Correspondence City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 • September 28, 2006 T I G' Atlanta Commercial Building 6830 SW Atlanta Street Tigard OR 97223 Malcolm & Sharon Eslinger LLC 11575 SW Pacific Hwy Tigard OR 97223 Re: BUP2004 -00496 new 8,067 sq.ft. office building To whom it may concern: This letter is to certify that all requirements of building permit BUP2004- 00496, issued for a building shell, have been completed. The final inspection was performed and approved on September 28, 2006, by inspectors from the City of Tigard. No tenant spaces are included in this permit, nor shall any tenant improvement be occupied until such time as each space is approved by final inspection of its specific permits, approved for the use intended and provided with a Certificate of Occupancy. The City neither guarantees nor warrants to the owner, occupant or any other person that this letter evidences strict and complete compliance with each and every ordinance or regulation of the City or the State of Oregon affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and /or occupant of the premises. This letter certifies only that the work covered under the permit number listed above has been completed. It is not permission to occupy tenant spaces. Sin : ely, / 41 a. or I • Darrel Watkins Inspection Supervisor i:Bldg /complltr Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 March 1, 2005 = =° CITY OF TIGARD Eslinger Builders, Inc OREGON Malcolm Eslinger 1 1575 SW Pacific Hwy #160 Tigard, OR 97223 RE: HAINES CROSSING 2 OFFICE BUILDING - SHELL ONLY Project Information Building Permit: BUP2004 -00496 Occupancy Type: B Tenant Name: Haines Crossing 2 Construction Type: VN Address: 6830 SW Atlanta St Occupant Load: 64 Area: 8067 Sq Ft Stones: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition by Burrows Consulting Services, Inc. The submitted plans are approved subject to the following conditions. 1. Special Inspection: Special inspection is required for items listed on Burrows Consulting review document dated 11/26/04 item # 18. The special inspection agency of record shall furnish inspection reports to the Architect of Record, the General Contractor, and the City of Tigard, Building Division, attention Hap Watkins. All discrepancies shall be brought to the immediate attention of the general contractor for correction. The special inspector shall submit a final signed report stating whether the work requiring special inspection was, to the best of the inspector's knowledge, in conformance with the approved plans and specifications and the applicable workmanship provisions of the code. 1701.3 OSSC 2. American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC which may not include all of the requirements of the ADA. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy 109.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, 1"/;600fr al Henzel, Senior Plans Examiner r . ,.4 OFFI E COPY Burrows Consulting services, Inc. December 15, 2004 fgOO (J -OGLO' Brian Blalock Senior Plans Examiner City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Dear Brian, • The drawings and related design documents for the Haines Crossing #2 Office building (shell only) were reviewed and found to be in substantial compliance with the 1998 Oregon Structural Specialty Code. CONDITIONS OF CLEARANCE: 1. Final clearances and permit processing by the City. 2. Secure review and approvals from Planning, Engineering and Fire Department. 3. All applicable Fire Code requirements are to be reviewed and approved by the fire marshal. 4. Deferred submittals include plumbing, mechanical and electrical systems and the design of the roof trusses that will require separate plan reviews and permits. 5. City of Tigard's special inspection form completed and signed by the permit applicant? Special inspections include concrete, placement of reinforcing steel and adhesive anchors. DOCUMENTS TRANSMITTED: • 1. 2 sets of drawings by J.E. Krause Architect. 2. 2 sets of structural calcs by Joseph E. Krause. SENT TO YOU VIA: UPS, Next Day Ground Sincerely, Apv414 Mark Burrows 2777 Toni St. NE • Albany, Oregon 97321 • Ph (541) 926 -2131 • FAX (541) 926 -3236 , _ t Burrows Consultin g Services, Inc. November 26, 2004 Joseph Krause JE Krause Architect 15259 SE 82 Drive Clackamas, OR 97015 Dear Joseph, This is a plan review covering the construction of the Haines Crossing #2 Office building (shell only) located at 6830 SW Atlanta Street in Tigard, Oregon. This review is for compliance with the provisions of the Oregon State Structural , Specialty Code ('97 UBC) 1998 Edition. INTRODUCTORY INFORMATION: BUILDING YARDS: North: 60 feet + South: 57 feet East: 60 feet + West: 57 feet BUILDING AREA: 8067 sq. ft. OCCUPANT LOAD: Upper 32 Lower 32 Total 64 OCCUPANCY CLASS: B CONSTRUCTION TYPE: VN FIRE PROTECTION SYSTEM: none proposed STORIES: 2 HEIGHT: 31 feet r. 2777 Toni St. NE • Albany, Oregon 97321 • Ph (541) 926-2131' • FAX (541) 926 -3236 Please submit the following items for completion of the plan review process at your earliest convenience: 1. Indicate all set -backs from property lines to the exterior walls of the building. 