface, flush, or semi -flush mounting , " • Complies with ADA requirements 11 P . Double Action - - p , l I 7'Jvr, i la Station (Breakglass) Mi'`ttl' t . OPERATION = ' ~:: ' i `"ii Single Action Stations require a firm downward pull to ,r ,. activate the alarm switch. Completing the action breaks.:;,w ? ; O an internal plastic break -rod (visible below the pull : " . : '_., .it. y Tm Y " lever). The pull lever latches into the alarm position and r te' remains extended out of the cover to provide a visible T, ° .' Double Action indication of which station was alarmed. L � e �` !•, , w S tation (Push Type) Double Action Stations (Breakglass) require the r * : t operator to strike the front mounted hammer to break , r;}, OPERA T D - the glass and expose the recessed pull lever. The pull . . r ONLY;f, . lever then operates as a single action station.; J =f;y *, = ark "w =` ''` '~' ^ ' "`" gEg Double Action Stations (Push Type) require that a , `A¢ , .. " ° t`, . t11 spring loaded interference plate (marked PUSH) beOnl pushed back to access the pull lever of the single Single Action Station L tl action station. With Institutional . , Cover ; .4, . l , Institutional Stations are designed to activate by key 1l - operation only. This allows access for manual alarms to , i . <ni; be initiated by authorized personnel. Operation requires '� :;Vi: "'. .. Z S,64' . key insertion and opening of the station cover. t *. &, , ` ,;F,,il Pre- Signal Option activates when the lever is pulled. General alarm initiation requires a key to activate a Local Fire Alarm keyswitch located behind the pull lever. Cover Option Station Reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. * These products have been approved by the California State Fire Marshal (CSFM) If the break -rod is used it must be replaced. pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7150 - 0026175 for allowable values and/or conditions concerning material presented in Testing requires physical activation of the pull lever this document. it is subject to re- examination, revision, and possible cancellation. Additional listings may be applicable, contact Simplex for the latest status. Refer to data (except for institutional stations). sheet S2099 -0009 for stations specifically intended for use in New York City . ULC listed stations are documented separately, contact Simplex for assistance. © 2000 Simplex Time Recorder Co. All rights reserved. S2099 0007 - 6/00 APPLICATIONS Refer to NFPA 72, the National Fire Alarm Code, distance not more than 200 ft (61 m) to the nearest (reference section 5 -9), and all applicable local codes station from any point in the building. When manual for complete requirements for manual stations. The station coverage appears limited in any way, additional following summarizes the basic requirements. stations should be installed. Stations shall be located in the normal path of exit and Construction. Covers and pull levers are constructed distributed in the protected area such that they are of chip resistant and dirt resistant, high impact Lexan unobstructed and readily accessible. polycarbonate. Covers are red with white lettering and pull levers are white with red lettering. Mounting shall be with the operable part not less than 3 1/2 ft (1.1 m) and not more than 4 1/2 ft (1.37 m) ENVIRONMENTAL SPECIFICATIONS above floor level. Temperature Range 32° to 140° F (0° to 60° C) At least one station shall be provided on each floor. Humidity Range up to 90% RH at 90° F (32° C) Additional stations shall be provided to obtain a travel NON - ADDRESSABLE MANUAL STATION FEATURE SELECTION CHART (see note 3 for addressable station reference) r f Annunciator T:, Annunciator a Local Alarm 4 Institutional + ? , +Mounting t' ,> k z w "' General AlarmG �` On =�? ;: Contacts,N OContactsN C t Cover ; n`-Covere y '. _ ;NotesE { � r. 2099 - 9754 ; :.n _ x' 3,s ; 1 • 2099 -9101 , . , • 2099 -9102 �_; ' ✓ __ 2 2099 - 9107 ✓ ✓:�` 2099 -9755, �� ✓ 1 2099-9762 , . V.:,.