Correspondence FILE COPY
//iuiU;lll �Ip��III�Q��)
February 25, 2005
CITY OF TIGARD
Malcolm & Sharon Eslinger OREGON
11575 SW Pacific Highway, PMB 160
Tigard, OR 97223
RE: SITEWORK FOR NEW COMMERCIAL BUILDING
Project Information
Site Permit: SIT2004 -00023 Construction Type: V N
Tenant Name: Atlanta Building Occupancy Type: Unknown
Address: 6830 SW Atlanta Street Occupant Load: NA
Area: 4,072 Sq Ft ( Footprint) Stories: 2
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC)
1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999
edition. The submitted plans are approved subject to the following.
EROSION
• Erosion control measures shall be in place prior to excavation or grading.
RETAINING WALLS
• Special Inspection is required for the Installation of the Geogrid and related
compaction. The special inspection agency of record shall furnish inspection reports
to the Engineer of Record, Alexander H. Hurley, the General Contractor and the
City of Tigard, Building Division, attention Hap Watkins. All discrepancies shall be
brought to the immediate attention of the general contractor for correction. The
special inspector shall submit a final signed report stating whether the work requiring
special inspection was, to the best of the inspector's knowledge, in conformance with
the approved plans and specifications and the applicable workmanship provisions of
the code. 1701.3 OSSC
ACCESSIBILITY
• Accessible walkways and routes shall not exceed a running slope of 1 unit vertical in
20 units horizontal (5% slope). Cross slopes shall not exceed 1 unit vertical in 50
units horizontal (2% slope).
• Accessible parking spaces and access aisles shall be located on a surface with a slope
not to exceed 1 unit vertical in 50 units horizontal in all directions. 1104.4.3 OSSC
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall
be maintained on the jobsite. The plans shall be available to the Building Division inspectors
•
throughout all phases of construction. 106.4.2 OSSC
American with Disabilities Act (ADA): It shall be the responsibility of the Architect,
Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA
requirements for the structure. The City of Tigard reviews the plans and inspects the structure
only for compliance with Chapter 11 of the OSSC which may not include all of the
requirements of the ADA.
Premises Identification: Approved numbers or addresses shall be provided for all new
buildings in such a position as to be plainly visible and legible from the street or road
•
fronting the property.
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of
Tigard in tracking and processing the documents.
Respectfully
ri al • ,
Senior s Examiner
FILE COPY
September 22, 2004
Alex Hurley CITY OF TIGAR®
AKS Engineering
13910 SW Galbreath Drive,# 100 OREGON
Sherwood, OR 97140
RE: SITEWORK FOR NEW COMMERCIAL BUILDING
Site Permit: SIT2004 -00023 Construction Type: V N
Tenant Name: Atlanta Building Occupancy Type: Unknown
Address: 6830 SW Atlanta Street Occupant Load: NA
Area: 4,072 Sq Ft ( Footprint) Stories: 2
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC)
1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999
edition. The following information is required prior to the issuance of a Site Permit:
ACCESSIBILITY
1. The accessible parking shown on sheet 8 of 14 indicates the access aisle on the
driver's side of the parking space. Section 1104.1 OSSC requires the access aisle to
be located on the passenger side of the parking space. Please revise any affected plan
sheets to reflect the changes .
2. Accessible walkways and routes shall not exceed a running slope of 1 unit vertical in
20 units horizontal (5% slope). Cross slopes shall not exceed 1 unit vertical in 50
units horizontal (2% slope). 1103.2.4.3 OSSC
3. An accessible parking sign is not indicated on the plans. A parking sign is required
and shall be 84 inches to the bottom of the sign. Provide a detail.
FIRE REVIEW
• Complete the enclosed "TVF &R FIRE FLOW and HYDRANT WORKSHEET ". The
allowable area permitted and the number of hydrants required will be based on the
worksheet.
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of
Tigard in tracking and processing the documents.
Respe, 1•
ria ' : lalo
Senior Pl.ns Examiner
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
ENGINEERING PLANNING SURVEYING FORESTRY
13910 S.W. Galbreath Dr., Suite 100 TELEPHONE (503) 925 -8799
Sherwood, OR 97140 FAX (503) 925 -8969
ENGINEERING & FORESTRY
E-MAIL: aks @aks eng.cor� C E 0 VE D
SEP252006
September 22, 2006 CITY OF TIGARD
BUILDING DIVISION
Hap Watkins
City of Tigard
13125 SW Hall Blvd
Tigard, OR 97223 • F co
RE: Atlanta Commercial Building (City of Tigard Case Fi No. SDR 2003 - 00009)
30 su)
Mr. Watkins:
The purpose of this letter is to certify that the storm water quality and quantity system for the Atlanta
Commercial Building appears to have been installed in accordance to the plans prepared by AKS
Engineering & Forestry, LLC. dated February l6 2005.
Please call if you have any questions. 9_ Z 2 -0‘
Sincerely, ��'� PRO,c
AKS Engineering & Forestry, LLC.
7 57 /t
• C OREGON ry
Alexander H. Hurley P.E., P.L.S., Principal < 9 c gRY � 15' 4 4,
. N DER H. N
'RENEWAL DATE: �� 3 U- 1
•