2. Plumbing, mechanical and electrical plans to be submitted for separate reviews and permits as deferred submittals. 3. Approved address numbers shall be painted or affixed to the front of the building in a contrasting and highly visible color. The numbers shall not be less than six (6) inches in height and shall be affixed prior to final inspection. (502) and Uniform Fire Code 4. Provide a guardrail detail. The open space between the intermediate or ornamental pattern of guardrails shall be such that a 4 -inch diameter sphere cannot pass through. (509.2 & 509.3) 5. Guardrails and their connections shall be designed for a lateral load of 50 pounds per foot applied horizontally at right angles to the top rail. (Table No. 16 -B) Provide calcs for review. 6. Draft stops shall be installed in attics, mansards, overhangs, false fronts set out from walls and similar concealed spaces of buildings where an automatic sprinkler systems is not installed throughout, so that the area between draft stops does not exceed 3,000 sq. ft. and the greatest horizontal dimension shall not exceed 60 feet. (708.3.1.2.2) • Draft stopping materials shall not be less than 1/2 -inch gypsum board, 3/8 -inch plywood, 3/8 -inch Type 2 -M particleboard or other approved materials adequately supported. Openings in the partitions shall be protected by self - closing doors with automatic latches constructed as required for the partitions. Ventilation of concealed roof spaces shall be maintained in accordance with 1505. (708.3.1.3) 7. Fireblocking shall be installed in the following locations: • 1. In concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels and at 10 -foot intervals both vertical and horizontal. 2. At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings. 3. In concealed spaces between stair stringers at the top and bottom of the run and between studs along and in line with the run of stairs if the walls under the stairs are unfinished. (708.2.1) 8. Portable fire extinguishers shall be provided and installed as required by applicable standards and as directed by the authority having jurisdiction. (Uniform Fire Code) 9. The hand grip portion of handrails shall be not less than 1 1/4 inches nor more than 2 inches in cross - sectional dimension or the shape shall provide an equivalent gripping surface. Ends shall extend not less than 12 inches beyond the top and bottom risers and ends shall be returned or terminate in newel posts or safety terminals. (1003.3.3.6) 10. The highest operable part of environmental and other controls, dispensers, electrical and communication system receptacles on walls and other operable equipment shall be within at least one of the reach ranges specified in Section 1109.2, and not less than 36 inches above the floor. Electrical and communications system receptacles on walls shall be mounted no less than 15 inches above the floor. (1109.3.2) 11. Provide accessible signage for the restroom doors. 12. Stair nosings shall be flush and rounded to a radius of 1/2 inch maximum. Risers shall be sloped, or the underside, of the nosing shall have an angle of not less than 60 degrees from the horizontal. Nosings shall project no more than 1 -1/2 inches. (1109.8.3) 13. Hot water and drain pipes exposed under lavatories or sinks shall be insulated or otherwise covered. There shall be no sharp or abrasive surfaces under lavatories. (1109.10.7.4) 14. Provide details of the roof access ladder for review. 15. Submit the Oregon Energy Compliance Forms for review (exterior envelope) (1311.2) 16. The design of the roof trusses (tile roof) was not submitted with the plans and is not included in this plan review. Roof trusses are re- quired to be designed by an Oregon registered engineer or architect. When the truss supplier is selected, submit the structural drawings and design calculations for review to the City. 17. Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space. The net free ventilating area shall be not less than 1/150 of the area of the space ventilated. Exception: The area may be 1/300 of the area of the space ventilated provided 50% of the required ventilating area is provided by ventilators located in the upper portion of the space to be ventilated at least 3 feet above eave or cornice vents with the balance of the required ventilation provided by eave or cornice vents. (1505.3) All venting can be at the perforated aluminum soffits if the area is adequate. Please verify. 