` ✓ 1 eft Double Action t? ` x � ? $� = Xidytif gnu Ann nc ator `r ° Annu`nClatO ` ' M rtlfl aCA a Models i' 1 f 7 P �' a + aph S I C 4 e x t a � � � BreakGlass,.0 � Push ,�� ti tw re Signal�� �''•` Contacts N O T� j Contacts N C � � + ��� r Notes fft,_ f(General T,.:. `a�`.t -zn'' , `''' '`"� 1:=1 +r nYt `F�", : 24•:ii�' n'-.i� #` ?s7 �YS,-r ,! `� '�4-r ' ° ,' s4 f :. "%` �k: i - ' '€4� +etf" i „"iL . ru 4k"a `- 209919103 - 4 V 1 t.; 2099 -9104 ✓ ;:_._; • = ' :, ✓ 2099 -9105 ✓ 2 2099 - 9108 ✓ ✓ ✓ � 2099-9756 ✓ .. - 1 2099 - 9757 ``. ✓ ✓ 2099 -9758 ✓ ✓ 2 .:�s >: ._. _ ... t ... . 2099 -9759 z':; u ` s ✓ ✓ ✓ , L' ACCESSORIES CC ]a Y4ys F.. % 4 ,, 2 {` g dM Rt t'4,t .,� ,Zk r dC�4 l ( . Y S t ' °" A - F r` ,� s � E l Y , 7r 1� ! L p� C 459 ':' i' i .1 w ai �' �. ��F. a.x �DescripttOn �?��n_ i.��``c�c",.�:�!t�(.�,e .:,ia -�,�_ nix::..; �° er .jt�= :h.;�:,..a...5."t�.4:�;.� t, e- w?� `_.�_�.r..fia`��i_,�t.L"��_..; «,._�,.,�.:.� Moldel. ��_�..,��, �� ..�,..__ . ..�._. 2099 -9803 Replacement breakglass (standard, English) 2099 =9804 Replacement break -rod 2099 -9819 Flush adapter kit, black (refer to page 4) 2099 -9820 Flush adapter kit, beige (refer to page 4) 2099 -9822 Replacement retaining clip for breakglass 2099 -9828 Institutional cover kit 2975 -9178 Red, surface mount box, sheet metal, 5 3/16" H x 4" W x 2 3/16" D (127 mm x 102 mm x 56 mm) 2975 -9022 Red, cast aluminum surface mount box, 5" H x 3 7/8" W x 2 3/16" D (127 mm x 98 mm x 56 mm) NOTES: 1. These models can be semi -flush mounted using a standard single gang 2 1 /2" (64 mm) deep switch box. DO NOT RECESS BOX, mount box flush or with 1/16" (2 mm) maximum protrusion. These models can also be surface mounted on a Wiremold box model number V5744S, 4 5/8" H x 2 7/8" W x 2 1/4" D (117 mm x 73 mm x 57 mm). 2. For surface mount, these models require 2975 -9178 or 2099 -9022 boxes. For semi -flush mount, these models require a 4" (102 mm) square box with a single gang cover plate (see diagram on page 3). 3. For information on Simplex addressable manual stations, refer to data sheet S2190 -0012 for MAPNET II addressable stations and data sheet S4099 - 0001 for IDNetTM addressable stations. S2099- 0007 -14 6/00 page 2 - MOUNTING INFORMATION Refer to installation instructions 574 - 656 (PER - 21 - 502) for additional information. SURFACE MOUNTING Knockouts located 4" (102 mm) . top and bottom c�� 2975 -9178 Box hl.IIIW FIRE ED A LARM 5 2/16" (132 mm) Station cover , 5" PULL DO hinges open for _i (127 mm) installation access - i■....... 1 .ii 1 A Ii■ 2 3/16" A\ (56 mm) 2975 -9178 Box El Simplex ■ 1 "(25.4 mm) 3 3/4" (95 mm) —0-1 Side View, Surface Mounting SEMI MOUNTING, 4" BOX (refer to selection chart for requirements) 4" (102 mm) square box, 2 1/8" (54 mm) minimum Mount flush or with depth RACO #231 or equal (supplied separately) 1/16" (2 mm) maximum extension DO NOT RECESS o \ r \ O� I / Electrical box \) o \) o • � \ Station side view ---4- FIRE °ALARM 11111' o PULL DOWN � - •. Sin gang cover plate, 3/4" (19 / \Single gang cover mm) extension, RACO #773 or Wall �� plate equal (supplied separately) Li Simplex surface - -____— Side View, Semi - Flush Mounting S2099- 0007 -14 6/00 page 3 FLUSH MOUNTING REFERENCE INFORMATION Flush mount adapter kit Front View 2099 -9819, Black Side View 2099 -9820, Beige �x '' 1 R Box must be recessed into wall A z � , � ` � q ; — ■.- 1" to 1 1/8" (25.4 mm to 29 mm) i;',4,4eStO,I ,,,,,,..„--410 vv \ ' ZP - A, ,, 24,11 0 (203 mm) . 4 • �� r H ole cutout must be a v- �� PUL1 Do N minimum of 6" H by 5" W 6' ''' slz,(� a t (152 mm by 127 mm) ' 0 e k fir, `4 w 0 Zk� - ▪ , ". a'WUE ,aa�:..:._ . r't'e ,:,� t -y ",t;��°r'• f ��. *., ' .z? - ", s,�� -�,��, � s 4 11/16" (119 mm) , " <•n ,v,.: ; i z, ; r 1,;,',P4 . : . ' 4V "`� �� square box, 2 1/8" (54 mm) minimum • ( ,'44 � P = "t _ s 3 , ` ms s,: Wall depth (by others) r 4 3/4" (121 mm) e surface 6 3/4" (171 mm) Simplex, the Simplex logo, MAPNET, and /DNet are either trademarks or registered trademarks of Simplex Time Recorder Co. in the U.S. and /or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NEPA). Lexan is a registered trademark of General Electric