Loading...
Correspondence August 28, 2006 Steve Entenman Alpha Community Development 9600 SW Oak, Ste. 230 Portland Oregon 97223 RE: New Single Family Dwelling Project Information Building Permit: MST2006- 000178 Construction Type: VN Address: 13868 SW Andrew Terrace Occupancy Type: R -3 Area: 3168 sq. ft. Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; the State of Oregon Residential Specialty Code ORSC) 2005 edition and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The submitted plans have been reviewed and the following information is required prior to completion of the review. 1. The roof and ceiling construction shall be capable of accommodating all loads imposed and of transmitting the resulting loads to the supporting structural elements R801.2- On page G11 of the Full lateral and gravity analysis provided, b46 is named, on G12 it is listed as a girder. On the left elevation it is apparent there is no girder truss here; this would have to be a beam. Please design a beam to carry the resulting loads and make any necessary revisions to other structural elements involved. These revisions can be faxed to (503)624 -3681 When submitting revisions or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Loraine Williams, Plans Examiner (503) 718 -2708 Loraine @tigard - or.gov Cc: Steve Yureko 1