18. Special Inspections: In addition to the standard building inspections associated with this project, special inspections are required as outlined in Chapter 17 and as specified by the architect/engineer of record. Special inspections shall be provided for, but not limited to, the following: Reinforced Concrete with Design Strengths > 2500 psi Placement of Reinforcing Steel Adhesive Anchors The architect or engineer of record shall identify and assign other disciplines for special inspection as deemed appropriate. An approved Special Inspection Agency shall be employed by the owner or the engineer of record acting as the owner's agent. 19. Anchor ties for masonry and stone veneer not exceeding 5 inches in • thickness shall be spaced so as to support not more than 2 square feet of wall area but not more than 24 inches on center horizontally. Anchor ties shall be corrosion resistant, and if made of sheet metal, shall have a minimum size of No. 22 gauge by 3/4 inch or, if of wire, shall be a minimum of No. 9 gauge. Anchor ties in Seismic Zone No. 3 shall have a lip or hook on the extended leg that will engage or enclose a horizontal joint reinforcement wire.of No. 9 gauge or equivalent. The joint reinforcement shall be continuous with butt splices between ties permitted. (1403.6.4.2) The note on detail 6/8 does not include all the requirements of this code section. 20. Submit structural calcs for the site and building retaining walls. See details 3/8 and 7/8. . 21. The standard foundation detail 6/8 does not indicate any typical reinforcing steel? 22. Indicate all exterior wall header sizes on the plans. 23. Provide gravity load calcs for all concrete pier pads. 24. Provide structural calcs for all brick veneer lintels. Please make these corrections on the appropriate sheets of the plans and resubmit two copies of each sheet to Burrows Consulting. If you have any questions or concerns, please do not hesitate to call. Sincerely, Mark Burrows c: Brian Blalock Senior Plans Examiner Haines Crossing #2 shell.doc • F-11Q CROAR): - - Burrows Consultin g services, Inc. November 26, 2004 Joseph Krause - JE Krause Architect 15259 SE 82 Drive Clackamas, OR 97015 - Dear This is a plan review covering the construction of the Haines Crossing #2 Office building (shell only) located at 6830 SW Atlanta Street in Tigard, Oregon. This review is for compliance with the provisions of the Oregon State Structural Specialty Code ('97 UBC) 1998 Edition. INTRODUCTORY INFORMATION: BUILDING YARDS: North: 60 feet + South: 57 feet • East: 60 feet + West: 57 feet BUILDING AREA: 8067 sq. ft. . OCCUPANT LOAD: Upper 32 Lower 32 Total 64 OCCUPANCY CLASS: B CONSTRUCTION TYPE: VN FIRE PROTECTION SYSTEM: none proposed V STORIES: 2 HEIGHT: 31 feet -- 277TToni St — NE • Albany, .Oregon 97321 • Ph (541) 926 -2131 • FAX (541) 926 -3236 Please submit the following items for completion of the plan review process at your earliest convenience: 1. Indicate all set -backs from property lines to the exterior walls of the building. *S i P(vl 2. Plumbing, mechanical and electrical plans to be submitted for separate reviews and permits as deferred submittals. • 3. Approved address numbers shall be painted or affixed to the front of the building in a contrasting and highly visible color. The numbers shall not be less than six (6) inches in height and shall be affixed ' prior to final inspection. (502) and Uniform Fire Code Z oE13, • :4. Provide a guardrail detail. The open space between the , intermediate or ornamental pattern of 'guardrails shall be such that a 4 -inc diameter sphere cannot pas hro.0 ®®h. (509.2 & 509.3) 8 a � I3 • if Cie•v S l tt wig 5dI ta9at.11 • 5. . Guardrails and their connections shall be designed for a lateral load of 50 pounds per foot applied horizontally at right anglgs to t4e top rail. (Table No. 16 -B) Provide calcs for review. of 6.. - Draft stops shall be installed in attics, mansards, overhangs, false fronts set out from walls and similar concealed spaces of buildings - where an automatic sprinkler systems is not installed throughout, so that the area between draft stops does not exceed 3,000 sq. ft. and • the greatest horizontal di nsion shall not exceed 60 feet. (708.3.1.2.2) � ee"' 6- et Draft stopping materials shall not be less than 1/2 -inch gypsum board, 3/8-inch plywood, 3/8 -inch Type 2 -M particleboard or other approved materials adequately supported. Openings in the partitions . shall be protected by self - closing doors with automatic latches constructed as required for the partitions. Ventilation of concealed • roof spaces shall be maintained in accordance with 1505. (708.3.1.3) ' 7 13 7; Fireblocking shall be installed in the following locations: 1. In concealed spaces of stud walls and partitions, including • furred spaces, at the ceiling and floor levels and at 10 -foot intervals both vertical and horizontal. •' 2. At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and • cove ceilings. " 3. In concealed spaces between stair stringers at the top and bottom of the run and between studs along