Co. S2099 0007 - 6 /00 ... . Westminster, Massachusetts 01441 -0001 U. S. A. X eSi Offices and Representatives Throughout the World Visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of printing and are subject to change without notice. • w SIMPleX TrueAlarm Smoke Detectors • UL, ULC Listed; FM, CSFM, TrueAlarm Photoelectric Smoke Detectors and MEA (NYC) Approved* for Two -Wire and Four -Wire Bases Features:( Photoelectric smoke detector with on- board�'�� • TrueAlarm sensitivity drift compensation UL listed to Standard 268 Functional chamber enclosure: 11 W 1 MI:1 • Louvered design enhances smoke capture bye ^`�.-.,- directing flow to chamber • Entrance areas are minimally visible when ceiling mounted > 4098 -9601 TrueAlarm Photoelectric Detector Mounted in Base Multi- function indicator LED indicates normal and alarm conditions Magnetically operated functional test: • Initiates alarm and verifies performance • Identifies general sensitivity status using detector S, oecifications LED V oltage 15 to 32 VDC from Fire Alarm Control Models available in two sensitivity settings: Panel IDC • 4098 -9601, Standard Sensitivity, nominal 2.8 % /ft Standby Current 100 n @ 24 VDC obscuration Up to 86 mA maximum, exact current is • 4098 -9605, Special Application Sensitivity, Olp Current, 2-Wire determined by alarm current limiting of o Opeerr ation connected IDC nominal 3.5%/ft obscuration Alarm Current, 4 -Wire 24 mA typical 24 VDC Available base options: Operation yp @ • Bases for 2 -wire or 4 -wire operation Auxiliary Relay Ratings Refer to page 2 under Product Selection • Auxiliary alarm relay output Air Velocity Range 0 -2000 ft /min (0 -610 m /min) Optional remote alarm indicating LED UL Listed Temp. Range 32° to 100° F (0° to 38° C) Operating Temp. Range 15° to 122° F ( -9° to + 50° C) Humidity Range 10% to 95% RH from 32° to 122° F Descry • tlO f 1F y (0° to 50° C) non - condensing Simplex TrueAlarm photoelectric detectors Color Frost White provide many of the proven TrueAlarm analog sensing 4 - 7/8" Dia. x 1 - 7/8" H, mounted in base features for applications where detectors are connected to Dimensions (124 mm x 48 mm); refer to page 3 for conventional 2 -wire or 4 -wire initiating device circuits detail (IDCs). Each TrueAlarm detector has an on -board microprocessor that evaluates its photoelectric light scattering chamber activity and makes an intelligent decision based on light obscuration history as to whether an alanu condition is present. TrueAlarm detectors are packaged in a patented • ULC listed models are designated with a "C" suffix such as 4098- 9601C. This product has p g p been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of housing that minimizes the visibility of the air intake the California Health and Safety Code. See CSFM Listing 7272 - 0026:219 for allowable louvers from the normal viewing locations while values andlor conditions concerning material presented in this document. It is subject to re- examination, revision, and possible cancellation. Accepted for use - City of New York maintaining a high performance smoke capture ability Department of Buildings - MEA35 -93E. Additional listings maybe applicable: contact your Bases are available for remote alarm LED indicator local Simplex product supplier for the latest status. connections and auxiliary relay outputs. t TrueAlarm smoke detector operation is protected by one or more of the following U.S. Patents' 5,155,468; 5,173,683; 5,400,014: 5,543,777; 5,710,541; D383,407; D388,352; D392,573. S4098- 0015 -5 10/02 TrueAlarrn'Smoke Detector }Features;'' Intelligent Data Evaluation. Conventional smoke directly into alarm with the magnetic test. If there is an detectors will typically drift toward being too sensitive off - normal condition, the LED pulses first to indicate the due to the accumulation of dust and dirt. With TrueAlarm condition and then goes into alarm. (See page 3.) analog detection, data from the photoelectric chamber is ASIA 60.000: ce: monitored and analyzed at the detector to provide a continuously shifting reference