Loading...
Plans ' — ,, eaoo k'- , r� ^7 /% 2) SW /q/ZaL✓S R..0 tqcD I Fire & Building Products REC .VED Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 JA CiT ®F U 201,E rr Series TY -FRB — 2.8, 4.2, 5.6, and 8.0 K- ' thvisyo^► Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage tained when exposed to corrosive at- G eneral mospheres. Although corrosion resis- , r , . N tant coated sprinklers have passed the f'°` Description standard corrosion tests of the appli - - :, =r. cable approval agencies, the testing is ..x i1 V The Tyco® Series TY -FRB, 2.8, 4.2, not representative of all possible cor -� s '' ,x, ion 5.6, and 8.0 K- factor, Upright and Pen- rosive atmospheres. Consequently, it i x :$� dent Sprinklers described in this data is recommended that the end user be ' , 4 N ,, sheet are quick response - standard consulted with respect to the suitability :t �_ *�•' coverage, decorative 3 mm glass bulb of these coatings for any given corro- (: . type spray sprinklers designed for use sive environment. The effects of ambi , ,� �" a: in light or ordinary hazard, commercial ent temperature, concentration of ,, , . ' 1 ) r occupancies such as banks, hotels, chemicals, and gas /chemical velocity, �.-1i0 shopping malls, etc. should be considered, as a minimum, , The recessed version of the Series along with the corrosive nature of the TY -FRB Pendent Sprinkler, where ap- chemical to which the sprinklers will be plicable, is intended for use in areas exposed. -- with a finished ceiling. It uses either a An intermediate level versions of the -#- two -piece Style 10 (1/2 inch NPT) or Series TY -FRB Pendent Sprinklers , x ., Style 40 (3/4 inch NPT) Recessed Es- are detailed in Technical Data Sheet f cutcheon with 1/2 inch (12,7 mm) of TFP356, and Sprinkler Guards are de- x '1 recessed adjustment or up to 3/4 inch tailed in Technical Data Sheet TFP780 (19,1 mm) of total adjustment from the ' flush pendent position, or a two -piece WARNINGS : " ;i" , ti;; - ` , " Style 20 1/2 inch NPT or Style 30 3/4 The Series TY -FRB Sprinklers de ,-' p ' ; inch NPT) Recessed Escutcheon with scribed herein must be installed and , 4 v f ' , 1/4 inch (6,4 mm) of recessed adjust- maintained in compliance with this ment or up to 1/2 inch (12,7 mm) of document, as well as with the applica- total adjustment from the flush pen- ble standards of the National Fire Pro - dent position. The adjustment pro- tection Association, in addition to the vided by the Recessed Escutcheon re- standards of any other authorities hay- Model /Sprinkler duces the accuracy to which the fixed ing jurisdiction. Failure to do so may pipe drops to the sprinklers must be impair the performance of these de- Identification cut. vices. Corrosion resistant coatings, where The owner is responsible for maintain- Numbers applicable, are utilized to extend the ing their fire protection system and de- life of copper alloy sprinklers beyond vices in proper operating condition. TY1131 - Upright 2.8K, 1/2 "NPT that which would otherwise be ob The installing contractor or sprinkler TY1231 - Pendent 2.8K, 1/2 "NPT manufacturer should be contacted TY2131 - Upright 4.2K, 1/2 "NPT with any questions. TY2231 - Pendent 4.2K, 1/2 "NPT IMPORTANT TY3131 - Upright 5.6K, 1/2 "NPT Always refer to Technical Data TY3231 - Pendent 5.6K, 1/2 "NPT Sheet TFP700 for the "INSTALLER TY4131 - Upright 8.0K, 3/4 "NPT WARNING" that provides cautions TY4231 - Pendent 8.0K, 3/4 "NPT with respect to handling and instal- TY4831- Upright 8.0K, 1/2 "NPT lation of sprinkler systems and corn- TY4931- Pendent 8.0K, 1/2 "NPT ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 AUGUST, 2007 TFP171 Page 2 of 10 TFP171 ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED SSU* SURFACE NPT MAKE -IN ESCUTCHEON 1 DEFLECTOR � 7 /16" � �' 5 ��1 I (57,2 m) =� ��` I NOMINAL I ' 2 111 MAKE -IN ( 9/16 " 39,7 mm ) I 411P WRENCH `�� 2- 3/16" (55,6 mm) 3 l ■ FLATS 1 / %1!1 \\ II 7 SSP DEFLECTOR * - 2 -7/8" (73,0 mm) DIA. 1/2" NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED SSU* SURFACE 1/2" T MAKE -IN ESCUTCHEON i DEFLECTOR G // \ Iii1TTT �Rr \��\ 6* t �__ 7/16" P 5 2- 3/16" ,■ Mr � N 11,1 mm) I 4 (55,6 mm) � �`�` ■ I I 1�1 MAKE -IN 1 1 -1/2" Olei 2- 3/16" r z its 2 (38,1 mm) I I WRENCH 1 (55,6 mm) e II FLATS _ 3 SSP DEFLECTOR * 2 -7/8" (73,0 mm) DIA. 1/2" NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K- FACTOR, 1/2 INCH NPT TFP171 Page 3 of 10 ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED SSU* SURFACE NPT MAKE-IN ESCUTCHEON