and in line with the run of stairs if the walls under the stairs are unfinished. (708.2.1) L— 3 -S tnee " I L 0+ L 8. Portable fire extinguishers shall be provided and installed as required by applicable standards and as directeed by the authority having jurisdiction. (Uniform Fire Code) Skeet 5 t3 9. The hand grip portion of handrails shall be not less than 1 1/4 inches nor more than 2 inches in cross - sectional dimension or the shape shall provide an equivalent gripping surface. Ends shall extend not • less than 12 inches beyond the top and bottom risers and ends shall be returned or terminate / newel posts or safety terminals. (1003.3.3.6.) sheet S Q . The highest operable part of environmental and other controls, dispensers, electrical and communication system receptacles on walls and other operable equipment shall be within at least one of the reach ranges specified in Section 1109.2, and not less than 36 inches above the floor. Electrical and communications system receptacles on walls shall be m ounted no less than 15 inches above the floor. (1109.3.2) � heet IC v-2. 04' 1 11: Provide accessible signage for the restroom doors. ee ' 10e4 h 12; - Stair nosings shall be flush and rounded to a radius of 1/2 inch maximum. Risers shall be sloped, or the underside of the nosing shall have an angle of not less than 60 degrees from the horizontal. Nosings shall project no more than 1 -1/2 inches. (1109.8:3) SY\ee*' cf t -3 13. Hot water and drain pipes exposed under lavatories or sinks shall be insulated or otherwise covered. There shall be no sharp or abrasive surfaces under lavatories. (1109.10.7.4) S1\ ± !Doc t3 14. Provide details of the roof access ladder for review. Sh e.eA ? o 15. ' Submit the Oregon Energy Compliance Forms for review (exterior envelope) (1311.2) - t c it 16. The design of the roof trusses (tile roof) was not submitted with the plans and is not included in this plan review. Roof trusses are re- quired to be designed by an Oregon registered engineer or architect. When the truss supplier is selected, submit the structur I drawin9s and design calculations for review to the City. 0Mraetor L.)• it 6004' +0 c! - etC r P 5 sc tom° _ • 17. Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space. The net free ventilating area shall be not less than 1/150 of the area of the space ventilated. Exception: The area may be 1/300 of the area of the space ventilated provided 50% of the required ventilating area is provided by ventilators located in the upper portion of the space to be ventilated at least 3 feet above eave or cornice vents with the balance of the required ventilation provided by eave or cornice vents.. (1505.3) All venting can be at the perforated aluminum soffits if the area is adequate. Please verify. S et 64:4' (,3 18. Special Inspections: In addition to the standard building inspections associated with this project, special inspections are required as outlined in Chapter 17 and as specified by the architect/engineer of record. Special inspections shall be provided • for, but not limited to, the following: * Reinforced Concrete with Design Strengths > 2500 psi * Placement Reinforcing Steel * Adhesive Anchors • The architect or engineer of record shall identify and assign other disciplines for special inspection as deemed appropriate. An approved Special Inspection Agency shall be employed by the owner or the engineer of record acting as the owner's agent. lech 19. Anchor ties for masonry and stone veneer not exceeding 5 inches in thickness shall be spaced so as to support not more than 2 square feet of wall area but not more than 24 inches on center horizontally. Anchor ties shall be corrosion resistant, and if made of sheet metal, shall have a minimum size of No. 22 gauge by 3/4 inch or, if of wire, shall be a minimum of No. 9 gauge. Anchor ties in Seismic Zone No. 3 shall have a lip or hook on the extended leg that will engage or enclose a horizontal joint reinforcement wire of No. 9 gauge or equivalent. The joint reinforcement shall be continuous with butt splices between ties permitted. (1403.6.4.2) The note on detail 6/8 does not include all the requirements of this code section. 5hee.+ 13 et (3 20. Submit structural calcs for the site pnd building retaining walls. See details 3/8 and 7/8. 21. The standard foundation detail 6/8 does not indicate any typical* reinforcing steel? '� c 22. Indicate all exterior wall header sizes on the plans. .Slite -÷ 4.4- F `3 23. Provide gravity load calcs for all concrete pier pads. Attot,c A 24. Provide structural calcs for all brick veneer lintels. c .± . $ ®- tz Please make these corrections on the appropriate sheets of the plans and resubmit two copies of each sheet to Burrows Consulting. If you have any questions or concerns, please do not hesitate to call. , Sincerely, Mark Burrows c: Brian Blalock Senior Plans Examiner • • Haines Crossing #2 shell.doc