point. Detector Locations. Locations should be determined Drift Compensation. The data evaluation and its only after careful consideration of the physical layout and shifting reference point provide a software filtering contents of the area to be protected. Refer to NFPA 72, process that compensates for environmental factors (dust, the National Fire Alarm Code. On smooth ceilings, • dirt, etc.) and component aging, establishing an accurate smoke detector spacing of 30 ft (9.1 m) may be used as a reference for evaluating new activity. With this filtering, guide. For detailed installation information, refer to 4098 Detectors, Sensors, and Bases Application Manual the resulting drift compensation provides a significant (574 -709). reduction in the probability of false or nuisance alarms caused by shifts in sensitivity — either up or down. Sensitivity Selection. The 4098 -9601 standard Magnetic Test Information. Status information is sensitivity detector is recommended for most applications. available by performing the magnetic test and observing When a special application for a reduced sensitivity the detector LED pulses. The LED will normally go detector is required, the 4098 -9605 should be considered. Consult your local Simplex product supplier for assistance in determining the proper selection. P.eoduct Selection Smoke Detectors Model,' Description Sensitivity„ Compatibility ... ; , • , 4098 -9601 2.8 %/ft (standard) Compatible with bases: 4098 -9788, 4098 -9682, and TrueAlarm Photoelectric Detector 4098 -9605 3.5 %/ft 4098 -9683 Compatible Bases .Model = , .Description v ` Details* • • . . 4098 -9788 2-Wire Base with connections for IDC and LED connections are screw terminals for in /out wiring, Remote Alarm LED Indicator 18 to 14 AWG 4 -Wire Base with Auxiliary Alarm Relay Ratings, Single Form "C ", For Suppressed Loads: Relay Contacts and connections for Power limited, 3 A @ 28 VDC; Non -power limited, 3 A @ 120 VAC 4098-9682 Remote LED Alarm Indicator Wiring Connections (In /Out where required): NOTE: Requires external 24 VDC for Relay contacts and IDC wiring, color coded 18 AWG leads; operation LED wiring, screw terminals for 18 to 14 AWG 2 -Wire Base with Auxiliary Alarm Relay Ratings, Dual Form "C ", For Suppressed Loads: Relay & connections for Remote LED Power limited, 1 A @ 28 VDC; Non -power limited, 1/2 A @ 120 VAC - Indicator 4098 -9683 Wiring Connections (In /Out where required): NOTE: Must be connected as the only device on the IDC to ensure relay Relay contacts and IDC ( -), color coded 18 AWG leads; operation. IDC ( +) and LED wiring, screw terminals for 18 to 14 AWG Detector Accessories Model " Description.. • - Details.' :.,.. Required for mounting to surface mounted 4" (102 mm) square or 4" octagonal boxes, and to 4" square flush mounted boxes 4098 -9832 Adapter Plate May be used when retrofitting existing bases Compatible with detector bases 4098 -9788, -9682, & -9683 4098 -9830 Remote LED Indicator Mounted on single gang stainless steel plate 2098 -9739 Encapsulated Dimensions: 2 -112" x 1-1/2" x 1" Required for 4 -wire circuits using 24 VDC (64 mm x 38 mm x 25.4 mm) 4098 -9682 base, one per circuit; select End -of -Line Relay Mounted on single gang mounting type as required; wiring is 2098 -9735 Plate Mounted stainless steel plate color coded 18 AWG wire leads Refer to pages 3 and 4 for dimensions and additional mounting details; 18 AWG = 0.82 mm 14 AWG = 2.08 mm 2 S4098- 0015 -5 10/02 • Detector- StatuLED.Indicat olns; LED Indication Status Pulses approximately every 4 seconds Normal Steady On Alarm LED Response to Magnetic Test * LED Indication Followed By 'Status Action LED turns ON Alarm is initiated Normal sensitivity is within None compensation range LED pulses quickly, 6 times in 3 seconds, Alarm is initiated More sensitive, out of normal then turns ON compensation range Cleaning or other • service is required LED pulses slowly, Alarm is initiated Less sensitive, out of normal 4 times in 8 seconds, compensation range then turns ON Does not initiate Alarm Detector is malfunctioning Service is required Testing requires placing a magnet at the designated location on the detector cover for 4 seconds. Refer to Application Manual 574 -709 for further test and maintenance information. Dimensitir sa and_kReference lnfolrmatloii 1/4" (6.4 mm) 1 I1 6 -3/8" (162 mm) is Y I 4 4098 -9832 Adapter Plate 4 -7/8" (124 mm) ►I Base height 1 -7/8" 11/16" (48 mm) (17 mm) _IIII■ . 