Permit ,, CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT ': '- COMMUNITY DEVELOPMENT Permit #: FPS2011 -00082 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 08/23/2011 Parcel: 1 S136DA00101 Jurisdiction: Tigard Site address: 11410 SW 68TH PKWY Project: PERS Subdivision: PERS SITE Lot: Project Description: Clean agent fire suppression system. Contractor: MCCOY ELECTRIC CO INC Owner: OREGON, STATE OF PUBLIC 2014 SE 9TH AVE EMPLOYEES' RETIREMENT FUND PORTLAND, OR 97214 11410 SW 68TH PKWY TIGARD, OR 97223 PHONE: 503 - 234 -7521 PHONE: FAX: 503 - 234 -9473 FEES f Description Date Amount C Specifics: Permit Fee - COM 08/23/2011 $594.22 12% State Surcharge - Building 08/23/2011 $71.31 Type of Use: COM Plan Review - Fire Life Safety - COM 08/09/2011 $237.69 Class of Work: ALT Type of Const: IIB Info Process /Archiving - Lg Sheet (over 08/09/2011 $16.00 Occupancy Grp: B Height: ft 11x17) Stories: 3 Commercial Sprinkler System:. Sprinkler Required: Yes Sprinkler Type: Dry Standpipe Required: Hazard: Density: 0 Design Area: 0 K Factor: 0 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $919.22 Valuations: Required Items and Reports (Conditions) Sprinkler Valuation: $60,000.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notifi ation Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0090. You may obtain a copy of the rules or direct q stions to OU C by c. ' i 03. 32.1987 or 1.800.332.2344. / Issued By /01/ / Permittee Signature: L Call 503.639.4175 by 7:00 a.m. for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application -i , iPr 'clAJ Sy 54c111 FOR OFFICE USE ONLY R eceived City of Tigard �� Permo.: F... Date/By: it N r ��) 0.00-8-X. 111 11 13125 SW Hall Blvd., Tigard, OR 9 � Plan Review +' " 21 r Phone: 503.718.2439 Fax: 503. ,;t i , ® Date /By: ( I l ( Other Permit: ( • n ' (14_ 4. 3. 7 TIGARD Inspection Line: 503.639.4175 Date ReadyBy: _ JU • ® See Page 2 for / Internet: www.tigard- or.gov N 4 % 2 Notified/Method: 7 17 i/ p Supplemental I nformation 4 4 TYP O W O � • `S N \ _ REQUI DATA 1 D AN 2 FAMILY DWE ❑ New constr taGth ` � ,O Permit fees* are based on the value of the work performed. 1L� Indicate the value (rounded to the nearest dollar) of all ❑ Addition/alteration/replacement Other: Generator equipment, materials, labor, overhead, and the profit for the f work indicated on this application. CATEGORY OF CONSTRUCTION 1. ❑ 1- and 2- family dwelling ® Commercial /industrial Valuation: $ ❑ Accessory building ❑ Multi- family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION ;AND LOCATION • Total number of floors: Job site address: 11410 SW 68th Parkway New dwelling area: square feet City /State /ZIP: Tigard, Oregon 97223 Garage /carport area: square feet Suite/bldg. /apt. no.: Project name: PERS Standby Power & Fire Covered porch area: square feet Cross street/directions to job site: Interstate 5 Deck area: square feet • Other structure area: square feet REQUIRED. DATA .COMMERCIAL •USE CHECKLIST Subdivision: Lot no.: Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all Tax map /parcel no.: equipment, materials, labor, overhead, and the profit for the " „ rm' DESCRIPTION OF WORK ,- t ` s ,' N ` work indicated on this application. Installation of a 350kw generator and a clean agent fire suppression system to Valuation: „�•i CI _ support the PERS data center. Existing building area square feet New building area: square feet a ® PROPERTY OWNER 4 t _ ® ;TENANT Number of stories: Name: Department of Adminisrative Services Type of construction: Address: 1240 Ferry Street SE Occupancy groups: City /State /ZIP: Salem, Oregon 97301 Existing: Phone: (503)373 -2331 Fax: (503)378 -2093 New a y .