DEFLECTOR 6 1 �_ 7/16" `� 5 2- 3/16" �i } 1 15f,� (11,1 mm) i (55,6 mm) p 1 �� I NOMINAL 4 1 7 MAKE -IN 1 1/2" ‚ II, r �r 1 2 3/16" �� 2 (38,1 mm) WRENCH -- = 1 (55,6 mm) 0 -- FLATS _ I �l 3 i .cam_ ^— — �� PII�r - — / SSP DEFLECTOR* 2 -7/8" (73,0 mm) DIA. 1/2" NPT 1 1 PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw • FIGURE 3 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K- FACTOR, 1 /2.INCH NPT ESCUTCHEON 1/2" (12,7 mm) STYLE 30 or 40 PLATE SEATING NOMINAL RECESSED SSU* SURFACE NP MAKE -IN ESCUTCHEON DEFLECTOR 6 I 1=1 5 2- 5/16" (12,7 mm) (58,7 mm) — �y��— NOMINAL MAKE -IN I lir 4 1-9/16" __ ri 2 -1/4" 0 ;r 2 (39,7 mm) qI I _ WRENCH (57,2 mm) O q 3 11 FLATS OA r i •=—=.----------•- rL SSP DEFLECTOR * f— 2 -7/8" (73,0 mm) DIA. 3/4" NPT } PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K- FACTOR, 3/4 INCH NPT . 1 U P 360 - c0007 tqco Fire & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Style 65 One -Piece Flush Escutcheon Style 401 Two -Piece Deep Escutcheon 1/2 Inch and 3/4 Inch NPT General WARNINGS The Style 65 and 401 Escutcheons de- Descri t� ®n scribed herein must Escutcheons installed and p maintained in compliance with this , , The Tyco Style 65 and 401 Escutch- document, as well as with the applica ��� ;_ eon Plates illustrated in Figures 1 and 2 ble standards of the National Fire Pro- t ection Association, in addition to the are designed for use with pendent and horizontal sidewall automatic sprin- standards of any other authorities hay klers in fire protection systems where ing jurisdiction. Failure to do so may "'` "" the piping is installed above a ceiling impair the performance of these �� or behind a wall. They are used to im- devices. STYLE 65 prove the overall appearance of the in- The owner is responsible for maintain- ONE -PIECE ESCUTCHEON stallation by concealing the clearance ing their fire protection system and de- holes required for the connecting pip- vices in proper operating condition. ing and fittings to the sprinkler. The installing contractor or sprinkler - The Escutcheon Plates are available manufacturer should be contacted in two styles: Style 65 flush one -piece with any questions. " "' v (non - adjustable), and Style 401 deep two -piece (adjustable). ° �� � Technical ,: '` , ` The flush one -piece (non - adjustable) '` ;; , ; ' --2 Style 65 Escutcheon Plates (Fig. 1) are Data • . °' used where the position of the sprin- ; " ' kler "escutcheon plate seating sur- Approvals ``' ' ' ` face" (relative to the ceiling line or wall) With reference to NFPA 13, listings /ap , :' :,:; , A sk. ". can be fixed by adjusting the length of provals are not required for metallic x " 4 the interconnecting piping. escutcheons used for non - recessed :...h=..., The two -piece Style 401 Escutcheon applications. . rir:= ve` Plates (Fig. 2) are used where it is nec- Finishes STYLE 401 essary to position the sprinkler away Chrome, White, or Brass TWO -PIECE ESCUTCHEON from the ceiling /wall surface so that Material spray will not be adversely affected by Carbon Steel protruding obstructions such as light fixtures and HVAC diffusers. The adjustment provided by the Style 401 Escutcheon Plates reduces the ac- curacy to which the length of the fixed pipe drops or horizontal pipe runs to the sprinklers must be cut, and it pro- vides additional flexibility in the inter- connecting pipe. The separable, two -piece design of the Style 401 allows installation of the sprinklers and pressure testing of the fire protection system /evaluation of leak tightness prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. They also permit the removal of suspended ceiling panels, for access to building service equipment, without having to first shut down the fire protection sys- tem and remove sprinklers. Page 1 of 4 DECEMBER, 2007 TFP777 • Page Z of 4 TFP777 3 -1/2" DIA. 2- 13/16" DIA. [...._ (89,0 mm) (71,4 mm) 2" DIA. 2 -1/2" DIA. L ___ - (50,8 mm) (63,5 mm) 2 -1/4" DIA. 11 (57,2 mm) CEILING CEILING eta" S W AIII SURFACE SURFACE AM Uri% i ) El i ) i '_� SKIRT * To 2 3 MAX. `i ( ) • MIN.1 -7/8" 1/2" FIT FRICTION _. (47,6 mm) _ 1/2" OR _AI (12,7 mm) 3/4" NPT CUP * �I� t OPENING ESCUTCHEON PLATE SEATING 1/2" OR SHOWN WITH SURFACE 3/4" NPT _. _A_,_ SERIES TY -FRB OPENING ESCUTCHEON 5.6 K- FACTOR SHOWN WITH PLATE SEATING PENDENT SPRINKLER SERIES TY-FRB SURFACE FOR REFERENCE 5.6 K- FACTOR PENDENT SPRINKLER * ORDERED FOR REFERENCE SEPARATELY FIGURE 1 FIGURE 2 STYLE 65 ONE -PIECE STYLE 401 TWO -PIECE DEEP FLUSH ESCUTCHEON ADJUSTABLE ESCUTCHEON