1 ,;, gt.t V : ®III® 'Il lialoN•ensoussigen1ngssfizzigna/mull LED Status Indicator (with clear lens) 4098 -9601 & -9605 Dimensions Mounted on Base i ALARM 0 f3 Simplex i 4098 - 9830 Remote LED Indicator (not to scale) 3 S4098- 0015 -5 10/02 ,Mountie a ialnfaiiiii on (Electrical boxes are supplied by others.) • Electrical Box Requirements: Without relay (base 4098 - 9788): 4" octagonal or 4" square, 1 -1/2" deep Single gang, 2" deep With relay (bases 4098 -9682 and 4098 - 9683): • 4" octagonal, 1 -1/2" deep, with 1 -1/2" extension ring 4" square, 1 -1/2" deep, with 1 -1/2" extension ring Surface mount reference allaffiliniMEZEI / • ,4..1,,,,x, ti .x„ ; , , ... „,,... .. 4 d 1 iii, 4” (102 mm) sr-- 4" (102 mm) square box 0 0 octagonal box 4 1 -1/2" (38 mm) Flush mount reference, mount even with final minimum box depth surface, or with up to 1/4" (6.4 mm) maximum recess 4098 -9832 Adapter Plate, required for mounting to surface mounted boxes and to 4" square flush mount boxes 4098 -9682 and 4098 -9683 include a relay module that ."111. mounts in base electrical box 11111 Smoke Detector Bases Nil/ 4098 -9788, 9682, & -9683 IliMi . •1•1111 10n1® au\ -1.Ia 4 - . 4098 -9601, -9605 Smoke Detector Tyco, Simplex, the Simplex logo, and TrueAlarm are trademarks of Tvco International Services AG or its affiliates in the U.S. and /or other countries NFPA 72 and National Fire Alarm Code are registered trademarks of National Fire Protection Association (NFPA). e p ex TEPG - US • 91 Technology Drive • Westminster, Massachusetts • 01441 - 0001 • USA S4098 0015 - 5 10/02 co 2002 TEPG -US (a Tyco company). All rights reserved. All specifications and other information WWW. tepg. corn shown were current as of document revision date and are subject to change without notice. • Simple' X TrueAlert Multi- Candela Notification Appliances • UL, ULC Listed; FM Visible Notification Appliances with Horn and Synchronized and CSFM Approved* Flash; Non - Addressable, SmartSyncTM Operation Compatible Features: z srr . Audible /visible (AN) notification appliances with efficient electronic horn and high output xenon strobe available for wall or ceiling mount - N Operation is compatible with ADA requirements (refer„ • d 4 to important installation information on page 3) • Rugged, high impact, flame retardant thermoplastic V '". housings are available in red or white with clear lens ` F R E Operates over a two -wire SmartSync circuit to provide: • Horns that are controlled separately from strobes on the same two -wire circuit • "On- until - silenced" and "on- until - reset" operation on [i:...._/i the same two -wire pair F 1 R E • Horn control that can be selected to be temporal coded, _ march time coded, or on continuously i • Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate • Class B (Style Y) operation requires connection to a compatible SmartSync NAC or to SmartSync Control Wall and Ceiling Mount A/Vs Module (SCM) 4905 -9938 D,escri �tion' • Class A (Style Z) operation when connected to the 4905 -9938 SCM or with 4100U series fire alarm control Multi- Candela TrueAlert ANs with horn and panel NACs synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are Wall mount ANs features: both impact and vandal resistant and provide a convenient • Wiring terminals are accessible from the front of the strobe intensity selection. Since each model can be housing providing easy access for installation, selected for strobe intensity output, on -site model inspection, and testing inventory is minimized and changes encountered during • Covers are available separately to convert housing color construction can be easily accommodated. Optional adapters and wire