® APPLICANTt . y -m �- 0 ❑ CONTACT PERSONT ' fi ' BUILDING P RMIT F EES* y Business name: DAS Facilities Division • .,,M� - . (P1edse.refertofee:schedule) .e, t, Structural plan review fee (or deposit): Contact name: Terry Nunley, Construction Project Manager FLS plan review fee (if applicable): . Address: 1240 Ferry Street SE Total fees due upon application: . City /State /ZIP: Salem, Oregon 97301 Amount received: Phone: •(503) 373 -2331 Fax:: (503) 378 -2093 ePHOVOLTAIeSOLAR:PANEL.SYSETM FEES * E -mail: Terry. Nunley @state.or.us ,.. R.. TO <. k, .:: ,.. « , ., . . , Commercial and residential prescriptive installation of a A i G. CONTRACTOR Q Y gr roof -top mounted Photo Voltaic Solar Panel System. Business name: T ,c deta i-n.i.., d Ha Co y t tiCr2 rG d //X Submit two (2) sets of roof plan with connection details � and fire department access, along with .the 2010 Oregon Address: a Ot 0 /e/ � e Mit . Solar Installation Specialty Code checklist. City /State /ZIP: Permit fee (includes plan review rL7a � 47�! and administrative fees)_ $180.00 Phone: (5 55 ) .2, 3 4' 752 rFax: (, ) kW- p(73 State surcharge (12% of permit fee): $21.60 CCB lie.: gl7 Total fee due upon application: $201.60 Authorized signature: • This permit application expires if a permit is not obtained C. within 180 days after it has been accepted as complete. Print name: Terry Nunley Date: 6/28/2011 * Fee methodology set by Tri- County Building Industry Service Board. I: \Building \Permits \BUP -COM PermitApp.doc 02/24/2011 440- 4613T(11/02/CO1N/1 /WEB) City of Tigard: Fire Protection Permit Checklist Page 2 - Supplemental Information Describe work to be done: 1.) ❑ New 2.) Modification to sprinkler heads only: ❑ Addition ❑ 1 -10 heads: No plan review required. ❑ Alteration ❑ 11+ heads: Plan review required. ❑ Repair Number of sprinkler heads: Additional description of work: Type of System (Complete A, B, C or D as applicable): • A.) Commercial Sprinkler ❑ Wet ❑ Dry Additional Standpipes Information: Hazard Group Density Design Area K. Factor Sprinkler Project Valuation: $ B.) Type I - Hood Fire System Hood Project Valuation: $ C.) Fire Alarm Submittal shall Battery Calculations ❑ Yes include: Individual Component ❑ Yes Cut Sheets Fire Alarm Project Valuation: $ D.) Residential Sprinkler (Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal (see A, B & C above): $ Permit fee based on project valuation (see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge (12% of permit fee): $ FLS Plan Review (40% of permit fee): $ TOTAL: $ Plan review requires a completed application and three (3) sets of plans at submittal. Plan review fees are required at submittal. I:\ Building \Permits \FPS- PermitAPP.doc 02/01/2011 2 Z 9Il- c7c7c)8 PASS /FAIL Enclosure Integrity Report CleanAgent 2001 retention time prediction program revision 2.5.4. Complies with NFPA 2001 Appendix C, year 2000 edition. By Retrotec, Inc, 2200 Queen Street, Bellingham, WA USA 98229 360- 738 -9835 www.retrotec.com Software Licensed to: Harvey and Price Company air leaks in Building, Location PERS Building, Tigard, OR Company, Contact PERS, Herbert Layton - Weihrauch E Room name Data Center (Rm. #121) Test number 1 Calibration Certificate # 5588 Certificate created 2010/08/03 agent leaks out Test date/time 2012/04/03 11:40 Net Protected Volume, V 5,691 ftA3 Tester Dan Liebersbach Maximum Protected Height, Ho 8.70 ft. Certified to Level: 2 - Single fan NFPA room test Minimum Protected Height, H 7.00 ft. Signature Static during retention, PSH 0.2 Pa Elevation above sea level 0 ft. Operating temperature 70 F Correction method NFPA 2001 (2000) Formula A -3 -5.3.3 