guards: Wall mount A/V housings are a one -piece assembly (including lens) that mounts to a single or double gang, or • Wall mount AN adapters are available to cover surface 4" square standard electrical box. The over can be mounted electrical boxes and to adapt to Simplex® quickly removed (a tool is required) and covers are 2975 -9145 boxes available separately for color conversion. • UL listed red wire guards are available for wall or ceiling mount ANs Ceiling mount ANs install using standard 4" electrical boxes. Color choice is determined by model number. Visible notification appliance (strobe): , , Sfrobet l�ntensityii • 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured During installation, a selection plug at the back of the behind strobe housing housing determines the desired strobe intensity. An • UL listed to Standard 1971 attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the • Regulated circuit design ensures consistent flash output side of the strobe lens. and provides controlled inrush current * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Audible notification appliance (horn): Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125- 0026:317 for allowable values and/or conditions concerning material presented in this • Low current, 24 VDC electronic horn with harnaonically document. It is subject to re- examination, revision, and possible cancellation. This product was not approved by MEA (NYC) as of document revision date. Refer to page 2 for listing rich output sound suitable for either coded or steady status of wire guards. Additional listings may be applicable; contact your local Simplex operation product supplier for the latest status. Listings and approvals under Simplex Time Recorder • UL TL listed to Standard 464 Co. are the property of Tyco Safety Products Westminster. ** Simplex two-wire strobe synchronization operation is protected by U.S. patent No. 5,559,492 and SmartSync horn /strobe operation is protected under U.S. Patent No. 6,281,789. S4906- 0002 -2 9/2004 Strobe App cation�Selectlon_Y SmartSynczTwo:';Wlre''Control Proper selection of visible notification is dependent on Smart Sync operation mode allows a two -wire circuit to occupancy, location, local codes, and proper applications provide the ability to activate both the horn and strobe on of: the National Fire Alarm Code (NFPA 72), ANSI the same NAC and then allow the horn to be silenced A117.1; the appropriate model building code: BOCA, while the strobe remains flashing. The horn operates as ICBO, or SBCCI; and the application guidelines of the "on- until- silenced" while the strobe operation is Americans with Disabilities Act (ADA). "on- until - reset." s SmartSync Control Sources �Synchr`omzed (Strobes Multiple Strobes. When multiple strobes and their 0 4100U and 4010 Fire Alarm Control Panels (refer to • reflections can be seen from one location, synchronized data sheet S4010 -0001 for details; refer to data sheet flashes reduce the probability of photo- sensitive reactions S4100 -0031 for basic 4100U information) as well as the annoyance and possible distraction of 0 4009 IDNet NAC Extender (refer to data sheet random flashing. The multi - candela strobes of these A/Vs S4009 -0002) are synchronized by the controlling SmartSync operation • SmartSync Control Module (SCM) 4905 -9938 (refer to NAC. data sheet S4905 -0003) Additional SmartSync compatible notification appliances include separate horns and combination born/strobe notification appliances. ,Product;S electlon,- Multi - Candela A/Vs Model • 'Mounting `Housing Coior • "FIRE" Lettering Description _ „ ._ , , . > 4906 -9127 Wall Red White 4906 -9129 White Red Horn with Multi - Candela Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela; operates with SmartSync two -wire 4906 -9128 Ceiling Red White control 4906 -9130 White Red Wall Mount AN Adapters Model Descrip Dimen 4905-9937 Red 5 3/8" H x 5-1/4" W x 1 -5/8" D Surface Mount Adapter Skirt; use to cover 1 -1/2" (38 mm) deep surface mounted boxes (136 mm x 133 mm x 41 mm) 4905 -9940 White depth with strobe = 4 -3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975 -9145 box (typically for 8- 5/16" x 5 -3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975 -9145 Red Mounting Box, requires Adapter Plate 4905 -9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) SmartSync Control Module Model„ ;, , °:Description,' Dim ns, , 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4 -1/8" x 1 -1/4" D (102 mm) square box; refer to data sheet S4905 -0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount ANs • Model;,;(" ,Description: ,Dimensions":, 4905 -9994 Red cover with white "FIRE" lettering 5 -1/8" H x 5" W x 1 -1/2" D 4905 -9995 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount A/V Adapter Model, ;:Descnpt�on:� �;� _,, ,: e., ,., ,.: :.. • J; . • _ ohs - .:., , , :.... amens 4905 -9961* Wall mount red wire guard with mounting plate, compatible with semi -flush 6- 1/16" H x 6- 1/16" W x 3 -1/8" D or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905 -9927* Red Wire Guard for mounting to flush mounted electrical box 8-1/2" x 6-1/8" x 3" (216 mm x 156 mm x 76 mm) 4905 -9928* Ceiling Red Adapter Plate, required to mount guard to surface 9" x 7" Mount mounted electrical box (229 mm x 178 mm) 4905 -9915 White Surface Mount Adapter Box Extension, use to cover 4 -3/4" x 6 -7 /8" x 1 -1/2" deep, 4905 -9916 Red 1 -1/2" deep surface mounted boxes (121 mm x 175 mm x 38 mm) * UL listed by Space Age Electronics Inc. 2 S4906- 0002 -2 9/2004 A/V Specifications`. Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 VDC; see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz: with up to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93 %, non - condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm to 3.31 mm ; two wires per terminal for in /out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Voltage 16 VDC 24 VDC 33 VDC Sound Type (see Note 2) Steady Coded Steady Coded Steady Coded Horn Output Ratings @ 10 ft (3 m) Reverberant Chamber, 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA UL 464 Test Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions (with lens) 5- 1/8 "'H x 5" W x 2 -3/4" D (130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per • '15 cd . 30 cd • ' ' ' 75 cd . .. 110 cd' Strobe Setting (see Note 3 below) 75 mA 116 mA 221 mA 285 mA Mount Reference.RMS Currents, "''._18 VDC- '' • • 70 mA 101 mA - 184 mA: "'- ' ;243 mA at other voltages , - 24 VDC ' " - 60 mA -. . - ... 84 mA ' - ' ' 143 mA - '''.=: r "1'85_mA Housing Dimensions (with lens) 4 -3/4 L" x 6 -7/8" W x 2 -5/8" D (121 mm x 175 mm x 67 mm) Maximum RMS Current Rating per A' ' 15 cd "r,:, ' " ' . 30 cd'x ._ ... ' 75;cd'4.- - .,., -,' ... c: :_110 cd ,;,.. Ceiling Strobe Setting (see Note 3 below) 86 mA 132 mA 250 mA 320 mA Mount Reference. RMS'Currents- , :,- 18 VDC,';` 2..81 MA 119 mA :" ';, _. "r :216.mA , , - ' 283 mA ' , ' g '' - >- a;r,, . 167.mA' '' , .. at other volts es ° ;x xs: ,'; ; 24 VDC' - 70 mA- :::� 97:mA: �= .;�,.�.:, , -. - - � . 217 - ;_ ' NOTES: 1. "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Under the same test conditions, coded horn output "peak" sound level readings are typically 4 dBA higher. 3. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation {ReferenceSurface or ° o r Mounting is compatible with ri ( 1 0 r l IG1 IMPORTANT! WALL MOUNT single gang, double gang, and _ 4" (102 mm) square boxes, INSTALLATION HEIGHT REFERENCE 1 -1/2" (38 mm) deep, by others 11 I ._ liri Bottom is of lens either even with or slightly Electrical _ o _ I igtlit ! O above bottom box outline Wirin access hole �" ^ g 0 C k� ham+ I i of compatible\ �;li \ 1' © boxes + Wiring terminals for ;i = � p, ,. r , 't¢ ' I 1 � t SmartSync operation " I I r srr3,<:;," � Mounting Holes: NFPA 72 requires " 1111 4" square (4) 80" (2.03 m) _„ ®sue - '' ''. � that the entire lens minimum ■ � Gnu e ` Sin g ang (2) be not less than ����� Double gang (3) 80" and not greater =� than 96" above the Transparent housing finished floor and lens assembly Intensity selection 1 plug, accessible only 