Initial concentration, C 4.61% Correction factor 1 Mixing during retention No Agent Novec 1230 Agent quantity 222 lb. Total room leakage, ELA 0.79 ftA2 Minimum concentration, CF 4.61% Lower Leakage, BCLA 0.24 ft ^2 Minimum retention time 10.0 minutes Lower leakage entered without testing. This enclosure was tested in compliance with NFPA 2001 and 12A. Assuming no continual mixing during the retention period, 10- enclosure leakage could allow sufficient agent to be lost to cause an air /agent interface to descend from a Maximum 9 - Protected Height of 8.70 ft. to the Minimum Protected Height 8 - specified of 7.00 ft. - The retention time would then be 10.8 minutes which 7 exceeds the minimum retention time of 10 minutes. The 8 6- enclosure therefore passes this acceptance procedure. = 5- Notes c 4- m a 3_ 2- 1- 0 , , i • u i 0 1 2 3 4 5 6 7 8 9 10 Time (minutes) • • Maximum Protected Height — Agent Height - -- Minimum Protected Height Witnesses Printed on: 2012/04/03 11:56 Page 1 DOOR FAN TEST -- Total Room Leakage Data CleanAgent 2001 retention time prediction program revision 2.5.4. Complies with NFPA 2001 Appendix C, year 2000 edition. By Retrotec, Inc, 2200 Queen Street, Bellingham, WA USA 98229 360 - 738 -9835 www.retrotec.com Software Licensed to: Harvey and Price Company air leaks In Building, Location PERS Building, Tigard, OR Company, Contact PERS, Herbert Layton - Weihrauch • Room name Data Center (Rm. #121) Test number 1 • Calibration Certificate # 5588 Certificate created 2010/08/03 agent leaks out Total Room Leakage Operator In the room Smoke moves out of the room Temperature during test (F) Static pressure 0.2 Pa 70 inside 70 outside Depressurization Range for room pressures: -13.9 to -16.9 Blower range Room pressure -16.1 Auto corrected RP -15.5 Range 5 Flow Pressure 34.6 Auto corrected FP 34.2 Corrected flow (ft^3 /min.) -4701 Pressurization Range for room pressures: 14.3 to 17.3 Blower range Room pressure 10.4* Auto corrected RP 10.4 Range 5 Flow Pressure 32.6 Auto corrected FP 32.3 Corrected flow (ft^3 /min.) 3841 * Room pressure is too low. Retention time may be 6% shorter than predicted. ELA ft^2 @Pa FA Sloir n Intercept k, I Correlation !Standard Error ' ELAft^2 ] F Depressurization 0.68 15.5 0.5000 117.14 i NA NA Pressurization 0.89 10.4 0.5000 119.21 I NA I NA • Average 0.79 13.0 0.30 1 0.5000 y__ 118.17 ( 0.76 __ 10.0 0.30 Lower Leakage Lower leakage of 0.24 ft^2 @10.0 Pa was computed from an estimated lower leak fraction of 0.30 Technician: Dan Liebersbach Certified to Level: 2 - Single fan NFPA room test Yes Level 1 - Fire enclosure design basics for improving agent retention and passive protection Yes Level 2 - adds single door fan operation and NFPA clean agent retention time calculations No Level 3 - adds double door fan operation for Lower Leak measurement No Level 4 - adds multi -point ISO door fan operation and discharge pressure relief vent Printed on: 2012/04/03 11:56 Page 2 DOOR FAN TEST -- Graph CleanAgent 2001 retention time prediction program revision 2.5.4. Complies with NFPA 2001 Appendix C, year 2000 edition. By Retrotec, Inc, 2200 Queen Street, Bellingham, WA USA 98229 360 - 738 -9835 www.retrotec.com Software Licensed to: Harvey and Price Company air leaks in Building, Location PERS Building, Tigard, OR Company, Contact PERS, Herbert Layton - Weihrauch Room name Data Center (Rm. #121) Test number 1 Calibration Certificate # 5588 Certificate created 2010/08/03 agent leaks out 1000 • LL. 100 w . a1 2 �o 10 0.1 1.0 10.0 100.0 Room Pressure (Pa) - Total leakage, depressurizing — Total leakage, average Ai- Total leakage, pressurizing Printed on: 2012/04/03 11:56 Page 3