1 111r from rear of housing, • F 11 n la factory setting is 15 cd VIM Removable cover Strobe intensity (tool required) viewing slot 3 S4906- 0002 -2 9/2004 ,Ce i>ng ifif'AN and <Guar iiiikillation Referdic ' Ceiling reference, 4" 102 mm square box, Optional 4905 -9928 Adapter Plate, ( ) q surface mounted box 1 -1/2" (38 mm) minimum depth required for surface mounted electrical box MO :,' Four mounting clamps included, two each side Ceiling reference, �� � ' • flush mounted box ''£, ii immany ■ A� �� Optional 4905 - 9915/ -9916 Adapter, . recommended for surface mounted box � � � — — x II Optional 4905 -9927 . ^ / Wiring terminals are Red Wire Guard ;` i located behind the housing I am' E End View ® .� li Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd WaIIyMoun$iLnstallation Referen "Adapter` ki a Guard and rAdaptee Sidi Surface Mounting Reference 2975 - 9145 Box with Optional Adapter Skirt o and Optional Wire Guard - 7 -. o Surface mount conduit and O box shown for reference ' , 4" (102 mm) square _iUl�I ,. , — , — • , ' box (p profile, 1-1/2" I�fly, 1�111�1111 II mm) _ �■ , , ( Optional 14111 O O I 4 905 -9961 II! NM ■ Wire Guard i I AN i um ) o r h,: _ • _ � � I' 4905 -9931 Adapter Plate —I � = Optional Surface Mount Adapter Skirt, O 4905 -9961 Optional Wire Guard 1 -1/2" deep: 4905 -9937, Red; . (shown here for reference only, 4905 -9940, White (conduit knockouts 4905 -9931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tvco. Simpler. the Simples logo, IDNet, TrueAlert, and SmartSvnc are trademarks of Tyco International AG or its affiliates in the U.S and /or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Si hex Tyco Safety Products Westminster, Westminster, MA • 01441 -0001 • USA S4906- 0002 -2 9/2004 www. tycosafetyproducts- usa -wm. corn © 2004 Tvco Safety Products Westnuinster. All rights reserved. All specifications and other information shown were current as ojdocumem revision date and are subject to change without notice. aSi plex System Accessories UL Listed* 4081 Series End -of -Line Resistor Harnesses ;Features For use as Class B end -of -line resistor: • Connect these resistor harnesses where end -of -line resistors are required at remote locations to monitor wiring continuity • Refer to specific circuit specifications for end -of -line resistor requirements UL Listed to Standard 864 Product S'election - 9 -1/2" (241 mm) Reference ** Model Number Description 4081 -9001 733 -892 2.2 kS2, 1/2 W ;w ' -3 > 4081 -9002 733 -893 3.3 kS2 1 W 4081 -9003 733 -896 4.7 kQ, 1/2 W ' 4081 -9004 733 -886 6.8 kf2, 1/2 W ,. 4081 -9005 733 -984 1.8 kS2, 1/2 W 4081 -9006 733 -890 560 f2, 1 W 4081 -9007 733 -891 1.2 kS2, 1 W > 4081 -9008 733 -894 10 kf2, 1/2 W 4081 -9009 733 -912 20 S2, 1 W 4081 -9010 733 -973 1 kS2, 1 W 4081 -9011 733 -974 100 f2, 1/2 W 4081 -9012 733 -985 22 kf2, 1/2 W Typical 4081 Series Resistor Harness Assembly 4081 -9013 734 -086 4.99 kS2, 1/2 W, ± 1% (full size except for lead length) 4081 -9014 734 -092 2.4 kS2, 1/2 W 4081 -9015 734 -093 1.5 kS2 1/2 W 4081 -9016 734 -149 150 kg2, 1/2 W `e'cifications' 4081 -9017 734 -171 3.9 kS2, 1 W 4081-9018 734 -168 10 kS2, 1 W Overall Length Approximately 9 -1/2" (241 mm) Wire Length 7" (178 mm) ± 1" (25 mm) ** ± 5% tolerance except as noted. z Wire Size 18 AWG (0.82 mm 2 ) Insulation 600 V, black Leads Stripped 0.5" (13 mm); tinned Resistor Resistor leads are crimped to wires Attachment and covered with heat shrink tubing This product was not approved by ULC, FM, MEA (NYC), or CSFM as of document revision date. Additional listings may be applicable, contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. S4081 -0003 7/2004 • • • • Tvco, Simplex, and the Simpler logo are trademarks of Tvco International Services AG or its affiliates in the U.S. and /or other countries ES Simplex Tyco Safety Products Westminster • Westminster, MA • 01441 -0001 • USA S4081 -0003 7/2004 www. tycosafetyproducts- usa -wm. coo 2004 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as of document revision data and are subject to change without notice.